YUYoshiko Ueno

Yoshiko Ueno

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yoshiko Ueno has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Super-Resolution Deep Learning Reconstruction for 3-Dimensional T1-Weighted Gradient-Echo Imaging in Contrast-Enhanced Liver MRI: Comparison With Conventional and Standard Deep Learning Reconstructions

    by Kentaro Nishiuchi, Keitaro Sofue, Kazuma Tsukamoto, Yuichiro Somiya, Tomonari Ishida, Ryutaro Yano, Akihiko Umeno, Ryohei Kozuki, Takeru Yamaguchi, Eisuke Ueshima, et al.

    Purpose: To evaluate the image quality of super-resolution deep learning reconstruction (SR-DLR) for 3-dimensional (3D) T1-weighted gradient-echo (GRE) imaging in contrast-enhanced MRI, compared with conventional reconstruction (Conv.) and standard deep learning reconstruction (DLR). Materials and Methods: This retrospective study included 50 patients (mean age: 71.5 y) with 76 hepatic lesions who underwent contrast-enhanced dynamic liver MRI at 3T. Portal venous phase images were reconstructed using Conv., DLR, and SR-DLR. Quantitative analyses measured liver signal-to-noise ratio (SNR), contrast ratio (CR) between liver parenchyma and lesions, edge rise distance (ERD), and edge rise slope (ERS). Qualitative assessments of image noise, sharpness, contrast, motion artifacts, overall image quality, and lesion conspicuity were performed independently by 2 radiologists using a 5-point scale. Coronal multiplanar reformatted (MPR) images were also evaluated. Statistical comparisons were performed using the Friedman test with Bonferroni correction. Results: Liver SNR was comparable between SR-DLR and DLR. SR-DLR produced sharper edges (lower ERD, higher ERS) and higher lesion-to-liver CR than Conv. and DLR ( P P <0.001). SR-DLR images exhibited slightly higher image noise and motion-related artifacts than DLR. Conclusion: SR-DLR improved spatial resolution, sharpness, and lesion conspicuity in contrast-enhanced MRI compared with Conv. and DLR, indicating potential to improve the diagnostic performance of dynamic liver MRI.

  • Open Access

    Rim Enhancement on Contrast-Enhanced CT as a Predictor of Prognosis in Patients with Pancreatic Ductal Adenocarcinoma

    by Takeru Yamaguchi, Keitaro Sofue, Eisuke Ueshima, Naoki Sugiyama, Shinji Yabe, Yoshiko Ueno, Atsuhiro Masuda, Hirochika Toyama, Takayuki Kodama, Masato Komatsu, et al.

    This study investigated the utility of imaging features, such as rim enhancement on contrast-enhanced CT (CECT), in predicting the prognosis of pancreatic ductal adenocarcinoma (PDAC). This retrospective study included 158 patients (84 men; mean age, 68 years) with pathologically confirmed PDAC. The following imaging features were evaluated on CECT by two radiologists: tumor size, tumor attenuation, and the presence of rim enhancement. Cox proportional hazards analysis was performed to identify the imaging and clinicopathological features for predicting disease-free survival (DFS) and overall survival (OS). Pathological features were compared with the presence of rim enhancement. Among the 158 patients, 106 (67%) underwent curative surgery (surgery group) and 52 (33%) received conservative treatment (non-surgery group). Rim enhancement was observed more frequently in the non-surgery group than in the surgery group (44% vs. 20%; p < 0.001). Rim enhancement showed significant associations with shorter DFS and OS in the surgery group (hazard ratios (HRs), 3.03 and 2.99; p < 0.001 and p = 0.003, respectively), whereas tumor size showed significant associations with shorter OS (HR per 1 mm increase, 1.08; p < 0.001). PDACs with rim enhancement showed significant associations with higher histological tumor grades (p < 0.001). PDAC with rim enhancement on CECT could predict poorer prognosis and more aggressive tumor grades.


  • Diffusion and quantification of diffusion of prostate cancer

    by Yoshiko Ueno, Tsutomu Tamada, Keitaro Sofue, Takamichi Murakami

    For assessing a cancer treatment, and for detecting and characterizing cancer, Diffusion-weighted imaging (DWI) is commonly used. The key in DWI’s use extracranially has been due to the emergence of of high-gradient amplitude and multichannel coils, parallelimaging, and echo-planar imaging. The benefit has been fewer motion artefacts and high-quality prostate images.Recently, new techniques have been developed to improve the signal-to-noise ratio of DWI with fewer artefacts, allowing an increase in spatial resolution. For apparent diffusion coefficient quantification, non-Gaussian diffusion models have been proposed as additional tools for prostate cancer detection and evaluation of its aggressiveness. More recently, radiomics and machine learning for prostate magnetic resonance imaging have emerged as novel techniques for the non-invasive characterisation of prostate cancer. This review presents recent developments in prostate DWI and discusses its potential use in clinical practice.


  • Comparison of prostate imaging reporting and data system v2.1 and 2 in transition and peripheral zones: evaluation of interreader agreement and diagnostic performance in detecting clinically significant prostate cancer

    by Yasuyo Urase, Yoshiko Ueno, Tsutomu Tamada, Keitaro Sofue, Satoru Takahashi, Nobuyuki Hinata, Kenichi Harada, Masato Fujisawa, Takamichi Murakami

    Objective: To evaluate the interreader agreement and diagnostic performance of the Prostate Imaging Reporting and Data System (PI-RADS) v. 2.1, in comparison with v. 2. Methods: Institutional review board approval was obtained for this retrospective study. 77 consecutive patients who underwent a prostate multiparametric magnetic resonance imaging at 3.0 T before radical prostatectomy were included. Four radiologists (two experienced uroradiologists and two inexperienced radiologists) independently scored eight regions [six peripheral zones (PZ) and two transition zones (TZ)] using v. 2.1 and v. 2. Interreader agreement was assessed using κ statistics. To evaluate diagnostic performance for clinically significant prostate cancer (csPC), area under the curve (AUC) was estimated. Results: 228 regions were pathologically diagnosed as positive for csPC. With a cut-off ≥3, the agreement among all readers was better with v. 2.1 than v. 2 in TZ, PZ, or both zones combined (κ-value: TZ, 0.509 vs 0.414; PZ, 0.686 vs 0.568; both zones combined, 0.644 vs 0.531). With a cut-off ≥4, the agreement among all readers was also better with v. 2.1 than v. 2 in the PZ or both zones combined (κ-value: PZ, 0.761 vs 0.701; both zones combined, 0.756 vs 0.709). For all readers, AUC with v. 2.1 was higher than with v. 2 (TZ, 0.826–0.907 vs 0.788–0.856; PZ, 0.857–0.919 vs 0.853–0.902). Conclusion: Our study suggests that the PI-RADS v. 2.1 could improve the interreader agreement and might contribute to improved diagnostic performance compared with v. 2. Advances in knowledge: PI-RADS v. 2.1 has a potential to improve interreader variability and diagnostic performance among radiologists with different levels of expertise.


  • Open Access

    Simulation Study of Low-Dose Sparse-Sampling CT with Deep Learning-Based Reconstruction: Usefulness for Evaluation of Ovarian Cancer Metastasis

    by Yasuyo Urase, Mizuho Nishio, Yoshiko Ueno, Atsushi K. Kono, Keitaro Sofue, Tomonori Kanda, Takaki Maeda, Munenobu Nogami, Masatoshi Hori, Takamichi Murakami

    The usefulness of sparse-sampling CT with deep learning-based reconstruction for detection of metastasis of malignant ovarian tumors was evaluated. We obtained contrast-enhanced CT images (n = 141) of ovarian cancers from a public database, whose images were randomly divided into 71 training, 20 validation, and 50 test cases. Sparse-sampling CT images were calculated slice-by-slice by software simulation. Two deep-learning models for deep learning-based reconstruction were evaluated: Residual Encoder-Decoder Convolutional Neural Network (RED-CNN) and deeper U-net. For 50 test cases, we evaluated the peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) as quantitative measures. Two radiologists independently performed a qualitative evaluation for the following points: entire CT image quality; visibility of the iliac artery; and visibility of peritoneal dissemination, liver metastasis, and lymph node metastasis. Wilcoxon signed-rank test and McNemar test were used to compare image quality and metastasis detectability between the two models, respectively. The mean PSNR and SSIM performed better with deeper U-net over RED-CNN. For all items of the visual evaluation, deeper U-net scored significantly better than RED-CNN. The metastasis detectability with deeper U-net was more than 95%. Sparse-sampling CT with deep learning-based reconstruction proved useful in detecting metastasis of malignant ovarian tumors and might contribute to reducing overall CT-radiation exposure.


  • Diagnostic Accuracy and Interobserver Agreement for the Vesical Imaging-Reporting and Data System for Muscle-invasive Bladder Cancer: A Multireader Validation Study

    by Yoshiko Ueno, Mitsuru Takeuchi, Tsutomu Tamada, Keitaro Sofue, Satoru Takahashi, Yuki Kamishima, Nobuyuki Hinata, Kenichi Harada, Masato Fujisawa, Takamichi Murakami


  • Value of three-dimensional T2-weighted turbo spin-echo imaging with tissue-specific variable refocusing flip angle for 3-T magnetic resonance imaging of prostate cancer: comparison with conventional two- and three-dimensional T2-weighted turbo spin-echo imaging

    by Utaru Tanaka, Yoshiko Ueno, Yukiko Morinaga, Hideaki Miyake, Katsusuke Kyotani, Yu Ueda, Kazuhiro Kitajima, Keitaro Sofue, Yuko Suenaga, Kazuro Sugimura, et al.

    To investigate the impact of three-dimensional (3D) T2-weighted turbo spin-echo imaging (TSE-T2WI) with tissue-specific variable refocusing flip angle (TS-VRFA) on image quality and prostate cancer (PCa) detection and extraprostatic extension (EPE) evaluation compared to 2D TSE-T2WI and conventional 3D TSE-T2WI with volume isotropic TSE acquisition (VISTA).


  • Top Cited Papers

    Endometrial Carcinoma: MR Imaging–based Texture Model for Preoperative Risk Stratification—A Preliminary Analysis

    by Yoshiko Ueno, Behzad Forghani, Reza Forghani, Anthony Dohan, Xing Ziggy Zeng, Foucauld Chamming’s, Jocelyne Arseneau, Lili Fu, Lucy Gilbert, Benoit Gallix, et al.

    Mathematical modeling with MR imaging–based texture features was associated with the presence of deep myometrial invasion, lymphovascular space invasion, and high-grade tumors, and accuracy was equivalent to that of experienced subspecialty radiologists for assessment of deep myometrial invasion in a preliminary study. Purpose To evaluate the associations among mathematical modeling with the use of magnetic resonance (MR) imaging–based texture features and deep myometrial invasion (DMI), lymphovascular space invasion (LVSI), and histologic high-grade endometrial carcinoma. Materials and Methods Institutional review board approval was obtained for this retrospective study. This study included 137 women with endometrial carcinomas measuring greater than 1 cm in maximal diameter who underwent 1.5-T MR imaging before hysterectomy between January 2011 and December 2015. Texture analysis was performed with commercial research software with manual delineation of a region of interest around the tumor on MR images (T2-weighted, diffusion-weighted, and dynamic contrast material–enhanced images and apparent diffusion coefficient maps). Areas under the receiver operating characteristic curve and diagnostic performance of random forest models determined by using a subset of the most relevant texture features were estimated and compa...