LPLaura Pol

Laura Pol

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Laura Pol has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    Bilateral Globus Pallidus Deep Brain Stimulation Improves Motor Function in ADCY5 ‐Related Disorder

    by Moritz Thiel, Katerina Bernardi, Enrique Gonzalez Saez‐Diez, Joshua Rong, Nathalie Dorison, Diane Doummar, Claudia Ravelli, Laura A. van de Pol, Joke M. Dijk, Rick Schuurman, et al.

    Background: ADCY5 ‐related disorder is characterized by disabling hyperkinetic movement disorders. The therapeutic impact of deep brain stimulation ( DBS ) has not been systematically evaluated. Objectives/Methods: This work involved a multicenter cohort study of 8 children with genetically confirmed ADCY5 ‐related movement disorders treated with bilateral globus pallidus internus (GPi) DBS. Results: The mean age at initiation of DBS was 12.9 years (range: 3.5–18). All patients demonstrated improvement in baseline hyperkinesia and paroxysmal exacerbations. Mean Burke–Fahn–Marsden Dystonia Rating Scale motor scores decreased from 50.7 to 22.7 ( p = 0.019, d = 1.19). Functional gains included new or recovered motor milestones, improved speech and swallowing, and resolution of sleep‐related dyskinesias. There were no perioperative complications. Conclusions: GPi ‐ DBS is a safe and effective therapy for ADCY5 ‐related movement disorders, offering sustained motor and functional improvement. These findings support earlier consideration of DBS to reduce disease burden, preserve function, and improve long‐term outcomes. © 2026 International Parkinson and Movement Disorder Society.


  • Optical Detection of Streptavidin-Biotin Binding on Nanoporous Anodic Alumina Pore Surface

    by Laura Pol, Josep Ferre-Borrull, Elisabet Xifre-Perez, Josep Pallares, Lluis F. Marsal

    Nanoporous anodic alumina (NAA) is a material with a high interest in nanotechnology[1]. Its physical and chemical properties combined with a cost-effective and scalable production process make it a good candidate in many nanotechnologically-related applications. Its high and tuneable surface-to-volume ratio as well as its interesting optical properties[2] have been used as the basis of different biosensing schemes[3]. Biosensing, and specifically optical biosensing is of great interest in health and environmental applications. The reflection interference spectroscopy (RIfS) method based on NAA has demonstrated its ability in detecting many kinds of molecules (proteins, antibodies[4]). One of the molecular systems with interest in biotechnological applications is the streptavidin-biotin system. The high affinity between both molecules is exploited in many applications for the binding of different biological species. For this reason, we have studied the streptavidin-biotin binding event with NAA-based RIfS, as part of a biosensing process. In our study we assess the optimal conditions for real time monitoring of the different steps (covalent streptavidin bonding, surface passivation, biotin complexation). In order to establish such optimal conditions, we have chosen the protein thrombin as a model molecule to be detected. We prepared NAA with the usual anodization conditions under oxalic acid electrolyte to obtain porous layers with uniform pore diameter and with a thickness that permits the measurement with RIfS in a flow-cell where the different species in solution can be introduced. The experiments consisted of monitoring the change in effective optical thickness (EOT, the quantitative characteristic parameter obtained from RIfS) in the different steps of the biosensing process. The NAA pore surfaces were initially functionalized with (3-aminopropyl)triethoxysilane (APTES) with the carboxyl groups activated in order to form later a peptide bond with the streptavidin. One of the parameters to be optimized was the pore diameter. Furthermore, in order to study the ability of RIfS to detect the covalent streptavidin binding to the NAA pore surface, different concentrations of streptavidin were tested. Finally, the biosensing capabilities were evaluated by detecting biotinylated thrombin at different concentrations. An example of a complete experiment with all the steps in the streptavidin-biotinylated molecule attachment detection can be seen in Figure 1. After establishing a baseline with a PBS flow, streptavidin at 50 µg/ml is introduced in the RIfS setup and its covalent attachment to APTES is detected as an increase in EOT. Following this first step, PBS is introduced to wash away the non-specifically bound molecules and a 3% Bovine Serum Albumin (BSA) solution is flowed to passivate the remaining activated carboxyl groups of APTES and the remaining hydroxyl groups on the NAA pore surface. Such steps are detected by the RIfS procedure. Then, after a subsequent PBS wash, biotinylated thrombin at a concentration of 20 µg/ml is introduced causing a steady increase in EOT reaching a value of 3.5 nm above the initial one. The experiment in Figure 1 was repeated for different NAA pore sizes revealing a higher change in EOT for bigger pore sizes. An important parameter in the detection of the biotinylated molecules binding is the concentration at the streptavidin immobilization step. Thus, different streptavidin concentrations were tested in 60 nm pore diameter NAA. Results are summarized in Figure 2: for the highest concentrations (50 µg/ml) the attachment of streptavidin shows a two-phase curve with an initial phase with a faster increase in EOT and a second phase with a slower increase after an inflection point in the EOT versus time curve. Instead, for a small concentration (1 µg/ml) an initial fast increase is followed by a stabilization of the EOT signal. These two behaviors are associated with the attachment of streptavidin to the activated carboxyl of APTES for the initial fast EOT increase, while the subsequent slower increase can be explained by the aggregation of streptavidin through amine group binding. Finally, in order to demonstrate the capability of quantifying the attachment of biotinylated molecules to the NAA surface, the process was carried out using thrombin as the model molecule and for increasing concentrations. Figure 3 shows the change in EOT as a function of the thrombin concentration. It can be seen that RIfS based on NAA sensing platforms is able to quantify such attachment. [1] Josep Ferré-Borrull, et al., Nanomaterials, vol. 7, p. 5225 (2014). [2] Josep Ferré-Borrull et al., in NANOPOROUS ALUMINA: FABRICATION, STRUCTURE, PROPERTIES AND APPLICATIONS, Springer Series in Materials Science, vol. 219, p. 185 (2015). [3] Chris Eckstein, ACS Applied Materials and Interfaces, vol. 10, p.10571 (2018). [4] Gerard Macías, Analyst, vol. 140, p. 4848 (2015). Figure 1

  • Optical Detection of Thrombin on Nanoporous Anodic Alumina with Aptamer-Modified Surface

    by Laura Pol, Josep Ferré-Borrull, Elisabet Xifré-Pérez, Josep Pallares, Lluis F. Marsal

    Nanoporous anodic alumina (NAA) attracts interest in nanotechnology[1]. Its physical and chemical properties combined with a cost-effective and scalable production make it a good for nanotechnology-related applications. Its high and tuneable surface-to-volume ratio as well as its interesting optical properties[2] have been used as the basis of different biosensing schemes. Biosensing, and specifically optical biosensing is of great interest in health and environmental applications. The reflection interference spectroscopy (RIfS) method based on NAA has demonstrated its ability in detecting many kinds of molecules [3,4]. Biosensors engineered with aptamers as a bioreceptor are called aptabiosensors. Thrombin Binding Aptamer (TBA) has a well-known binding process and high affinity and is one of the most studied aptamers. Thrombin is the key factor of blood coagulation, whose activity is important in wounds and in blood circulation. The free thrombin-binding aptamer remains as a random-coil state in the absence of thrombin, while in the presence of thrombin the protein attaches to the aptamer changing its conformation to quadruplex. In this study we assess the capabilities of NAA with the inner pore surfaces modified with TBA to detect specifically the thrombin protein by means of the RIfS method. We prepared NAA with the usual anodization conditions under oxalic acid electrolyte to obtain porous layers with uniform pore diameter and with a thickness that permits the measurement with RIfS in a flow-cell where the different species in solution can be introduced. The experiments consisted of monitoring the change in effective optical thickness (EOT, the quantitative characteristic parameter obtained from RIfS) in the different steps of the biosensing process. Figure 1 shows SEM pictures of the NAA platforms prepared. The NAA pore surfaces were initially functionalized with (3-aminopropyl)triethoxysilane (APTES) and then the surface mas modified in a three-step procedure monitored in real time thanks to the RIfS method. Figure 2 shows the change in EOT as a function of time during the surface functionalization of NAA: the covalent attachment of Sulfo-NHS-Biotin and subsequent streptavidin attachment (stages 1 and 2 in the figure) and the final immobilization of TBA in the pore walls of NAA (step 3 in the plot).. First, the flow of the Sulfo-NHS-Biotin solution produced a considerable increase in EOT. Then, a further increase in EOT is observed with the infiltration of streptavidin. Finally, EOT also shows clearly the immobilization of biotinylated TBA. The aptamer-functionalized NAA substrates were employed to detect human thrombin protein. For this purpose, different substrates were used in RIfS experiments with human thrombin protein at different concentrations. Figure 3 shows one example of the evolution of the EOT signal upon infiltration of a 1.35 µM thrombin solution. Results show that after obtaining a baseline with constant EOT corresponding to the flow of binding buffer, the thrombin solution is injected causing a rapid increase in EOT, at a rate of 0,05 nm/s. After this increase a stable value is reached after 3600 s, with an absolute change in EOT of ∆EOT = 28 nm. The experiment corresponding to Figure 3 has been repeated for a set of concentrations to obtain a sensitivity curve of the aptamer-functionalized NAA and to determine the lower limit of detection. With this, the dissociation constant of the aptamer-thrombin reaction is determined as Kd = 0,9 µM, the sensitivity to be m = 45.5 nm/µM and the LOD = 72 nM. Finally, in order to demonstrate the specificity of the NAA platform, experiments replacing the flow of thrombin by the flow of a different but similar protein, Bovine Serum Albumin (BSA) were conducted showing a much lower response. Furthermore, thrombin flow experiments with NAA lacking the aptamer functionalization step were also performed to demonstrate the protein does not bind non-specifically to the NAA inner pore walls. [1] Josep Ferré-Borrull, et al., Nanomaterials, vol. 7, p. 5225 (2014). [2] Josep Ferré-Borrull et al., in NANOPOROUS ALUMINA: FABRICATION, STRUCTURE, PROPERTIES AND APPLICATIONS, Springer Series in Materials Science, vol. 219, p. 185 (2015). [3] Laura Pol et al., Nanomaterials, vol. 9, p.478 (2019). [4] Laura Pol et al, Sensors, vol. 19, p. 4543 (2019). Figure 1

  • Open Access

    Aptamer-Based Nanoporous Anodic Alumina Interferometric Biosensor for Real-Time Thrombin Detection

    by Laura Pol, Laura Karen Acosta, Josep Ferré-Borrull, Lluis F. Marsal

    Aptamer biosensors are one of the most powerful techniques in biosensing. Achieving the best platform to use in aptamer biosensors typically includes crucial chemical modifications that enable aptamer immobilization on the surface in the most efficient manner. These chemical modifications must be well defined. In this work we propose nanoporous anodic alumina (NAA) chemically modified with streptavidin as a platform for aptamer immobilization. The immobilization of biotinylated thrombin binding aptamer (TBA) was monitored in real time by means of reflective interferometric spectroscopy (RIfS). The study has permitted to characterize in real time the path to immobilize TBA on the inner pore walls of NAA. Furthermore, this study provides an accurate label-free method to detect thrombin in real-time with high affinity and specificity.


  • Open Access

    Real-Time Monitoring of Biotinylated Molecules Detection Dynamics in Nanoporous Anodic Alumina for Bio-Sensing

    by Laura Pol, Chris Eckstein, Laura K. Acosta, Elisabet Xifré-Pérez, Josep Ferré-Borrull, Lluis F. Marsal

    The chemical modification, or functionalization, of the surfaces of nanomaterials is a key step to achieve biosensors with the best sensitivity and selectivity. The surface modification of biosensors usually comprises several modification steps that have to be optimized. Real-time monitoring of all the reactions taking place during such modification steps can be a highly helpful tool for optimization. In this work, we propose nanoporous anodic alumina (NAA) functionalized with the streptavidin-biotin complex as a platform towards label-free biosensors. Using reflective interferometric spectroscopy (RIfS), the streptavidin-biotin complex formation, using biotinylated thrombin as a molecule model, was monitored in real-time. The study compared the performance of different NAA pore sizes in order to achieve the highest response. Furthermore, the optimal streptavidin concentration that enabled the efficient detection of the biotinylated thrombin attachment was estimated. Finally, the ability of the NAA-RIfS system to quantify the concentration of biotinylated thrombin was evaluated. This study provides an optimized characterization method to monitor the chemical reactions that take place during the biotinylated molecules attachment within the NAA pores.


  • Open Access

    Collagen and fibronectin surface modification of nanoporous anodic alumina and macroporous silicon for endothelial cell cultures

    by P. Formentín, Ú. Catalán, L. Pol, S. Fernández-Castillejo, R. Solà, L. F. Marsal

    The ability to direct the cellular response by means of biomaterial surface topography is important for biomedical applications. Substrate surface topography has been shown to be an effective cue for the regulation of cellular response. Here, the response of human aortic endothelial cells to nanoporous anodic alumina and macroporous silicon with collagen and fibronectin functionalization has been studied. Confocal microscopy and scanning electron microscopy were employed to analyse the effects of the material and the porosity on the adhesion, morphology, and proliferation of the cells. Cell spreading and filopodia formation on macro- and nanoporous material was characterized by atomic force microscopy. We have also studied the influence of the protein on the adhesion. It was obtained the best results when the material is functionalized with fibronectin, regarding cells adhesion, morphology, and proliferation. These results permit to obtain chemical modified 3D structures for several biotechnology applications such as tissue engineering, organ-on-chip or regenerative medicine.


  • Nanoporous Anodic Alumina Surface Modification by Electrostatic, Covalent, and Immune Complexation Binding Investigated by Capillary Filling

    by Chris Eckstein, Laura K. Acosta, Laura Pol, Elisabet Xifré-Pérez, Josep Pallares, Josep Ferré-Borrull, Lluis F. Marsal

    The fluid imbibition-coupled laser interferometry (FICLI) technique has been applied to detect and quantify surface changes and pore dimension variations in nanoporous anodic alumina (NAA) structures. FICLI is a non-invasive optical technique that permits the determination of the NAA average pore radius with high accuracy. In this work, the technique is applied after each step of different surface modification paths of the NAA pores: i) electrostatic immobilization of bovine serum albumin, ii) covalent attachment of streptavidin via (3-aminipropyl)-triethoxysilane and glutaraldehyde grafting and iii) immune complexation. Results show that BSA attachment can be detected as a reduction in estimated radius from FICLI with high accuracy and reproducibility. In the case of the covalent attachment of streptavidin, FICLI is able to recognize a multi-layer formation of the silane and of the protein. For immune complexation, the technique is able to detect different antibody-antigen bindings and to distinguish different dynamics among different immune species.