RXRenfeng Xu

Renfeng Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Renfeng Xu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Small-pupil versus multifocal strategies for expanding depth of focus of presbyopic eyes

    by Renfeng Xu, Huachun Wang, Matt Jaskulski, Pete Kollbaum, Arthur Bradley

    To compare the visually weighted image quality and depth of focus achieved with small-pupil and multifocal strategies for expanding depth of focus of presbyopic or pseudophakic eyes. School of Optometry, Indiana University, Bloomington, USA. Computational modeling. The visual Strehl ratio was computed from monochromatic optical transfer functions over a wide range of primary spherical aberration and defocus levels for pupil diameters ranging from 1.0 mm to 7.0 mm under high photopic light levels (retinal illuminance >900 trolands) and mesopic light levels (2 candelas/m2). Pupil miosis and added spherical aberration were effective at reducing the impact of spherical defocus. With high light levels at which Weber's law makes neural contrast sensitivity independent of retinal illuminance, small pupils (eg, 1.0 to 3.0 mm) generated higher peak image quality and more effective expansion of depth of focus than the small-pupil multifocal model. However, under low light levels at which the reduced retinal illuminance associated with pupil miosis lowered neural contrast sensitivity, the peak image quality was lower with small pupils (1.0 to 1.5 mm) at all aberration levels. Large pupils and high levels of spherical aberration were most effective at expanding the depth of focus under mesopic light levels. When reductions in retinal illuminance created by pupil miosis have no effect on neural contrast sensitivity, small pupils produced higher image quality and larger depth of focus than multifocal optics and large pupils. In general, the reverse was true under mesopic light conditions.


  • Small Text on Product Labels Poses a Special Challenge for Emerging Presbyopes

    by Renfeng Xu, Erika Chelales, Martin Rickert, Rachel Muessel, Dawn Meyer, Larry N. Thibos, Arthur Bradley, Pete Kollbaum

    SIGNIFICANCE: Approximately 10% of the lowercase text on nonprescription drug labels is smaller than the 1 mm required by the Food and Drug Administration. The small size, combined with the progressive decline in accommodative amplitude and gain, poses a reading challenge for middle‐aged emerging presbyopes. PURPOSE: The purpose of this study was to evaluate the impact of progressing presbyopia and near adds on the ability of middle‐aged patients to read small text routinely encountered on product labels. METHODS: Geometrical optics was used to determine the impact of changing viewing distance, accommodation, and pupil size on retinal blur size. We photographed 261 consumer product labels in grocery, personal care, and nonprescription (over‐the‐counter) drug categories and used character recognition software to identify and size 255,298 printed letters. We computed the impact of viewing distance on the ratio of blur to letter detail and used published blur ratios of ≤4 and ≤2 to identify the conditions that allowed for letter recognition and proficient reading, respectively. RESULTS: Median/mode lowercase letter heights (in millimeters) were 1.39/1.16, 1.29/1.15, and 1.18/1.01, respectively, for groceries, personal care, and over‐the‐counter drug categories. Despite the increased angular subtense of approaching letters, blur ratios generally increased with reduced viewing distance because of increased defocus. Increased viewing distance decreased blur, but small (e.g., 1 mm) letters became too small to read proficiently (angular size <10 arcminutes) for distances beyond 37 cm. With larger pupils, blur ratios were too large to support proficient reading when accommodative amplitude dropped to ≤3 diopters. An add power sufficient to bring the far point closer than 37 cm was required to proficiently read small text. CONCLUSIONS: Product labels, especially nonprescription drug packages, typically use fonts that are too small to be read proficiently by unaided emmetropes with emerging presbyopia. This problem can be ameliorated by correction of presbyopia at an earlier age and with higher add powers.


  • Reducing starbursts in highly aberrated eyes with pupil miosis

    by Renfeng Xu, Pete Kollbaum, Larry Thibos, Norberto Lopez‐Gil, Arthur Bradley

    Purpose: To test the hypothesis that marginal ray deviations determine perceived starburst sizes, and to explore different strategies for decreasing starburst size in highly aberrated eyes. Methods: Perceived size of starburst images and visual acuities were measured psychophysically for eyes with varying levels of spherical aberration, pupil sizes, and defocus. Computationally, we use a polychromatic eye model including the typical levels of higher order aberrations ( HOA s) for keratoconic and post‐ LASIK eyes to quantify the image quality (the visually weighted Strehl ratio derived from the optical transfer function, VSOTF ) with different pupil sizes at both photopic and mesopic light levels. Results: For distance corrected post‐ LASIK and keratoconic eyes with a night‐time pupil (e.g., 7 mm), the starburst diameter is about 1.5 degrees (1 degree for normal presbyopic eyes), which can be reduced to ≤0.25 degrees with pupil sizes ≤3 mm. Starburst size is predicted from the magnitude of the longitudinal spherical aberration. Refracting the eye to focus the pupil margin also removed starbursts, but, unlike small pupils, significantly degraded visual acuity. Reducing pupil diameter to 3 mm improved image quality for these highly aberrated eyes by about 2.7 × to 1.7 × relative to the natural pupils when light levels were varied from 0.1 to 1000 cd m −2 , respectively. Conclusion: Subjects with highly aberrated eyes observed larger starbursts around bright lights at night predictable by the deviated marginal rays. These were effectively attenuated by reducing pupil diameters to ≤3 mm, which did not cause a drop in visual acuity or modelled image quality even at mesopic light levels.


  • Open Access

    Interaction of aberrations, diffraction, and quantal fluctuations determine the impact of pupil size on visual quality

    by Renfeng Xu, Huachun Wang, Larry N. Thibos, Arthur Bradley

    Our purpose is to develop a computational approach that jointly assesses the impact of stimulus luminance and pupil size on visual quality. We compared traditional optical measures of image quality and those that incorporate the impact of retinal illuminance dependent neural contrast sensitivity. Visually weighted image quality was calculated for a presbyopic model eye with representative levels of chromatic and monochromatic aberrations as pupil diameter was varied from 7 to 1 mm, stimulus luminance varied from 2000 to 0.1  cd/m2, and defocus varied from 0 to −2 diopters. The model included the effects of quantal fluctuations on neural contrast sensitivity. We tested the model’s predictions for five cycles per degree gratings by measuring contrast sensitivity at 5  cyc/deg. Unlike the traditional Strehl ratio and the visually weighted area under the modulation transfer function, the visual Strehl ratio derived from the optical transfer function was able to capture the combined impact of optics and quantal noise on visual quality. In a well-focused eye, provided retinal illuminance is held constant as pupil size varies, visual image quality scales approximately as the square root of illuminance because of quantum fluctuations, but optimum pupil size is essentially independent of retinal illuminance and quantum fluctuations. Conversely, when stimulus luminance is held constant (and therefore illuminance varies with pupil size), optimum pupil size increases as luminance decreases, thereby compensating partially for increased quantum fluctuations. However, in the presence of −1 and −2 diopters of defocus and at high photopic levels where Weber’s law operates, optical aberrations and diffraction dominate image quality and pupil optimization. Similar behavior was observed in human observers viewing sinusoidal gratings. Optimum pupil size increases as stimulus luminance drops for the well-focused eye, and the benefits of small pupils for improving defocused image quality remain throughout the photopic and mesopic ranges. However, restricting pupils to <2  mm will cause significant reductions in the best focus vision at low photopic and mesopic luminances.


  • Effect of Target Luminance on Optimum Pupil Diameter for Presbyopic Eyes

    by Renfeng Xu, Larry Thibos, Arthur Bradley

    Purpose: To quantify the optimum pupil diameters for presbyopic eyes when environmental light levels vary from high photopic to low mesopic. Methods: We computed the white light visual Strehl ratio from the polychromatic optical transfer function (VSOTF). The impact on image quality of retinal illuminance and the accompanying changes in photon noise were reflected in changing neural contrast sensitivity. VSOTF was calculated for focused and −2D defocused images, over a wide range of photopic and mesopic target luminances, and for pupil diameters ranging from 1 to 7 mm. We compare these modeling data to logMAR visual acuity measured under the same conditions. Results: Optimum pupil depends on the relative gain of optical factors (diffraction and aberrations) and neural thresholds (photon noise effect). When light levels are reduced from 1000 to 2 cd/m 2 , the pupil size that optimizes VSOTF for a well‐focused presbyopic eye model also maximizes visual acuity and it increases from 2.5 to 4 mm. A 1‐mm‐diameter pupil maximizes VSOTF at all light levels when −2D of defocus are included, but at 2 cd/m 2 the optimum pupil diameter for acuity increases slightly to 1.4 mm. At 0.2 cd/m 2 , the pupil size that optimizes VSOTF remains 4 and 1 mm for a focused and −2D defocused eye, respectively, but significantly larger pupils are needed for maximal visual acuity. Reducing pupils to 30% of their natural size is beneficial for distance and near image quality and visual acuity at all light levels, producing more gains for near than for distance. Conclusions: A fixed 2‐ to 3‐mm small pupil or a 30% pupil miosis can both produce near visual acuity gains without significant losses to distance acuity or image quality, and therefore can be considered as optimal for a presbyope experiencing a wide range of light levels.


  • Open Access

    The Effect of Light Level and Small Pupils on Presbyopic Reading Performance

    by Renfeng Xu, Daniel Gil, Mohammed Dibas, William Hare, Arthur Bradley

    Purpose: To examine the impact of small pupils and light levels on reading performance of distance-corrected presbyopes. To determine whether small pupils would enable presbyopes to read at near even at low light levels. Methods: To establish the lower range of text luminances, we quantified the space-averaged luminance of text in nine different artificially lit interior environments, and examined the impact of the text characters on space-averaged luminance of electronic and printed displays. Distance and near reading speeds of 20 presbyopes (ages 40–60 years) were measured while viewing through artificial pupils (diameters 1–4.5 mm), natural pupils, or with a multifocal contact lens. Space-averaged text luminance levels varied from 0.14 to 140 cd/m2 (including the range of measured environmental text luminances). Results: Adding black text to a white computer display or paper reduces luminance by approximately 15% to 31%, and the lowest encountered environmental text luminance was approximately 2 to 3 cd/m2. For both distance and near reading performance, the 2- to 3-mm small pupil yielded the best overall reading acuity for space-averaged text light levels ≥ 2 cd/m2. The 2- to 3-mm artificial pupils and the multifocal contact lenses both enabled maximum or near-maximum reading speeds for 0.5 logMAR characters at distance and near, but with natural pupils, reading speeds were significantly reduced at near. Conclusions: Although photon noise at low luminance reduces the visual benefits of small pupils, the benefits of 2- to 3-mm artificial pupils are sufficient to enable >80% of distance-corrected presbyopes to read proficiently at near, even at the lowest text luminances found in interior environments.


  • IUR ead: a new computer‐based reading test

    by Renfeng Xu, Arthur Bradley

    Purpose: To develop a computer‐based single sentence reading test especially designed for clinical research enabling multiple repeat trials without reusing the same sentences. Methods: We initially developed 422 sentences, with an average of 60 characters and 12 words. Presentation controls were improved by employing computer‐based testing and the oral reading was recorded by visual inspection of digital audio recordings. Variability in reading speed of normally sighted adults between sentences, between charts, between subjects, between formats, and between display devices was quantified. The impact of display size and pixel resolution on test geometry was assessed, and the impact of reduced retinal image quality and retinal illuminance were compared for reading and standard letter acuities. Eleven visually normal subjects (age: 18–60 years) participated in this study. Results: Stopwatch timing of sentences reliably underestimated reading times by about 0.3 s, and exhibited coefficients of repeatability 17 times larger than those estimated from visual inspection of digital recordings. A slight relaxing of the lexical content constraints had no effect on reading speed; neither did sentence format (single vs three lines) or display size or distance. Within subject standard deviations of reading speed for different sentences were small (between 6% and 9% of the mean speed) requiring only small samples sizes to achieve typical statistical reliability and power when comparing conditions within individual subjects. The greater variability associated with stopwatch timing necessitates larger sample sizes. As defocus and light level were varied, reading acuity and standard letter acuity were highly correlated ( r 2 = 0.99), and reading acuity was slightly better. Discussion: A computer‐based IURead reading test provides a useful reading speed and reading acuity tool for clinical research involving multiple conditions and repeat testing of individual subjects. Ready to use IURead files for use with a computer, tablet or cell phone can be downloaded from our lab website ( https://www.opt.indiana.edu/Bradley/Downloads.aspx ).


  • Modelling the effects of secondary spherical aberration on refractive error, image quality and depth of focus

    by Renfeng Xu, Arthur Bradley, Norberto López Gil, Larry N. Thibos

    Purpose: To examine the role of Zernike secondary spherical aberration and its component terms on refraction, image quality and depth of focus. Methods: Computational methods were used to define wavefronts with controlled levels of r 6 , r 4 and r 2 terms, and image quality associated with these terms for a range of target vergences. Target vergences that generated maximum image quality were used as an objective measures of refractive error. Results: Unlike primary Zernike spherical aberration, which generates peak image quality with a near paraxial focus, in the absence of other higher order aberrations, peak image quality with secondary spherical aberration is achieved with a near marginal focus. When alone, positive primary and secondary spherical aberration induce small hyperopic shifts in refraction, but in the presence of other higher order aberrations, secondary spherical aberration can induce significant myopic shifts in refractive error, as predicted by the combined lower order r 4 & r 2 component of . The predicted expansion in depth of focus associated with increased primary or secondary spherical aberration is mostly absent if a strict image quality criterion is applied. The expansion of depth of focus observed with a low image quality criterion when opposite sign and are combined is primarily due to the elevated r 4 term. Conclusions: Secondary Zernike spherical aberration can have a significant impact on refractive error, image quality and depth of focus, but mostly due to the lower order components within this polynomial. Our analysis shows that the r 6 term that defines secondary spherical aberration actually narrows rather than expands depth of focus, when in the presence of the r 4 term within . Therefore, a multifocal lens generated with exclusively primary spherical aberration is likely to be more effective than one that includes opposite sign of primary and secondary spherical aberration.


  • Impact of primary spherical aberration, spatial frequency and S tiles C rawford apodization on wavefront determined refractive error: a computational study

    by Renfeng Xu, Arthur Bradley, Larry N Thibos

    Purpose: We tested the hypothesis that pupil apodization is the basis for central pupil bias of spherical refractions in eyes with spherical aberration. Methods: We employed Fourier computational optics in which we vary spherical aberration levels, pupil size, and pupil apodization (Stiles Crawford Effect) within the pupil function, from which point spread functions and optical transfer functions were computed. Through‐focus analysis determined the refractive correction that optimized retinal image quality. Results: For a large pupil (7 mm), as spherical aberration levels increase, refractions that optimize the visual Strehl ratio mirror refractions that maximize high spatial frequency modulation in the image and both focus a near paraxial region of the pupil. These refractions are not affected by Stiles Crawford Effect apodization. Refractions that optimize low spatial frequency modulation come close to minimizing wavefront RMS , and vary with level of spherical aberration and Stiles Crawford Effect. In the presence of significant levels of spherical aberration (e.g. = 0.4 μm, 7 mm pupil), low spatial frequency refractions can induce −0.7 D myopic shift compared to high SF refraction, and refractions that maximize image contrast of a three cycle per degree square‐wave grating can cause −0.75 D myopic drift relative to refractions that maximize image sharpness. Discussion: Because of small depth of focus associated with high spatial frequency stimuli, the large change in dioptric power across the pupil caused by spherical aberration limits the effective aperture contributing to the image of high spatial frequencies. Thus, when imaging high spatial frequencies, spherical aberration effectively induces an annular aperture defining that portion of the pupil contributing to a well‐focused image. As spherical focus is manipulated during the refraction procedure, the dimensions of the annular aperture change. Image quality is maximized when the inner radius of the induced annulus falls to zero, thus defining a circular near paraxial region of the pupil that determines refraction outcome.