RMRobinsom Viegas Montenegro

Robinsom Viegas Montenegro

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Robinsom Viegas Montenegro has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Análise epidemiológica de pacientes atendidos em um serviço de controle da dor orofacial

    by Rafaela Dutra Alves, Renata Rocha Barros, Marcella Gouvêa Bezerra Trócoli, Robinsom Viégas Montenegro, Luciana Barbosa Sousa de Lucena, André Ulisses Dantas Batista

    O objetivo deste estudo foi analisar retrospectivamente as fichas clínicas de pacientes encaminhados ao serviço especializado em Dor Orofacial do Hospital Universitário Lauro Wanderley, descrevendo o perfil epidemiológico da população atendida. Trata-se de um estudo retrospectivo baseado na análise de 436 fichas de pacientes atendidos entre 2018 e 2022. Foram avaliados dados pessoais, características sociodemográficas, queixa principal, presença de sinais e sintomas de DTM, tensão emocional, hábitos parafuncionais, postura do sono e músculos sensíveis à palpação. Quanto à ATM, analisaram-se sensibilidade à palpação, grau de abertura, ruídos articulares, trajetória de abertura bucal, além dos tratamentos e encaminhamentos realizados. Os dados foram tabulados e analisados descritivamente no programa SPSS 20.0. A amostra foi composta predominantemente por mulheres (82,6%), com maior concentração na faixa etária de 50 a 59 anos (20,2%), solteiras (41,5%) e com vínculo empregatício (32,6%). A dor foi a queixa mais relatada (84,4%). Houve alta prevalência de DTM moderada (34,4%) e severa (43,6%), e 78% dos pacientes necessitaram de tratamento para DTM. Os níveis de tensão emocional (média 6,82 ± 2,87) e de dor pela escala numérica (7,5 ± 2,46) foram elevados. Cerca de 47,7% apresentaram hábitos parafuncionais. Os músculos mais sensíveis à palpação foram o masseter (58,7%) e o temporal (45,8%). Predominaram tratamentos conservadores e houve alta frequência de encaminhamentos para outros profissionais. Em síntese, o perfil dos pacientes foi majoritariamente de mulheres adultas, solteiras e com queixa de dor, com elevada prevalência de sintomas de DTM, predominância de tratamentos conservadores e necessidade de abordagem multidisciplinar.

  • Open Access

    Monitoramento de unidades fotoativadoras utilizadas nas clínicas do curso de graduação em odontologia da UFPB

    by Renata Rocha Barros, Fernanda Mendes Santana, Iara Petrato Bruck Honório da Silva, Hugo Ramalho Sarmento, Robinsom Viégas Montenegro, Ana Karina Maciel de Andrade, Raquel Venâncio Fernandes Dantas

    Os fotopolimerizadores precisam ter irradiância adequada a fim de ativar os fotoiniciadores presentes na resina composta. Desse modo, este estudo teve como objetivo monitorar a emissão de feixes luminosos das unidades fotoativadoras utilizadas nas clínicas de odontologia da Universidade Federal da Paraíba (UFPB). As mensurações foram aferidas duas vezes ao dia durante dois semestres. Para avaliar a irradiância emitida pelos dispositivos, foi utilizado o radiômetro RD-7 ECEL. A maioria dos dispositivos apresentou emissão radiante superior a 1.000mW/cm2. Na clínica de atendimento infantil e do Departamento de Clínica e Odontologia Social (DCOS) todos os valores obtidos foram acima da potência mínima recomendada (400 mW/cm2). Quanto à clínica do Departamento de Odontologia Restauradora (DOR), apenas um aparelho apresentou um valor inferior (378mW/cm2). Concluiu-se que a maioria dos fotopolimerizadores emitiram luz superior ao valor mínimo esperado. Houve diferença entre os modelos de unidades fotoativadoras testados neste estudo no momento em que a sua bateria estava fraca, por isso, foi sugerido um protocolo de carregamento dos aparelhos para que a chance de um dispositivo descarregar durante o atendimento seja minimizada.

    • 1 April 2022
      • Vol. 35  (2) , 89-96

    Longevity of bulk fill and ormocer composites in permanent posterior teeth: Systematic review and meta-analysis

    by Nathalie Murielly Rolim De Abreu, Frederico Barbosa De Sousa, Raquel Venancio Fernandes Dantas, Priscilla Kelly Batista Da Silva Leite, Andre Ulisses Dantas Batista, Robinsom Viegas Montenegro

    Purpose: To evaluate the clinical longevity of bulk-fill resins and ormocer composites compared to conventional nanofill and nanohybrid resins in posterior permanent teeth. Methods: PubMed, Web of Science, Scopus, Science Direct, Cochrane Library, and Scielo were electronically searched for randomized clinical trials, without language restrictions. The extracted data were analyzed using Review Manager, comparing the clinical behavior of bulk fill or ormocer restorations with nanofill or nanohybrid resins. Statistical analysis was performed with a significance level of 5% for all analyses (P= 0.05). The risk of bias was assessed using the Cochrane assessment tool. Results: 11 randomized clinical trials were included, with an average follow-up time of 40.36 months. A total of 812 restorations were evaluated and 58 failures were analyzed: 18 of the 253 bulk-fill restorations (7.11%), 21 of the 173 (12.3%) ormocer restorations, and 20 of the 386 (5.18%) control group (nanofill or nanohybrid composites) restorations failed. In the meta-analysis, there was no significant difference between the bulk-fill and the control group (statistical power = 24.38%; P= 0.206; IC = 95%); whereas, when comparing between ormocer and control group, the control group exhibited better performance (statistical power = 81.62%; P= 0.0042; IC = 95%).


  • Polishing Methods' Influence on Color Stability and Roughness of 2 Provisional Prosthodontic Materials

    by Irenaldo André Soares, Priscilla Kelly Batista da Silva Leite, Ohana Rodrigues Farias, George Azevedo Lemos, André Ulisses Dantas Batista, Robinsom Viegas Montenegro

    Purpose: To evaluate the roughness and color change of a conventional acrylic resin and a bis‐acryl resin, submitted to different types of polishing and exposed to a staining solution.Materials and Methods: One hundred specimens were manufactured from an autopolymerizing conventional acrylic resin (Duralay, shade 66) (n = 50) and a bis‐acryl resin (Protemp 4, shade A3) (n = 50) according to the manufacturers’ instructions. Specimens were subdivided into 10 groups (n = 10), according to the type of resin and polishing method, including no‐polishing (control groups for acrylic resin [tungsten bur finishing] and bis‐acryl resin [cotton and alcohol]), Enhance System, Edenta kit, Labordental kit, and sandpaper. The specimens were immersed in a staining solution (coffee at 60°C) for 7 days. Surface roughness was evaluated before the first immersion (baseline – Ra1) and after 7 days (Ra2). The color change (∆E) was determined after 24 hours (∆E1) and 7 days (∆E2), by CIE L* a* b* scale. Data were statistically analyzed with 3‐way ANOVA for repeated measures test and Tukey test (α = 0.05).Results: According to 3‐way ANOVA test, material, polishing techniques, and polishing*material factors exhibited statistically significant influence (p < 0.0001) on the roughness, and, for color change, material, polishing techniques, time, polishing*material, and material*time factors were statistically significant (p < 0.0001). The polishing techniques successfully reduced the surface roughness of acrylic resin groups, when compared to control (p < 0.001), but for bis‐acryl resin, results were not different from the control group (Enhance: p = 0.954, Edenta: p = 0.866, sandpaper: p = 0.366, Labordental: p = 0.945). Surface roughness was not affected by the immersion in staining solution for 7 days. Color change of acrylic resin groups after 24 hours and 7 days of immersion exhibited a clinically acceptable value (ΔE < 3.7) with the exception of the Enhance group, and all bis‐acryl resin groups exhibited a clinically unacceptable color change value (ΔE > 3.7) independent of polishing technique and time interval (∆E1 and ∆E2).Conclusions: Roughness of both materials was similar when the polishing techniques studied were performed, although Ra values were superior to the clinically acceptable values (0.20 µm), and were not affected by the immersion protocol studied; however, when esthetics are critical, the selection of material type is more important than the surface treatment technique used, and bis‐acryl resin was more susceptible to clinically unacceptable color change after immersion in a staining solution.


  • Open Access

    Effect of water storage on microshear bond strength of four dental adhesive systems to dentin

    by Robinson Viegas Montenegro, Hugo Lemes Carlo, André Ulisses Dantas Batista, Sheyla Christinne Lira Montenegro, Ohana Rodrigues Farias

    AIM: To evaluate the microshear bond strength of 4 dental adhesive systems after 1 year-water storage. MATERIAL AND METHODS: The sample consisted of 120 cylinders of composite, obtained from 24 bovine incisors, which were divided into four experimental groups: G1-Scotchbond Multi-Purpose, G2-Single Bond 2, G3-Clearfil SE Bond, G4-Adper Easy One and two storage times in distilled water: T0 - 24h and T1 - 1 year. A bivariate analysis was performed using the ANOVA and Tukey test (α=0.05). Results were evaluated inter-and intra-group in both times. RESULTS: After 24 hours, G1T0 (39.68A ± 11.55) showed higher bond strength (MPa) followed by G2T0 (22.71B ± 4.07), G3T0 (18.94BC ± 7.29) and G4T0 (13.30C ± 3.94). After 1 year of storage only G1T1 (33.95A ± 6.35) and G3T1 (13.59BC ± 2.63) maintained the bond strength values (p ≥ 0.05), while G2T1 (10.62C ± 4.32) and G4T1 (4.49D ± 2.49) presented a decrease in this values. CONCLUSION: The hydrophobic two-step adhesive systems maintained the bond strength after 1-year water storage.