Cristina González-Gonzalo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cristina González-Gonzalo has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Clara I. Sánchez
Eye Lab, qurAI Group, Informatics Institute, University of Amsterdam, Amsterdam, the Netherlands; Department of Biomedical Engineering and Physics, Amsterdam University Medical Center, Amsterdam, the Netherlands
4 shared publicationsArtin Domanian
Department of Ophthalmology, Radboud University Medical Center, Nijmegen, The Netherlands
2 shared publicationsBram van Ginneken
Diagnostic Image Analysis Group, Radboud University Medical Center, Nijmegen, The Netherlands
2 shared publicationsYara T. Lechanteur
Department of Ophthalmology, Radboud University Medical Center, Nijmegen, The Netherlands
2 shared publicationsAaron Y. Lee
Department of Ophthalmology, School of Medicine, University of Washington, Seattle, WA, USA
1 shared publication- Abdulrahman Alsaedi
Ophthalmology, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 1 September 2022
- Published by Elsevier in Progress in Retinal and Eye Research
- Vol. 90, 101034
Trustworthy AI: Closing the gap between development and integration of AI systems in ophthalmic practice
- 1 September 2022
- Published by Elsevier in Progress in Retinal and Eye Research
- Vol. 90, 101034
Top Cited PapersOpen AccessTrustworthy AI: Closing the gap between development and integration of AI systems in ophthalmic practice
- Open Access
- 1 June 2021
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 226, 1-12
Quantification of Key Retinal Features in Early and Late Age-Related Macular Degeneration Using Deep Learning
- 1 June 2021
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 226, 1-12
Open AccessQuantification of Key Retinal Features in Early and Late Age-Related Macular Degeneration Using Deep Learning
- Open Access
- 28 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (11) , 3499-3511
Iterative Augmentation of Visual Evidence for Weakly-Supervised Lesion Localization in Deep Interpretability Frameworks: Application to Color Fundus Images
Interpretability of deep learning (DL) systems is gaining attention in medical imaging to increase experts’ trust in the obtained predictions and facilitate their integration in clinical settings. We propose a deep visualization method to generate interpretability of DL classification tasks in medical imaging by means of visual evidence augmentation. The proposed method iteratively unveils abnormalities based on the prediction of a classifier trained only with image-level labels. For each image, initial visual evidence of the prediction is extracted with a given visual attribution technique. This provides localization of abnormalities that are then removed through selective inpainting. We iteratively apply this procedure until the system considers the image as normal. This yields augmented visual evidence, including less discriminative lesions which were not detected at first but should be considered for final diagnosis. We apply the method to grading of two retinal diseases in color fundus images: diabetic retinopathy (DR) and age-related macular degeneration (AMD).We evaluate the generated visual evidence and the performance of weakly-supervised localization of different types of DR and AMD abnormalities, both qualitatively and quantitatively. We show that the augmented visual evidence of the predictions highlights the biomarkers considered by experts for diagnosis and improves the final localization performance. It results in a relative increase of 11.2±2.0% per image regarding sensitivity averaged at 10 false positives/image on average, when applied to different classification tasks, visual attribution techniques and network architectures. This makes the proposed method a useful tool for exhaustive visual support of DL classifiers in medical imaging.
- 28 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (11) , 3499-3511
Open AccessIterative Augmentation of Visual Evidence for Weakly-Supervised Lesion Localization in Deep Interpretability Frameworks: Application to Color Fundus Images
Interpretability of deep learning (DL) systems is gaining attention in medical imaging to increase experts’ trust in the obtained predictions and facilitate their integration in clinical settings. We propose a deep visualization method to generate interpretability of DL classification tasks in medical imaging by means of visual evidence augmentation. The proposed method iteratively unveils abnormalities based on the prediction of a classifier trained only with image-level labels. For each image, initial visual evidence of the prediction is extracted with a given visual attribution technique. This provides localization of abnormalities that are then removed through selective inpainting. We iteratively apply this procedure until the system considers the image as normal. This yields augmented visual evidence, including less discriminative lesions which were not detected at first but should be considered for final diagnosis. We apply the method to grading of two retinal diseases in color fundus images: diabetic retinopathy (DR) and age-related macular degeneration (AMD).We evaluate the generated visual evidence and the performance of weakly-supervised localization of different types of DR and AMD abnormalities, both qualitatively and quantitatively. We show that the augmented visual evidence of the predictions highlights the biomarkers considered by experts for diagnosis and improves the final localization performance. It results in a relative increase of 11.2±2.0% per image regarding sensitivity averaged at 10 false positives/image on average, when applied to different classification tasks, visual attribution techniques and network architectures. This makes the proposed method a useful tool for exhaustive visual support of DL classifiers in medical imaging.
- Open Access
- 26 November 2019
- Published by Wiley in Acta Ophthalmologica
- Vol. 98 (4) , 368-377
Evaluation of a deep learning system for the joint automated detection of diabetic retinopathy and age‐related macular degeneration
Purpose: To validate the performance of a commercially available, CE‐certified deep learning (DL) system, RetCAD v.1.3.0 (Thirona, Nijmegen, The Netherlands), for the joint automatic detection of diabetic retinopathy (DR) and age‐related macular degeneration (AMD) in colour fundus (CF) images on a dataset with mixed presence of eye diseases.Methods: Evaluation of joint detection of referable DR and AMD was performed on a DR‐AMD dataset with 600 images acquired during routine clinical practice, containing referable and non‐referable cases of both diseases. Each image was graded for DR and AMD by an experienced ophthalmologist to establish the reference standard (RS), and by four independent observers for comparison with human performance. Validation was furtherly assessed on Messidor (1200 images) for individual identification of referable DR, and the Age‐Related Eye Disease Study (AREDS) dataset (133 821 images) for referable AMD, against the corresponding RS.Results: Regarding joint validation on the DR‐AMD dataset, the system achieved an area under the ROC curve (AUC) of 95.1% for detection of referable DR (SE = 90.1%, SP = 90.6%). For referable AMD, the AUC was 94.9% (SE = 91.8%, SP = 87.5%). Average human performance for DR was SE = 61.5% and SP = 97.8%; for AMD, SE = 76.5% and SP = 96.1%. Regarding detection of referable DR in Messidor, AUC was 97.5% (SE = 92.0%, SP = 92.1%); for referable AMD in AREDS, AUC was 92.7% (SE = 85.8%, SP = 86.0%).Conclusion: The validated system performs comparably to human experts at simultaneous detection of DR and AMD. This shows that DL systems can facilitate access to joint screening of eye diseases and become a quick and reliable support for ophthalmological experts.
- 26 November 2019
- Published by Wiley in Acta Ophthalmologica
- Vol. 98 (4) , 368-377
Open AccessEvaluation of a deep learning system for the joint automated detection of diabetic retinopathy and age‐related macular degeneration
Purpose: To validate the performance of a commercially available, CE‐certified deep learning (DL) system, RetCAD v.1.3.0 (Thirona, Nijmegen, The Netherlands), for the joint automatic detection of diabetic retinopathy (DR) and age‐related macular degeneration (AMD) in colour fundus (CF) images on a dataset with mixed presence of eye diseases.Methods: Evaluation of joint detection of referable DR and AMD was performed on a DR‐AMD dataset with 600 images acquired during routine clinical practice, containing referable and non‐referable cases of both diseases. Each image was graded for DR and AMD by an experienced ophthalmologist to establish the reference standard (RS), and by four independent observers for comparison with human performance. Validation was furtherly assessed on Messidor (1200 images) for individual identification of referable DR, and the Age‐Related Eye Disease Study (AREDS) dataset (133 821 images) for referable AMD, against the corresponding RS.Results: Regarding joint validation on the DR‐AMD dataset, the system achieved an area under the ROC curve (AUC) of 95.1% for detection of referable DR (SE = 90.1%, SP = 90.6%). For referable AMD, the AUC was 94.9% (SE = 91.8%, SP = 87.5%). Average human performance for DR was SE = 61.5% and SP = 97.8%; for AMD, SE = 76.5% and SP = 96.1%. Regarding detection of referable DR in Messidor, AUC was 97.5% (SE = 92.0%, SP = 92.1%); for referable AMD in AREDS, AUC was 92.7% (SE = 85.8%, SP = 86.0%).Conclusion: The validated system performs comparably to human experts at simultaneous detection of DR and AMD. This shows that DL systems can facilitate access to joint screening of eye diseases and become a quick and reliable support for ophthalmological experts.
- Open Access
Evaluation of a deep learning system for the joint automated detection of diabetic retinopathy and age-related macular degeneration
Purpose: To validate the performance of a commercially-available, CE-certified deep learning (DL) system, RetCAD v.1.3.0 (Thirona, Nijmegen, The Netherlands), for the joint automatic detection of diabetic retinopathy (DR) and age-related macular degeneration (AMD) in color fundus (CF) images on a dataset with mixed presence of eye diseases. Methods: Evaluation of joint detection of referable DR and AMD was performed on a DR-AMD dataset with 600 images acquired during routine clinical practice, containing referable and non-referable cases of both diseases. Each image was graded for DR and AMD by an experienced ophthalmologist to establish the reference standard (RS), and by four independent observers for comparison with human performance. Validation was furtherly assessed on Messidor (1200 images) for individual identification of referable DR, and the Age-Related Eye Disease Study (AREDS) dataset (133821 images) for referable AMD, against the corresponding RS. Results: Regarding joint validation on the DR-AMD dataset, the system achieved an area under the ROC curve (AUC) of 95.1% for detection of referable DR (SE=90.1%, SP=90.6%). For referable AMD, the AUC was 94.9% (SE=91.8%, SP=87.5%). Average human performance for DR was SE=61.5% and SP=97.8%; for AMD, SE=76.5% and SP=96.1%. Regarding detection of referable DR in Messidor, AUC was 97.5% (SE=92.0%, SP=92.1%); for referable AMD in AREDS, AUC was 92.7% (SE=85.8%, SP=86.0%). Conclusions: The validated system performs comparably to human experts at simultaneous detection of DR and AMD. This shows that DL systems can facilitate access to joint screening of eye diseases and become a quick and reliable support for ophthalmological experts.
Open AccessEvaluation of a deep learning system for the joint automated detection of diabetic retinopathy and age-related macular degeneration
Purpose: To validate the performance of a commercially-available, CE-certified deep learning (DL) system, RetCAD v.1.3.0 (Thirona, Nijmegen, The Netherlands), for the joint automatic detection of diabetic retinopathy (DR) and age-related macular degeneration (AMD) in color fundus (CF) images on a dataset with mixed presence of eye diseases. Methods: Evaluation of joint detection of referable DR and AMD was performed on a DR-AMD dataset with 600 images acquired during routine clinical practice, containing referable and non-referable cases of both diseases. Each image was graded for DR and AMD by an experienced ophthalmologist to establish the reference standard (RS), and by four independent observers for comparison with human performance. Validation was furtherly assessed on Messidor (1200 images) for individual identification of referable DR, and the Age-Related Eye Disease Study (AREDS) dataset (133821 images) for referable AMD, against the corresponding RS. Results: Regarding joint validation on the DR-AMD dataset, the system achieved an area under the ROC curve (AUC) of 95.1% for detection of referable DR (SE=90.1%, SP=90.6%). For referable AMD, the AUC was 94.9% (SE=91.8%, SP=87.5%). Average human performance for DR was SE=61.5% and SP=97.8%; for AMD, SE=76.5% and SP=96.1%. Regarding detection of referable DR in Messidor, AUC was 97.5% (SE=92.0%, SP=92.1%); for referable AMD in AREDS, AUC was 92.7% (SE=85.8%, SP=86.0%). Conclusions: The validated system performs comparably to human experts at simultaneous detection of DR and AMD. This shows that DL systems can facilitate access to joint screening of eye diseases and become a quick and reliable support for ophthalmological experts.