Timm Dickfeld
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Timm Dickfeld has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Hugh Calkins
4 shared publicationsHenry Halperin
3 shared publicationsStephen B. Solomon
3 shared publicationsAlbert C. Lardo
2 shared publicationsGlenn Meininger
Johns Hopkins School of Medicine
2 shared publicationsLars Lickfett
Johns Hopkins School of Medicine
2 shared publications
Latest Publications
- 1 February 2007
- Published by Elsevier in Heart Rhythm
- Vol. 4 (2) , 208-214
Characterization of acute and subacute radiofrequency ablation lesions with nonenhanced magnetic resonance imaging
- 1 February 2007
- Published by Elsevier in Heart Rhythm
- Vol. 4 (2) , 208-214
Characterization of acute and subacute radiofrequency ablation lesions with nonenhanced magnetic resonance imaging
- 1 April 2005
- Published by Elsevier in Heart Rhythm
- Vol. 2 (4) , 413-415
Stereotactic catheter navigation using magnetic resonance image integration in the human heart
- 1 April 2005
- Published by Elsevier in Heart Rhythm
- Vol. 2 (4) , 413-415
Stereotactic catheter navigation using magnetic resonance image integration in the human heart
- 1 October 2004
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 11 (2) , 105-115
Stereotactic Magnetic Resonance Guidance for Anatomically Targeted Ablations of the Fossa Ovalis and the Left Atrium
Introduction:Targets for radiofrequency ablation (RFA) of atrial fibrillation are increasingly being selected based on anatomic considerations. Because fluoroscopy provides only limited information...
- 1 October 2004
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 11 (2) , 105-115
Stereotactic Magnetic Resonance Guidance for Anatomically Targeted Ablations of the Fossa Ovalis and the Left Atrium
Introduction:Targets for radiofrequency ablation (RFA) of atrial fibrillation are increasingly being selected based on anatomic considerations. Because fluoroscopy provides only limited information...
- 11 November 2003
- Published by Wolters Kluwer Health in Circulation
- Vol. 108 (19) , 2407-2413
Anatomic Stereotactic Catheter Ablation on Three-Dimensional Magnetic Resonance Images in Real Time
Background— Targets for radiofrequency (RF) ablation of atrial fibrillation, atrial flutter, and nonidiopathic ventricular tachycardia are increasingly being selected on the basis of anatomic considerations. Because fluoroscopy provides only limited information about the relationship between catheter positions and cardiac structures and is associated with radiation risk, other approaches to mapping may be beneficial. Methods and Results— An electromagnetic catheter positioning system was superimposed on 3D MR images using fiducial markers. This allowed the dynamic display of the catheter position on the true anatomy of previously acquired MR images in real time. In vitro accuracy and precision during catheter navigation were assessed in a phantom model and were 1.11±0.06 and 0.30±0.07 mm (mean±SEM), respectively. Left and right heart catheterization was performed in 7 swine without the use of fluoroscopy, yielding an in vivo accuracy and precision of 2.74±0.52 and 1.97±0.44 mm, respectively. To assess the reproducibility of RF ablation, RF lesions were created repeatedly at the identical anatomic site in the right atrium (n=8 swine). Average distance of the repeated right atrial ablations was 3.92±0.5 mm. Straight 3-point lines were created in the right and left ventricles to determine the ability to facilitate complex ablation procedures (n=6 swine). The ventricular lesions deviated 1.70±0.24 mm from a straight line, and the point distance differed by 2.25±0.63 mm from the pathological specimen. Conclusions— Real-time display of the catheter position on 3D MRI allows accurate and precise RF ablation guided by the true anatomy. This may facilitate anatomically based ablation procedures in, for instance, atrial fibrillation or nonidiopathic ventricular tachycardia and decrease radiation times.
- 11 November 2003
- Published by Wolters Kluwer Health in Circulation
- Vol. 108 (19) , 2407-2413
Anatomic Stereotactic Catheter Ablation on Three-Dimensional Magnetic Resonance Images in Real Time
Background— Targets for radiofrequency (RF) ablation of atrial fibrillation, atrial flutter, and nonidiopathic ventricular tachycardia are increasingly being selected on the basis of anatomic considerations. Because fluoroscopy provides only limited information about the relationship between catheter positions and cardiac structures and is associated with radiation risk, other approaches to mapping may be beneficial. Methods and Results— An electromagnetic catheter positioning system was superimposed on 3D MR images using fiducial markers. This allowed the dynamic display of the catheter position on the true anatomy of previously acquired MR images in real time. In vitro accuracy and precision during catheter navigation were assessed in a phantom model and were 1.11±0.06 and 0.30±0.07 mm (mean±SEM), respectively. Left and right heart catheterization was performed in 7 swine without the use of fluoroscopy, yielding an in vivo accuracy and precision of 2.74±0.52 and 1.97±0.44 mm, respectively. To assess the reproducibility of RF ablation, RF lesions were created repeatedly at the identical anatomic site in the right atrium (n=8 swine). Average distance of the repeated right atrial ablations was 3.92±0.5 mm. Straight 3-point lines were created in the right and left ventricles to determine the ability to facilitate complex ablation procedures (n=6 swine). The ventricular lesions deviated 1.70±0.24 mm from a straight line, and the point distance differed by 2.25±0.63 mm from the pathological specimen. Conclusions— Real-time display of the catheter position on 3D MRI allows accurate and precise RF ablation guided by the true anatomy. This may facilitate anatomically based ablation procedures in, for instance, atrial fibrillation or nonidiopathic ventricular tachycardia and decrease radiation times.