Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Philip James Basford has a total of 77 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Three-dimensional reconstruction of high latitude bamboo coral via X-ray microfocus Computed Tomography

    by Thomas J. Williams, Philip J. Basford, Orestis L. Katsamenis, Martin Solan, Gavin L. Foster, Christopher Standish, Jasmin A. Godbold, Philippe Archambault

    The skeletons of long-lived bamboo coral (Family Keratoisididae) are promising archives for deep-water palaeoceanographic reconstructions as they can record environmental variation at sub-decadal resolution in locations where in-situ measurements lack temporal coverage. Yet, detailed three dimensional (3D) characterisations of bamboo coral skeletal architecture are not routinely available and non-destructive investigations into microscale variations in calcification are rare. Here, we provide high-resolution micro-focus computed tomography (µCT) data of skeletal density for two species of bamboo coral (Acanella arbuscula: 5 specimens, voxel size, 15 µm (central branch scans) and 50 µm (complete structure scan); Keratoisis sp.: 4 specimens, voxel size, 15 µm) collected from the Labrador Sea and Baffin Bay deep-water basins, Eastern Canadian Arctic. These data provide reference models useful for developing methods to assess structural integrity and other fine-scale complexities in many biological, geological, and industrial systems. This will be of wider value to those investigating structural composition, arrangement and/or composition of complex architecture within the fields and subdisciplines of biology, ecology, medicine, environmental geology, and structural engineering.


  • Open Access

    A high-throughput 3D X-ray histology facility for biomedical research and preclinical applications

    by Orestis L. Katsamenis, Philip J. Basford, Stephanie K. Robinson, Richard P. Boardman, Elena Konstantinopoulou, Peter M. Lackie, Anton Page, J. Arjuna Ratnayaka, Patricia M. Goggin, Gareth J. Thomas, et al.

    Background The University of Southampton, in collaboration with the University Hospital Southampton (UHS) NHS Foundation Trust and industrial partners, has been at the forefront of developing three-dimensional (3D) imaging workflows using X-ray microfocus computed tomography (μCT) -based technology. This article presents the outcomes of these endeavours and highlights the distinctive characteristics of a μCT facility tailored explicitly for 3D X-ray Histology, with a primary focus on applications in biomedical research and preclinical and clinical studies. Methods The UHS houses a unique 3D X-ray Histology (XRH) facility, offering a range of services to national and international clients. The facility employs specialised μCT equipment explicitly designed for histology applications, allowing whole-block XRH imaging of formalin-fixed and paraffin-embedded tissue specimens. It also enables correlative imaging by combining μCT imaging with other microscopy techniques, such as immunohistochemistry (IHC) and serial block-face scanning electron microscopy, as well as data visualisation, image quantification, and bespoke analysis. Results Over the past seven years, the XRH facility has successfully completed over 120 projects in collaboration with researchers from 60 affiliations, resulting in numerous published manuscripts and conference proceedings. The facility has streamlined the μCT imaging process, improving productivity and enabling efficient acquisition of 3D datasets. Discussion & Conclusions The 3D X-ray Histology (XRH) facility at UHS is a pioneering platform in the field of histology and biomedical imaging. To the best of our knowledge, it stands out as the world's first dedicated XRH facility, encompassing every aspect of the imaging process, from user support to data generation, analysis, training, archiving, and metadata generation. This article serves as a comprehensive guide for establishing similar XRH facilities, covering key aspects of facility setup and operation. Researchers and institutions interested in developing state-of-the-art histology and imaging facilities can utilise this resource to explore new frontiers in their research and discoveries.


  • Open Access

    Laboratory Comparison of Low-Cost Particulate Matter Sensors to Measure Transient Events of Pollution—Part B—Particle Number Concentrations

    by Florentin Michel Jacques Bulot, Hugo Savill Russell, Mohsen Rezaei, Matthew Stanley Johnson, Steven James Ossont, Andrew Kevin Richard Morris, Philip James Basford, Natasha Hazel Celeste Easton, Hazel Louise Mitchell, Gavin Lee Foster, et al.

    Low-cost Particulate Matter (PM) sensors offer an excellent opportunity to improve our knowledge about this type of pollution. Their size and cost, which support multi-node network deployment, along with their temporal resolution, enable them to report fine spatio-temporal resolution for a given area. These sensors have known issues across performance metrics. Generally, the literature focuses on the PM mass concentration reported by these sensors, but some models of sensors also report Particle Number Concentrations (PNCs) segregated into different PM size ranges. In this study, eight units each of Alphasense OPC-R1, Plantower PMS5003 and Sensirion SPS30 have been exposed, under controlled conditions, to short-lived peaks of PM generated using two different combustion sources of PM, exposing the sensors’ to different particle size distributions to quantify and better understand the low-cost sensors performance across a range of relevant environmental ranges. The PNCs reported by the sensors were analysed to characterise sensor-reported particle size distribution, to determine whether sensor-reported PNCs can follow the transient variations of PM observed by the reference instruments and to determine the relative impact of different variables on the performances of the sensors. This study shows that the Alphasense OPC-R1 reported at least five size ranges independently from each other, that the Sensirion SPS30 reported two size ranges independently from each other and that all the size ranges reported by the Plantower PMS5003 were not independent of each other. It demonstrates that all sensors tested here could track the fine temporal variation of PNCs, that the Alphasense OPC-R1 could closely follow the variations of size distribution between the two sources of PM, and it shows that particle size distribution and composition are more impactful on sensor measurements than relative humidity.


  • Open Access

    Characterisation and calibration of low-cost PM sensors at high temporal resolution to reference-grade performance

    by Florentin M.J. Bulot, Steven J. Ossont, Andrew K.R. Morris, Philip J. Basford, Natasha H.C. Easton, Hazel L. Mitchell, Gavin L. Foster, Simon J. Cox, Matthew Loxham


  • Open Access

    Laboratory Comparison of Low-Cost Particulate Matter Sensors to Measure Transient Events of Pollution - Part B - Particle Number Concentrations

    by Florentin Michel Jacques Bulot, Hugo Savill Russell, Mohsen Rezaei, Matthew Stanley Johnson, Steven James Ossont, Andrew Kevin Richard Morris, Philip James Basford, Natasha Hazel Celeste Easton, Hazel Louise Mitchell, Gavin Lee Foster, et al.

    Low-cost particulate matter (PM) sensors offer an excellent opportunity to improve our knowledge about this type of pollution. Their size and their cost, which support multi-node network deployment, along with their temporal resolution, enable them to report fine spatio-temporal resolution for a given area. These sensors have known issues across performance metrics. Generally, the literature focuses on the PM mass concentration reported by these sensors but some models of sensors also report particle number concentrations (PNC) segregated into different PM size bins. In this study, 8 units of each Alphasense OPC-R1, Plantower PMS5003 and Sensirion SPS30 have been exposed, under controlled conditions, to short-lived peaks of PM generated using two different combustion sources of PM, exposing the sensors to different particle size distributions to quantify and better understand the low cost sensors performance across a range of relevant environmental ranges. The PNC reported by the sensors were analysed. This study showed that there is added value in directly using the PNC reported by the sensors instead of the mass concentrations, which could aid the efforts to calibrate these sensors to a known accuracy. It demonstrated that all sensors tested here could track the fine temporal variation of PNC, that the Alphasense OPC-R1 could closely follow the variations of size distribution between the two sources of PM, and it showed that particle size distribution and composition are more impactful on the sensors measurement than relative humidity.


  • Open Access

    The Reconstruction of Human Fingerprints From High-Resolution Computed Tomography Data: Feasibility Study and Associated Ethical Issues

    by Orestis L Katsamenis, Charles B Burson-Thomas, Philip J Basford, J Brian Pickering, Martin Browne


  • Open Access

    Laboratory Comparison of Low-Cost Particulate Matter Sensors to Measure Transient Events of Pollution

    by Florentin Michel Jacques Bulot, Hugo Savill Russell, Mohsen Rezaei, Matthew Stanley Johnson, Steven James Johnston Ossont, Andrew Kevin Richard Morris, Philip James Basford, Natasha Hazel Celeste Easton, Gavin Lee Foster, Matthew Loxham, et al.

    Airborne particulate matter (PM) exposure has been identified as a key environmental risk factor, associated especially with diseases of the respiratory and cardiovascular system and with almost 9 million premature deaths per year. Low-cost optical sensors for PM measurement are desirable for monitoring exposure closer to the personal level and particularly suited for developing spatiotemporally dense city sensor networks. However, questions remain over the accuracy and reliability of the data they produce, particularly regarding the influence of environmental parameters such as humidity and temperature, and with varying PM sources and concentration profiles. In this study, eight units each of five different models of commercially available low-cost optical PM sensors (40 individual sensors in total) were tested under controlled laboratory conditions, against higher-grade instruments for: lower limit of detection, response time, responses to sharp pollution spikes lasting <1 min , and the impact of differing humidity and PM source. All sensors detected the spikes generated with a varied range of performances depending on the model and presenting different sensitivity mainly to sources of pollution and to size distributions with a lesser impact of humidity. The sensitivity to particle size distribution indicates that the sensors may provide additional information to PM mass concentrations. It is concluded that improved performance in field monitoring campaigns, including tracking sources of pollution, could be achieved by using a combination of some of the different models to take advantage of the additional information made available by their differential response.


  • Open Access

    LoRaWAN for Smart City IoT Deployments: A Long Term Evaluation

    by Philip J. Basford, Florentin M. J. Bulot, Mihaela Apetroaie-Cristea, Simon J. Cox, Steven J. Ossont

    LoRaWAN is a Low-Power Wide Area Network (LPWAN) technology designed for Internet of Things (IoT) deployments; this paper presents experiences from deploying a city-scale LoRaWAN network across Southampton, UK. This network was deployed to support an installation of air quality monitors and to explore the capabilities of LoRaWAN. This deployment uses a mixture of commercial off-the-shelf gateways and custom gateways. These gateway locations were chosen based on network access, site permission and accessibility, and are not necessarily the best locations theoretically. Over 135,000 messages have been transmitted by the twenty devices analysed. Over the course of the complete deployment, 72.4 % of the messages were successfully received by the data server. Of the messages that were received, 99% were received within 10 s of transmission. We conclude that LoRaWAN is an applicable communication technology for city-scale air quality monitoring and other smart city applications.


  • Open Access

    Performance analysis of single board computer clusters

    by Philip J. Basford, Steven J. Johnston, Colin S. Perkins, Tony Garnock-Jones, Fung Po Tso, Dimitrios Pezaros, Robert D. Mullins, Eiko Yoneki, Jeremy Singer, Simon J. Cox


  • Open Access

    Surface melt‐driven seasonal behaviour (englacial and subglacial) from a soft‐bedded temperate glacier recorded by in situ wireless probes

    by Jane K. Hart, Kirk Martinez, Philip J. Basford, Alexander I. Clayton, Graeme M. Bragg, Tyler Ward, David S. Young

    We investigate the spatial and temporal englacial and subglacial processes associated with a temperate glacier resting on a deformable bed using the unique Glacsweb wireless in situ probes (embedded in the ice and the till) combined with other techniques [including ground penetrating radar (GPR) and borehole analysis]. During the melt season (spring, summer and autumn), high surface melt leads to high water pressures in the englacial and subglacial environment. Winter is characterized by no surface melting on most days (‘base’) apart from a series of positive degree days. Once winter begins, a diurnal water pressure cycle is established in the ice and at the ice/sediment interface, with direct meltwater inputs from the positive degree days and a secondary slower englacial pathway with a five day lag. This direct surface melt also drives water pressure changes in the till. Till deformation occurred throughout the year, with the winter rate approximately 60% that of the melt season. We were able to show the bed comprised patches of till with different strengths, and were able to estimate their size, relative percentage and temporal stability. We show that the melt season is characterized by a high pressure distributed system, and winter by a low pressure channelized system. We contrast this with studies from Greenland (overlying rigid bedrock), where the opposite was found. We argue our results are typical of soft bedded glaciers with low englacial water content, and suggest this type of glacier can rapidly respond to surface‐driven melt. Based on theoretical and field results we suggest that the subglacial hydrology comprises a melt season distributed system dominated by wide anastomosing broad flat channels and thin water sheets, which may become more channelized in winter, and more responsive to changes in meltwater inputs. © 2019 The Authors. Earth Surface Processes and Landforms published by John Wiley & Sons Ltd.