JWJakob Weiss

Jakob Weiss

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jakob Weiss has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Impact of Focus and Context Visualization Techniques on Depth Perception in Optical See-Through Head-Mounted Displays

    by Alejandro Martin-Gomez, Jakob Weiss, Andreas Keller, Ulrich Eck, Daniel Roth, Nassir Navab

    Estimating the depth of virtual content has proven to be a challenging task in Augmented Reality (AR) applications. Existing studies have shown that the visual system makes use of multiple depth cues to infer the distance of objects, occlusion being one of the most important ones. The ability to generate appropriate occlusions becomes particularly important for AR applications that require the visualization of augmented objects placed below a real surface. Examples of these applications are medical scenarios in which the visualization of anatomical information needs to be observed within the patient's body. In this regard, existing works have proposed several focus and context ( F+C ) approaches to aid users in visualizing this content using Video See-Through (VST) Head-Mounted Displays (HMDs). However, the implementation of these approaches in Optical See-Through (OST) HMDs remains an open question due to the additive characteristics of the display technology. In this article, we, for the first time, design and conduct a user study that compares depth estimation between VST and OST HMDs using existing in-situ visualization methods. Our results show that these visualizations cannot be directly transferred to OST displays without increasing error in depth perception tasks. To tackle this gap, we perform a structured decomposition of the visual properties of AR F+C methods to find best-performing combinations. We propose the use of chromatic shadows and hatching approaches transferred from computer graphics. In a second study, we perform a factorized analysis of these combinations, showing that varying the shading type and using colored shadows can lead to better depth estimation when using OST HMDs.


  • Evaluating surface visualization methods in semi-transparent volume rendering in virtual reality

    by Gloria Zörnack, Jakob Weiss, Georg Schummers, Ulrich Eck, Nassir Navab

    Perceptual visualisation of semi-transparent structures in volumetric datasets is challenging due to its inherent visual complexity. This is however of primary importance in medical visualisation where raymarching of volumetric data is common. While rendering volumetric data itself is a well-explored area, perception of volume-rendered images combined with semi-transparent mesh data remains an underexplored topic. As virtual reality (VR) is increasingly employed for medical data inspection, it becomes important to understand how different mesh visualisations affect performance in medical tasks in this context. When considering direct volume rendering in immersive VR, the effects of stereoscopic vision and motion parallax require additional consideration. We investigate how surface transparency modes affect task performance in VR. For two medical image analysis tasks, we conduct a user study (n = 23) to analyse the impact of mesh rendering methods on task outcome and subjective preference. Our evaluation indicates that user performance with wireframe rendering varies greatly between tasks while constant opacity and silhouette provide a stable benefit. Overall, transparent visualisations led to improved precision (lower error rate, lower inter-observer variability) and increased user confidence, while the efficiency of visualisation methods was task-dependent. This demonstrates how semi-transparent rendering will improve visual analysis in medical applications and other disciplines n=23.


  • Processing-Aware Real-Time Rendering for Optimized Tissue Visualization in Intraoperative 4D OCT

    by Jakob Weiss, Michael Sommersperger, Ali Nasseri, Abouzar Eslami, Ulrich Eck, Nassir Navab

    Intraoperative Optical Coherence Tomography (iOCT) has advanced in recent years to provide real-time high resolution volumetric imaging for ophthalmic surgery. It enables real-time 3D feedback during precise surgical maneuvers. Intraoperative 4D OCT generally exhibits lower signal-to-noise ratio compared to diagnostic OCT and visualization is complicated by instrument shadows occluding retinal tissue. Additional constraints of processing data rates upwards of 6 GB/s create unique challenges for advanced visualization of 4D OCT. Prior approaches for real-time 4D iOCT rendering have been limited to applying simple denoising filters and colorization to improve visualization. We present a novel real-time rendering pipeline that provides enhanced intraoperative visualization and is specifically designed for the high data rates of 4D iOCT. We decompose the volume into a static part consisting of the retinal tissue and a dynamic part including the instrument. Aligning the static parts over time allows temporal compounding of these structures for improved image quality. We employ a translational motion model and use axial projection images to reduce the dimensionality of the alignment. A model-based instrument segmentation on the projections discriminates static from dynamic parts and is used to exclude instruments from the compounding. Our real-time rendering method combines the compounded static information with the latest iOCT data to provide a visualization which compensates instrument shadows and improves instrument visibility. We evaluate the individual parts of our pipeline on pre-recorded OCT volumes and demonstrate the effectiveness of our method on a recorded volume sequence with a moving retinal forceps.


  • Towards Robotic Eye Surgery: Marker-Free, Online Hand-Eye Calibration Using Optical Coherence Tomography Images

    by Mingchuan Zhou, Mahdi Hamad, Jakob Weiss, Abouzar Eslami, Kai Huang, Mathias Maier, Chris P. Lohmann, Nassir Navab, Alois Knoll, M. Ali Nasseri

    Ophthalmic microsurgery is known to be a challenging operation, which requires very precise and dexterous manipulation. Image guided robot-assisted surgery (RAS) is a promising solution that brings significant improvements in outcomes and reduces the physical limitations of human surgeons. However, this technology must be further developed before it can be routinely used in clinics. One of the problems is the lack of proper calibration between the robotic manipulator and appropriate imaging device. In this work, we developed a flexible framework for hand-eye calibration of an ophthalmic robot with a microscope-integrated Optical Coherence Tomography (MI-OCT) without any markers. The proposed method consists of three main steps: a) we estimate the OCT calibration parameters; b) with micro-scale displacements controlled by the robot, we detect and segment the needle tip in 3D-OCT volume; c) we find the transformation between the coordinate system of the OCT camera and the coordinate system of the robot. We verified the capability of our framework in ex-vivo pig eye experiments and compared the results with a reference method (marker-based). In all experiments, our method showed a small difference from the marker based method, with a mean calibration error of 9.2 μm and 7.0 μm, respectively. Additionally, the noise test shows the \Revise{robustness} of the proposed method.


  • Fast 5DOF needle tracking in iOCT

    by Jakob Weiss, Nicola Rieke, Mohammad Ali Nasseri, Mathias Maier, Abouzar Eslami, Nassir Navab

    Purpose Intraoperative optical coherence tomography (iOCT) is an increasingly available imaging technique for ophthalmic microsurgery that provides high-resolution cross-sectional information of the surgical scene. We propose to build on its desirable qualities and present a method for tracking the orientation and location of a surgical needle. Thereby, we enable the direct analysis of instrument–tissue interaction directly in OCT space without complex multimodal calibration that would be required with traditional instrument tracking methods. Method The intersection of the needle with the iOCT scan is detected by a peculiar multistep ellipse fitting that takes advantage of the directionality of the modality. The geometric modeling allows us to use the ellipse parameters and provide them into a latency-aware estimator to infer the 5DOF pose during needle movement. Results Experiments on phantom data and ex vivo porcine eyes indicate that the algorithm retains angular precision especially during lateral needle movement and provides a more robust and consistent estimation than baseline methods. Conclusion Using solely cross-sectional iOCT information, we are able to successfully and robustly estimate a 5DOF pose of the instrument in less than 5.4 ms on a CPU.


  • Open Access

    Fast 5DOF Needle Tracking in iOCT

    by Jakob Weiss, Nicola Rieke, Mohammad Ali Nasseri, Mathias Maier, Abouzar Eslami, Nassir Navab

    Purpose. Intraoperative Optical Coherence Tomography (iOCT) is an increasingly available imaging technique for ophthalmic microsurgery that provides high-resolution cross-sectional information of the surgical scene. We propose to build on its desirable qualities and present a method for tracking the orientation and location of a surgical needle. Thereby, we enable direct analysis of instrument-tissue interaction directly in OCT space without complex multimodal calibration that would be required with traditional instrument tracking methods. Method. The intersection of the needle with the iOCT scan is detected by a peculiar multi-step ellipse fitting that takes advantage of the directionality of the modality. The geometric modelling allows us to use the ellipse parameters and provide them into a latency aware estimator to infer the 5DOF pose during needle movement. Results. Experiments on phantom data and ex-vivo porcine eyes indicate that the algorithm retains angular precision especially during lateral needle movement and provides a more robust and consistent estimation than baseline methods. Conclusion. Using solely crosssectional iOCT information, we are able to successfully and robustly estimate a 5DOF pose of the instrument in less than 5.5 ms on a CPU.