ACAndrés Felipe Carrera-Pinzón

Andrés Felipe Carrera-Pinzón

*This is an algorithmically generated author record based on publicly available information.

Andrés Felipe Carrera-Pinzón has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Correlation of intraventricular blood patterns with the Ejection Fraction in ultrasound images

    by Andrés Felipe Carrera-Pinzón, Leonard Toro-Quitian, Marcela Iregui Guerrero, Angel Cruz-Roa, R.E Gutiérrez-Carvajal, Eduardo Romero

    Currently, the cardiac dynamic of the entire cycle is not characterized and heart function is approximated by volumetric relationships in specific moments of the cycle. This work represents the left ventricular cardiac dynamics by intraventricular motion patterns in echocardiographic images. Briefly, after segmenting the ventricular cavity, intensity levels within this region of interest are spatially grouped by a classic superpixel (SP) clustering method, aiming to maximize the intergroup variance with a minimum number of groups. The distribution of these superpixels is then correlated with different cycle times, specifically diastole and systole. A total of 70 cases, half with Ejection Fraction (EF) less than 40 % and half with control EF (higher than 50 %), were processed and results demonstrated the number of groups is significantly smaller in cases with control EF, indicating that intraventricular patterns are correlated with the EF.

  • Computational model of a synovial joint morphogenesis

    by Andrés Felipe Carrera-Pinzón, Kalenia Márquez-Flórez, Reuben H. Kraft, Salah Ramtani, Diego Alexander Garzón-Alvarado

    Joints enable the relative movement between the connected bones. The shape of the joint is important for the joint movements since they facilitate and smooth the relative displacement of the joint’s parts. The process of how the joints obtain their final shape is yet not well understood. Former models have been developed in order to understand the joint morphogenesis leaning only on the mechanical environment; however, the obtained final anatomical shape does not match entirely with a realistic geometry. In this study, a computational model was developed with the aim of explaining how the morphogenesis of joints and shaping of ossification structures are achieved. For this model, both the mechanical and biochemical environments were considered. It was assumed that cartilage growth was controlled by cyclic hydrostatic stress and inhibited by octahedral shear stress. In addition, molecules such as PTHrP and Wnt promote chondrocyte proliferation and therefore cartilage growth. Moreover, the appearance of the primary and secondary ossification centers was also modeled, for which the osteogenic index and PTHrP–Ihh concentrations were taken into account. The obtained results from this model show a coherent final shape of an interphalangeal joint, which suggest that the mechanical and biochemical environments are crucial for the joint morphogenesis process.


  • Open Access

    Development of an easy-to-assemble external fixation system for bone transport

    by Fernando Casanova Garcia, Andres Carrera Pinzon, Arlex Leyton, Andres Machado Caicedo, Jose Jaime GarcIa Alvarez

    We developed a monolateral external fixation system for bone elongation easier to assemble than commercial systems since the clamps can be laterally assembled to the rail in contrast to the commercial systems where the clamps can only be assembled from the ends. The system is formed by clamps, screws, and a rail. The rail is composed of two carbon fiber circular rods of ½” diameter and 42-cm length. The clamps can slide with respect to the rail to allow bone distraction or may be fixed to the rail by using a wedge and a screw. The prototype was mechanically evaluated under the ASTM F1541 standard. The stiffness in axial, Medio Lateral bending (ML), Antero Posterior bending (AP), and flexo-torsional load were 117 N/mm, 46 N/mm, 8.7 N/mm, and 5.8 N-mm/°, respectively, which are on the range of stiffness of commercial systems.