Thomas J. S. Durant
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thomas J. S. Durant has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Wade L. Schulz
Department of Laboratory Medicine, Yale School of Medicine, New Haven, CT
12 shared publications - Allen Hsiao
Department of Pediatrics, Yale University School of Medicine, New Haven, CT, United States
6 shared publications - Charles J Torre Jr
Department of Laboratory Medicine, Yale University School of Medicine, New Haven, Connecticut, United States of America
6 shared publications - Harlan M. Krumholz
Center for Outcomes Research and Evaluation, Yale New Haven Hospital, New Haven, CT, USA
6 shared publications Brent Nelson
Newport Healthcare, Minneapolis, MN
5 shared publications- Jacob McPadden
Department of Pediatrics, Yale University School of Medicine, New Haven, CT, USA
4 shared publications
Latest Publications
- Open Access
- 27 October 2026
- Published by American Society for Microbiology in Journal of Clinical Microbiology
AI/ML-enabled sepsis prediction systems: laboratory considerations from development to deployment
Sepsis prediction algorithms based on machine learning are increasingly embedded in electronic health record systems, and clinical laboratories have been largely absent from their development, validation, and governance. This is a consequential gap. Laboratory variables are central inputs to most deployed sepsis artificial intelligence (AI) tools, and routine analytical events such as platform transitions, reagent reformulations, and reference interval updates can shift the distributions of these inputs. Such distribution shifts are a recognized cause of degraded model performance; however, the effects of laboratory-specific changes remain insufficiently characterized for sepsis tools in clinical use. Neither clinical teams nor laboratories are currently well positioned to detect these effects. This review is written for clinical laboratorians who encounter these tools in practice or are asked to evaluate them for implementation. We describe the data sources used as model inputs and how analytical context, preanalytical variability, and ordering patterns influence model behavior. Five deployed algorithms with real-world implementation evidence are profiled alongside the broader preclinical landscape, including early warning systems, mortality and complication prediction models, and sepsis subtyping research. Development and implementation pitfalls are reviewed with attention to laboratory-specific considerations, and the regulatory and governance landscape is addressed with emphasis on where laboratorian involvement is most needed. Controlled outcomes data supporting currently deployed tools remain limited, and reported performance frequently does not replicate at external sites. Laboratorians bring expertise in analytical quality, data provenance, and change management that is not replicated elsewhere on implementation teams. As the field moves toward sepsis subtyping, continuous monitoring, and local model calibration, laboratorian expertise in analytical quality and monitoring will become increasingly central to how these tools are built, deployed, and maintained.
- 27 October 2026
- Published by American Society for Microbiology in Journal of Clinical Microbiology
Open AccessAI/ML-enabled sepsis prediction systems: laboratory considerations from development to deployment
Sepsis prediction algorithms based on machine learning are increasingly embedded in electronic health record systems, and clinical laboratories have been largely absent from their development, validation, and governance. This is a consequential gap. Laboratory variables are central inputs to most deployed sepsis artificial intelligence (AI) tools, and routine analytical events such as platform transitions, reagent reformulations, and reference interval updates can shift the distributions of these inputs. Such distribution shifts are a recognized cause of degraded model performance; however, the effects of laboratory-specific changes remain insufficiently characterized for sepsis tools in clinical use. Neither clinical teams nor laboratories are currently well positioned to detect these effects. This review is written for clinical laboratorians who encounter these tools in practice or are asked to evaluate them for implementation. We describe the data sources used as model inputs and how analytical context, preanalytical variability, and ordering patterns influence model behavior. Five deployed algorithms with real-world implementation evidence are profiled alongside the broader preclinical landscape, including early warning systems, mortality and complication prediction models, and sepsis subtyping research. Development and implementation pitfalls are reviewed with attention to laboratory-specific considerations, and the regulatory and governance landscape is addressed with emphasis on where laboratorian involvement is most needed. Controlled outcomes data supporting currently deployed tools remain limited, and reported performance frequently does not replicate at external sites. Laboratorians bring expertise in analytical quality, data provenance, and change management that is not replicated elsewhere on implementation teams. As the field moves toward sepsis subtyping, continuous monitoring, and local model calibration, laboratorian expertise in analytical quality and monitoring will become increasingly central to how these tools are built, deployed, and maintained.
- Open Access
Feature Selection with Quantum Annealing for Biomedical Machine Learning Applications
Feature selection is a commonly used method in biomedical artificial intelligence and machine learning to identify a subset of high-quality variables that can be used to train downstream predictive models. It has been suggested that quantum feature selection (QFS), which takes advantage of the properties of quantum computers, may better identify variables that are correlated with the outcome while simultaneously reducing redundancy between selected variables. However, there are a limited number of studies evaluating their performance, particularly in real-world data sets. Here, we assess the performance of two QFS methods compared to random forest (RF) feature selection based on feature stability and the performance of a downstream classification algorithm when used to predict urinary tract infections in the emergency department from 211 original features extracted from the electronic health record. We found that a quantum binary quadratic model (BQM) and constrained quadratic model (CQM) had similar performance to RF feature selection (median F1 score of 0.60, 0.61, and 0.61 respectively) when 10 features were selected for an XGBoost classification model. The BQM and RF also had similar feature stability (0.91 and 0.94, respectively) while the CQM had lower stability (0.72). These findings show that QFS can be used with large, clinical data sets to identify features with high stability and predictive performance. As the capacity and quality of quantum computers continue to increase, these methods may offer additional benefits to classical feature selection methods.
Open AccessFeature Selection with Quantum Annealing for Biomedical Machine Learning Applications
Feature selection is a commonly used method in biomedical artificial intelligence and machine learning to identify a subset of high-quality variables that can be used to train downstream predictive models. It has been suggested that quantum feature selection (QFS), which takes advantage of the properties of quantum computers, may better identify variables that are correlated with the outcome while simultaneously reducing redundancy between selected variables. However, there are a limited number of studies evaluating their performance, particularly in real-world data sets. Here, we assess the performance of two QFS methods compared to random forest (RF) feature selection based on feature stability and the performance of a downstream classification algorithm when used to predict urinary tract infections in the emergency department from 211 original features extracted from the electronic health record. We found that a quantum binary quadratic model (BQM) and constrained quadratic model (CQM) had similar performance to RF feature selection (median F1 score of 0.60, 0.61, and 0.61 respectively) when 10 features were selected for an XGBoost classification model. The BQM and RF also had similar feature stability (0.91 and 0.94, respectively) while the CQM had lower stability (0.72). These findings show that QFS can be used with large, clinical data sets to identify features with high stability and predictive performance. As the capacity and quality of quantum computers continue to increase, these methods may offer additional benefits to classical feature selection methods.
- 10 June 2026
- Published by Oxford University Press (OUP) in Laboratory Medicine
- Vol. 57 (4)
Establishing multianalyte thresholds for automated detection of EDTA contamination.
Bias in analytes due to EDTA contamination is easy to miss and represents a common and clinically relevant preanalytical error. We designed a study to determine the in vitro effects of rising rates of EDTA contamination in blood samples and to evaluate how these findings could inform the development of multianalyte thresholds for detecting such errors automatically. We incrementally spiked blood samples with increasing volumes of EDTA‑contaminated specimen and measured the resulting changes in alkaline phosphatase, calcium, magnesium, potassium, and iron levels. Using these observations, we developed a series of multianalyte thresholds and evaluated their performance against 1 year of retrospective clinical data (n = 2407). Our experiments demonstrated that increasing rates of EDTA contamination produced changes in several analytes. Accordingly, we applied multianalyte thresholds using potassium and calcium to retrospective samples. Across all samples, smaller magnitudes of analyte deviation resulted in higher detection rates of subtle EDTA contamination but poorer specificity. We selected a rule of a potassium level of 6.5 mmol/L or higher and a calcium level below 6.5 mg/dL (1.63 mmol/L), which identified 14 samples with a contamination rate of 42.8%. Multianalyte thresholds show promise as an effective approach for automatically identifying clinically significant EDTA contamination in clinical specimens.
- 10 June 2026
- Published by Oxford University Press (OUP) in Laboratory Medicine
- Vol. 57 (4)
Establishing multianalyte thresholds for automated detection of EDTA contamination.
Bias in analytes due to EDTA contamination is easy to miss and represents a common and clinically relevant preanalytical error. We designed a study to determine the in vitro effects of rising rates of EDTA contamination in blood samples and to evaluate how these findings could inform the development of multianalyte thresholds for detecting such errors automatically. We incrementally spiked blood samples with increasing volumes of EDTA‑contaminated specimen and measured the resulting changes in alkaline phosphatase, calcium, magnesium, potassium, and iron levels. Using these observations, we developed a series of multianalyte thresholds and evaluated their performance against 1 year of retrospective clinical data (n = 2407). Our experiments demonstrated that increasing rates of EDTA contamination produced changes in several analytes. Accordingly, we applied multianalyte thresholds using potassium and calcium to retrospective samples. Across all samples, smaller magnitudes of analyte deviation resulted in higher detection rates of subtle EDTA contamination but poorer specificity. We selected a rule of a potassium level of 6.5 mmol/L or higher and a calcium level below 6.5 mg/dL (1.63 mmol/L), which identified 14 samples with a contamination rate of 42.8%. Multianalyte thresholds show promise as an effective approach for automatically identifying clinically significant EDTA contamination in clinical specimens.
- 22 March 2026
- Published by Elsevier in Clinica Chimica Acta
- Vol. 588, 120981
Intraoperative tissue aspirate testing: A single-center experience and evaluation of criteria for parathyroid tissue confirmation
- 22 March 2026
- Published by Elsevier in Clinica Chimica Acta
- Vol. 588, 120981
Intraoperative tissue aspirate testing: A single-center experience and evaluation of criteria for parathyroid tissue confirmation
- Top Cited PapersOpen Access
- 23 February 2026
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 72 (4) , 451-460
Quantum Machine Learning and Data Re-Uploading: Evaluation on Benchmark and Laboratory Medicine Data Sets
Background: Quantum machine learning (QML) is an emerging field that may offer unique advantages over classical machine learning but has not been extensively studied with real-world healthcare data of practical size. This study evaluates the performance of a recently proposed quantum machine learning algorithm—quantum circuits with data re-uploading (QC-REUP)—in comparison to classical machine learning and other QML methods. Performance was assessed using both benchmarking data sets and real-world laboratory medicine data. Methods: Four data sets containing between 2 and 30 features were selected for evaluation. Initial baseline comparisons of classification performance (F1 score) were conducted using all algorithms—QC-REUP, 2 QML, and 4 classical machine learning (ML) algorithms—across the four data sets. Configuration parameters were then optimized for the QC-REUP algorithm using a previously published data set of plasma amino acid (PAA) profiles to determine the impact of optimization on classification performance, followed by a final comparison against classical ML algorithms. Results: Baseline comparisons showed that QC-REUP outperformed quantum and linear classical algorithms on lower-dimensional data sets. However, as input dimensionality increased, QML F -score declined. Following optimization, QC-REUP improved relative to baseline, and again performed comparably to linear algorithms, but ultimately demonstrated lower performance than nonlinear classical ML algorithms on the PAA data set. Conclusion: This study suggests that data re-uploading algorithms can perform comparably to classical approaches in specific contexts, particularly with low-dimensional data. While optimization can enhance performance, further improvements in quantum hardware and algorithmic development are likely needed before QML can be effectively applied in laboratory medicine and broader biomedical research.
- 23 February 2026
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 72 (4) , 451-460
Top Cited PapersOpen AccessQuantum Machine Learning and Data Re-Uploading: Evaluation on Benchmark and Laboratory Medicine Data Sets
Background: Quantum machine learning (QML) is an emerging field that may offer unique advantages over classical machine learning but has not been extensively studied with real-world healthcare data of practical size. This study evaluates the performance of a recently proposed quantum machine learning algorithm—quantum circuits with data re-uploading (QC-REUP)—in comparison to classical machine learning and other QML methods. Performance was assessed using both benchmarking data sets and real-world laboratory medicine data. Methods: Four data sets containing between 2 and 30 features were selected for evaluation. Initial baseline comparisons of classification performance (F1 score) were conducted using all algorithms—QC-REUP, 2 QML, and 4 classical machine learning (ML) algorithms—across the four data sets. Configuration parameters were then optimized for the QC-REUP algorithm using a previously published data set of plasma amino acid (PAA) profiles to determine the impact of optimization on classification performance, followed by a final comparison against classical ML algorithms. Results: Baseline comparisons showed that QC-REUP outperformed quantum and linear classical algorithms on lower-dimensional data sets. However, as input dimensionality increased, QML F -score declined. Following optimization, QC-REUP improved relative to baseline, and again performed comparably to linear algorithms, but ultimately demonstrated lower performance than nonlinear classical ML algorithms on the PAA data set. Conclusion: This study suggests that data re-uploading algorithms can perform comparably to classical approaches in specific contexts, particularly with low-dimensional data. While optimization can enhance performance, further improvements in quantum hardware and algorithmic development are likely needed before QML can be effectively applied in laboratory medicine and broader biomedical research.
- Open Access
Quantum Neural Network Tuning and Performance Evaluation for a Breast Cancer Dataset
Model tuning with the optimization of pipeline configuration is a well-established practice for the development of machine learning models. However, this often entails an exhaustive search process, especially as the parameter space expands with increasing model complexity. In the emerging field of quantum machine learning (QML), there is limited literature on the effects of configuration parameters, especially quantum-specific ones, and their choices on model performance. To address this gap, here we present a study exploring the impacts of data scaling and configuration parameters in quantum neural network (QNN) development using beta regression. Our experiments with two benchmark datasets showed that a well-tuned QNN can achieve predictive performance comparable to its classical counterparts. Our findings also demonstrate useful reference points of QNN model tuning to support a more efficient parameter optimization process.
Open AccessQuantum Neural Network Tuning and Performance Evaluation for a Breast Cancer Dataset
Model tuning with the optimization of pipeline configuration is a well-established practice for the development of machine learning models. However, this often entails an exhaustive search process, especially as the parameter space expands with increasing model complexity. In the emerging field of quantum machine learning (QML), there is limited literature on the effects of configuration parameters, especially quantum-specific ones, and their choices on model performance. To address this gap, here we present a study exploring the impacts of data scaling and configuration parameters in quantum neural network (QNN) development using beta regression. Our experiments with two benchmark datasets showed that a well-tuned QNN can achieve predictive performance comparable to its classical counterparts. Our findings also demonstrate useful reference points of QNN model tuning to support a more efficient parameter optimization process.
- Open Access
Quantum Machine Learning and Data Re-Uploading: Evaluation on Benchmark and Laboratory Medicine Datasets
Background: Quantum machine learning is an emerging field that may offer unique advantages over classical machine learning but has not been extensively studied with real-world healthcare data of practical size. This study evaluates the performance of a recently proposed quantum machine learning algorithm—quantum circuits with data re-uploading—compared to classical machine learning and other common quantum algorithms, using both benchmarking data and real-world laboratory medicine data. Methods: Four datasets containing between 2 and 30 features were selected for evaluation. The quantum re-uploading algorithm was compared against variational quantum classifiers, quantum neural networks and four, commonly used classical machine learning algorithms. Initial, baseline comparisons of classification performance (F1 score) were conducted using all algorithms across the four datasets. Configuration parameters were then optimized for the quantum data re-uploading algorithm using a previously published dataset of plasma amino acid profiles to determine the impact of optimization on classification performance, followed by a final comparison against classical ML algorithms. Results: Baseline comparisons of quantum re-uploading showed superior classification performance on lower-dimensional datasets compared to quantum and linear ML algorithms. However, performance declined significantly as the number of input features increased. While optimization improved classification performance, marked variability was observed. Following optimization, the quantum re- uploading algorithm again performed comparably to linear algorithms but had lower classification performance on the plasma amino acid dataset compared to non-linear classical algorithms. Conclusion: This study suggests that quantum data-reuploading algorithms can achieve classification performance comparable to some classical methods on lower-dimensional datasets, presenting opportunities for early research applications in laboratory medicine. However, while optimizing configuration parameters can improve classification performance, further advancements in quantum hardware and algorithm design will likely be necessary for quantum machine learning to become practically viable in laboratory medicine, and biomedical research more broadly.
Open AccessQuantum Machine Learning and Data Re-Uploading: Evaluation on Benchmark and Laboratory Medicine Datasets
Background: Quantum machine learning is an emerging field that may offer unique advantages over classical machine learning but has not been extensively studied with real-world healthcare data of practical size. This study evaluates the performance of a recently proposed quantum machine learning algorithm—quantum circuits with data re-uploading—compared to classical machine learning and other common quantum algorithms, using both benchmarking data and real-world laboratory medicine data. Methods: Four datasets containing between 2 and 30 features were selected for evaluation. The quantum re-uploading algorithm was compared against variational quantum classifiers, quantum neural networks and four, commonly used classical machine learning algorithms. Initial, baseline comparisons of classification performance (F1 score) were conducted using all algorithms across the four datasets. Configuration parameters were then optimized for the quantum data re-uploading algorithm using a previously published dataset of plasma amino acid profiles to determine the impact of optimization on classification performance, followed by a final comparison against classical ML algorithms. Results: Baseline comparisons of quantum re-uploading showed superior classification performance on lower-dimensional datasets compared to quantum and linear ML algorithms. However, performance declined significantly as the number of input features increased. While optimization improved classification performance, marked variability was observed. Following optimization, the quantum re- uploading algorithm again performed comparably to linear algorithms but had lower classification performance on the plasma amino acid dataset compared to non-linear classical algorithms. Conclusion: This study suggests that quantum data-reuploading algorithms can achieve classification performance comparable to some classical methods on lower-dimensional datasets, presenting opportunities for early research applications in laboratory medicine. However, while optimizing configuration parameters can improve classification performance, further advancements in quantum hardware and algorithm design will likely be necessary for quantum machine learning to become practically viable in laboratory medicine, and biomedical research more broadly.
- 16 April 2025
- Published by Oxford University Press (OUP) in Clinical Chemistry
Reevaluating the Threshold for Low Total Testosterone
- 16 April 2025
- Published by Oxford University Press (OUP) in Clinical Chemistry
Reevaluating the Threshold for Low Total Testosterone
- 19 March 2025
- Published by Elsevier in Clinics In Laboratory Medicine
- Vol. 45 (2) , 221-232
Automated Quality Assurance Rules for Liquid Chromatography–Mass Spectrometry Testing in a Clinical Laboratory
- 19 March 2025
- Published by Elsevier in Clinics In Laboratory Medicine
- Vol. 45 (2) , 221-232
Automated Quality Assurance Rules for Liquid Chromatography–Mass Spectrometry Testing in a Clinical Laboratory
- 15 November 2024
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 71 (2) , 296-306
Prospective and External Validation of an Ensemble Learning Approach to Sensitively Detect Intravenous Fluid Contamination in Basic Metabolic Panels
Background: Intravenous (IV) fluid contamination within clinical specimens causes an operational burden on the laboratory when detected, and potential patient harm when undetected. Even mild contamination is often sufficient to meaningfully alter results across multiple analytes. A recently reported unsupervised learning approach was more sensitive than routine workflows, but still lacked sensitivity to mild but significant contamination. Here, we leverage ensemble learning to more sensitively detect contaminated results using an approach which is explainable and generalizable across institutions. Methods: An ensemble-based machine learning pipeline of general and fluid-specific models was trained on real-world and simulated contamination and internally and externally validated. Benchmarks for performance assessment were derived from in silico simulations, in vitro experiments, and expert review. Fluid-specific regression models estimated contamination severity. SHapley Additive exPlanation (SHAP) values were calculated to explain specimen-level predictions, and algorithmic fairness was evaluated by comparing flag rates across demographic and clinical subgroups. Results: The sensitivities, specificities, and Matthews correlation coefficients were 0.858, 0.993, and 0.747 for the internal validation set, and 1.00, 0.980, and 0.387 for the external set. SHAP values provided plausible explanations for dextrose- and ketoacidosis-related hyperglycemia. Flag rates from the pipeline were higher than the current workflow, with improved detection of contamination events expected to exceed allowable limits for measurement error and reference change values. Conclusions: An accurate, generalizable, and explainable ensemble-based machine learning pipeline was developed and validated for sensitively detecting IV fluid contamination. Implementing this pipeline would help identify errors that are poorly detected by current clinical workflows and a previously described unsupervised machine learning-based method.
- 15 November 2024
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 71 (2) , 296-306
Prospective and External Validation of an Ensemble Learning Approach to Sensitively Detect Intravenous Fluid Contamination in Basic Metabolic Panels
Background: Intravenous (IV) fluid contamination within clinical specimens causes an operational burden on the laboratory when detected, and potential patient harm when undetected. Even mild contamination is often sufficient to meaningfully alter results across multiple analytes. A recently reported unsupervised learning approach was more sensitive than routine workflows, but still lacked sensitivity to mild but significant contamination. Here, we leverage ensemble learning to more sensitively detect contaminated results using an approach which is explainable and generalizable across institutions. Methods: An ensemble-based machine learning pipeline of general and fluid-specific models was trained on real-world and simulated contamination and internally and externally validated. Benchmarks for performance assessment were derived from in silico simulations, in vitro experiments, and expert review. Fluid-specific regression models estimated contamination severity. SHapley Additive exPlanation (SHAP) values were calculated to explain specimen-level predictions, and algorithmic fairness was evaluated by comparing flag rates across demographic and clinical subgroups. Results: The sensitivities, specificities, and Matthews correlation coefficients were 0.858, 0.993, and 0.747 for the internal validation set, and 1.00, 0.980, and 0.387 for the external set. SHAP values provided plausible explanations for dextrose- and ketoacidosis-related hyperglycemia. Flag rates from the pipeline were higher than the current workflow, with improved detection of contamination events expected to exceed allowable limits for measurement error and reference change values. Conclusions: An accurate, generalizable, and explainable ensemble-based machine learning pipeline was developed and validated for sensitively detecting IV fluid contamination. Implementing this pipeline would help identify errors that are poorly detected by current clinical workflows and a previously described unsupervised machine learning-based method.