GMGiorgia Milotta

Giorgia Milotta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Giorgia Milotta has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Radhouene Neji

    School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ Hospital (3rd Floor - Lambeth Wing), London, UK

    5 shared publications
  • Claudia Prieto

    School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ Hospital (3rd Floor - Lambeth Wing), London, UK

    4 shared publications
  • Aurélien Bustin

    IHU LIRYC, Heart Rhythm Disease Institute, Hôpital Xavier Arnozan, Université de Bordeaux—INSERM U1045 , Avenue du Haut Lévêque, Pessac 33604

    3 shared publications
  • Rene Michael Botnar

    School of Biomedical Engineering and Imaging Sciences King's College London London UK

    3 shared publications
  • Giulia Ginami

    School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom

    2 shared publications
  • René M. Botnar

    School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ Hospital (3rd Floor - Lambeth Wing), London, UK

    2 shared publications

Latest Publications

  • Open Access

    In vivo Multi-Parameter Mapping of the Habenula using MRI

    by Giorgia Milotta, Isobel Green, Jonathan P Roiser, Martina F. Callaghan

    The habenula is a small, epithalamic brain structure situated between the mediodorsal thalamus and the third ventricle, rostral to the posterior commissure. It plays an important role in the reward circuitry of the brain and is implicated in psychiatric conditions, such as depression. The importance of the habenula for human cognition and mental health make it a key structure of interest for neuroimaging studies However, relatively few studies have been conducted in humans to characterize its physical properties using magnetic resonance imaging as habenula visualization in vivo is challenging, primarily due to its subcortical location and small size. To date, microstructural characterization of the habenula has focused on QSM. In this work we complement this characterization with measures of longitudinal and effective transverse relaxation rates, proton density and magnetisation transfer saturation using a high-resolution quantitative multi-parametric mapping protocol at 3T, in a cohort of 26 healthy participants. The habenula was most clearly visualised on the R1 maps, with highest CNR for each participant. However, its boundaries were consistent across the different parameter maps. We have provided a quantitative multi-parametric characterization which sets baseline measurements that may be useful for sequence optimization to further enhance visualisation, and provide reference values for future studies investigating pathological differences in habenula microstructure.

  • Open Access

    Mitigating the impact of flip angle and orientation dependence in single compartment R2* estimates via 2‐pool modeling

    by Giorgia Milotta, Nadège Corbin, Christian Lambert, Antoine Lutti, Siawoosh Mohammadi, Martina F. Callaghan

    Purpose: The effective transverse relaxation rate () is influenced by biological features that make it a useful means of probing brain microstructure. However, confounding factors such as dependence on flip angle (α) and fiber orientation with respect to the main field () complicate interpretation. The α‐ and ‐dependence stem from the existence of multiple sub‐voxel micro‐environments (e.g., myelin and non‐myelin water compartments). Ordinarily, it is challenging to quantify these sub‐compartments; therefore, neuroscientific studies commonly make the simplifying assumption of a mono‐exponential decay obtaining a single estimate per voxel. In this work, we investigated how the multi‐compartment nature of tissue microstructure affects single compartment estimates.Methods: We used 2‐pool (myelin and non‐myelin water) simulations to characterize the bias in single compartment estimates. Based on our numeric observations, we introduced a linear model that partitions into α‐dependent and α‐independent components and validated this in vivo at 7T. We investigated the dependence of both components on the sub‐compartment properties and assessed their robustness, orientation dependence, and reproducibility empirically.Results: increased with myelin water fraction and residency time leading to a linear dependence on α. We observed excellent agreement between our numeric and empirical results. Furthermore, the α‐independent component of the proposed linear model was robust to the choice of α and reduced dependence on fiber orientation, although it suffered from marginally higher noise sensitivity.Conclusion: We have demonstrated and validated a simple approach that mitigates flip angle and orientation biases in single‐compartment estimates.


  • Open Access

    3D whole-heart grey-blood late gadolinium enhancement cardiovascular magnetic resonance imaging

    by Giorgia Milotta, Camila Munoz, Karl P. Kunze, Radhouene Neji, Stefano Figliozzi, Amedeo Chiribiri, Reza Hajhosseiny, Pier Giorgio Masci, Claudia Prieto, René M. Botnar


  • Open Access

    3D whole‐heart isotropic‐resolution motion‐compensated joint T1/T2 mapping and water/fat imaging

    by Giorgia Milotta, Aurelien Bustin, Olivier Jaubert, Radhouene Neji, Claudia Prieto, René M. Botnar

    Purpose: To develop a free‐breathing isotropic‐resolution whole‐heart joint T1 and T2 mapping sequence with Dixon‐encoding that provides coregistered 3D T1 and T2 maps and complementary 3D anatomical water and fat images in a single ~9 min scan.Methods: Four interleaved dual‐echo Dixon gradient echo volumes are acquired with a variable density Cartesian trajectory and different preparation pulses: 1) inversion recovery‐preparation, 2) and 3) no preparations, and 4) T2 preparation. Image navigators are acquired to correct each echo for 2D translational respiratory motion; the 8 echoes are jointly reconstructed with a low‐rank patch‐based reconstruction. A water/fat separation algorithm is used to obtain water and fat images for each acquired volume. T1 and T2 maps are generated by matching the signal evolution of the water images to a simulated dictionary. Complementary bright‐blood and fat volumes for anatomical visualization are obtained from the T2‐prepared dataset. The proposed sequence was tested in phantom experiments and 10 healthy subjects and compared to standard 2D MOLLI T1 mapping, 2D balance steady‐state free precession T2 mapping, and 3D T2‐prepared Dixon coronary MR angiography.Results: High linear correlation was found between T1 and T2 quantification with the proposed approach and phantom spin echo measurements (y = 1.1 × −11.68, R2 = 0.98; and y = 0.85 × +5.7, R2 = 0.99). Mean myocardial values of T1/T2 = 1116 ± 30.5 ms/45.1 ± 2.38 ms were measured in vivo. Biases of T1/T2 = 101.8 ms/−0.77 ms were obtained compared to standard 2D techniques.Conclusion: The proposed joint T1/T2 sequence permitted the acquisition of motion‐compensated isotropic‐resolution 3D T1 and T2 maps and complementary coronary MR angiography and fat volumes, showing promising results in terms of T1 and T2 quantification and visualization of cardiac anatomy and pericardial fat.


  • Open Access

    3D Whole‐heart free‐breathing qBOOST‐T2 mapping

    by Giorgia Milotta, Giulia Ginami, Aurelien Bustin, Radhouene Neji, Claudia Prieto, René M. Botnar

    Purpose: To develop an accelerated motion corrected 3D whole‐heart imaging approach (qBOOST‐T2) for simultaneous high‐resolution bright‐ and black‐blood cardiac MR imaging and quantitative myocardial T2 characterization.Methods: Three undersampled interleaved balanced steady‐state free precession cardiac MR volumes were acquired with a variable density Cartesian trajectory and different magnetization preparations: (1) T2‐prepared inversion recovery (T2prep‐IR), (2) T2‐preparation, and (3) no preparation. Image navigators were acquired prior the acquisition to correct for 2D translational respiratory motion. Each 3D volume was reconstructed with a low‐rank patch‐based reconstruction. The T2prep‐IR volume provides bright‐blood anatomy visualization, the black‐blood volume is obtained by means of phase sensitive reconstruction between first and third datasets, and T2 maps are generated by matching the signal evolution to a simulated dictionary. The proposed sequence has been evaluated in simulations, phantom experiments, 11 healthy subjects and compared with 3D bright‐blood cardiac MR and standard 2D breath‐hold balanced steady‐state free precession T2 mapping. The feasibility of the proposed approach was tested on 4 patients with suspected cardiovascular disease.Results: High linear correlation (y = 1.09 × −0.83, R2 = 0.99) was found between the proposed qBOOST‐T2 and T2 spin echo measurements in phantom experiment. Good image quality was observed in vivo with the proposed 4x undersampled qBOOST‐T2. Mean T2 values of 53.1 ± 2.1 ms and 55.8 ± 2.7 ms were measured in vivo for 2D balanced steady‐state free precession T2 mapping and qBOOST‐T2, respectively, with linear correlation of y = 1.02x+1.46 (R2 = 0.61) and T2 bias = 2.7 ms.Conclusion: The proposed qBOOST‐T2 sequence allows the acquisition of 3D high‐resolution co‐registered bright‐ and black‐blood volumes and T2 maps in a single scan of ~11 min, showing promising results in terms of T2 quantification.


  • Open Access

    Accelerated free‐breathing whole‐heart 3D T2 mapping with high isotropic resolution

    by Aurélien Bustin, Giorgia Milotta, Tevfik F. Ismail, Radhouene Neji, René M. Botnar, Claudia Prieto

    Purpose: To enable free‐breathing whole‐heart 3D T2 mapping with high isotropic resolution in a clinically feasible and predictable scan time. This 3D motion‐corrected undersampled signal matched (MUST) T2 map is achieved by combining an undersampled motion‐compensated T2‐prepared Cartesian acquisition with a high‐order patch‐based reconstruction.Methods: The 3D MUST‐T2 mapping acquisition consists of an electrocardiogram‐triggered, T2‐prepared, balanced SSFP sequence with nonselective saturation pulses. Three undersampled T2‐weighted volumes are acquired using a 3D Cartesian variable‐density sampling with increasing T2 preparation times. A 2D image‐based navigator is used to correct for respiratory motion of the heart and allow 100% scan efficiency. Multicontrast high‐dimensionality undersampled patch‐based reconstruction is used in concert with dictionary matching to generate 3D T2 maps. The proposed framework was evaluated in simulations, phantom experiments, and in vivo (10 healthy subjects, 2 patients) with 1.5‐mm3 isotropic resolution. Three‐dimensional MUST‐T2 was compared against standard multi‐echo spin‐echo sequence (phantom) and conventional breath‐held single‐shot 2D SSFP T2 mapping (in vivo).Results: Three‐dimensional MUST‐T2 showed high accuracy in phantom experiments (R2 > 0.99). The precision of T2 values was similar for 3D MUST‐T2 and 2D balanced SSFP T2 mapping in vivo (5 ± 1 ms versus 4 ± 2 ms, P = .52). Slightly longer T2 values were observed with 3D MUST‐T2 in comparison to 2D balanced SSFP T2 mapping (50.7 ± 2 ms versus 48.2 ± 1 ms, P < .05). Preliminary results in patients demonstrated T2 values in agreement with literature values.Conclusion: The proposed approach enables free‐breathing whole‐heart 3D T2 mapping with high isotropic resolution in about 8 minutes, achieving accurate and precise T2 quantification of myocardial tissue in a clinically feasible scan time.


  • Simultaneous 3D whole‐heart bright‐blood and black blood imaging for cardiovascular anatomy and wall assessment with interleaved T2prep‐IR

    by Giorgia Milotta, Giulia Ginami, Gastao Cruz, Radhouene Neji, Claudia Prieto, René M. Botnar

    Purpose: To develop a motion‐corrected 3D flow‐insensitive imaging approach interleaved T2 prepared‐inversion recovery (iT2prep‐IR) for simultaneous lumen and wall visualization of the great thoracic vessels and cardiac structures.Methods: A 3D flow‐insensitive approach for simultaneous cardiovascular lumen and wall visualization (iT2prep) has been previously proposed. This approach requires subject‐dependent weighted subtraction to completely null the arterial blood signal in the black‐blood volume. Here, we propose an (T2prep‐IR) approach to improve wall visualization and remove need for weighted subtraction. The proposed sequence is based on the acquisition and direct subtraction of 2 interleaved 3D whole‐heart data sets acquired with and without T2prep‐IR preparation. Image navigators are acquired before data acquisition to enable 2D translational and 3D non‐rigid motion correction allowing 100% respiratory scan efficiency. The proposed approach was evaluated in 10 healthy subjects and compared with the conventional 2D double inversion recovery (DIR) sequence and the 3D iT2prep sequence. Additionally, 5 patients with congenital heart disease were acquired to test the clinical feasibility of the proposed approach.Results: The proposed iT2prep‐IR sequence showed improved blood nulling compared to both DIR and iT2prep techniques in terms of SNR (SNRblood = 6.9, 12.2, and 18.2, respectively) and contrast‐to‐noise‐ratio (CNRmyoc‐blood = 28.4, 15.4, and 15.3, respectively). No statistical difference was observed between iT2prep‐IR, iT2prep and DIR atrial and ventricular wall thickness quantification.Conclusion: The proposed interleaved T2prep‐IR sequence enables the simultaneous lumen and wall visualization of cardiac structures and shows promising results in terms of SNR, CNR, and wall thickness measurement.