Shahram Vaezy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shahram Vaezy has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Vesna Zderic
Department of Electrical and Computer Engineering, The George Washington University, Washington, DC 20052, USA
4 shared publicationsJessica L. Foley
Department of Bioengineering, Box 355061, University of Washington, Seattle, Washington 98195, USA
3 shared publicationsCarol Cornejo
From the Departments of Bioengineering (S.V., V.Z., R.W.M.) and Surgery (R.K-J., G.J.J., C.C.), University of Washington, Seattle, WA, USA
2 shared publicationsEmil Chi
Department of Pathology, University of Washington, Seattle, WA, USA
2 shared publicationsJames W. Little
Department of Rehabilitation Medicine, University of Washington, Seattle, Washington, USA
2 shared publicationsLawrence Crum
2 shared publications
Latest Publications
- 8 September 2008
- Published by Wiley in Medical Physics
- Vol. 35 (10) , 4292-4299
Prevention of post‐focal thermal damage by formation of bubbles at the focus during high intensity focused ultrasound therapy
Safety concerns exist for potential thermal damage at tissue‐air or tissue‐bone interfaces located in the post‐focal region during high intensity focused ultrasound (HIFU) treatments. We tested the feasibility of reducing thermal energy deposited at the post‐focal tissue‐air interfaces by producing bubbles (due to acoustic cavitation and/or boiling) at the HIFU focus. HIFU (in‐situ intensities of , frequencies of ) was applied for to produce lesions (in turkey breast in‐vitro , and rabbit liver and thigh muscle in‐vivo ). Tissue temperature was measured at the tissue‐air interface using a thermal (infrared) camera. Ultrasound imaging was used to detect bubbles at the HIFU focus, appearing as a hyperechoic region. In‐vitro results showed that when no bubbles were present at the focus (at lower intensities of ), the temperature at the interface increased continuously, up to above the baseline by the end of treatment. When bubbles formed immediately after the start of HIFU treatment (at the high intensity of ), the temperature increased briefly for above the baseline temperature and then decreased to above the baseline by the end of treatment. Similar results were obtained in in‐vivo experiments with the temperature increases (above the baseline temperature) at the muscle‐air and liver‐air interfaces at the end of the high intensity treatment lower by and , respectively, as compared to the low intensity treatment. Thermal effects of HIFU at post‐focal tissue‐air interfaces, such as in bowels, could result in clinically significant increases in temperature. Bubble formation at the HIFU focus may provide a method for shielding the post‐focal region from potential thermal damage.
- 8 September 2008
- Published by Wiley in Medical Physics
- Vol. 35 (10) , 4292-4299
Prevention of post‐focal thermal damage by formation of bubbles at the focus during high intensity focused ultrasound therapy
Safety concerns exist for potential thermal damage at tissue‐air or tissue‐bone interfaces located in the post‐focal region during high intensity focused ultrasound (HIFU) treatments. We tested the feasibility of reducing thermal energy deposited at the post‐focal tissue‐air interfaces by producing bubbles (due to acoustic cavitation and/or boiling) at the HIFU focus. HIFU (in‐situ intensities of , frequencies of ) was applied for to produce lesions (in turkey breast in‐vitro , and rabbit liver and thigh muscle in‐vivo ). Tissue temperature was measured at the tissue‐air interface using a thermal (infrared) camera. Ultrasound imaging was used to detect bubbles at the HIFU focus, appearing as a hyperechoic region. In‐vitro results showed that when no bubbles were present at the focus (at lower intensities of ), the temperature at the interface increased continuously, up to above the baseline by the end of treatment. When bubbles formed immediately after the start of HIFU treatment (at the high intensity of ), the temperature increased briefly for above the baseline temperature and then decreased to above the baseline by the end of treatment. Similar results were obtained in in‐vivo experiments with the temperature increases (above the baseline temperature) at the muscle‐air and liver‐air interfaces at the end of the high intensity treatment lower by and , respectively, as compared to the low intensity treatment. Thermal effects of HIFU at post‐focal tissue‐air interfaces, such as in bowels, could result in clinically significant increases in temperature. Bubble formation at the HIFU focus may provide a method for shielding the post‐focal region from potential thermal damage.
- 26 November 2007
- Published by Wiley in Muscle & Nerve
- Vol. 37 (2) , 241-250
Effects of high‐intensity focused ultrasound on nerve conduction
The effects of various exposures (intensity, duration) of high‐intensity focused ultrasound (HIFU) on sciatic nerve conduction were investigated in vivo in rats. The objective was to identify HIFU exposures that produce biological effects ranging from partial to complete conduction block, indicating potential use of HIFU as an alternative to current clinical methods of inducing nerve conduction block. In the study, 26 nerves were exposed and treated with 5‐s applications of 5.7‐MHZ HIFU with acoustic intensities of 390, 2,255, 3,310, and 7,890 W/cm2 (spatial peak, temporal peak). Compound muscle action potentials (CMAPs), in response to electrical stimulation of the nerve proximal to the HIFU site, were recorded from the plantar foot muscles immediately before and after HIFU treatment and 2 and 4 h after treatment. Furthermore, a preliminary long‐term investigation was performed on 27 nerves with the same four sets of HIFU parameters. CMAPs were measured at the survival endpoint for each animal (7 or 28 days after treatment). For nerves treated with the three lower exposures, CMAPs decreased initially within 4 h or 7 days after HIFU treatment and then recovered to their baseline level at 28 days after treatment. For the highest exposure, however, CMAPs remained absent even 28 days after treatment. These exposure‐dependent effects of HIFU on nerve function suggest its future potential as a novel treatment for severe spasticity and pain. Muscle Nerve, 2007
- 26 November 2007
- Published by Wiley in Muscle & Nerve
- Vol. 37 (2) , 241-250
Effects of high‐intensity focused ultrasound on nerve conduction
The effects of various exposures (intensity, duration) of high‐intensity focused ultrasound (HIFU) on sciatic nerve conduction were investigated in vivo in rats. The objective was to identify HIFU exposures that produce biological effects ranging from partial to complete conduction block, indicating potential use of HIFU as an alternative to current clinical methods of inducing nerve conduction block. In the study, 26 nerves were exposed and treated with 5‐s applications of 5.7‐MHZ HIFU with acoustic intensities of 390, 2,255, 3,310, and 7,890 W/cm2 (spatial peak, temporal peak). Compound muscle action potentials (CMAPs), in response to electrical stimulation of the nerve proximal to the HIFU site, were recorded from the plantar foot muscles immediately before and after HIFU treatment and 2 and 4 h after treatment. Furthermore, a preliminary long‐term investigation was performed on 27 nerves with the same four sets of HIFU parameters. CMAPs were measured at the survival endpoint for each animal (7 or 28 days after treatment). For nerves treated with the three lower exposures, CMAPs decreased initially within 4 h or 7 days after HIFU treatment and then recovered to their baseline level at 28 days after treatment. For the highest exposure, however, CMAPs remained absent even 28 days after treatment. These exposure‐dependent effects of HIFU on nerve function suggest its future potential as a novel treatment for severe spasticity and pain. Muscle Nerve, 2007
- 1 August 2007
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 33 (8) , 1269-1276
Pulsatile Flow Phantom for Ultrasound Image-Guided HIFU Treatment of Vascular Injuries
- 1 August 2007
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 33 (8) , 1269-1276
Pulsatile Flow Phantom for Ultrasound Image-Guided HIFU Treatment of Vascular Injuries
- 1 August 2007
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 33 (8) , 1251-1258
Resection of Abdominal Solid Organs Using High-Intensity Focused Ultrasound
- 1 August 2007
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 33 (8) , 1251-1258
Resection of Abdominal Solid Organs Using High-Intensity Focused Ultrasound
- 1 June 2007
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 62 (6) , 1390-1395
Hemostasis and Sealing of Air Leaks in the Lung Using High-Intensity Focused Ultrasound
Background: Operative management of parenchymal lung injury can be complicated by persistent hemorrhage and air leak, which might require resection. Techniques that preserve parenchyma are associated with improved survival. High-intensity focused ultrasound (HIFU) has been demonstrated as a useful method for hemostasis in experimental solid organ injuries. We wished to investigate whether this could be applied to lung injuries. Methods: An intraoperative HIFU device (frequency of 5.7 MHz, acoustic power of 65 W), equipped with a titanium coupler, was used. Incisions (average length of 2.5 cm, and depth of 5 mm) were made in the lungs of 11 pigs, which created both parenchymal hemorrhage and air leakage. In treatment experiments, 70 incisions were sealed with HIFU. The HIFU application started within 10 seconds of inducing the injury. Hemostasis was assessed by visual observation of sealed incisions. The possible air leakage was determined by submersing the sealed incision under the layer of water and observing for air bubble formation. In control experiments, five incisions were left untreated to monitor air leaks and bleeding for 2 minutes. Results: Hemostasis and pneumostasis (sealing of air leaks) of the treated incisions were achieved in 51 ± 37 seconds (mean ± SD) (range of 10–210 seconds) of HIFU application time. Over 95% of incisions were hemostatic within 2 minutes of HIFU application. The treatment time was not dependent on the incision length or depth. In control experiments, the air leaking and bleeding were still present at 2 minutes after the injury. Conclusion: Intraoperative HIFU might provide an effective method of hemostasis and control of air leaks from lacerations caused by trauma.
- 1 June 2007
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 62 (6) , 1390-1395
Hemostasis and Sealing of Air Leaks in the Lung Using High-Intensity Focused Ultrasound
Background: Operative management of parenchymal lung injury can be complicated by persistent hemorrhage and air leak, which might require resection. Techniques that preserve parenchyma are associated with improved survival. High-intensity focused ultrasound (HIFU) has been demonstrated as a useful method for hemostasis in experimental solid organ injuries. We wished to investigate whether this could be applied to lung injuries. Methods: An intraoperative HIFU device (frequency of 5.7 MHz, acoustic power of 65 W), equipped with a titanium coupler, was used. Incisions (average length of 2.5 cm, and depth of 5 mm) were made in the lungs of 11 pigs, which created both parenchymal hemorrhage and air leakage. In treatment experiments, 70 incisions were sealed with HIFU. The HIFU application started within 10 seconds of inducing the injury. Hemostasis was assessed by visual observation of sealed incisions. The possible air leakage was determined by submersing the sealed incision under the layer of water and observing for air bubble formation. In control experiments, five incisions were left untreated to monitor air leaks and bleeding for 2 minutes. Results: Hemostasis and pneumostasis (sealing of air leaks) of the treated incisions were achieved in 51 ± 37 seconds (mean ± SD) (range of 10–210 seconds) of HIFU application time. Over 95% of incisions were hemostatic within 2 minutes of HIFU application. The treatment time was not dependent on the incision length or depth. In control experiments, the air leaking and bleeding were still present at 2 minutes after the injury. Conclusion: Intraoperative HIFU might provide an effective method of hemostasis and control of air leaks from lacerations caused by trauma.
- 1 January 2007
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 23 (2) , 203-211
Hemorrhage control using high intensity focused ultrasound
Hemorrhage control is a high priority task in advanced trauma care, because hemorrhagic shock can result in less than a minute in cases of severe injuries. Hemorrhage was found to be solely responsible for 40–50% of traumatic civilian and battlefield deaths in recent years. The majority of these deaths were due to abdominal and pelvic injuries with hidden and inaccessible bleeding of solid organs such as liver, spleen, and kidneys, as well as major blood vessels. High intensity focused ultrasound (HIFU) offers a promising method for hemorrhage control. An important advantage of HIFU is that it can deliver energy to deep regions of tissue where hemorrhage is occurring, allowing cauterization at depth of parenchymal tissues, or in difficult-to-access anatomical regions, while causing no or minimal biological effects in the intervening and surrounding tissues. Moreover, HIFU can cause both thermal and mechanical effects that are shown to work synergistically for rapid hemorrhage control. The major challenges of this method are in development of bleeding detection techniques for accurate localization of the injury sites, delivery of large HIFU doses for profuse bleeding cases, and ensuring safety when critical structures are in the vicinity of the injury. Future developments of acoustic hemostasis technology are anticipated to be for applications in peripheral vascular injuries where an acoustic window is usually available, and for applications in the operating room on exposed organs.
- 1 January 2007
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 23 (2) , 203-211
Hemorrhage control using high intensity focused ultrasound
Hemorrhage control is a high priority task in advanced trauma care, because hemorrhagic shock can result in less than a minute in cases of severe injuries. Hemorrhage was found to be solely responsible for 40–50% of traumatic civilian and battlefield deaths in recent years. The majority of these deaths were due to abdominal and pelvic injuries with hidden and inaccessible bleeding of solid organs such as liver, spleen, and kidneys, as well as major blood vessels. High intensity focused ultrasound (HIFU) offers a promising method for hemorrhage control. An important advantage of HIFU is that it can deliver energy to deep regions of tissue where hemorrhage is occurring, allowing cauterization at depth of parenchymal tissues, or in difficult-to-access anatomical regions, while causing no or minimal biological effects in the intervening and surrounding tissues. Moreover, HIFU can cause both thermal and mechanical effects that are shown to work synergistically for rapid hemorrhage control. The major challenges of this method are in development of bleeding detection techniques for accurate localization of the injury sites, delivery of large HIFU doses for profuse bleeding cases, and ensuring safety when critical structures are in the vicinity of the injury. Future developments of acoustic hemostasis technology are anticipated to be for applications in peripheral vascular injuries where an acoustic window is usually available, and for applications in the operating room on exposed organs.
- 27 October 2006
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 35 (1) , 109-119
Image-Guided High-Intensity Focused Ultrasound for Conduction Block of Peripheral Nerves
The objective of our work has been to investigate the use of ultrasound image-guided high-intensity focused ultrasound (HIFU) to non-invasively produce conduction block in rabbit sciatic nerves in vivo, a technique that could become a treatment of spasticity and pain. The work reported here involved the investigation of the duration of such conduction blocks after HIFU treatment and whether they resulted in axon degeneration. The right sciatic nerves of 12 rabbits were treated, under guidance of ultrasound imaging, with repeated 5-s applications of 3.2 MHz HIFU with in situ intensity of 1930 W/cm2 (spatial-average, temporal-average) until conduction block was achieved. Survival endpoints were 0, 7, or 14 days after HIFU treatment, at which point the nerve conduction was assessed. Qualitative and quantitative histological analysis of nerve sections proximal and distal to the HIFU site was performed. Conduction block of all 12 nerves was achieved with average HIFU treatment time of 10.5±4.9 s (mean±SD). The volume of necrosis of adjacent muscle was measured to be 1.59±1.1 cm3 (mean±SD). For all nerves, conduction block remained at the survival endpoint and the block resulted in degeneration of axons distal to the HIFU site, as confirmed by electrophysiological and histological methods. Potential clinical applications include treatment of spasticity in patients with spinal cord injury or pain in cancer patients.
- 27 October 2006
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 35 (1) , 109-119
Image-Guided High-Intensity Focused Ultrasound for Conduction Block of Peripheral Nerves
The objective of our work has been to investigate the use of ultrasound image-guided high-intensity focused ultrasound (HIFU) to non-invasively produce conduction block in rabbit sciatic nerves in vivo, a technique that could become a treatment of spasticity and pain. The work reported here involved the investigation of the duration of such conduction blocks after HIFU treatment and whether they resulted in axon degeneration. The right sciatic nerves of 12 rabbits were treated, under guidance of ultrasound imaging, with repeated 5-s applications of 3.2 MHz HIFU with in situ intensity of 1930 W/cm2 (spatial-average, temporal-average) until conduction block was achieved. Survival endpoints were 0, 7, or 14 days after HIFU treatment, at which point the nerve conduction was assessed. Qualitative and quantitative histological analysis of nerve sections proximal and distal to the HIFU site was performed. Conduction block of all 12 nerves was achieved with average HIFU treatment time of 10.5±4.9 s (mean±SD). The volume of necrosis of adjacent muscle was measured to be 1.59±1.1 cm3 (mean±SD). For all nerves, conduction block remained at the survival endpoint and the block resulted in degeneration of axons distal to the HIFU site, as confirmed by electrophysiological and histological methods. Potential clinical applications include treatment of spasticity in patients with spinal cord injury or pain in cancer patients.
- 1 August 2001
- Published by Annual Reviews in Annual Review of Biomedical Engineering
- Vol. 3 (1) , 375-390
Image-Guided Acoustic Therapy
▪ Abstract The potential role of therapeutic ultrasound in medicine is promising. Currently, medical devices are being developed that utilize high-intensity focused ultrasound as a noninvasive method to treat tumors and to stop bleeding (hemostasis). The primary advantage of ultrasound that lends the technique so readily to use in noninvasive therapy is its ability to penetrate deep into the body and deliver to a specific site thermal or mechanical energy with submillimeter accuracy. Realizing the full potential of acoustic therapy, however, requires precise targeting and monitoring. Fortunately, several imaging modalities can be utilized for this purpose, thus leading to the concept of image-guided acoustic therapy. This article presents a review of high-intensity focused ultrasound therapy, including its mechanisms of action, the imaging modalities used for guidance and monitoring, some current applications, and the requirements and technology associated with this exciting and promising field.
- 1 August 2001
- Published by Annual Reviews in Annual Review of Biomedical Engineering
- Vol. 3 (1) , 375-390
Image-Guided Acoustic Therapy
▪ Abstract The potential role of therapeutic ultrasound in medicine is promising. Currently, medical devices are being developed that utilize high-intensity focused ultrasound as a noninvasive method to treat tumors and to stop bleeding (hemostasis). The primary advantage of ultrasound that lends the technique so readily to use in noninvasive therapy is its ability to penetrate deep into the body and deliver to a specific site thermal or mechanical energy with submillimeter accuracy. Realizing the full potential of acoustic therapy, however, requires precise targeting and monitoring. Fortunately, several imaging modalities can be utilized for this purpose, thus leading to the concept of image-guided acoustic therapy. This article presents a review of high-intensity focused ultrasound therapy, including its mechanisms of action, the imaging modalities used for guidance and monitoring, some current applications, and the requirements and technology associated with this exciting and promising field.
- 1 January 2001
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 27 (1) , 33-42
Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging
- 1 January 2001
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 27 (1) , 33-42
Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging
- 1 September 1999
- Published by Wolters Kluwer Health in The Journal of Trauma: Injury, Infection, and Critical Care
- Vol. 47 (3) , 521-525
Control of Splenic Bleeding by Using High Intensity Ultrasound
High-intensity focused ultrasound (HIFU) has been shown to control bleeding from liver incisions, and blood vessel punctures and incisions. The objective of the current study was to investigate the capability of HIFU to stop bleeding from splenic injuries in a pig model. Surgical incisions, 25 to 50 mm in length and 2 to 8 mm in depth, were made in the spleens of five anesthetized pigs. HIFU with a frequency of 5 MHz was applied within 5 seconds of making the incision. A total of 39 incisions and HIFU treatments were performed. Bleeding from all incisions was stopped completely after HIFU treatment. The average times to control and completely arrest the hemorrhage were 28 and 55 seconds, respectively. The mechanisms of hemostasis appeared to be thermally induced coagulation necrosis of splenic tissue and occlusion of blood vessels by a mechanically induced homogenized splenic tissue. HIFU may provide a useful method of hemostasis for actively bleeding spleen. Because of its ability to induce hemostasis at adjustable depth, HIFU may prove to be a useful cauterization method both in the operating room and for patients who are managed nonoperatively.
- 1 September 1999
- Published by Wolters Kluwer Health in The Journal of Trauma: Injury, Infection, and Critical Care
- Vol. 47 (3) , 521-525
Control of Splenic Bleeding by Using High Intensity Ultrasound
High-intensity focused ultrasound (HIFU) has been shown to control bleeding from liver incisions, and blood vessel punctures and incisions. The objective of the current study was to investigate the capability of HIFU to stop bleeding from splenic injuries in a pig model. Surgical incisions, 25 to 50 mm in length and 2 to 8 mm in depth, were made in the spleens of five anesthetized pigs. HIFU with a frequency of 5 MHz was applied within 5 seconds of making the incision. A total of 39 incisions and HIFU treatments were performed. Bleeding from all incisions was stopped completely after HIFU treatment. The average times to control and completely arrest the hemorrhage were 28 and 55 seconds, respectively. The mechanisms of hemostasis appeared to be thermally induced coagulation necrosis of splenic tissue and occlusion of blood vessels by a mechanically induced homogenized splenic tissue. HIFU may provide a useful method of hemostasis for actively bleeding spleen. Because of its ability to induce hemostasis at adjustable depth, HIFU may prove to be a useful cauterization method both in the operating room and for patients who are managed nonoperatively.