Latest Publications

  • Open Access

    From point sources to phantoms: refining dose rate models in nuclear medicine with Tc-99m, F-18, I-131 and Lu-177

    by Joshua Ierace, Pejman Rowshanfarzad, Christine Sinnott, Rikki Nezich, Paul Brayshaw, Mario Djukelic

    Healthcare workers are often exposed to external radiation from patients who have been administered radionuclides for nuclear medicine (NM) studies, particularly during subsequent procedures requiring close contact. Traditional dose rate estimates commonly assume patients to be unattenuated point sources and apply inverse square law calculations, which tend to overestimate exposures at clinical distances. This study presents an experimental approach to quantify dose rates more accurately from NM patients using point, line, and phantom source models of Tc-99m, F-18, I-131, and Lu-177. Measurements were performed with calibrated ionisation chambers under controlled low-background conditions. Radionuclide activities were selected to achieve detectable dose rates while minimising staff exposure. Point and line source measurements provided baseline external exposure data across 10–100 cm. Phantom models, including a homogeneous water-filled NEMA body phantom and a PMMA neck phantom, were used to replicate clinical patient geometries. Dose rates were decay-corrected, normalised to activity, and fitted with biexponential models to generate exposure curves. Gamma factors (GFs) were evaluated at 0.3 m and 1.0 m from the centre of the radioactive source and compared with internationally recognised literature values. Self-absorption factors (SFs) were derived by comparing phantom and point source curves across clinical distances. Measured GFs showed excellent agreement with published data and internationally recognised standards, differing by only 2% for F-18 at both 30 cm (1.84 μSv/h/MBq) and 100 cm (0.161 μSv/h/MBq), and by 1% for I-131 at 30 cm (0.721 μSv/h/MBq). The average SF for F-18 (0.71 ± 0.04), representing patient self-attenuation for an unknown body orientation, was consistent with published Monte Carlo estimates. Differences reported in the literature were attributed to methodological variations, including the use of computational modelling rather than direct experimental measurements, along with variations in phantom design, source geometry, and detector configuration. This work presents an experimentally measured dataset with corresponding dose rate models for NM applications. The results contribute additional empirical evidence that may be used alongside established radiation protection methodologies to support assessments of shielding, procedure scheduling, and occupational and public radiation risk, potentially reducing reliance on overly conservative assumptions when evaluating dose rates at clinical distances.

  • Open Access

    From Point Sources to Phantoms: Refining Dose Rate Models in Nuclear Medicine with Tc-99m, F-18, I-131 and Lu- 177

    by Joshua Ierace, Pejman Rowshanfarzad, Christine Sinnott, Rikki Nezich, Paul Brayshaw, Mario Djukelic

    Healthcare workers in nuclear medicine (NM) are often exposed to external radiation from patients who have been administered radiopharmaceuticals, particularly during procedures requiring close contact. Traditional dose rate estimates commonly assume patients to be unattenuated point sources and apply inverse square law calculations, which tend to overestimate exposures at clinical distances. This study presents an experimental approach to quantify dose rates more accurately from NM patients using point, line, and phantom source models of Tc-99m, F-18, I-131, and Lu-177.Measurements were performed with calibrated ionisation chambers under controlled low-background conditions. Radioisotope activities were selected to achieve detectable dose rates while minimising staff exposure. Point and line source measurements provided baseline external exposure data across 10–100 cm. Phantom models, including a homogeneous water-filled NEMA body phantom and a PMMA neck phantom, were used to replicate clinical patient geometries. Dose rates were decay-corrected, normalised to activity, and fitted with biexponential models to generate exposure curves. Gamma factors (GFs) were evaluated at 0.3 m and 1.0 m and compared with internationally recognised literature values. Self-absorption factors (SFs) were derived by comparing phantom and point source curves across clinical distances.Results showed that measured GFs agreed within 10% of published values for most isotopes, with discrepancies largely explained by methodological differences. SFs varied by isotope and geometry, with lateral phantom orientations exhibiting the highest attenuation. For F-18 and Tc-99m, phantom-derived SFs were consistent with patient data and Monte Carlo simulations. I-131 neck phantom results demonstrated orientation-dependent shielding, with posterior measurements showing the greatest attenuation.This work provides a validated dataset and modelling framework for dose rate estimation in NM. These results support evidence-based clinical decisions regarding shielding, procedure scheduling, and occupational safety, reducing reliance on overly conservative assumptions and enabling accurate, practical radiation protection strategies.


  • Open Access

    Development and characterisation of a high-sensitivity X-ray CT polymer gel dosimeter

    by Jonathon Lexor Lumley, Pejman Rowshanfarzad, Mounir Ibrahim, Mario Djukelic, David J. Henry

    Polymer gel dosimeters have shown potential for clinical 3D dosimetry; however, their use has been limited due to low sensitivity and reliance on scarcely available magnetic resonance imaging. This study aimed to optimise a PASSAG (Poly AMPS Sodium Salt And Gelatin) polymer gel dosimeter for X-ray computed tomography, to enhance its clinical feasibility. The total monomer concentration was increased to improve sensitivity, and different cosolvents were tested to enhance the limited solubility of N, N’-methylenebisacrylamide, the crosslinker. n-propanol was identified as the optimal cosolvent, allowing for an 18.3% monomer concentration, 30% crosslinker to total comonomer mass gel, at a 3:7 cosolvent-to-water ratio. The optimised formulation, PASSAG-N (PASSAG– n-propanol), consisted of 54.4% w/w deionised water, 23.3% n-propanol, 12.8% 2-acrylamido-2-methylpropane sulfonic acid sodium salt, 5.5% N, N’-methylenebisacrylamide, 4.0% gelatin, and 0.089% (4.65mM) tetrakis (hydroxymethyl)phosphonium chloride. The dosimeter was irradiated within a standard timeframe to assess its sensitivity, and theoretical calculations confirmed its equivalence to water, soft tissue, brain, and muscle. Compared to a cosolvent-free formulation, PASSAG-N exhibited a 250% increase in Hounsfield unit (HU) change, demonstrating enhanced sensitivity. The optimised gel showed a linear response over a 1–12 Gy dose range, with an average sensitivity of 1.072 ± 0.041 HU Gy⁻¹ and a dose resolution ≤ 0.31 Gy, making it a promising alternative for clinical X-ray computed tomography-based dosimetry. This study highlights the potential of PASSAG-N as a highly sensitive and potentially practical polymer gel dosimeter for clinical applications.


  • Cone beam CT (CBCT) in radiotherapy: Assessment of doses using a pragmatic setup in an international setting

    by Mario Djukelic, Colin John Martin, Abdullah Abuhaimed, Tomas Kron, Sebastien Gros, Tim Wood, Piotr Pankowski, Ngie Min Ung, Jenia Vassileva, María Cristina Plazas, et al.


  • An international survey of imaging practices in radiotherapy

    by C.J. Martin, T. Kron, J. Vassileva, T.J. Wood, C. Joyce, N.M. Ung, W. Small, S. Gros, Y. Roussakis, M.C. Plazas, et al.


  • Mammography diagnostic reference levels in Western Australia

    by Cameron Storm, Alicia Harvey, Mario Djukelic

    Mammography dose data has been collected from Western Australian units to establish Diagnostic Reference Levels for the state. Reference levels have been determined for a variety of phantom thicknesses for both full field digital mammography units and digital breast tomosynthesis units. Levels for the American College of Radiology (ACR) Phantom have been established as 1.3 mGy and 1.5 mGy mean glandular dose for full field digital mammography and digital breast tomosynthesis respectively. 2 cm PMMA was 0.9 mGy and 1.0 mGy and 6 cm PMMA had values of 2.0 mGy and 2.3 mGy. This data can be utilised to help establish national reference levels in the future.


  • Open Access

    Evaluation of a mobile C‐arm cone‐beam CT in interstitial high‐dose‐rate prostate brachytherapy treatment planning

    by Mario Djukelic, David Waterhouse, Ryan Toh, Hendrick Tan, Pejman Rowshanfarzad, David Joseph, Martin A. Ebert

    Introduction: The aim of this study was to evaluate the suitability of using cone‐beam computed tomography (CBCT) obtained with a mobile C‐arm X‐ray fluoroscopy unit as a single modality for planning of high‐dose‐rate (HDR) prostate brachytherapy treatments.Methods: The feasibility of using CBCT images obtained using a Siemens Arcadis Orbic 3D mobile C‐arm was evaluated. A retrospective clinical study was undertaken of six participants undergoing HDR prostate brachytherapy. Plans generated using images from a Toshiba Aquilion One LB CT were compared with those generated using CBCT images. After rigid spatial registration, the plans were compared based on various parameters such as dose‐volume histograms, overlap quantities and metrics, and dose constraints.Results: Provided they were within the limited field of view, the brachytherapy catheters and fiducial markers were clearly visible in the CBCT images and thus, localisable and identifiable in the treatment planning process. The Siemens CBCT underestimated CT numbers leading to poorer tissue contrast which exacerbated the difficulties in delineation of the target tumour and the surrounding organs at risk. Between CT‐ and CBCT‐based plans, the mean difference of CTV‐D90 was 1.58 Gy, CTV‐V100 was 12.13%, rectum‐V80 was 0.06% and urethra‐V120 was −0.70%.Conclusion: It was not feasible to solely utilise the Siemens Arcadis Orbic 3D for HDR prostate brachytherapy treatment planning due to suboptimal organ delineation. However, the methods in this study could be used to evaluate other mobile CBCT imaging devices for feasibility in HDR brachytherapy treatment planning since the results indicated that it may not be necessary to have standard quality CT images for treatment planning.


  • Influence of neighboring adherent cells on laminar flow induced shear stress in vitro—A systematic study

    by Mario Djukelic, Achim Wixforth, Christoph Westerhausen

    Cells experience forces if subjected to laminar flow. These forces, mostly of shear force character, are strongly dependent not only on the applied flow field itself but also on hydrodynamic effects originating from neighboring cells. This particularly becomes important for the interpretation of data from in vitro experiments in flow chambers without confluent cell layers. By employing numerical Finite Element Method simulations of such assemblies of deformable objects under shear flow, we investigate the occurring stress within elastic adherent cells and the influence of neighboring cells on these quantities. For this, we simulate single and multiple adherent cells of different shapes fixed on a solid substrate under laminar flow parallel to the substrate for different velocities. We determine the local stress within the cells close to the cell-substrate-interface and the overall stress of the cells by surface integration over the cell surface. Comparing each measurand in the case of a multiple cell situation with the corresponding one of single cells under identical conditions, we introduce a dimensionless influence factor. The systematic variation of the distance and angle between cells, where the latter is with respect to the flow direction, flow velocity, Young's modulus, cell shape, and cell number, enables us to describe the actual influence on a cell. Overall, we here demonstrate that the cell density is a crucial parameter for all studies on flow induced experiments on adherent cells in vitro.