Syugo Hayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Syugo Hayashi has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Masashi Kamogawa
Natural Disaster Research Section Global Center for Asian and Regional Research University of Shizuoka Shizuoka Japan
6 shared publications - Yuuki Wada
Department of Earth and Planetary Sciences, Faculty of Science, Hokkaido University, Sapporo, Hokkaido, Japan
5 shared publications - Hironobu Fujiwara
Laboratory for Environmental Research at Mount Fuji, NPO Mount Fuji Research Station, Tokyo 169-0072, Japan
4 shared publications - Hiroshi Okochi
Graduate School of Creative Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku, Tokyo 169-8555, Japan
3 shared publications Tomoo Ushio
Department of Electrical, Electronic, and Infocommunications Engineering, The University of Osaka, Osaka, Japan
3 shared publications- Tomoyuki Suzuki
Global Center for Asian and Regional Research, University of Shizuoka, Shizuoka 420-0839, Japan
3 shared publications
Latest Publications
- Open Access
- 26 October 2026
- Published by MDPI AG in Preprints.org
Initial Evaluation of the Fuji-Centered Lightning Monitoring (FULMO) Network Using Boltek LRX-1 Receivers in Central Japan
We constructed a two-dimensional lightning location network, FULMO (Fuji-centered Lightning Monitoring), from Boltek LRX-1 receivers around Mt. Fuji in central Japan. These receivers observe lightning electromagnetic waves mainly in the very low frequency and low frequency (VLF/LF) band, and locations are obtained by time-of-arrival. Performance was evaluated against the Japanese Lightning Detection Network (JLDN). With six operational stations, the relative detection efficiency was 52.6% for JLDN cloud-to-ground (CG) strokes and 22.6% for intracloud (IC) discharges; the median location difference for CG strokes was 1.60 km. The difference depended strongly on station geometry: 0.85 km where the largest angular gap between azimuthally adjacent stations, as seen from the discharge, was <180°, and 6.53 km where that gap was ≥180°, the smaller value corre-sponding to discharges inside the group. Five features of the LRX-1 specification limit research use: the catalog carries a systematic timing offset of −0.99898 s requiring correction before catalog matching; it provides no quality index for the azimuthal distribution of contributing stations; it records only four station identifiers per location although more can contribute, leaving that distri-bution unknown; it does not discriminate CG from IC discharges; and it gives no polarity. We rec-ommend that the manufacturer address these points.
- 26 October 2026
- Published by MDPI AG in Preprints.org
Open AccessInitial Evaluation of the Fuji-Centered Lightning Monitoring (FULMO) Network Using Boltek LRX-1 Receivers in Central Japan
We constructed a two-dimensional lightning location network, FULMO (Fuji-centered Lightning Monitoring), from Boltek LRX-1 receivers around Mt. Fuji in central Japan. These receivers observe lightning electromagnetic waves mainly in the very low frequency and low frequency (VLF/LF) band, and locations are obtained by time-of-arrival. Performance was evaluated against the Japanese Lightning Detection Network (JLDN). With six operational stations, the relative detection efficiency was 52.6% for JLDN cloud-to-ground (CG) strokes and 22.6% for intracloud (IC) discharges; the median location difference for CG strokes was 1.60 km. The difference depended strongly on station geometry: 0.85 km where the largest angular gap between azimuthally adjacent stations, as seen from the discharge, was <180°, and 6.53 km where that gap was ≥180°, the smaller value corre-sponding to discharges inside the group. Five features of the LRX-1 specification limit research use: the catalog carries a systematic timing offset of −0.99898 s requiring correction before catalog matching; it provides no quality index for the azimuthal distribution of contributing stations; it records only four station identifiers per location although more can contribute, leaving that distri-bution unknown; it does not discriminate CG from IC discharges; and it gives no polarity. We rec-ommend that the manufacturer address these points.
- 30 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 64 (01962892) , 1-19
Improving GSMaP Precipitation Estimates Using a Modified Kalman Filter With Lightning Flash Rate
Precipitation drives various Earth’s processes and is linked to hazards like flash floods and drought, making timely and accurate monitoring of precipitation crucial for disaster mitigation. The Global Satellite Mapping of Precipitation (GSMaP) provides high-resolution rainfall data by combining microwave radiometer (MWR) and infrared (IR) retrievals. Since MWR retrievals are limited and only available every three hours, GSMaP’s near-real-time (NRT) product propagates MWR measurements forward in time and refines rainfall rates based on IR data through a Kalman filter. GSMaP estimates rain at high spatiotemporal resolutions, but is still susceptible to errors due to IR only seeing the cloud top instead of detecting actual precipitation. This study enhances the precipitation estimates of GSMaP NRT by integrating lightning as additional information in the Kalman filter, generating a new product called GSMaP NRTL. The approach is to use specific measurement models in the Kalman filter based on the relationship of rainfall with IR brightness temperature and lightning, classified into two thunderstorm types. Type I mostly incorporates mature stage thunderstorms, while Type II includes initiating and dissipating thunderstorms. Validation results show that NRTL improves on the performance of NRT, particularly reducing errors and biases while increasing the correlation and rainfall detection. However, underestimation persists in moderate to heavy rain (> 10 mmh -1). Kling-Gupta Efficiency (KGE) scores show that NRTL achieves better performance at finer resolutions than NRT usually does, even after aggregation. KGE also shows that NRTL performs best in Type I thunderstorms, especially over land, while improvements in Type II indicate better representation of usually underestimated rainfall in this type.
- 30 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 64 (01962892) , 1-19
Improving GSMaP Precipitation Estimates Using a Modified Kalman Filter With Lightning Flash Rate
Precipitation drives various Earth’s processes and is linked to hazards like flash floods and drought, making timely and accurate monitoring of precipitation crucial for disaster mitigation. The Global Satellite Mapping of Precipitation (GSMaP) provides high-resolution rainfall data by combining microwave radiometer (MWR) and infrared (IR) retrievals. Since MWR retrievals are limited and only available every three hours, GSMaP’s near-real-time (NRT) product propagates MWR measurements forward in time and refines rainfall rates based on IR data through a Kalman filter. GSMaP estimates rain at high spatiotemporal resolutions, but is still susceptible to errors due to IR only seeing the cloud top instead of detecting actual precipitation. This study enhances the precipitation estimates of GSMaP NRT by integrating lightning as additional information in the Kalman filter, generating a new product called GSMaP NRTL. The approach is to use specific measurement models in the Kalman filter based on the relationship of rainfall with IR brightness temperature and lightning, classified into two thunderstorm types. Type I mostly incorporates mature stage thunderstorms, while Type II includes initiating and dissipating thunderstorms. Validation results show that NRTL improves on the performance of NRT, particularly reducing errors and biases while increasing the correlation and rainfall detection. However, underestimation persists in moderate to heavy rain (> 10 mmh -1). Kling-Gupta Efficiency (KGE) scores show that NRTL achieves better performance at finer resolutions than NRT usually does, even after aggregation. KGE also shows that NRTL performs best in Type I thunderstorms, especially over land, while improvements in Type II indicate better representation of usually underestimated rainfall in this type.
- Open Access
- 1 January 2025
- Published by Springer Nature in SOLA
- Vol. 21A (Special_Ed) , 1-9
An Object-Based Approach for Quantitative Verification of Quasi-Stationary Band-Shaped Precipitation Systems, “Senjo-Kousuitai,” Forecasts
- 1 January 2025
- Published by Springer Nature in SOLA
- Vol. 21A (Special_Ed) , 1-9
Open AccessAn Object-Based Approach for Quantitative Verification of Quasi-Stationary Band-Shaped Precipitation Systems, “Senjo-Kousuitai,” Forecasts
- Open Access
- 2 October 2024
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 129 (19)
Observation of Electrical Alignment Signatures in an Isolated Thunderstorm by Dual‐Polarized Phased Array Weather Radar and the Relationship With Intracloud Lightning Flash Rate
The electrical alignment signatures of ice crystals in the middle and upper parts of a thunderstorm have a physical connection with the strong electric fields within the cloud. By taking advantage of the high spatio‐temporal resolution of an X‐band dual‐polarized multiparameter phased array radar, this paper employs negative KDP signatures to investigate the variation of electric fields in an isolated thunderstorm within its evolution, and the relationship between the negative KDP signatures and intracloud (IC) lightning activity. The results show that the radar‐inferred strong electric fields distributed in a region of about 8.5–10 km during the developing stage, then extended from about 10 km to the cloud top during the mature stage, with an increasing IC lightning flash rate before the end of the mature stage. Subsequently, the electric fields weakened associated with a large amount of IC lightning discharges. The qualitative analysis results indicate that the evolution of the radar‐inferred electric fields associated with the upper charge regions is consistent with the electrification process in the isolated thunderstorm, inferred by the IC lighting activity. In addition, there is a tendency for the increased IC lightning rate as the decrease in average composite KDP in the middle and upper layers of the thunderstorm, with a time lag of about 5.5 min between the minimum average composite KDP and the peak IC lightning rate, while a good correlation between the negative KDP volume and the IC lightning flash rate at a lag of approximately 9 min.
- 2 October 2024
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 129 (19)
Open AccessObservation of Electrical Alignment Signatures in an Isolated Thunderstorm by Dual‐Polarized Phased Array Weather Radar and the Relationship With Intracloud Lightning Flash Rate
The electrical alignment signatures of ice crystals in the middle and upper parts of a thunderstorm have a physical connection with the strong electric fields within the cloud. By taking advantage of the high spatio‐temporal resolution of an X‐band dual‐polarized multiparameter phased array radar, this paper employs negative KDP signatures to investigate the variation of electric fields in an isolated thunderstorm within its evolution, and the relationship between the negative KDP signatures and intracloud (IC) lightning activity. The results show that the radar‐inferred strong electric fields distributed in a region of about 8.5–10 km during the developing stage, then extended from about 10 km to the cloud top during the mature stage, with an increasing IC lightning flash rate before the end of the mature stage. Subsequently, the electric fields weakened associated with a large amount of IC lightning discharges. The qualitative analysis results indicate that the evolution of the radar‐inferred electric fields associated with the upper charge regions is consistent with the electrification process in the isolated thunderstorm, inferred by the IC lighting activity. In addition, there is a tendency for the increased IC lightning rate as the decrease in average composite KDP in the middle and upper layers of the thunderstorm, with a time lag of about 5.5 min between the minimum average composite KDP and the peak IC lightning rate, while a good correlation between the negative KDP volume and the IC lightning flash rate at a lag of approximately 9 min.
- Open Access
- 30 March 2024
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 129 (7)
Electrical Alignment Signatures of Ice Particles Before Intracloud Lightning Activity Detected by Dual‐Polarized Phased Array Weather Radar
The cloud electrification process has great significance in understanding the microphysical properties, electrical characteristics, and evolution of thunderstorms. This study employs an X‐band dual‐polarized multiparameter phased array weather radar (MP‐PAWR) to observe the electrical alignment signatures of ice particles before the first intracloud (IC) lightning flash, and to explore the evolution of the upper charge region in the early electrification stage of an isolated thunderstorm. Negative KDP signatures associated with vertically oriented ice particles by strong electric fields in the upper parts of the thunderstorm are analyzed by introducing composite KDP, which is defined as a minimum KDP value observed in a vertical column across all elevation scans at each specific horizontal grid point at and above a designated layer. About 7 min before the first IC lightning flash, the mean canting angle of ice particles in the upper parts of the cloud changed from horizontal to vertical by strong electric fields, and the concentration of vertically aligned ice particles on the top of the cloud reached the maximum 30 s before the first IC lightning flash. These signatures exhibit an early electrification process in the upper parts of the thunderstorm. These results indicate that with the high spatial and temporal resolution, MP‐PAWRs have the ability not only to detect the rapid evolution of microphysical structures but also to observe the early electrification of thunderstorms, which will facilitate forecasting IC lightning flash initiation combined with graupel presence signatures in the mixed‐phase region in normal operation.
- 30 March 2024
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 129 (7)
Open AccessElectrical Alignment Signatures of Ice Particles Before Intracloud Lightning Activity Detected by Dual‐Polarized Phased Array Weather Radar
The cloud electrification process has great significance in understanding the microphysical properties, electrical characteristics, and evolution of thunderstorms. This study employs an X‐band dual‐polarized multiparameter phased array weather radar (MP‐PAWR) to observe the electrical alignment signatures of ice particles before the first intracloud (IC) lightning flash, and to explore the evolution of the upper charge region in the early electrification stage of an isolated thunderstorm. Negative KDP signatures associated with vertically oriented ice particles by strong electric fields in the upper parts of the thunderstorm are analyzed by introducing composite KDP, which is defined as a minimum KDP value observed in a vertical column across all elevation scans at each specific horizontal grid point at and above a designated layer. About 7 min before the first IC lightning flash, the mean canting angle of ice particles in the upper parts of the cloud changed from horizontal to vertical by strong electric fields, and the concentration of vertically aligned ice particles on the top of the cloud reached the maximum 30 s before the first IC lightning flash. These signatures exhibit an early electrification process in the upper parts of the thunderstorm. These results indicate that with the high spatial and temporal resolution, MP‐PAWRs have the ability not only to detect the rapid evolution of microphysical structures but also to observe the early electrification of thunderstorms, which will facilitate forecasting IC lightning flash initiation combined with graupel presence signatures in the mixed‐phase region in normal operation.
- 7 November 2023
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 128 (21)
Negative Excursion of Surface Electric Fields During Gamma‐Ray Glows in Winter Thunderstorms
During the 2020–2021 winter season, we detected 6 gamma‐ray glows at Kanazawa University, Japan. Negative surface electric fields (E‐fields; in the sign convention of atmospheric electricity) were observed by a field mill during all the glow cases. In five of the six cases, the peak E‐field reached around −12 kV m−1, and the E‐field during the glow detection was the strongest in the interval including 3 hr before and after the detection time. Therefore, negative charges should have been dominant in the thunderclouds that produced the gamma‐ray glows, and electrons were probably accelerated and multiplied by the E‐fields between a predominantly negative charge layer and a localized positive charge layer below. In addition, we extracted 8 non‐detection cases in the 2020–2021 winter season, in which surface E‐fields were stronger than −12 kV m−1. In 5 of the 8 cases, radar echoes were inadequately developed, suggesting insufficient charge accumulation. On the other hand, the remaining 3 cases had well‐developed radar echoes, and there was no significant difference from the detection cases.
- 7 November 2023
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 128 (21)
Negative Excursion of Surface Electric Fields During Gamma‐Ray Glows in Winter Thunderstorms
During the 2020–2021 winter season, we detected 6 gamma‐ray glows at Kanazawa University, Japan. Negative surface electric fields (E‐fields; in the sign convention of atmospheric electricity) were observed by a field mill during all the glow cases. In five of the six cases, the peak E‐field reached around −12 kV m−1, and the E‐field during the glow detection was the strongest in the interval including 3 hr before and after the detection time. Therefore, negative charges should have been dominant in the thunderclouds that produced the gamma‐ray glows, and electrons were probably accelerated and multiplied by the E‐fields between a predominantly negative charge layer and a localized positive charge layer below. In addition, we extracted 8 non‐detection cases in the 2020–2021 winter season, in which surface E‐fields were stronger than −12 kV m−1. In 5 of the 8 cases, radar echoes were inadequately developed, suggesting insufficient charge accumulation. On the other hand, the remaining 3 cases had well‐developed radar echoes, and there was no significant difference from the detection cases.
- Open Access
- 6 October 2023
- Published by Springer Nature in Progress in Earth and Planetary Science
- Vol. 10 (1) , 1-22
Advantage of bulk lightning models for predicting lightning frequency over Japan
This study examined the performance of an explicit bulk lightning model coupled with a meteorological model for forecasting lightning by numerical weather prediction over Japan. The evaluation was conducted by comparing the lightning predicted by the explicit bulk lightning model, diagnosed empirically by the numerical model, and observed by ground base measurements. From the results, the bulk lightning model performed better in terms of lightning frequency than did the diagnostic scheme, which overestimated the lightning frequency, although there were no appreciable differences in the score of each method for the geographical distribution and time correlation compared with the observations. These results suggest that the explicit bulk lightning model is advantageous for predicting lightning frequency. The sensitivity of the simulated lightning to the choice of cloud microphysical model was also examined by using a two-moment and a one-moment bulk microphysical scheme. Sensitivity experiments on the choice of microphysical model indicated that the two-moment bulk scheme reproduced the observed lightning well, while the one-moment bulk scheme overestimated the lightning frequency. Analyses suggested that the overestimation of the lightning in the one-moment bulk scheme originated from active charge separation by riming electrification, in which graupel was produced more frequently and was assumed to fall faster. These results suggest that the explicit bulk lightning model with the two-moment bulk microphysical scheme offers an alternative to conventional lightning prediction methods. Graphical abstract
- 6 October 2023
- Published by Springer Nature in Progress in Earth and Planetary Science
- Vol. 10 (1) , 1-22
Open AccessAdvantage of bulk lightning models for predicting lightning frequency over Japan
This study examined the performance of an explicit bulk lightning model coupled with a meteorological model for forecasting lightning by numerical weather prediction over Japan. The evaluation was conducted by comparing the lightning predicted by the explicit bulk lightning model, diagnosed empirically by the numerical model, and observed by ground base measurements. From the results, the bulk lightning model performed better in terms of lightning frequency than did the diagnostic scheme, which overestimated the lightning frequency, although there were no appreciable differences in the score of each method for the geographical distribution and time correlation compared with the observations. These results suggest that the explicit bulk lightning model is advantageous for predicting lightning frequency. The sensitivity of the simulated lightning to the choice of cloud microphysical model was also examined by using a two-moment and a one-moment bulk microphysical scheme. Sensitivity experiments on the choice of microphysical model indicated that the two-moment bulk scheme reproduced the observed lightning well, while the one-moment bulk scheme overestimated the lightning frequency. Analyses suggested that the overestimation of the lightning in the one-moment bulk scheme originated from active charge separation by riming electrification, in which graupel was produced more frequently and was assumed to fall faster. These results suggest that the explicit bulk lightning model with the two-moment bulk microphysical scheme offers an alternative to conventional lightning prediction methods. Graphical abstract
- Open Access
- 21 February 2023
- Published by Springer Nature in Progress in Earth and Planetary Science
- Vol. 10 (1) , 1-21
Synoptic meteorological conditions of gamma-ray glows in winter thunderstorms
The Gamma-ray Observation of Winter Thunderclouds collaboration has detected 70 gamma-ray glows, a high-energy phenomenon associated with thunderstorms, from October 2016 to March 2020 in Kanazawa and Komatsu, Ishikawa Prefecture, a central part of Japan facing the Sea of Japan. Based on surface and 500 hPa analyses, numerical prediction models, and surface and satellite observations, we classify their synoptic meteorological conditions into mainly three types. Most of the glow-detection cases were in west or west-southwest winds around the detection sites. Over half of the cases took place when a convex structure of surface pressure, often associated with a trough at 500 hPa, was formed along the coast of the Sea of Japan. Besides, we extract non-detection cases during winter thunderstorms in Kanazawa to compare with the glow-detection cases. While some of the non-detection cases have similar meteorological conditions as the glow-detection cases, most of the non-detection cases exhibited higher temperatures at the surface and 850 hPa, and higher − 10 $$^{\circ }$$ C altitudes, which indicates that electrification occurs at higher altitudes than the glow-detection cases. Therefore, gamma rays might have been produced but were attenuated before reaching the ground and undetectable at sea level.- 21 February 2023
- Published by Springer Nature in Progress in Earth and Planetary Science
- Vol. 10 (1) , 1-21
Open AccessSynoptic meteorological conditions of gamma-ray glows in winter thunderstorms
The Gamma-ray Observation of Winter Thunderclouds collaboration has detected 70 gamma-ray glows, a high-energy phenomenon associated with thunderstorms, from October 2016 to March 2020 in Kanazawa and Komatsu, Ishikawa Prefecture, a central part of Japan facing the Sea of Japan. Based on surface and 500 hPa analyses, numerical prediction models, and surface and satellite observations, we classify their synoptic meteorological conditions into mainly three types. Most of the glow-detection cases were in west or west-southwest winds around the detection sites. Over half of the cases took place when a convex structure of surface pressure, often associated with a trough at 500 hPa, was formed along the coast of the Sea of Japan. Besides, we extract non-detection cases during winter thunderstorms in Kanazawa to compare with the glow-detection cases. While some of the non-detection cases have similar meteorological conditions as the glow-detection cases, most of the non-detection cases exhibited higher temperatures at the surface and 850 hPa, and higher − 10 $$^{\circ }$$ C altitudes, which indicates that electrification occurs at higher altitudes than the glow-detection cases. Therefore, gamma rays might have been produced but were attenuated before reaching the ground and undetectable at sea level. - Open Access
- 1 January 2023
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in Journal of Atmospheric Electricity
- Vol. 42 (1) , 1-14
Characteristics of hailfall and lightning in a splitting thunderstorm observed on May 4, 2019 in the Tokyo Metropolitan Area, Japan
According to newspapers, hailfall of up to 3–4 cm in diameter was observed in the afternoon of May 4, 2019 in Tokyo, Japan. The thunderstorm cell split into two during the hailfall period, with one propagating northward with hailfall and the other propagating southward with only rainfall. For these two cells, we investigated the number of cloud-to-ground (CG) strokes identified by the lightning detection network, the temporal changes in the ice volume derived from the X-band multi-parameter radar data, and atmospheric electric fields. The results showed that the ice volume of the cell with hailfall (hailfall cell) was greater than that of the cell without hailfall (rainfall cell), whereas the number of CG strokes in the hailfall cell was smaller than that in the rainfall cell. In addition, –CG strokes were more dominant in the rainfall cell than in the hailfall cell, while +CG strokes were more dominant in the hailfall cell than in the rainfall cell. This implies that there was a large loss in negatively charged hail in the hailfall cell due to gravity, which led to an increase in net positive charge in the hailfall cell, causing +CG strokes.
- 1 January 2023
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in Journal of Atmospheric Electricity
- Vol. 42 (1) , 1-14
Open AccessCharacteristics of hailfall and lightning in a splitting thunderstorm observed on May 4, 2019 in the Tokyo Metropolitan Area, Japan
According to newspapers, hailfall of up to 3–4 cm in diameter was observed in the afternoon of May 4, 2019 in Tokyo, Japan. The thunderstorm cell split into two during the hailfall period, with one propagating northward with hailfall and the other propagating southward with only rainfall. For these two cells, we investigated the number of cloud-to-ground (CG) strokes identified by the lightning detection network, the temporal changes in the ice volume derived from the X-band multi-parameter radar data, and atmospheric electric fields. The results showed that the ice volume of the cell with hailfall (hailfall cell) was greater than that of the cell without hailfall (rainfall cell), whereas the number of CG strokes in the hailfall cell was smaller than that in the rainfall cell. In addition, –CG strokes were more dominant in the rainfall cell than in the hailfall cell, while +CG strokes were more dominant in the hailfall cell than in the rainfall cell. This implies that there was a large loss in negatively charged hail in the hailfall cell due to gravity, which led to an increase in net positive charge in the hailfall cell, causing +CG strokes.
- Open Access
- 12 October 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (10) , 1661
Temporal and Spatial Evolution of Precipitation under the Summer Sprite Parent Mesoscale Convective Systems in Japan
Transient luminous events (TLEs) are electrical discharges in the upper atmosphere caused by vigorous thunderstorms. Six sprites, which are part of TLEs, were observed on 22 July 2013 from Mt. Fuji (3776 m above sea level), Japan. All the six sprites were associated with intense positive cloud-to-ground strikes (+CGs), whose causative positive charges can reside in the stratiform region. Consequently, we assumed that the main sprites causative charges could generate an in situ charging mechanism, accompanied by precipitation growth in the extensive stratiform region. Thus, we supposed that there can be a relationship between the time sequence of surface precipitation intensity and the sprite emissions. In this study, we conclude that time sequences and horizontal evolution of Mesoscale Convective Systems (MCSs) precipitation are associated with sprites. As the result, prior to sprites 1–5, the areal amount of strong precipitation (≥8 mm/h) increased considerably, and only a small increase occurred during sprite 6. Analyzing the time sequence of the percentage of strong and weak precipitation with respect to the total precipitation, it was found that sprites 1–6 occurred within 20 min after the local peaks with respect to strong precipitation compared to total precipitation. In particular, sprites 2–5 occurred very close to local peaks. The rise time to the first peak of the strong precipitation rate associated with the first sprite was 80 min, while the rise time to the last peak associated with sprite 6 was 30 min. The temporal differences until the peaks suggest that the charging speeds, or mechanisms, related to precipitation differ between sprites 1–5 and sprite 6 in parent MCSs.
- 12 October 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (10) , 1661
Open AccessTemporal and Spatial Evolution of Precipitation under the Summer Sprite Parent Mesoscale Convective Systems in Japan
Transient luminous events (TLEs) are electrical discharges in the upper atmosphere caused by vigorous thunderstorms. Six sprites, which are part of TLEs, were observed on 22 July 2013 from Mt. Fuji (3776 m above sea level), Japan. All the six sprites were associated with intense positive cloud-to-ground strikes (+CGs), whose causative positive charges can reside in the stratiform region. Consequently, we assumed that the main sprites causative charges could generate an in situ charging mechanism, accompanied by precipitation growth in the extensive stratiform region. Thus, we supposed that there can be a relationship between the time sequence of surface precipitation intensity and the sprite emissions. In this study, we conclude that time sequences and horizontal evolution of Mesoscale Convective Systems (MCSs) precipitation are associated with sprites. As the result, prior to sprites 1–5, the areal amount of strong precipitation (≥8 mm/h) increased considerably, and only a small increase occurred during sprite 6. Analyzing the time sequence of the percentage of strong and weak precipitation with respect to the total precipitation, it was found that sprites 1–6 occurred within 20 min after the local peaks with respect to strong precipitation compared to total precipitation. In particular, sprites 2–5 occurred very close to local peaks. The rise time to the first peak of the strong precipitation rate associated with the first sprite was 80 min, while the rise time to the last peak associated with sprite 6 was 30 min. The temporal differences until the peaks suggest that the charging speeds, or mechanisms, related to precipitation differ between sprites 1–5 and sprite 6 in parent MCSs.