YanQiang Kong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
YanQiang Kong has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Rui Hou
School of Economics and Management, North China Electric Power University, Beijing, People’s Republic of China
2 shared publications - Xiaoze Du
Key Laboratory of Power Station Energy Transfer Conversion and System, North China Electric Power University, Ministry of Education, Beijing 102206, China
2 shared publications - Bing Cai
State Grid Ningxia Electric Power Co., Ltd, Yinchuan, People’s Republic of China
1 shared publication - Chao Xu
National Key Laboratory of General Artificial Intelligence, School of Intelligence Science and Technology, Peking University, Beijing, China
1 shared publication - Huan Liu
State-owned Assets Supervision and Administration Commission, Ningxia, People’s Republic of China
1 shared publication - Jiangbo Wu
School of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou, China
1 shared publication
Latest Publications
- Open Access
Study on Outlet Temperature Control of External Receiver for Solar Power Tower
Due to the change of direct normal irradiance (DNI) and the change of output power load, the receiver of the solar tower is in an unstable state in the actual operation. In this paper, a 100 MW external cylindric receiver is designed and modelled. The dynamic and comprehensive model is established for the receiver, including the thermal and mechanical equations. The temperature control strategy is applied to the receiver model. The validity of the control strategy is verified by disturbance experiments, including DNI, the inlet temperature of the heat transfer fluid (HTF), and the weather data on a cloudy day. The response characteristics of the receiver are demonstrated. Its thermal lag characteristics and restraining effect on the fluctuating environment are revealed. The dangerous occasion of the receiver during operation are detected, including the overheat of the local panel, and the dissociation point of the molten salt. Both the robustness and the deficiency of the control strategy of the receiver are pointed out. The research results will contribute to the control strategy formulation of the SPT (solar power tower) station.
Open AccessStudy on Outlet Temperature Control of External Receiver for Solar Power Tower
Due to the change of direct normal irradiance (DNI) and the change of output power load, the receiver of the solar tower is in an unstable state in the actual operation. In this paper, a 100 MW external cylindric receiver is designed and modelled. The dynamic and comprehensive model is established for the receiver, including the thermal and mechanical equations. The temperature control strategy is applied to the receiver model. The validity of the control strategy is verified by disturbance experiments, including DNI, the inlet temperature of the heat transfer fluid (HTF), and the weather data on a cloudy day. The response characteristics of the receiver are demonstrated. Its thermal lag characteristics and restraining effect on the fluctuating environment are revealed. The dangerous occasion of the receiver during operation are detected, including the overheat of the local panel, and the dissociation point of the molten salt. Both the robustness and the deficiency of the control strategy of the receiver are pointed out. The research results will contribute to the control strategy formulation of the SPT (solar power tower) station.
- 1 April 2020
- Published by Elsevier in Signal Processing: Image Communication
- Vol. 83
Full-reference IPTV image quality assessment by deeply learning structural cues
- 1 April 2020
- Published by Elsevier in Signal Processing: Image Communication
- Vol. 83
Full-reference IPTV image quality assessment by deeply learning structural cues
- 2 January 2020
- Published by Springer Nature in Neural Computing and Applications
- Vol. 32 (10) , 5399-5407
Unstructured big data analysis algorithm and simulation of Internet of Things based on machine learning
- 2 January 2020
- Published by Springer Nature in Neural Computing and Applications
- Vol. 32 (10) , 5399-5407
Unstructured big data analysis algorithm and simulation of Internet of Things based on machine learning
- Open Access
Influencing Mechanisms of a Crosswind on the Thermo-Hydraulic Characteristics of a Large-Scale Air-Cooled Heat Exchanger
For the large scale air-cooled heat exchanger of a natural draft dry cooling system (NDDCS) in power plants, its thermo-flow characteristics are basically dominated by crosswinds. Unfortunately however, the detailed mechanisms of the crosswind effects have yet to be fully uncovered. Therefore, in this research, the local flow and heat transfer performances of the cooling deltas, which are also termed as the fundamental cells of the large-scale air-cooled heat exchanger, are specifically investigated with full consideration for the cell structure and the water-side temperature distribution at various wind speeds. A 3D CFD method with a realizable k-ε turbulence model, heat exchanger model, and porous media model is developed, and the accuracy and credibility of the numerical model are experimentally validated. With the numerical simulation, the overall 3D outlet air temperature of the large-scale air-cooled heat exchanger, and the corresponding local air velocity and temperature fields of the cooling deltas are qualitatively analyzed. Furthermore, the air-mass flow rate and heat rejection are also quantitatively studied at both the global and local views. The results depict that with an increase in the wind speed, the air mass flow rate and heat rejection will increase greatly for the frontal deltas; however, they will drop dramatically for the middle-front deltas. As for the middle- as well as the middle-rear deltas, the thermo-flow performances vary markedly at various wind speeds, which behave in the most deteriorated manner at a wind speed of 12 m/s. The rear deltas show the best thermo-flow performances at a wind speed of 12 m/s, but the worst at 16 m/s. A detailed analysis of the variable fields for each cooling delta may contribute to the performance improvement of the large-scale air-cooled heat exchanger of NDDCS.
Open AccessInfluencing Mechanisms of a Crosswind on the Thermo-Hydraulic Characteristics of a Large-Scale Air-Cooled Heat Exchanger
For the large scale air-cooled heat exchanger of a natural draft dry cooling system (NDDCS) in power plants, its thermo-flow characteristics are basically dominated by crosswinds. Unfortunately however, the detailed mechanisms of the crosswind effects have yet to be fully uncovered. Therefore, in this research, the local flow and heat transfer performances of the cooling deltas, which are also termed as the fundamental cells of the large-scale air-cooled heat exchanger, are specifically investigated with full consideration for the cell structure and the water-side temperature distribution at various wind speeds. A 3D CFD method with a realizable k-ε turbulence model, heat exchanger model, and porous media model is developed, and the accuracy and credibility of the numerical model are experimentally validated. With the numerical simulation, the overall 3D outlet air temperature of the large-scale air-cooled heat exchanger, and the corresponding local air velocity and temperature fields of the cooling deltas are qualitatively analyzed. Furthermore, the air-mass flow rate and heat rejection are also quantitatively studied at both the global and local views. The results depict that with an increase in the wind speed, the air mass flow rate and heat rejection will increase greatly for the frontal deltas; however, they will drop dramatically for the middle-front deltas. As for the middle- as well as the middle-rear deltas, the thermo-flow performances vary markedly at various wind speeds, which behave in the most deteriorated manner at a wind speed of 12 m/s. The rear deltas show the best thermo-flow performances at a wind speed of 12 m/s, but the worst at 16 m/s. A detailed analysis of the variable fields for each cooling delta may contribute to the performance improvement of the large-scale air-cooled heat exchanger of NDDCS.