JWJun Wei

Jun Wei

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jun Wei has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Synthesizing mammogram from digital breast tomosynthesis

    by Jun Wei, Heang-Ping Chan, Mark A Helvie, Marilyn A Roubidoux, Colleen H Neal, Yao Lu, Lubomir M Hadjiiski, Chuan Zhou

    The purpose of this study is to develop a new method for generating synthesized mammogram (SM) from digital breast tomosynthesis (DBT) and to assess its potential as an adjunct to DBT. We first applied multiscale bilateral filtering to the reconstructed DBT slices to enhance the high-frequency features and reduce noise. A maximum intensity projection (MIP) image was then obtained from the high-frequency components of the DBT slices. A multiscale image fusion method was designed to combine the MIP image and the central DBT projection view into an SM and further enhance the high-frequency features. We conducted a pilot reader study to visually assess the image quality of SM in comparison to full field digital mammograms (FFDM). For each DBT craniocaudal or mediolateral view, a clinical FFDM of the corresponding view was retrospectively collected. Three MQSA radiologists, blinded to the pathological and other clinical information, independently interpreted the SM and the corresponding FFDM side by side marked with the lesion locations. The differences in the BI-RADS assessments of both MCs and masses between SM and FFDM did not achieve statistical significance for all three readers. The conspicuity of MCs on SM was superior to that on FFDM and the BI-RADS assessments of MCs were comparable while the conspicuity of masses on SM was degraded and interpretation on SM was less accurate than that on FFDM. The SM may be useful for efficient prescreening of MCs in DBT but the DBT should be used for detection and characterization of masses.


  • Open Access

    Computer-aided assessment of breast density: comparison of supervised deep learning and feature-based statistical learning

    by Songfeng Li, Jun Wei, Heang-Ping Chan, Mark A Helvie, Marilyn A Roubidoux, Yao Lu, Chuan Zhou, Lubomir M Hadjiiski, Ravi K Samala

    Breast density is one of the most significant factors that is associated with cancer risk. In this study, our purpose was to develop a supervised deep learning approach for automated estimation of percentage density (PD) on digital mammograms (DMs). The input ‘for processing’ DMs was first log-transformed, enhanced by a multi-resolution preprocessing scheme, and subsampled to a pixel size of 800 µ m × 800 µ m from 100 µ m × 100 µ m. A deep convolutional neural network (DCNN) was trained to estimate a probability map of breast density (PMD) by using a domain adaptation resampling method. The PD was estimated as the ratio of the dense area to the breast area based on the PMD. The DCNN approach was compared to a feature-based statistical learning approach. Gray level, texture and morphological features were extracted and a least absolute shrinkage and selection operator was used to combine the features into a feature-based PMD. With approval of the Institutional Review Board, we retrospectively collected a training set of 478 DMs and an independent test set of 183 DMs from patient files in our institution. Two experienced mammography quality standards act radiologists interactively segmented PD as the reference standard. Ten-fold cross-validation was used for model selection and evaluation with the training set. With cross-validation, DCNN obtained a Dice’s coefficient (DC) of 0.79 ± 0.13 and Pearson’s correlation ( r ) of 0.97, whereas feature-based learning obtained DC = 0.72 ± 0.18 and r = 0.85. For the independent test set, DCNN achieved DC = 0.76 ± 0.09 and r = 0.94, while feature-based learning achieved DC = 0.62 ± 0.21 and r = 0.75. Our DCNN approach was significantly better and more robust than the feature-based learning approach for automated PD estimation on DMs, demonstrating its potential use for automated density reporting as well as for model-based risk prediction.


  • Computerized detection of noncalcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis

    by Jun Wei, Chuan Zhou, Heang‐Ping Chan, Aamer Chughtai, Prachi Agarwal, Jean Kuriakose, Lubomir Hadjiiski, Smita Patel, Ella Kazerooni

    Purpose: The buildup of noncalcified plaques (NCPs) that are vulnerable to rupture in coronary arteries is a risk for myocardial infarction. Interpretation of coronary CT angiography (cCTA) to search for NCP is a challenging task for radiologists due to the low CT number of NCP, the large number of coronary arteries, and multiple phase CT acquisition. The authors conducted a preliminary study to develop machine learning method for automated detection of NCPs in cCTA.Methods: With IRB approval, a data set of 83 ECG‐gated contrast enhanced cCTA scans with 120 NCPs was collected retrospectively from patient files. A multiscale coronary artery response and rolling balloon region growing (MSCAR‐RBG) method was applied to each cCTA volume to extract the coronary arterial trees. Each extracted vessel was reformatted to a straightened volume composed of cCTA slices perpendicular to the vessel centerline. A topological soft‐gradient (TSG) detection method was developed to prescreen for NCP candidates by analyzing the 2D topological features of the radial gradient field surface along the vessel wall. The NCP candidates were then characterized by a luminal analysis that used 3D geometric features to quantify the shape information and gray‐level features to evaluate the density of the NCP candidates. With machine learning techniques, useful features were identified and combined into an NCP score to differentiate true NCPs from false positives (FPs). To evaluate the effectiveness of the image analysis methods, the authors performed tenfold cross‐validation with the available data set. Receiver operating characteristic (ROC) analysis was used to assess the classification performance of individual features and the NCP score. The overall detection performance was estimated by free response ROC (FROC) analysis.Results: With our TSG prescreening method, a prescreening sensitivity of 92.5% (111/120) was achieved with a total of 1181 FPs (14.2 FPs/scan). On average, six features were selected during the tenfold cross‐validation training. The average area under the ROC curve (AUC) value for training was 0.87 ± 0.01 and the AUC value for validation was 0.85 ± 0.01. Using the NCP score, FROC analysis of the validation set showed that the FP rates were reduced to 3.16, 1.90, and 1.39 FPs/scan at sensitivities of 90%, 80%, and 70%, respectively.Conclusions: The topological soft‐gradient prescreening method in combination with the luminal analysis for FP reduction was effective for detection of NCPs in cCTA, including NCPs causing positive or negative vessel remodeling. The accuracy of vessel segmentation, tracking, and centerline identification has a strong impact on NCP detection. Studies are underway to further improve these techniques and reduce the FPs of the CADe system.


  • Multichannel response analysis on 2D projection views for detection of clustered microcalcifications in digital breast tomosynthesis

    by Jun Wei, Heang‐Ping Chan, Lubomir M. Hadjiiski, Mark A. Helvie, Yao Lu, Chuan Zhou, Ravi Samala

    Purpose:: To investigate the feasibility of a new two‐dimensional (2D) multichannel response (MCR) analysis approach for the detection of clustered microcalcifications (MCs) in digital breast tomosynthesis (DBT).Methods:: With IRB approval and informed consent, a data set of two‐view DBTs from 42 breasts containing biopsy‐proven MC clusters was collected in this study. The authors developed a 2D approach for MC detection using projection view (PV) images rather than the reconstructed three‐dimensional (3D) DBT volume. Signal‐to‐noise ratio (SNR) enhancement processing was first applied to each PV to enhance the potential MCs. The locations of MC candidates were then identified with iterative thresholding. The individual MCs were decomposed with Hermite–Gaussian (HG) and Laguerre–Gaussian (LG) basis functions and the channelized Hotelling model was trained to produce the MCRs for each MC on the 2D images. The MCRs from the PVs were fused in 3D by a coincidence counting method that backprojects the MC candidates on the PVs and traces the coincidence of their ray paths in 3D. The 3D MCR was used to differentiate the true MCs from false positives (FPs). Finally a dynamic clustering method was used to identify the potential MC clusters in the DBT volume based on the fact that true MCs of clinical significance appear in clusters. Using two‐fold cross validation, the performance of the 3D MCR for classification of true and false MCs was estimated by the area under the receiver operating characteristic (ROC) curve and the overall performance of the MCR approach for detection of clustered MCs was assessed by free response receiver operating characteristic (FROC) analysis.Results:: When the HG basis function was used for MCR analysis, the detection of MC cluster achieved case‐based test sensitivities of 80% and 90% at the average FP rates of 0.65 and 1.55 FPs per DBT volume, respectively. With LG basis function, the average FP rates were 0.62 and 1.57 per DBT volume at the same sensitivity levels. The difference in the two sets of basis functions for detection of MCs did not show statistical significance.Conclusions:: The authorsˈ experimental results indicate that the MCR approach is promising for the detection of MCs on PV images. The HG or LG basis functions are both effective in characterizing the signal response of MCs using the channelized Hotelling model. The coincidence counting method for fusion of the 2D MCR in 3D is an important step for FP reduction. Further study is underway to improve the MCR approach for microcalcification detection in DBT.


  • Association of Computerized Mammographic Parenchymal Pattern Measure with Breast Cancer Risk: A Pilot Case-Control Study

    by Jun Wei, Heang-Ping Chan, Yi-Ta Wu, Chuan Zhou, Mark A. Helvie, Alexander Tsodikov, Lubomir M. Hadjiiski, Berkman Sahiner

    The proposed mammographic parenchymal pattern measure showed a strong association with breast cancer risk and a low correlation with percentage density and some known risk factors; it may serve as ... PurposeTo develop a computerized mammographic parenchymal pattern (MPP) measure and investigate its association with breast cancer risk.Materials and MethodsA pilot case-control study was conducted...


  • Computer‐aided detection of breast masses on mammograms: Dual system approach with two‐view analysis

    by Jun Wei, Heang‐Ping Chan, Berkman Sahiner, Chuan Zhou, Lubomir M. Hadjiiski, Marilyn A. Roubidoux, Mark A. Helvie

    Purpose: The purpose of this study is to develop a computer‐aided detection (CAD) system that combined a dual system approach with a two‐view fusion method to improve the accuracy of mass detection on mammograms.Methods: The authors previously developed a dual CAD system that merged the decision from two mass detection systems in parallel, one trained with average masses and another trained with subtle masses, to improve sensitivity without excessively increasing false positives (FPs). In this study, they further designed a two‐view fusion method to combine the information from different mammographic views. Mass candidates detected independently by the dual system on the two‐view mammograms were first identified as potential pairs based on a regional registration technique. A similarity measure was designed to differentiate TP‐TP pairs from other pairs (TP‐FP and FP‐FP pairs) using paired morphological features, Hessian feature, and texture features. A two‐view fusion score for each object was generated by weighting the similarity measure with the cross correlation measure of the object pair. Finally, a linear discriminant analysis classifier was trained to combine the mass likelihood score of the object from the single‐view dual system and the two‐view fusion score for classification of masses and FPs. A total of 2332 mammograms from 735 subjects including 800 normal mammograms from 200 normal subjects was collected with Institutional Review Board (IRB) approval.Results: When the single‐view CAD system that was trained with average masses only were applied to the test sets, the average case‐based sensitivities were 50.6% and 63.6% for average masses on current mammograms and 22.6% and 36.2% for subtle masses on prior mammograms at 0.5 and 1 FPs/image, respectively. With the new two‐view dual system approach, the average case‐based sensitivities were improved to 67.4% and 83.7% for average masses and 44.8% and 57.0% for subtle masses at the same FP rates.Conclusions: The improvement with the proposed method was found to be statistically significant by JAFROC analysis.


  • Computer-Aided Detection Systems for Breast Masses: Comparison of Performances on Full-Field Digital Mammograms and Digitized Screen-Film Mammograms

    by Jun Wei, Lubomir M. Hadjiiski, Berkman Sahiner, Heang-Ping Chan, Jun Ge, Marilyn A. Roubidoux, Mark A. Helvie, Chuan Zhou, Yi-Ta Wu, Chintana Paramagul, et al.


  • Dual system approach to computer‐aided detection of breast masses on mammograms

    by Jun Wei, Heang‐Ping Chan, Berkman Sahiner, Lubomir M. Hadjiiski, Mark A. Helvie, Marilyn A. Roubidoux, Chuan Zhou, Jun Ge

    In this study, our purpose was to improve the performance of our mass detection system by using a new dual system approach which combines a computer‐added detection (CAD) system optimized with “average” masses with another CAD system optimized with “subtle” masses. The two single CAD systems have similar image processing steps, which include prescreening, object segmentation, morphological and texture feature extraction, and false positive (FP) reduction by rule‐based and linear discriminant analysis (LDA) classifiers. A feed‐forward backpropagation artificial neural network was trained to merge the scores from the LDA classifiers in the two single CAD systems and differentiate true masses from normal tissue. For an unknown test mammogram, the two single CAD systems are applied to the image in parallel to detect suspicious objects. A total of three data sets were used for training and testing the systems. The first data set of 230 current mammograms, referred to as the average mass set, was collected from 115 patients. We also collected 264 mammograms, referred to as the subtle mass set, which were one to two years prior to the current exam from these patients. Both the average and the subtle mass sets were partitioned into two independent data sets in a cross validation training and testing scheme. A third data set containing 65 cases with 260 normal mammograms was used to estimate the FP marker rates during testing. When the single CAD system trained on the average mass set was applied to the test set with average masses, the FP marker rates were 2.2, 1.8, and 1.5 per image at the case‐based sensitivities of 90%, 85%, and 80%, respectively. With the dual CAD system, the FP marker rates were reduced to 1.2, 0.9, and 0.7 per image, respectively, at the same case‐based sensitivities. Statistically significant improvements on the free response receiver operating characteristic curves were observed when the dual system and the single system were compared using the test sets with either average masses or subtle masses.


  • Computer‐aided detection of breast masses on full field digital mammograms

    by Jun Wei, Berkman Sahiner, Lubomir M. Hadjiiski, Heang‐Ping Chan, Nicholas Petrick, Mark A. Helvie, Marilyn A. Roubidoux, Jun Ge, Chuan Zhou

    We are developing a computer‐aided detection (CAD) system for breast masses on full field digital mammographic (FFDM) images. To develop a CAD system that is independent of the FFDM manufacturer's proprietary preprocessing methods, we used the raw FFDM image as input and developed a multiresolution preprocessing scheme for image enhancement. A two‐stage prescreening method that combines gradient field analysis with gray level information was developed to identify mass candidates on the processed images. The suspicious structure in each identified region was extracted by clustering‐based region growing. Morphological and spatial gray‐level dependence texture features were extracted for each suspicious object. Stepwise linear discriminant analysis (LDA) with simplex optimization was used to select the most useful features. Finally, rule‐based and LDA classifiers were designed to differentiate masses from normal tissues. Two data sets were collected: a mass data set containing 110 cases of two‐view mammograms with a total of 220 images, and a no‐mass data set containing 90 cases of two‐view mammograms with a total of 180 images. All cases were acquired with a GE Senographe 2000D FFDM system. The true locations of the masses were identified by an experienced radiologist. Free‐response receiver operating characteristic analysis was used to evaluate the performance of the CAD system. It was found that our CAD system achieved a case‐based sensitivity of 70%, 80%, and 90% at 0.72, 1.08, and 1.82 false positive (FP) marks/image on the mass data set. The FP rates on the no‐mass data set were 0.85, 1.31, and 2.14 FP marks/image, respectively, at the corresponding sensitivities. This study demonstrated the usefulness of our CAD techniques for automated detection of masses on FFDM images.


  • Correlation between mammographic density and volumetric fibroglandular tissue estimated on breast MR images

    by Jun Wei, Heang‐Ping Chan, Mark A. Helvie, Marilyn A. Roubidoux, Berkman Sahiner, Lubomir M. Hadjiiski, Chuan Zhou, Sophie Paquerault, Thomas Chenevert, Mitchell M. Goodsitt

    Previous studies have found that mammographic breast density is highly correlated with breast cancer risk. Therefore, mammographic breast density may be considered as an important risk factor in studies of breast cancer treatments. In this paper, we evaluated the accuracy of using mammograms for estimating breast density by analyzing the correlation between the percent mammographic dense area and the percent glandular tissue volume as estimated from MR images. A dataset of 67 cases having MR images (coronal 3‐D SPGR T1‐weighted pre‐contrast) and corresponding 4‐view mammograms was used in this study. Mammographic breast density was estimated by an experienced radiologist and an automated image analysis tool, Mammography Density ESTimator (MDEST) developed previously in our laboratory. For the estimation of the percent volume of fibroglandular tissue in breast MR images, a semiautomatic method was developed to segment the fibroglandular tissue from each slice. The tissue volume was calculated by integration over all slices containing the breast. Interobserver variation was measured for 3 different readers. It was found that the correlation between every two of the three readers for segmentation of MR volumetric fibroglandular tissue was 0.99. The correlations between the percent volumetric fibroglandular tissue on MR images and the percent dense area of the CC and MLO views segmented by an experienced radiologist were both 0.91. The correlation between the percent volumetric fibroglandular tissue on MR images and the percent dense area of the CC and MLO views segmented by MDEST was 0.91 and 0.89, respectively. The root‐mean‐square (rms) residual ranged from 5.4% to 6.3%. The mean bias ranged from 3% to 6%. The high correlation indicates that changes in mammographic density may be a useful indicator of changes in fibroglandular tissue volume in the breast.