Dirk Wagenaar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dirk Wagenaar has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
Stefan Both
Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
7 shared publications- Johannes Albertus Langendijk
Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
4 shared publications - Arjen van der Schaaf
Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
3 shared publications Johannes A. Langendijk
Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
3 shared publications- Armin Lühr
Department of Physics, TU Dortmund University, Dortmund, Germany
2 shared publications Daniel Scandurra
Univ Groningen, Univ Med Ctr Groningen, Dept Radiat Oncol, Groningen, Netherlands
2 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (21) , 215009
A fast and reliable quality assurance framework for CBCT-based synthetic CTs for adaptive proton radiotherapy
Objective. Cone-beam CT based synthetic CTs (sCTs) enable online adaptive proton therapy (PT) by preserving daily patient anatomy without additional acquisition of diagnostic-quality CTs. However, clinical adoption is limited by the lack of fast, reliable quality-assurance (QA) methods. This study proposes and evaluates a practical QA workflow to assess sCT suitability for proton dose optimization. Approach. A two-step sCT-QA workflow was developed in which a candidate sCT intended for reoptimization reference sCT (sCTref) is compared with an independently generated secondary sCT (sCTtest). The workflow combines image-based metrics and dose-based metrics, with doses derived from recalculating a template proton plan on both sCTs. In this study, the framework was evaluated using a deformably propagated virtual CT (vCT) as sCTref and either a deep learning-based sCT (sCTDL) or an analytically corrected CBCT (CBCTcorr) as sCTtest. Same-day CTs were deformably registered to the CBCT and used as ground truth (CT GT ) for evaluation. Thresholds were optimized using 5-fold cross-validation on 182 head-and-neck (H&N) CT-CBCT pairs. Dose calculation suitability was defined as a gamma pass rate (2%, 1 mm) exceeding 95% between dose distributions computed on sCT and CT GT . The method was further tested on an external H&N dataset and on abdominal cases. Main results. Optimal classification performance was achieved using a combination of image mean absolute error (MAE) and dose MAE. On the H&N test set, the workflow achieved balanced accuracies of 91.2% and 89.7% for the vCT-CBCTcorr and vCT-sCTDL comparisons, respectively, while maintaining a low false positive rate. When applied without modifications to the external H&N and abdominal datasets, balanced accuracy was 94.7% (HN) and 85.0% (abdominal) for vCT-CBCTcorr, and 37.9% (HN) and 61.1% (abdominal) for vCT-sCTDL. Significance. This study introduces a clinically feasible sCT-QA workflow for CBCT-based adaptive PT and showed promising transferability across datasets.
- 2 November 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (21) , 215009
Open AccessA fast and reliable quality assurance framework for CBCT-based synthetic CTs for adaptive proton radiotherapy
Objective. Cone-beam CT based synthetic CTs (sCTs) enable online adaptive proton therapy (PT) by preserving daily patient anatomy without additional acquisition of diagnostic-quality CTs. However, clinical adoption is limited by the lack of fast, reliable quality-assurance (QA) methods. This study proposes and evaluates a practical QA workflow to assess sCT suitability for proton dose optimization. Approach. A two-step sCT-QA workflow was developed in which a candidate sCT intended for reoptimization reference sCT (sCTref) is compared with an independently generated secondary sCT (sCTtest). The workflow combines image-based metrics and dose-based metrics, with doses derived from recalculating a template proton plan on both sCTs. In this study, the framework was evaluated using a deformably propagated virtual CT (vCT) as sCTref and either a deep learning-based sCT (sCTDL) or an analytically corrected CBCT (CBCTcorr) as sCTtest. Same-day CTs were deformably registered to the CBCT and used as ground truth (CT GT ) for evaluation. Thresholds were optimized using 5-fold cross-validation on 182 head-and-neck (H&N) CT-CBCT pairs. Dose calculation suitability was defined as a gamma pass rate (2%, 1 mm) exceeding 95% between dose distributions computed on sCT and CT GT . The method was further tested on an external H&N dataset and on abdominal cases. Main results. Optimal classification performance was achieved using a combination of image mean absolute error (MAE) and dose MAE. On the H&N test set, the workflow achieved balanced accuracies of 91.2% and 89.7% for the vCT-CBCTcorr and vCT-sCTDL comparisons, respectively, while maintaining a low false positive rate. When applied without modifications to the external H&N and abdominal datasets, balanced accuracy was 94.7% (HN) and 85.0% (abdominal) for vCT-CBCTcorr, and 37.9% (HN) and 61.1% (abdominal) for vCT-sCTDL. Significance. This study introduces a clinically feasible sCT-QA workflow for CBCT-based adaptive PT and showed promising transferability across datasets.
- Open Access
- 15 February 2026
- Published by Elsevier in SSRN Electronic Journal
Pseudoprogression after proton therapy in IDH-mutated glioma patients, a clinical perspective
Introduction. Pseudoprogression (PsP) after proton therapy (PT) can mimic tumour progression and may cause neurological morbidity. We characterised PsP incidence, risk factors, spatial distribution and longitudinal dynamics in adults with IDH-mutated grade 2–3 glioma treated with PT.Methods. Patients treated between 2018–2022 were included. Post-PT MRIs were centrally reviewed for contrast-enhancing PsP. We estimated actuarial incidence (Kaplan–Meier), evaluated clinical risk factors using Cox regression, and analysed lesion location and volumetric behaviour over time.Results. PsP occurred in 33/137 (24.1%) patients; 8 (5.8%) developed symptomatic PsP (CTCAE grade ≥2). Mean time to first PsP was 18.1 months, and 2-year actuarial incidence was 18.1% overall (14.7% in grade 2 and 29.0% in grade 3 glioma). Independent risk factors were age >50 years (Hazard Ratio (HR) 2.5), Fazekas grade ≥2 on pre-PT MRI (HR 3.6), and treatment in 2021 (HR 3.2).In total, 115 PsP lesions were identified: 53 (46.1%) in the periventricular space (PVS) and 5 (4.3%) in the optic pathway. All symptomatic lesions involved the PVS and/or optic pathway. Symptomatic PVS-PsP showed multifocality, earlier onset (mean 14 months), faster growth (>0.5 cc/month) and larger cumulative volumes (>1.75 cc).Conclusion. Clinically consequential PsP after PT clustered in the PVS and optic pathway. Baseline clinical factors and simple volumetric dynamics may support risk-adapted surveillance and earlier multidisciplinary review, but proposed volumetric triggers require external validation.
- 15 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPseudoprogression after proton therapy in IDH-mutated glioma patients, a clinical perspective
Introduction. Pseudoprogression (PsP) after proton therapy (PT) can mimic tumour progression and may cause neurological morbidity. We characterised PsP incidence, risk factors, spatial distribution and longitudinal dynamics in adults with IDH-mutated grade 2–3 glioma treated with PT.Methods. Patients treated between 2018–2022 were included. Post-PT MRIs were centrally reviewed for contrast-enhancing PsP. We estimated actuarial incidence (Kaplan–Meier), evaluated clinical risk factors using Cox regression, and analysed lesion location and volumetric behaviour over time.Results. PsP occurred in 33/137 (24.1%) patients; 8 (5.8%) developed symptomatic PsP (CTCAE grade ≥2). Mean time to first PsP was 18.1 months, and 2-year actuarial incidence was 18.1% overall (14.7% in grade 2 and 29.0% in grade 3 glioma). Independent risk factors were age >50 years (Hazard Ratio (HR) 2.5), Fazekas grade ≥2 on pre-PT MRI (HR 3.6), and treatment in 2021 (HR 3.2).In total, 115 PsP lesions were identified: 53 (46.1%) in the periventricular space (PVS) and 5 (4.3%) in the optic pathway. All symptomatic lesions involved the PVS and/or optic pathway. Symptomatic PVS-PsP showed multifocality, earlier onset (mean 14 months), faster growth (>0.5 cc/month) and larger cumulative volumes (>1.75 cc).Conclusion. Clinically consequential PsP after PT clustered in the PVS and optic pathway. Baseline clinical factors and simple volumetric dynamics may support risk-adapted surveillance and earlier multidisciplinary review, but proposed volumetric triggers require external validation.
- Open Access
- 9 January 2025
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 52, 100910
Relating proton LETd to biological response of parotid and submandibular glands using PSMA-PET in clinical patients
- 9 January 2025
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 52, 100910
Open AccessRelating proton LETd to biological response of parotid and submandibular glands using PSMA-PET in clinical patients
- Open Access
- 25 December 2024
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 33, 100691
Linear approximation of variable relative biological effectiveness models for proton therapy
- 25 December 2024
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 33, 100691
Open AccessLinear approximation of variable relative biological effectiveness models for proton therapy
- Open Access
- 25 December 2024
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 33, 100692
Recommendations for reporting and evaluating proton therapy beyond dose and constant relative biological effectiveness
- 25 December 2024
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 33, 100692
Open AccessRecommendations for reporting and evaluating proton therapy beyond dose and constant relative biological effectiveness
- Open Access
- 26 November 2024
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 202, 110653
Evaluating and reporting LET and RBE-weighted dose in proton therapy for glioma – The Dutch approach
- 26 November 2024
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 202, 110653
Open AccessEvaluating and reporting LET and RBE-weighted dose in proton therapy for glioma – The Dutch approach
- 15 February 2022
- Published by University of Groningen Press
Advanced treatment planning: robust optimization and proton RBE
- 15 February 2022
- Published by University of Groningen Press
Advanced treatment planning: robust optimization and proton RBE
- Open Access
- 1 December 2021
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 165, 159-165
Can the mean linear energy transfer of organs be directly related to patient toxicities for current head and neck cancer intensity-modulated proton therapy practice?
- 1 December 2021
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 165, 159-165
Open AccessCan the mean linear energy transfer of organs be directly related to patient toxicities for current head and neck cancer intensity-modulated proton therapy practice?
- Open Access
- 1 October 2021
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 163, 177-184
Does the uncertainty in relative biological effectiveness affect patient treatment in proton therapy?
- 1 October 2021
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 163, 177-184
Open AccessDoes the uncertainty in relative biological effectiveness affect patient treatment in proton therapy?
- Open Access
- 1 January 2021
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 154, 45-52
Head and neck IMPT probabilistic dose accumulation: Feasibility of a 2 mm setup uncertainty setting
- 1 January 2021
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 154, 45-52
Open AccessHead and neck IMPT probabilistic dose accumulation: Feasibility of a 2 mm setup uncertainty setting