Bingxing Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bingxing Wu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Suat Utku Ay
Worcester Polytechnic Institute
3 shared publications - Ahmed Abdel-Rahim
Department of Civil and Environmental Engineering, College of Engineering, University of Idaho, Moscow, ID 83844, USA
1 shared publication - Mohamed R. Elmezayen
Department of Electrical and Computer Engineering University of Idaho Moscow Idaho USA
1 shared publication - Soumya Keshavamurthy Srivastava
Department of Chemical and Biomedical Engineering, West Virginia University, Morgantown, WV 26506, USA
1 shared publication - Wei Hu
Thermo Fisher Scientific, Jinke Road 2537, Pudong District, Shanghai 201206, China
1 shared publication
Latest Publications
- Open Access
- 30 September 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1654
Comparative Study and Simulation of Capacitive Sensors in Microfluidic Channels for Sensitive Red Blood Cell Detection
Microfluidics provides an indispensable platform for combining analytical operations such as sample preparation, mixing, separation/enrichment, and detection onto a single compact platform, defined as a lab-on-a-chip (LOC) device with applicability in biomedical and life science applications. Due to its ease of integration, 1D interdigital capacitive (IDC) sensors have been used in microfluidic platforms to detect particles of interest. This paper presents a comparative study on the use of capacitive sensors for microfluidic devices to detect bioparticles, more specifically red blood cells (RBCs). The detection sensitivities of 1D, 2D, and 3D capacitive sensors were determined by simulation using COMSOL Multiphysics® v5.5. A water-filled 25 μm × 25 μm PDMS microfluidic channel was used with different sizes (5–10 μm) of red blood cells passing across the capacitive sensor regions. The conformal mapping was used for translating the 1D IDC sensor dimensions into equivalent 2D/3D parallel plate capacitance (PPC) sensor dimensions, creating similar absolute sensor capacitance. The detection sensitivity of each capacitive sensor is determined, and a new 3D PPC sensor structure was proposed to improve the sensitivity for high-resolution RBC detection in microfluidic channels. Proposed 2D and 3D sensors provide a 3× to 20× improvement in sensitivity compared to the standard 1D IDC structures, achieving a 100 aF capacitance difference when a healthy RBC passes in the structure.
- 30 September 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1654
Open AccessComparative Study and Simulation of Capacitive Sensors in Microfluidic Channels for Sensitive Red Blood Cell Detection
Microfluidics provides an indispensable platform for combining analytical operations such as sample preparation, mixing, separation/enrichment, and detection onto a single compact platform, defined as a lab-on-a-chip (LOC) device with applicability in biomedical and life science applications. Due to its ease of integration, 1D interdigital capacitive (IDC) sensors have been used in microfluidic platforms to detect particles of interest. This paper presents a comparative study on the use of capacitive sensors for microfluidic devices to detect bioparticles, more specifically red blood cells (RBCs). The detection sensitivities of 1D, 2D, and 3D capacitive sensors were determined by simulation using COMSOL Multiphysics® v5.5. A water-filled 25 μm × 25 μm PDMS microfluidic channel was used with different sizes (5–10 μm) of red blood cells passing across the capacitive sensor regions. The conformal mapping was used for translating the 1D IDC sensor dimensions into equivalent 2D/3D parallel plate capacitance (PPC) sensor dimensions, creating similar absolute sensor capacitance. The detection sensitivity of each capacitive sensor is determined, and a new 3D PPC sensor structure was proposed to improve the sensitivity for high-resolution RBC detection in microfluidic channels. Proposed 2D and 3D sensors provide a 3× to 20× improvement in sensitivity compared to the standard 1D IDC structures, achieving a 100 aF capacitance difference when a healthy RBC passes in the structure.
- 17 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 67 (12) , 4484-4493
Single-Slope Look-Ahead Ramp ADC for CMOS Image Sensors
Integrating type analog-to-digital converters (ADC) used in column-parallel CMOS image sensors trade conversion speed with size, power, and complexity to achieve optimal performance. A new integrating ADC architecture called single-slope look-ahead ramp (SSLAR) ADC is introduced in this paper. It utilizes a statistical approach and code-prediction methods to improve the conversion speed of standard single-slope ramp (SSR) ADC. It is shown that SSLAR ADC reduces power consumption while achieving an increased frame rate. This is achieved by the SSLAR algorithm that was optimized for column-parallel CMOS active pixel sensor (APS) imager architecture. A 10-bit SSLAR ADC was designed in a 0.5μm CMOS (2P3M) process and integrated with a column-parallel CMOS image sensor that has 200x 150 array with 15μm pixels. Measurements showed that a 6x frame rate increase can be achieved while reducing power consumption 13% with minimal impact on image quality.
- 17 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 67 (12) , 4484-4493
Single-Slope Look-Ahead Ramp ADC for CMOS Image Sensors
Integrating type analog-to-digital converters (ADC) used in column-parallel CMOS image sensors trade conversion speed with size, power, and complexity to achieve optimal performance. A new integrating ADC architecture called single-slope look-ahead ramp (SSLAR) ADC is introduced in this paper. It utilizes a statistical approach and code-prediction methods to improve the conversion speed of standard single-slope ramp (SSR) ADC. It is shown that SSLAR ADC reduces power consumption while achieving an increased frame rate. This is achieved by the SSLAR algorithm that was optimized for column-parallel CMOS active pixel sensor (APS) imager architecture. A 10-bit SSLAR ADC was designed in a 0.5μm CMOS (2P3M) process and integrated with a column-parallel CMOS image sensor that has 200x 150 array with 15μm pixels. Measurements showed that a 6x frame rate increase can be achieved while reducing power consumption 13% with minimal impact on image quality.
- 27 March 2019
- Published by Springer Nature in International Journal of Automation and Computing
- Vol. 16 (4) , 449-461
Pedestrian Height Estimation and 3D Reconstruction Using Pixel-resolution Mapping Method Without Special Patterns
- 27 March 2019
- Published by Springer Nature in International Journal of Automation and Computing
- Vol. 16 (4) , 449-461
Pedestrian Height Estimation and 3D Reconstruction Using Pixel-resolution Mapping Method Without Special Patterns