Kristen O'HAlloran Cardinal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kristen O'HAlloran Cardinal has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Alyssa McCulloch
Department of Biomedical Engineering (I.S., H.O., A.M, K.O.C.), Cal Poly, San Luis Obispo, CA, USA. Stryker Neurovascular (S.F., R.G.), Fremont, CA, USA. Community Neurosciences Institute (H.C.), Fresno, CA, USA
3 shared publicationsAshley Turcott
Biomedical Engineering Department, Cal Poly, San Luis Obispo, California, USA
2 shared publicationsBrandon Puccini
Mechanical Engineering Department, Cal Poly, 1 Grand Ave, San Luis Obispo, CA, 93407, USA
2 shared publicationsKristen Temnyk
Biomedical Engineering Department, Cal Poly, 1 Grand Ave, San Luis Obispo, CA, 93407, USA
2 shared publicationsScott Herting
Biomedical Engineering Department, Cal Poly, 1 Grand Ave, San Luis Obispo, CA, 93407, USA
2 shared publicationsSergey Frenklakh
Stryker Neurovascular Intervention, Research and Development, Fremont, USA
2 shared publications
Latest Publications
- 25 November 2025
- Published by SAGE Publications in Interventional Neuroradiology
A novel in vitro dye-based flow visualization method for quantifying the neointimal healing response of aneurysm devices in endothelialized silicone models
Purpose: To develop and implement a novel tool for evaluating neointimal healing over flow diverting aneurysm devices in vitro using a biocompatible, dye-based flow visualization method. Methods: Biocompatibility of Brilliant Blue FCF (BB FCF) dye was established using an alamarBlue metabolic viability assay. Next, a custom MATLAB image analysis script to quantify three intra-aneurysmal dye transport parameters (fill time, washout time, and max intensity) was evaluated through benchtop testing. Video recordings of BB FCF injections in four silicone aneurysm models with increasing levels of device-facilitated occlusion (0–100%) were used to quantify corresponding changes in dye transport parameters. Finally, the method was applied in a 14-day endothelialized silicone blood vessel mimic (BVM) study to assess the impact of repeated BB FCF injections on vessel construct morphology. Results: BB FCF was noncytotoxic at concentrations ≤500 µM. Dye transport parameters differed as expected between occlusion models; fill and washout times were prolonged in partially occluded models compared to the patent control ( p < .01), and maximum dye intensity decreased across all models as a function of occlusion ( p < .0001). Repeated BB FCF injections in BVMs showed no morphological differences between endothelial linings in injection-treated vessels vs. no-injection controls. Conclusion: The methods and results documented in this study demonstrate that a non-angiographic dye-based flow visualization method has potential to provide a repeatable, non-destructive way to assess gradual healing-mediated occlusion performance of flow diverter devices in vitro , complementing traditional imaging techniques. This method lays the groundwork for correlating flow-based transport metrics with endothelial coverage to better understand healing-based aneurysm occlusion.
- 25 November 2025
- Published by SAGE Publications in Interventional Neuroradiology
A novel in vitro dye-based flow visualization method for quantifying the neointimal healing response of aneurysm devices in endothelialized silicone models
Purpose: To develop and implement a novel tool for evaluating neointimal healing over flow diverting aneurysm devices in vitro using a biocompatible, dye-based flow visualization method. Methods: Biocompatibility of Brilliant Blue FCF (BB FCF) dye was established using an alamarBlue metabolic viability assay. Next, a custom MATLAB image analysis script to quantify three intra-aneurysmal dye transport parameters (fill time, washout time, and max intensity) was evaluated through benchtop testing. Video recordings of BB FCF injections in four silicone aneurysm models with increasing levels of device-facilitated occlusion (0–100%) were used to quantify corresponding changes in dye transport parameters. Finally, the method was applied in a 14-day endothelialized silicone blood vessel mimic (BVM) study to assess the impact of repeated BB FCF injections on vessel construct morphology. Results: BB FCF was noncytotoxic at concentrations ≤500 µM. Dye transport parameters differed as expected between occlusion models; fill and washout times were prolonged in partially occluded models compared to the patent control ( p < .01), and maximum dye intensity decreased across all models as a function of occlusion ( p < .0001). Repeated BB FCF injections in BVMs showed no morphological differences between endothelial linings in injection-treated vessels vs. no-injection controls. Conclusion: The methods and results documented in this study demonstrate that a non-angiographic dye-based flow visualization method has potential to provide a repeatable, non-destructive way to assess gradual healing-mediated occlusion performance of flow diverter devices in vitro , complementing traditional imaging techniques. This method lays the groundwork for correlating flow-based transport metrics with endothelial coverage to better understand healing-based aneurysm occlusion.
- 11 September 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (3) , 517-522
In Vitro Assessment of Vascular Injury following Stent Retriever Retraction in Clinically Relevant Endothelialized Silicone Models
Mechanical thrombectomy devices have potential to injure the vessel during treatment of acute ischemic stroke. The goal of the current work was to tailor in vitro endothelialized silicone models for stent retriever assessment and to evaluate endothelial injury following treatment by various stent retriever designs and sizes. Clinically-relevant neurovascular geometries were first modeled out of silicone, then sterilized, coated with fibronectin, placed in bioreactors, seeded with human endothelial cells, and cultivated under flow. Several sizes of two different commercially available stent retrievers were then deployed in, and retracted through, vessels. Vessels were immediately harvested and stained. Endothelial injury, identified as denudation, was quantified using ImageJ. Results illustrated that endothelial injury ranged from 16-18% in wire/microcatheter-only treated vessels, 37-61% in 1-pass treatments, and 52-70% in 2-pass treatments. Overall this work showcases an in vitro approach for early stage assessment of the extent and location of vascular injury following stent retriever retraction.
- 11 September 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (3) , 517-522
In Vitro Assessment of Vascular Injury following Stent Retriever Retraction in Clinically Relevant Endothelialized Silicone Models
Mechanical thrombectomy devices have potential to injure the vessel during treatment of acute ischemic stroke. The goal of the current work was to tailor in vitro endothelialized silicone models for stent retriever assessment and to evaluate endothelial injury following treatment by various stent retriever designs and sizes. Clinically-relevant neurovascular geometries were first modeled out of silicone, then sterilized, coated with fibronectin, placed in bioreactors, seeded with human endothelial cells, and cultivated under flow. Several sizes of two different commercially available stent retrievers were then deployed in, and retracted through, vessels. Vessels were immediately harvested and stained. Endothelial injury, identified as denudation, was quantified using ImageJ. Results illustrated that endothelial injury ranged from 16-18% in wire/microcatheter-only treated vessels, 37-61% in 1-pass treatments, and 52-70% in 2-pass treatments. Overall this work showcases an in vitro approach for early stage assessment of the extent and location of vascular injury following stent retriever retraction.
- 17 July 2023
- Published by Springer Nature in Neuroradiology
- Vol. 65 (10) , 1507-1515
Evaluation of vessel injury after simulated catheter use in an endothelialized silicone model of the intracranial arteries
Purpose Neurothrombectomy catheters can disrupt or injure the vessel wall. This potential injury is often studied in animal or cadaver models, but prior work suggests that endothelialized silicone models may be an option for early in vitro assessment. The purpose of this work was to create a complex, clinically-relevant endothelialized neurovascular silicone model, and to determine the utility of the model for evaluating vessel injury due to catheter simulated use. Methods Models of the ICA and MCA were fabricated out of silicone, sterilized, coated with fibronectin, placed in bioreactors, and endothelialized with HUVECs. These silicone vessels were maintained under flow for 3 and 7 days, and cellular linings were assessed. Subsequently, 24 silicone vessels were created and treated with neurovascular catheters. Vessels were accessed with a guidewire, microcatheter, and/or aspiration catheter, either once (1-pass) or three times (3-pass). Vessels were then fixed, and injury was evaluated through quantitative image analysis and a visual scoring system. Results Complex silicone models were successfully endothelialized and maintained with consistent cell linings. The transparent silicone permitted catheter simulated use without fluoroscopy, and injury to the vessel wall was observed and successfully imaged and characterized. Vessels subjected to 3-passes exhibited more injury than 1-pass, and injury increased with the number and size of devices. These results illustrated expected trends and support use of these models for early assessment of vessel injury. Conclusion Complex silicone neurovascular models can be endothelialized and used in vitro to assess and compare injury due to the use of neurovascular catheters.
- 17 July 2023
- Published by Springer Nature in Neuroradiology
- Vol. 65 (10) , 1507-1515
Evaluation of vessel injury after simulated catheter use in an endothelialized silicone model of the intracranial arteries
Purpose Neurothrombectomy catheters can disrupt or injure the vessel wall. This potential injury is often studied in animal or cadaver models, but prior work suggests that endothelialized silicone models may be an option for early in vitro assessment. The purpose of this work was to create a complex, clinically-relevant endothelialized neurovascular silicone model, and to determine the utility of the model for evaluating vessel injury due to catheter simulated use. Methods Models of the ICA and MCA were fabricated out of silicone, sterilized, coated with fibronectin, placed in bioreactors, and endothelialized with HUVECs. These silicone vessels were maintained under flow for 3 and 7 days, and cellular linings were assessed. Subsequently, 24 silicone vessels were created and treated with neurovascular catheters. Vessels were accessed with a guidewire, microcatheter, and/or aspiration catheter, either once (1-pass) or three times (3-pass). Vessels were then fixed, and injury was evaluated through quantitative image analysis and a visual scoring system. Results Complex silicone models were successfully endothelialized and maintained with consistent cell linings. The transparent silicone permitted catheter simulated use without fluoroscopy, and injury to the vessel wall was observed and successfully imaged and characterized. Vessels subjected to 3-passes exhibited more injury than 1-pass, and injury increased with the number and size of devices. These results illustrated expected trends and support use of these models for early assessment of vessel injury. Conclusion Complex silicone neurovascular models can be endothelialized and used in vitro to assess and compare injury due to the use of neurovascular catheters.
- Open Access
- 1 December 2020
- Published by SAGE Publications in Tissue Engineering Part C: Methods
- Vol. 26 (12) , 628-636
SIMPoly: A Matlab-Based Image Analysis Tool to Measure Electrospun Polymer Scaffold Fiber Diameter
Quantifying fiber diameter is important for characterizing electrospun polymer scaffolds. Many researchers use manual measurement methods, which can be time-consuming and variable. Semi-automated tools exist, but there is room for improvement. The current work used Matlab to develop an image analysis program to quickly and consistently measure fiber diameter in scanning electron micrographs. The new Matlab method, termed “SIMPoly” (Semiautomated Image Measurements of Polymers) was validated by using synthetic images with known fiber size and was found to be accurate. The Matlab method was also applied by three different researchers to scanning electron microscopy (SEM) images of electrospun poly(lactic-co-glycolic acid) (PLGA). Results were compared with the semi-automated DiameterJ method and a manual ImageJ measurement approach, and it was found that the Matlab-based SIMPoly method provided measurements in the expected range and with the least variability between researchers. In conclusion, this work provides and describes SIMPoly, a Matlab-based image analysis method that can simply and accurately measure polymer fiber diameters in SEM images with minimal variation between users.
- 1 December 2020
- Published by SAGE Publications in Tissue Engineering Part C: Methods
- Vol. 26 (12) , 628-636
Open AccessSIMPoly: A Matlab-Based Image Analysis Tool to Measure Electrospun Polymer Scaffold Fiber Diameter
Quantifying fiber diameter is important for characterizing electrospun polymer scaffolds. Many researchers use manual measurement methods, which can be time-consuming and variable. Semi-automated tools exist, but there is room for improvement. The current work used Matlab to develop an image analysis program to quickly and consistently measure fiber diameter in scanning electron micrographs. The new Matlab method, termed “SIMPoly” (Semiautomated Image Measurements of Polymers) was validated by using synthetic images with known fiber size and was found to be accurate. The Matlab method was also applied by three different researchers to scanning electron microscopy (SEM) images of electrospun poly(lactic-co-glycolic acid) (PLGA). Results were compared with the semi-automated DiameterJ method and a manual ImageJ measurement approach, and it was found that the Matlab-based SIMPoly method provided measurements in the expected range and with the least variability between researchers. In conclusion, this work provides and describes SIMPoly, a Matlab-based image analysis method that can simply and accurately measure polymer fiber diameters in SEM images with minimal variation between users.
- Open Access
- 26 October 2020
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 13 (8) , 727-731
Endothelialized silicone aneurysm models for in vitro evaluation of flow diverters
Objective The goal of this work was to endothelialize silicone aneurysm tubes for use as in vitro models for evaluating endothelial cell interactions with neurovascular devices. The first objective was to establish consistent and confluent endothelial cell linings and to evaluate the silicone vessels over time. The second objective was to use these silicone vessels for flow diverter implantation and assessment. Methods Silicone aneurysm tubes were coated with fibronectin and placed into individual bioreactor systems. Human umbilical vein endothelial cells were deposited within tubes to create silicone vessels, then cultivated on a peristaltic pump and harvested at 2, 5, 7, or 10 days to evaluate the endothelial cell lining. A subset of silicone aneurysm vessels was used for flow diverter implantation, and evaluated for cell coverage over device struts at 3 or 7 days after deployment. Results Silicone vessels maintained confluent, PECAM-1 (platelet endothelial cell adhesion molecule 1) positive endothelial cell linings over time. These vessels facilitated and withstood flow diverter implantation, with robust cell linings disclosed after device deployment. Additionally, the endothelial cells responded to implanted devices through coverage of the flow diverter struts with increased cell coverage over the aneurysm seen at 7 days after deployment as compared with 3 days. Conclusions Silicone aneurysm models can be endothelialized and successfully maintained in vitro over time. Furthermore, these silicone vessels can be used for flow diverter implantation and assessment.
- 26 October 2020
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 13 (8) , 727-731
Open AccessEndothelialized silicone aneurysm models for in vitro evaluation of flow diverters
Objective The goal of this work was to endothelialize silicone aneurysm tubes for use as in vitro models for evaluating endothelial cell interactions with neurovascular devices. The first objective was to establish consistent and confluent endothelial cell linings and to evaluate the silicone vessels over time. The second objective was to use these silicone vessels for flow diverter implantation and assessment. Methods Silicone aneurysm tubes were coated with fibronectin and placed into individual bioreactor systems. Human umbilical vein endothelial cells were deposited within tubes to create silicone vessels, then cultivated on a peristaltic pump and harvested at 2, 5, 7, or 10 days to evaluate the endothelial cell lining. A subset of silicone aneurysm vessels was used for flow diverter implantation, and evaluated for cell coverage over device struts at 3 or 7 days after deployment. Results Silicone vessels maintained confluent, PECAM-1 (platelet endothelial cell adhesion molecule 1) positive endothelial cell linings over time. These vessels facilitated and withstood flow diverter implantation, with robust cell linings disclosed after device deployment. Additionally, the endothelial cells responded to implanted devices through coverage of the flow diverter struts with increased cell coverage over the aneurysm seen at 7 days after deployment as compared with 3 days. Conclusions Silicone aneurysm models can be endothelialized and successfully maintained in vitro over time. Furthermore, these silicone vessels can be used for flow diverter implantation and assessment.
- Open Access
- 14 March 2020
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 31 (3) , 1-12
Custom tissue engineered aneurysm models with varying neck size and height for early stage in vitro testing of flow diverters
Endovascular techniques for treating cerebral aneurysms are rapidly advancing and require testing to optimize device configurations. The purpose of this work was to customize tissue-engineered aneurysm “blood vessel mimics” (aBVMs) for early stage in vitro assessment of vascular cell responses to flow diverters and other devices. Aneurysm scaffolds with varying neck size and height were created through solid modeling, mold fabrication, mandrel creation, and electrospinning. Scaffold dimensions and fiber morphology were characterized. aBVMs were created by depositing human smooth muscle and endothelial cells within scaffolds, and cultivating within perfusion bioreactors. These vessels were left untreated or used for flow diverter implantation. Cellular responses to flow diverters were evaluated at 3 days. Custom scaffolds were created with aneurysm neck diameters of 2.3, 3.5, and 5.5 mm and with aneurysm heights of 2, 5, and 8 mm. A set of scaffolds with varying neck size was used for aBVM creation, and dual-sodding of endothelial and smooth muscle cells resulted in consistent and confluent cellular linings. Flow diverters were successfully implanted in a subset of aBVMs, and initial cell coverage over devices was seen in the parent vessel at 3 days. Direct visualization of the device over the neck region was feasible, supporting the future use of these models for evaluating and comparing flow diverter healing. Tissue-engineered aneurysm models can be created with custom neck sizes and heights, and used to evaluate cellular responses to flow diverters and other endovascular devices.
- 14 March 2020
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 31 (3) , 1-12
Open AccessCustom tissue engineered aneurysm models with varying neck size and height for early stage in vitro testing of flow diverters
Endovascular techniques for treating cerebral aneurysms are rapidly advancing and require testing to optimize device configurations. The purpose of this work was to customize tissue-engineered aneurysm “blood vessel mimics” (aBVMs) for early stage in vitro assessment of vascular cell responses to flow diverters and other devices. Aneurysm scaffolds with varying neck size and height were created through solid modeling, mold fabrication, mandrel creation, and electrospinning. Scaffold dimensions and fiber morphology were characterized. aBVMs were created by depositing human smooth muscle and endothelial cells within scaffolds, and cultivating within perfusion bioreactors. These vessels were left untreated or used for flow diverter implantation. Cellular responses to flow diverters were evaluated at 3 days. Custom scaffolds were created with aneurysm neck diameters of 2.3, 3.5, and 5.5 mm and with aneurysm heights of 2, 5, and 8 mm. A set of scaffolds with varying neck size was used for aBVM creation, and dual-sodding of endothelial and smooth muscle cells resulted in consistent and confluent cellular linings. Flow diverters were successfully implanted in a subset of aBVMs, and initial cell coverage over devices was seen in the parent vessel at 3 days. Direct visualization of the device over the neck region was feasible, supporting the future use of these models for evaluating and comparing flow diverter healing. Tissue-engineered aneurysm models can be created with custom neck sizes and heights, and used to evaluate cellular responses to flow diverters and other endovascular devices.
- Open Access
- 26 June 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (6) , e0217709
Tissue-engineered blood vessel mimics in complex geometries for intravascular device testing
Intravascular stents are commonly used to treat occluded arteries during coronary heart disease. After coronary stent implantation, endothelial cells grow over the stent, which is referred to as re-endothelialization. Re-endothelialization prevents blood from clotting on the stent surface and is a good predictor of stent success. Blood vessel mimics (BVMs) are in vitro tissue-engineered models of human blood vessels that may be used to preclinically test stents for re-endothelialization. BVMs have been developed in straight geometries. However, the United States Food and Drug Administration recommends that devices intended to treat coronary occlusions be preclinically tested in bent and bifurcated vessels due to the complex geometries of native coronary arteries. The main objectives of this study were to develop and characterize BVMs in complex geometries. Bioreactors were designed and constructed so that BVMs could be cultivated in bent (>45°) and bifurcated geometries. Human umbilical vein endothelial cells were sodded onto complex-shaped scaffolds, and the resulting BVMs were characterized for cell deposition. For a final proof of concept, a coronary stent was deployed in a severely angulated BVM. The new bioreactors were easy to use and mounting scaffolds in complex geometries in the bioreactors was successful. After sodding scaffolds with cells, there were no statistically significant differences between the cell densities along the length of the BVMs, on the top and bottom halves of the BVMs, or on the inner and outer halves of the BVMs. This suggests cells deposited evenly throughout the scaffolds, resulting in consistent complex-geometry BVMs. Also, a coronary stent was successfully deployed in a severely angulated BVM. Bioreactors can be constructed for housing complex-shaped vessels. BVMs can be developed in the complex geometries observed in native coronary arteries with endothelial cells evenly dispersed throughout BVM lumens.
- 26 June 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (6) , e0217709
Open AccessTissue-engineered blood vessel mimics in complex geometries for intravascular device testing
Intravascular stents are commonly used to treat occluded arteries during coronary heart disease. After coronary stent implantation, endothelial cells grow over the stent, which is referred to as re-endothelialization. Re-endothelialization prevents blood from clotting on the stent surface and is a good predictor of stent success. Blood vessel mimics (BVMs) are in vitro tissue-engineered models of human blood vessels that may be used to preclinically test stents for re-endothelialization. BVMs have been developed in straight geometries. However, the United States Food and Drug Administration recommends that devices intended to treat coronary occlusions be preclinically tested in bent and bifurcated vessels due to the complex geometries of native coronary arteries. The main objectives of this study were to develop and characterize BVMs in complex geometries. Bioreactors were designed and constructed so that BVMs could be cultivated in bent (>45°) and bifurcated geometries. Human umbilical vein endothelial cells were sodded onto complex-shaped scaffolds, and the resulting BVMs were characterized for cell deposition. For a final proof of concept, a coronary stent was deployed in a severely angulated BVM. The new bioreactors were easy to use and mounting scaffolds in complex geometries in the bioreactors was successful. After sodding scaffolds with cells, there were no statistically significant differences between the cell densities along the length of the BVMs, on the top and bottom halves of the BVMs, or on the inner and outer halves of the BVMs. This suggests cells deposited evenly throughout the scaffolds, resulting in consistent complex-geometry BVMs. Also, a coronary stent was successfully deployed in a severely angulated BVM. Bioreactors can be constructed for housing complex-shaped vessels. BVMs can be developed in the complex geometries observed in native coronary arteries with endothelial cells evenly dispersed throughout BVM lumens.
- 27 March 2019
- Published by Springer Nature in Neuroradiology
- Vol. 61 (6) , 723-732
Tissue-engineered aneurysm models for in vitro assessment of neurovascular devices
Preclinical testing of neurovascular devices is crucial for successful device design and is commonly performed using in vivo organisms such as the rabbit elastase-induced aneurysm model; however, simple in vitro models may help further refine this testing paradigm. The purpose of the current work was to evaluate, and further develop, tissue-engineered blood vessel mimics (BVMs) as simple, early-stage models to assess neurovascular devices in vitro prior to animal or clinical use.
- 27 March 2019
- Published by Springer Nature in Neuroradiology
- Vol. 61 (6) , 723-732
Tissue-engineered aneurysm models for in vitro assessment of neurovascular devices
Preclinical testing of neurovascular devices is crucial for successful device design and is commonly performed using in vivo organisms such as the rabbit elastase-induced aneurysm model; however, simple in vitro models may help further refine this testing paradigm. The purpose of the current work was to evaluate, and further develop, tissue-engineered blood vessel mimics (BVMs) as simple, early-stage models to assess neurovascular devices in vitro prior to animal or clinical use.
- 1 September 2016
- Published by SAGE Publications in Applied In Vitro Toxicology
- Vol. 2 (3) , 175-182
Human Umbilical Versus Coronary Cell Sources for Tissue-Engineered Blood Vessel Mimics
Along with the advancement of tissue engineering methods to produce implantable constructs has come the development of methods to create tissue-engineered constructs for in vitro preclinical testing of drugs, devices, and other therapeutics. Blood vessel mimics (BVMs) are examples of tissue-engineered in vitro models that have been created for the assessment of endothelial cell responses to implanted devices and intravascular imaging modalities. These BVMs could also serve as preclinical models for early-stage pharmaceutical screening. The current work aimed to build on previous BVM capabilities in three ways: by establishing and documenting a method to create dual-layer BVMs with smooth muscle and endothelial cells, by utilizing and comparing human umbilical and human coronary sources of cells, and by evaluating the ability of BVMs created with the new methods to withstand device implantation. In both umbilical and coronary BVMs, histology and scanning electron microscopy (SEM) confirmed the presence of a confluent cell layer within the lumen of the scaffold. After device deployment, SEM revealed that the cellular lining remained intact, and in umbilical vessels, some evidence of an early endothelial response was observed. The data presented here support the use of the documented methods to create dual-layer BVMs from a variety of cell sources.
- 1 September 2016
- Published by SAGE Publications in Applied In Vitro Toxicology
- Vol. 2 (3) , 175-182
Human Umbilical Versus Coronary Cell Sources for Tissue-Engineered Blood Vessel Mimics
Along with the advancement of tissue engineering methods to produce implantable constructs has come the development of methods to create tissue-engineered constructs for in vitro preclinical testing of drugs, devices, and other therapeutics. Blood vessel mimics (BVMs) are examples of tissue-engineered in vitro models that have been created for the assessment of endothelial cell responses to implanted devices and intravascular imaging modalities. These BVMs could also serve as preclinical models for early-stage pharmaceutical screening. The current work aimed to build on previous BVM capabilities in three ways: by establishing and documenting a method to create dual-layer BVMs with smooth muscle and endothelial cells, by utilizing and comparing human umbilical and human coronary sources of cells, and by evaluating the ability of BVMs created with the new methods to withstand device implantation. In both umbilical and coronary BVMs, histology and scanning electron microscopy (SEM) confirmed the presence of a confluent cell layer within the lumen of the scaffold. After device deployment, SEM revealed that the cellular lining remained intact, and in umbilical vessels, some evidence of an early endothelial response was observed. The data presented here support the use of the documented methods to create dual-layer BVMs from a variety of cell sources.
- 1 February 2013
- Published by SAGE Publications in Tissue Engineering Part B: Reviews
- Vol. 19 (1) , 14-30
Thinking Inside the Box: Keeping Tissue-Engineered Constructs In Vitro for Use as Preclinical Models
Tissue engineers have made great strides toward the creation of living tissue replacements for a wide range of tissue types and applications, with eventual patient implantation as the primary goal. However, an alternate use of tissue-engineered constructs exists: as in vitro preclinical models for purposes such as drug screening and device testing. Tissue-engineered preclinical models have numerous potential advantages over existing models, including cultivation in three-dimensional geometries, decreased cost, increased reproducibility, precise control over cultivation conditions, and the incorporation of human cells. Over the past decade, a number of researchers have developed and used tissue-engineered constructs as preclinical models for testing pharmaceuticals, gene therapies, stents, and other technologies, with examples including blood vessels, skeletal muscle, bone, cartilage, skin, cardiac muscle, liver, cornea, reproductive tissues, adipose, small intestine, neural tissue, and kidney. The focus of this article is to review accomplishments toward the creation and use of tissue-engineered preclinical models of each of these different tissue types.
- 1 February 2013
- Published by SAGE Publications in Tissue Engineering Part B: Reviews
- Vol. 19 (1) , 14-30
Thinking Inside the Box: Keeping Tissue-Engineered Constructs In Vitro for Use as Preclinical Models
Tissue engineers have made great strides toward the creation of living tissue replacements for a wide range of tissue types and applications, with eventual patient implantation as the primary goal. However, an alternate use of tissue-engineered constructs exists: as in vitro preclinical models for purposes such as drug screening and device testing. Tissue-engineered preclinical models have numerous potential advantages over existing models, including cultivation in three-dimensional geometries, decreased cost, increased reproducibility, precise control over cultivation conditions, and the incorporation of human cells. Over the past decade, a number of researchers have developed and used tissue-engineered constructs as preclinical models for testing pharmaceuticals, gene therapies, stents, and other technologies, with examples including blood vessels, skeletal muscle, bone, cartilage, skin, cardiac muscle, liver, cornea, reproductive tissues, adipose, small intestine, neural tissue, and kidney. The focus of this article is to review accomplishments toward the creation and use of tissue-engineered preclinical models of each of these different tissue types.