SLShaoxiong Liu

Shaoxiong Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shaoxiong Liu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Honghui He

    Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Biopharmaceutical and Health Engineering, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, P. R. China

    5 shared publications
  • Hui Ma

    Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen International Graduate School, Tsinghua University, Shenzhen, China

    5 shared publications
  • Chao He

    Department of Engineering Science, University of Oxford, Oxford, UK

    2 shared publications
  • Conghui Shao

    Tsinghua University, Department of Physics, Beijing, China

    1 shared publication
  • Daniel S. Elson

    Imperial College London

    1 shared publication
  • Ji Qi

    Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, Exhibition Road, London, SW7 2AZ, UK

    1 shared publication

Latest Publications

  • Open Access

    Quantifying Influence of Beam Drift on Linear Retardance Measurement in Dual-Rotating Retarder Mueller Matrix Polarimetry

    by Kaisha Deng, Nan Zeng, Liangyu Deng, Shaoxiong Liu, Hui Ma, Chao He, Honghui He

    Mueller matrix polarimetry is recently attracting more and more attention for its diagnostic potentials. However, for prevalently used division of time Mueller matrix polarimeter based on dual-rotating retarder scheme, beam drift induced by rotating polarizers and waveplates introduces spatial misalignment and pseudo-edge artifacts in imaging results, hindering following accurate microstructural features characterization. In this paper, we quantitatively analyze the beam drift phenomenon in dual-rotating retarder Mueller matrix microscopy and its impact on linear retardance measurement, which is frequently used to reflect tissue fiber arrangement. It is demonstrated that polarizer rotation induces larger beam drift than waveplate rotation due to surface non-uniformity and stress deformation. Furthermore, for waveplates rotated constantly in dual-rotating retarder scheme, their tilt within polarization state analyzer can result in more drift and throughput loss than those within polarization state generator. Finally, phantom and tissue experiments confirm that beam drift, rather than inherent optical path changes, dominates the systematic overestimation of linear retardance in boundary image regions. The findings highlight beam drift as a dominant error source for quantifying linear retardance, necessitating careful optical design alignment and a reliable registration algorithm to obtain highly accurate polarization data for training machine learning models of pathological diagnosis using Mueller matrix microscopy.


  • Open Access

    Analyzing the influence of oblique incidence on quantitative backscattering tissue polarimetry: a pilot ex vivo study

    by Zheng Zhang, Conghui Shao, Honghui He, Chao He, Shaoxiong Liu, Hui Ma

    Polarimetry is attracting increasing attention nowadays, due to its unique ability to obtain microstructural and optical information of tissue samples label-free.1 – 4 Among the available polarimetric techniques, Mueller matrix (MM) imaging can comprehensively characterize the polarization-related properties of media, including diattenuation, retardance, and depolarization, which are of great importance in biomedical studies and clinical trials.5 – 7 Recently, transmission MM microscopy has shown potential in detection of various abnormal and pathological tissues, such as breast cancer,8 cervical cancer,9 colon cancer,10 skin cancer,11,12 liver cirrhosis,13,14 gastrointestinal cancer,15,16 thyroid cancer,17 and lung cancer.18 Meanwhile, the backscattering MM polarimetry provides a promising non-contact and quantitative tool for ex-vivo measurement of bulk tissue samples,6,7,19 – 22 in-vivo imaging of skin tissue,23 – 26 and endoscopic detection of internal organs.27 – 31


  • Deriving Polarimetry Feature Parameters to Characterize Microstructural Features in Histological Sections of Breast Tissues

    by Yang Dong, Jiachen Wan, Lu Si, Yixin Meng, Yanmin Dong, Shaoxiong Liu, Honghui He, Hui Ma

    Objective: Mueller matrix polarimetry technique has been regarded as a powerful tool for probing the microstructural information of tissues. The multiplying of cells and remodeling of collagen fibers in breast carcinoma tissues have been reported to be related to patient survival and prognosis, and they give rise to observable patterns in hematoxylin and eosin (H&E) sections of typical breast tissues (TBTs) that the pathologist can label as three distinctive pathological features (DPFs)-cell nuclei, aligned collagen, and disorganized collagen. The aim of this paper is to propose a pixel based extraction approach of polarimetry feature parameters (PFPs) using a linear discriminant analysis (LDA) classifier. These parameters provide quantitative characterization of the three DPFs in four types of TBTs. Methods: The LDA-based training method learns to find the most simplified linear combination from polarimetry basis parameters (PBPs) constrained under the accuracy remains constant to characterize the specific microstructural feature quantitatively in TBTs. Results: We present results from a cohort of 32 clinical patients with analysis of 224 regions-of-interest. The characterization accuracy for PFPs ranges from 0.82 to 0.91. Conclusion: This work demonstrates the ability of PFPs to quantitatively characterize the DPFs in the H&E pathological sections of TBTs. Significance: This technique paves the way for automatic and quantitative evaluation of specific microstructural features in histopathological digitalization and computer-aided diagnosis.


  • Probing variations of fibrous structures during the development of breast ductal carcinoma tissues via Mueller matrix imaging

    by Yang Dong, Shaoxiong Liu, Yuanxing Shen, Honghui He, Hui Ma

    Recently, we developed a label-free method to probe the microstructural information and optical properties of unstained thin tissue slices based on microscopic Mueller matrix imaging technique. In this paper, we take the microscopic Mueller matrix images of human breast ductal carcinoma tissue samples at different pathological stages, and then calculate and analyze their retardance-related Mueller matrix-derived parameters. To reveal the microstructural features more quantitatively and precisely, we propose a new method based on first-order statistical properties of image to transform the 2D images of Mueller matrix parameters into several statistical feature vectors. We evaluate each statistical feature vector by corresponding classification characteristic value extracted from the statistical features of Mueller matrix parameters images of healthy breast duct tissue samples. The experimental results indicate that these statistical feature vectors of Mueller matrix derived parameters may become powerful tools to quantitatively characterize breast ductal carcinoma tissue samples at different pathological stages. It has the potential to facilitate automating the staging process of breast ductal carcinoma tissue, resulting in the improvement of diagnostic efficiency.


  • Open Access

    Quantitative Analysis of 4 × 4 Mueller Matrix Transformation Parameters for Biomedical Imaging

    by Wei Sheng, Weipeng Li, Ji Qi, Teng Liu, Honghui He, Yang Dong, Shaoxiong Liu, Jian Wu, Daniel S. Elson, Hui Ma

    Mueller matrix polarimetry is a potentially powerful technique for obtaining microstructural information of biomedical specimens. Thus, it has found increasing application in both backscattering imaging of bulk tissue samples and transmission microscopic imaging of thin tissue slices. Recently, we proposed a technique to transform the 4 × 4 Mueller matrix elements into a group of parameters, which have explicit associations with specific microstructural features of samples. In this paper, we thoroughly analyze the relationships between the Mueller matrix transformation parameters and the characteristic microstructures of tissues by using experimental phantoms and Monte Carlo simulations based on different tissue mimicking models. We also adopt quantitative evaluation indicators to compare the Mueller matrix transformation parameters with the Mueller matrix polar decomposition parameters. The preliminary imaging results of bulk porcine colon tissues and thin human pathological tissue slices demonstrate the potential of Mueller matrix transformation parameters as biomedical diagnostic indicators. Also, this study provides quantitative criteria for parameter selection in biomedical Mueller matrix imaging.