Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ivo Schulthess has a total of 91 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A dump leakage calorimeter to measure the flux of high-energy electrons and photons

    by Antonios Athanassiadis, Ties Behnke, Jonas Björklund Svensson, Oleksandr Borysov, Maryna Borysova, Lewis Boulton, Sarawit Chindaratchakul, Beate Heinemann, Louis Helary, Ruth Jacobs, et al.

    We developed a novel apparatus based on a lead-glass calorimeter that can measure the flux of high-energy electrons or photons. Our detector uses the electromagnetic shower leakage from the beam dump, where the particles are disposed of at the beamline's end. A prototype of such a calorimeter was set up at the FLASHForward experiment at DESY. We show that it can measure the electron bunch charge with a typical precision on the order of 10% and an accuracy at the few-percent level. Additionally, it is capable of determining the beam's position with a precision on the order of tens of micrometers. Finally, we demonstrate applicability to high-energy photons.

  • Open Access

    From LUXE to future colliders: probing strong-field QED and beyond

    by Ivo Schulthess

    Strong-field quantum electrodynamics offers a unique window into nonperturbative phenomena such as nonlinear Breit–Wheeler pair production, in which electron–positron pairs are created from the vacuum in the presence of intense electromagnetic fields. The LUXE experiment at DESY is designed to probe this regime using collisions between a high-intensity laser and the 16.5 GeV electron beam of the European XFEL. Future accelerator infrastructures, such as linear colliders, could extend these studies to even higher intensity and energy scales. Additionally, high-energy photons produced in such interactions can be used in beam-dump experiments to search for new physics.

  • Open Access

    Primer of Strong-Field Quantum Electrodynamics for Experimentalists

    by Annabel Kropf, Ivo Schulthess

    This review serves as a conceptual and practical introduction to strong-field quantum electrodynamics (SFQED), written from the standpoint of experimental physicists. Rather than providing a comprehensive theoretical review, the paper focuses on the core ideas, terminology, and challenges in SFQED that are most relevant to experimental design and interpretation. The review serves as a first point of contact with the subject, bridging the gap between foundational theory and hands-on experimental investigations, and complementing more formal literature in the field.


  • Open Access

    From LUXE to Future Colliders: Probing Strong-Field QED and Beyond

    by Ivo Schulthess

    Strong-field quantum electrodynamics offers a unique window into non-perturbative phenomena such as vacuum pair production, in which electron--positron pairs are created from the vacuum in the presence of intense electromagnetic fields. The LUXE experiment at DESY is designed to probe this regime using collisions between a high-intensity laser and the 16.5 GeV electron beam of the European XFEL. Future accelerator infrastructures, such as linear colliders, could extend these studies to even higher intensity and energy scales. Additionally, high-energy photons produced in such interactions can be used in beam-dump experiments to search for new physics.

  • Open Access

    A dump leakage calorimeter to measure the flux of high-energy electrons and photons

    by Antonios Athanassiadis, Ties Behnke, Jonas Björklund Svensson, Oleksandr Borysov, Maryna Borysova, Lewis Boulton, Sarawit Chindaratchakul, Beate Heinemann, Louis Helary, Ruth Jacobs, et al.

    We developed a novel apparatus based on a lead glass calorimeter that can measure the flux of high-energy electrons or photons. Our detector uses the electromagnetic shower leakage from the beam dump, where the particles are disposed of at the beamline's end. A prototype of such a calorimeter was set up at the FLASHForward experiment at DESY. We show that it can measure the electron bunch charge with precision and accuracy at the 10% and 3% level, respectively. Additionally, it is capable of determining the beam's position with a precision on the order of tens of micrometers. Finally, we show the applicability to the measurement of high-energy photons.

  • Open Access

    A high-flux electron detector system to measure non-linear Compton scattering at LUXE

    by Antonios Athanassiadis, Robert Ariniello, Louis Helary, Luke Hendriks, Ruth Jacobs, Alexander Knetsch, Jenny List, Sebastian Meuren, Gudrid Moortgat-Pick, Ivan Rajkovic, et al.


  • Open Access

    A High-Flux Electron Detector System to Measure Non-linear Compton Scattering at LUXE

    by Antonios Athanassiadis, Robert Ariniello, Louis Helary, Luke Hendriks, Ruth Jacobs, Alexander Knetsch, Jenny List, Sebastian Meuren, Gudrid Moortgat-Pick, Ivan Rajkovic, et al.

    Recently, advancements in high-intensity laser technology have enabled the exploration of non-perturbative Quantum Electrodynamics (QED) in strong-field regimes. Notable aspects include non-linear Compton scattering and Breit-Wheeler pair production, observable when colliding high-intensity laser pulses and relativistic electron beams. The LUXE experiment at DESY and the E-320 experiment at SLAC aim to study these phenomena by measuring the created high-flux Compton electrons and photons. We propose a novel detector system featuring a segmented gas-filled Cherenkov detector with a scintillator screen and camera setup, designed to efficiently detect high-flux Compton electrons. Preliminary results from E-320 measurement campaigns demonstrate methods for reconstructing electron energy spectra, aiming to reveal crucial features of non-perturbative QED.

  • Open Access

    New Physics Search with the Optical Dump Concept at Future Colliders

    by Ivo Schulthess, Federico Meloni

    Beam-dump experiments offer an opportunity to search for new physics beyond the Standard Model of particle physics. In this work, we explore the use of a high-energy photon beam on a fixed target. Such photons can be produced via Compton backscattering when colliding high-energy electrons with a high-intensity laser pulse, such as in setups of strong-field quantum electrodynamics experiments. We present various options for implementing such photon sources at future facilities and discuss how the photons can be used to search for axion-like particles. We compare the projected sensitivities of the proposed options with existing constraints, projections from current experiments, and direct searches at future colliders.

  • Frequency-offset separated oscillatory fields technique applied to neutrons

    by Anastasio Fratangelo, Philipp Heil, Christine Klauser, Gjon Markaj, Marc Persoz, Ciro Pistillo, Ivo Schulthess, Jacob Thorne, Florian M. Piegsa

    The novel technique of frequency-offset separated oscillatory fields (FOSOF) was originally proposed as a modification to Ramsey's method of separated oscillatory fields. It has recently been employed in precision measurements with atomic beams since it allows for an alternative approach to determine absolute resonance frequencies. We present results from a systematic investigation of the FOSOF technique adapted to a beam of cold neutrons.


  • Compact 20-pass thin-disk multipass amplifier stable against thermal lensing effects and delivering 330 mJ pulses with M2 < 1.17

    by Manuel Zeyen, Lukas Affolter, Marwan Abdou Ahmed, Thomas Graf, Oguzhan Kara, Klaus Kirch, Miroslaw Marszalek, François Nez, Ahmed Ouf, Randolf Pohl, et al.

    We report on an Yb:YAG thin-disk multipass amplifier delivering 100 ns long pulses at a central wavelength of 1030 nm with an energy of 330 mJ at a repetition rate of 100 Hz. The beam quality factor at the maximum energy was measured to be M2 < 1.17. The small signal gain is 21.7, and the gain at 330 mJ was measured to be 6.9. The 20-pass amplifier is designed as a concatenation of stable resonator segments in which the beam is alternately Fourier transformed and relay-imaged back to the disk by a 4f-imaging optical scheme stage. The Fourier transform propagation makes the output beam robust against spherical phase front distortions, while the 4f-stage is used to compensate the thermal lens of the thin-disk and to reduce the footprint of the amplifier.