Ashish Doorwar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ashish Doorwar has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bhavesh Rameshchandra Bhalja
Department of Electrical Engineering, Indian Institute of Technology Roorkee, Roorkee, India
3 shared publications - Om Parkash Malik
University of Calgary, Canada
3 shared publications Bhavesh Bhalja
Electrical & Computer Engineering, Texas A&M University, Texas, USA
1 shared publicationChirag H. Rovai
Dept. of Electrical Engineering, AITS Rajkot, India
1 shared publicationD. R. Tutakne
Department of Electrical Engineering, G. H. Raisoni College of Engineering, Nagpur, India
1 shared publicationGajanan C. Jaiswal
Shri Ramdeobaba College of Engineering & Management, Nagpur, India
1 shared publication
Latest Publications
- 7 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (4) , 2094-2104
Improved Protection Scheme Based on D-q Components for Synchronous Generator
A protection scheme for detecting and classifying internal faults in synchronous generators (SGs) based on the calculation of d-q components of stator currents at neutral and terminal ends is presented in this paper. Detection of internal faults is achieved based on the rate of change of q component of the stator current at the neutral end compared to a pre-defined threshold. Thereafter, discrimination between internal faults and external conditions is obtained by taking the difference of rate of change of q component at the terminal and neutral ends. Subsequently, internal fault classification is carried out based on the rate of change of zero component of the neutral end current. The proposed scheme is validated using various fault cases obtained from a simulation network developed in a real-time digital simulator (RTDS) as well as from an experimental setup of the SG. The proposed scheme can detect all types of internal faults, including inter-turn faults, regardless of the generator winding configuration for low-resistance grounded SGs. It is also capable of distinguishing internal faults from external conditions within a quarter cycle, independent of current transformer errors and saturation, as well as variable loading conditions and SG ratings.
- 7 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (4) , 2094-2104
Improved Protection Scheme Based on D-q Components for Synchronous Generator
A protection scheme for detecting and classifying internal faults in synchronous generators (SGs) based on the calculation of d-q components of stator currents at neutral and terminal ends is presented in this paper. Detection of internal faults is achieved based on the rate of change of q component of the stator current at the neutral end compared to a pre-defined threshold. Thereafter, discrimination between internal faults and external conditions is obtained by taking the difference of rate of change of q component at the terminal and neutral ends. Subsequently, internal fault classification is carried out based on the rate of change of zero component of the neutral end current. The proposed scheme is validated using various fault cases obtained from a simulation network developed in a real-time digital simulator (RTDS) as well as from an experimental setup of the SG. The proposed scheme can detect all types of internal faults, including inter-turn faults, regardless of the generator winding configuration for low-resistance grounded SGs. It is also capable of distinguishing internal faults from external conditions within a quarter cycle, independent of current transformer errors and saturation, as well as variable loading conditions and SG ratings.
- 3 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (1) , 180-191
Novel Approach for Synchronous Generator Protection Using New Differential Component
A new stator fault detection and classification scheme for synchronous generators (SGs), based on an amplified discrete Teager-kaiser energy operator (ADTKEO) of a new differential component ( DCSI ), is proposed. Detection of an internal fault is based on the fulfillment of the ADTKEO ( ξ ) with respect to the pre-determined threshold along with the checking of second-harmonic content in the current transformer (CT) secondary current. Afterward, the classification of internal faults is performed based on ‘ ξ ’. The performance of the proposed scheme is tested on various fault cases obtained from a simulation network developed in a real-time digital simulator and the developed laboratory prototype of the SG. The results indicate that the proposed scheme not only provides 100% winding coverage against phase-to-ground faults but is also capable of detecting other phase faults within a quarter cycle for low-resistance grounded SGs. At the same time, it stays extremely stable for external faults, even considering errors in CT along with its saturation (without compromising speed/sensitivity). The proposed scheme is independent of the sampling frequency, loading condition, decaying dc component present in the acquired signals, and rating of the SG.
- 3 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (1) , 180-191
Novel Approach for Synchronous Generator Protection Using New Differential Component
A new stator fault detection and classification scheme for synchronous generators (SGs), based on an amplified discrete Teager-kaiser energy operator (ADTKEO) of a new differential component ( DCSI ), is proposed. Detection of an internal fault is based on the fulfillment of the ADTKEO ( ξ ) with respect to the pre-determined threshold along with the checking of second-harmonic content in the current transformer (CT) secondary current. Afterward, the classification of internal faults is performed based on ‘ ξ ’. The performance of the proposed scheme is tested on various fault cases obtained from a simulation network developed in a real-time digital simulator and the developed laboratory prototype of the SG. The results indicate that the proposed scheme not only provides 100% winding coverage against phase-to-ground faults but is also capable of detecting other phase faults within a quarter cycle for low-resistance grounded SGs. At the same time, it stays extremely stable for external faults, even considering errors in CT along with its saturation (without compromising speed/sensitivity). The proposed scheme is independent of the sampling frequency, loading condition, decaying dc component present in the acquired signals, and rating of the SG.
- 1 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Half Cycle Negative Sequence Differential Protection for Synchronous Generator
In this paper, a half cycle negative-sequence differential protection principle for internal faults in synchronous generators is presented. In the presented scheme, a new modified half-cycle discrete Fourier transform (DFT)-based phasor estimation algorithm is used. This scheme has many advantages over conventional differential protection (87P) in terms of sensitivity, speed, security, and reliability. The presented technique has been verified on a Phase Domain Synchronous Machine model simulated on the Real Time Digital Simulator (RTDS ® ). The analysis of congregated fault dataset clearly shows that the scheme is able to discriminate well between internal and external faults even during current transformer saturation, unbalance condition and overloading.
- 1 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Half Cycle Negative Sequence Differential Protection for Synchronous Generator
In this paper, a half cycle negative-sequence differential protection principle for internal faults in synchronous generators is presented. In the presented scheme, a new modified half-cycle discrete Fourier transform (DFT)-based phasor estimation algorithm is used. This scheme has many advantages over conventional differential protection (87P) in terms of sensitivity, speed, security, and reliability. The presented technique has been verified on a Phase Domain Synchronous Machine model simulated on the Real Time Digital Simulator (RTDS ® ). The analysis of congregated fault dataset clearly shows that the scheme is able to discriminate well between internal and external faults even during current transformer saturation, unbalance condition and overloading.
- 5 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (2) , 739-749
A New Internal Fault Detection and Classification Technique for Synchronous Generator
A new internal fault detection and classification technique for synchronous generators is presented. First, the presence of an abnormal/fault condition is detected based on the Negative Sequence Component (NSC) of neutral end current. Thereafter, the internal fault and abnormal/external-fault conditions are discriminated by utilizing the instantaneous phase angle between the NSCs of the terminal voltage and current. Subsequently, the internal fault is classified based on phase angle between NSCs of terminal voltage and neutral end current along with the zero sequence component of the neutral end current. Efficacy of the proposed scheme has been verified on a Phase Domain Synchronous Machine model developed on the Real Time Digital Simulator (RTDS®). The results derived from various fault data sets show that the proposed technique is able to effectively distinguish between internal and external faults including special cases such as current transformer saturation, overloading and unbalance condition. Further, it provides added capability of detecting and identifying inter-turn faults irrespective of the winding configuration of the generator. Comparative assessment of the proposed scheme in terms of detection time and incorporation of different types of faults with the existing techniques proves its superiority.
- 5 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (2) , 739-749
A New Internal Fault Detection and Classification Technique for Synchronous Generator
A new internal fault detection and classification technique for synchronous generators is presented. First, the presence of an abnormal/fault condition is detected based on the Negative Sequence Component (NSC) of neutral end current. Thereafter, the internal fault and abnormal/external-fault conditions are discriminated by utilizing the instantaneous phase angle between the NSCs of the terminal voltage and current. Subsequently, the internal fault is classified based on phase angle between NSCs of terminal voltage and neutral end current along with the zero sequence component of the neutral end current. Efficacy of the proposed scheme has been verified on a Phase Domain Synchronous Machine model developed on the Real Time Digital Simulator (RTDS®). The results derived from various fault data sets show that the proposed technique is able to effectively distinguish between internal and external faults including special cases such as current transformer saturation, overloading and unbalance condition. Further, it provides added capability of detecting and identifying inter-turn faults irrespective of the winding configuration of the generator. Comparative assessment of the proposed scheme in terms of detection time and incorporation of different types of faults with the existing techniques proves its superiority.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 209-214
A Review of Diagnostic Tests and Condition Monitoring Techniques for Improving the Reliability of Power Transformers
Power transformer is a critical component for generation, transmission and distribution utility. It is expensive equipment and plays vital role in interconnecting renewable energy with main grid. The distribution transformers are installed at different locations in a power system and are critical assets in the electricity supply system as they feed power supply to the end users. In this era of deregulation, priority is given by utilities for uninterrupted and quality power supply to their consumers. However, distribution transformers are normally neglected components; less maintenance and less care have been taken in comparison with power transformers. Transformer failure causes extensive loss to the power utility, major industrial consumer and society. Proper operation and maintenance procedure may avoid failures and maintain the continuous power supply for end user. Due to these reasons conditioning monitoring of transformer become popular. Condition monitoring of transformer results in increase life span, reducing the risk of expensive equipments failure and increase high level reliability. An overview of various traditional and some new conditioning monitoring techniques are covered in this paper. The methods discussed in this paper are useful for both the power transformers and distribution transformers.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 209-214
A Review of Diagnostic Tests and Condition Monitoring Techniques for Improving the Reliability of Power Transformers
Power transformer is a critical component for generation, transmission and distribution utility. It is expensive equipment and plays vital role in interconnecting renewable energy with main grid. The distribution transformers are installed at different locations in a power system and are critical assets in the electricity supply system as they feed power supply to the end users. In this era of deregulation, priority is given by utilities for uninterrupted and quality power supply to their consumers. However, distribution transformers are normally neglected components; less maintenance and less care have been taken in comparison with power transformers. Transformer failure causes extensive loss to the power utility, major industrial consumer and society. Proper operation and maintenance procedure may avoid failures and maintain the continuous power supply for end user. Due to these reasons conditioning monitoring of transformer become popular. Condition monitoring of transformer results in increase life span, reducing the risk of expensive equipments failure and increase high level reliability. An overview of various traditional and some new conditioning monitoring techniques are covered in this paper. The methods discussed in this paper are useful for both the power transformers and distribution transformers.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 53-57
An overview of various control techniques of DVR
Power quality is the major concern in today's electrical power system. Especially, power quality problems are continuously observed in distributed electrical power system. Mainly the voltage quality is the major aspect in distributed electrical power system. Voltage sags and voltage swells are the main parameters on which the improvement is needed. Voltage quality can be sufficiently improved in distributed electrical power systems by using some custom power devices such as dynamic voltage restorer. The Dynamic Voltage Restorer (DVR) is fast, flexible and efficient solution to voltage sag and voltage swell problems. The DVR is a power electronic based device that provides three-phase controllable voltage output, whose voltage vector-magnitude and angle-adds to the supply voltage during sag event, to restore the load voltage to pre-sag conditions. And when voltage swell occurs DVR injects 180° out of phase voltage into the line. The DVR is designed for protecting the whole plant with loads in the range of some MVA. The DVR can restore the load voltage within few milliseconds.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 53-57
An overview of various control techniques of DVR
Power quality is the major concern in today's electrical power system. Especially, power quality problems are continuously observed in distributed electrical power system. Mainly the voltage quality is the major aspect in distributed electrical power system. Voltage sags and voltage swells are the main parameters on which the improvement is needed. Voltage quality can be sufficiently improved in distributed electrical power systems by using some custom power devices such as dynamic voltage restorer. The Dynamic Voltage Restorer (DVR) is fast, flexible and efficient solution to voltage sag and voltage swell problems. The DVR is a power electronic based device that provides three-phase controllable voltage output, whose voltage vector-magnitude and angle-adds to the supply voltage during sag event, to restore the load voltage to pre-sag conditions. And when voltage swell occurs DVR injects 180° out of phase voltage into the line. The DVR is designed for protecting the whole plant with loads in the range of some MVA. The DVR can restore the load voltage within few milliseconds.