YMYanfeng Ma

Yanfeng Ma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yanfeng Ma has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Investigations on Initial Self-Healing Failure Probability of AC Metallized Film Capacitors

    by Zijian Wang, Zichen Wang, Fei Yan, Lin Yang, Yanfeng Ma

    Self-healing failure in metallized film capacitors (MFCs) is adverse to their lifetime and will affect the stability of systems. The probability of initial self-healing failure of MFCs is influenced by various factors. In this article, an experimental setup is established to obtain the initial self-healing failure probability of MFCs under ac voltage, and the effects of interlayer pressure, temperature, film thickness and voltage on the initial self-healing failure probability are studied. The results reveal that, with the interlayer pressure increases from 200 kPa to 900 kPa, the probability of initial self-healing failure decreases first and then increases, reaching the minimum value at 600 kPa. With the temperature increases from 20 °C to 70 °C, the probability of initial self-healing failure decreases first and then increases, reaching the minimum value at 50 °C. The probability of initial self-healing failure is negatively correlated with the thickness of the film within the range of 7 μm to 10 μm. The probability of initial self-healing failure is positively correlated with voltage within the range of 1150 V to 1350 V. In the design and manufacture of MFCs, to reduce the initial self-healing failure probability, steps should be taken to improve interlayer pressure for the outer layer of cylindrical capacitor elements to 600 kPa, such as increasing the turns of wrapped film outside and optimizing heat treatment processes. For flat elements, applying a pressure of 600 kPa is appropriate; measures should be taken to control the internal temperature of MFCs close to 50 °C; thicker film can reduce the probability of initial self-healing failure; under the present design field strength, the initial self-healing failure probability of the MFCs is relatively low, and the design field strength is reasonable. The research results can provide reference for the design of MFCs.

  • AC Surface Flashover Characteristics at the Clear Edge of Metallized Polypropylene Film Capacitors

    by Zijian Wang, Yiming Lei, Fei Yan, Lin Yang, Zichen Wang, Yanfeng Ma

    Surface flashover significantly affects the insulation performance of metallized film capacitors, and the clear edge is the main area where the surface flashover occurs. An experimental platform is built to study AC surface flashover at the clear edge of metallized polypropylene film capacitors. The effects of interlayer pressure, experiment temperature, clear edge width, square resistance,absolute humidity and voltage frequency on the AC surface flashover of metallized films are investigated. The results indicate that, the surface flashover voltage and field strength increase with the increase of interlayer pressure in the range of 100 kPa to 800 kPa, and decrease with the increase of experiment temperature in the range of 30 °C to 90 °C; the flashover field strength decreases by 44% and gradually tends to be stable as the clear edge width varies from 0.5 mm to 2.5 mm; the surface flashover voltage and field strength increase by 78% as the square resistance increases from 7.5 Ω/ to 50 Ω/; the surface flashover voltage increases with the increase of absolute humidity in the range of 4 g/m3 to 16 g/m3; the surface flashover voltage and field strength decrease by 4% with the increase of voltage frequency in the range of 50 Hz to 400 Hz. In the design and manufacture of metallized film capacitors, the interlayer pressure of outer films should be appropriately increased; the design of the clear edge width of metallized film capacitors with different square resistance, operating temperatures and voltage frequencies can be selected according to the experimental results of this article. Since the moisture will be removed by heating and vacuumizing in the capacitor manufacturing process, the design of the clear edge width could refer to the experimental results under low humidity.


  • Design of the Internal Fuse Dimension for HV Shunt Capacitor in UHV Transmission Projects

    by Zijian Wang, Liqiang Wei, Fei Yan, Yongli Wu, Zichen Wang, Yanfeng Ma

    The internal fuse plays an important role in the protection of high-voltage (HV) shunt capacitors. However, there is still a lack of research on the design of the internal fuse for HV shunt capacitors. In this article, an experimental platform is built to investigate the effect of the diameter on the fusing characteristics of the fuse. The maximum nonfusing current action integral and the minimum fusing current action integral of fuses with different diameters in the range of 0.3–0.7 mm are obtained. Then, the equivalent circuits of the capacitor unit are analyzed when there is a short between terminals or element breakdown. The current flowing through the fuses with different diameters and lengths is studied, and the current action integral is calculated. Comparing them with the maximum nonfusing current action integral and the minimum fusing current action integral obtained from the experiments, the selection range of fuse diameter and length can be determined. In order to verify the rationality of the fuse design method, the internal fuse of a 668 kvar HV shunt capacitor used in ultrahigh-voltage (UHV) transmission projects is designed and validated experimentally. This article will provide a reference for the internal fuse dimension design of HV shunt capacitors.


  • Design of Current Gate Width in AC Segment Metalized Film Capacitors Based on Self-Healing Characteristics

    by Zijian Wang, Shijie Xie, Fei Yan, Yongchun Yang, Yanfeng Ma

    Segmented electrode technology is widely used in metalized film capacitors (MFCs) to limit self-healing energy and prevent self-healing failure. However, there is still a lack of research works on the design of the current gate width for ac segmented MFCs. In this article, an experimental platform is built to investigate the current flowing through the breakdown spot under ac voltage, and the effect of different factors on the current action integral is studied. The results reveal that the parallel capacitance has a little effect on the current action integral in the range of 10–160 $\mu $ F; the current action integral is negatively correlated with the interlayer pressure in the range of 20–800 kPa and the temperature in the range of $-$ 20 $^{\circ}$ C to 90 $^{\circ}$ C, while positively correlated with the voltage in the range of 950–1150 V and film thickness in the range of 7–10 $\mu $ m. The fusing criterion of the current gate is also studied experimentally. It is found that for a 1.5 mm wide current gate with square resistance $\beta $ $=$ 2 $\Omega $ / $\QED $ , the current action integral should not exceed 3.295 $\times$ 10 $^{{-5}}$ A $^{{2}}$ s. The design method of the current gate width of segmented MFCs is proposed, and the rationality of the design method is verified by experiments. The research results will provide guidance for the design of the current gate width for segmented MFCs.


  • Open Access

    Analysis and Application of Damping Characteristics of PSS and Traditional Supplementary Damping Controller based on Path-Damping Torque Coefficient Method in Wind-Thermal Bundled Power Transmission System with Series Compensation

    by Yanfeng Ma, Yijing Wang, Li Gao, Shuqiang Zhao

    Wind-thermal bundled power transmission system with series compensation (WTBPTSSC) is widely used in the power system. Power system stabilizer (PSS) and traditional supplementary damping controller (TSDC) are often installed to mitigate low-frequency oscillation (LFO) and subsynchronous oscillation (SSO) in the power system. In this paper, the damping characteristics and interaction of the controllers are analyzed to guide the coordinated control of different controllers. In light of this issue, a small-signal state-space model of WTBPTSSC was built first. Then, the path-damping torque coefficient method combined with the small-signal state-space model is proposed. The damping characteristics of PSS and TSDC were analyzed, at the same time, PSS and TSDC providing damping in different frequency bands were pointed out. Finally, through theoretical analysis and simulation verification, the conclusion is that there are few interactions between PSS and TSDC, but due to their damping characteristics, PSS should be configured in priority when the controller parameters are configured, which can make both low-frequency oscillations and subsynchronous oscillations well suppressed.

  • Study on DC Surface Flashover at the Clear Edge of Metallized Polypropylene Films

    by Zijian Wang, Cheng Qi, Fei Yan, Yanfeng Ma

    The surface flashover may occur at the clear edge of metallized films, affecting the insulation performance of metallized film capacitors (MFCs). In this article, an experimental setup was established to investigate the dc surface flashover characteristics of the metallized polypropylene film for MFCs. The effects of voltage setting, parallel capacitance, interlayer pressure, experiment temperature, and clear edge width on the flashover characteristics of metallized films were studied experimentally. The results reveal that, different voltage setting methods affect the surface flashover voltage, with a relatively stable disparity of 14.03%; parallel capacitance has little effect on the flashover characteristics in the range of 0–60 $\mu $ F; the surface flashover voltage and field strength are positively correlated with the interlayer pressure in the range of 50–800 kPa, and negatively correlated with the experiment temperature in the range of 30 $^{\circ}$ C–90 $^{\circ}$ C; as the clear edge width of the metallized film increases from 0.5 to 2.5 mm, the flashover field strength substantially decreases by 49.39% and gradually slows down to saturation. In terms of clear edge design, the width should be determined by the surface flashover voltage under the second voltage setting method; the effect of parallel capacitance on surface flashover can be ignored; measures should be taken to increase the interlayer pressure of outer films, such as increasing the turns of wrapped film outside; the clear edge width should be increased for MFCs operating at high temperature and can be selected according to the experimental data in this article.


  • Experimental Investigation on Breakdown Characteristics of Metallized Film Capacitors Under AC and DC Superimposed Voltage

    by Zijian Wang, Chengang Cui, Yanfeng Ma

    As energy storage elements in modular multilevel converter (MMC) sub-module of a unified power flow controller (UPFC), metallized film capacitors endure ac and dc superimposed voltages, which brings new challenges to insulation performance of the dielectric film. In this article, an experimental setup was created to investigate the breakdown characteristics of the dielectric film for sub-module capacitors. Factors which may affect breakdown strength under ac and dc superimposed voltages were studied experimentally. The results reveal that, as the dc voltage component increases in the range of 0-3200 V, the breakdown strength gradually increases by 16.36%; as the ac voltage component increases in the range of 0-1800 V, the breakdown strength slightly decreases by 3.52%; the breakdown strength is more affected by frequency as the ac voltage component increases and decreases with increasing frequency; as temperature increases from 20 °C to 95 °C, the breakdown strength substantially decreases by 31.12%; as the thickness of the film increases from 7 to 10 μm, the breakdown strength slightly increases by 6.32%. For capacitors in 500-kV UPFC, the dc voltage component is approximately 1600 V; the ac voltage component, whose peak-to-peak value is within 800 V, mainly contains power frequency and the second harmonic components. According to the experimental results, since the ac voltage component is small and the order of harmonic is low, the breakdown strength of capacitors in UPFC has little difference compared with that of the dc capacitors. This article can provide a reference for insulation design optimization of capacitors in UPFC.


  • Open Access

    New Energy Wide Area Complementary Planning Method for Multi-Energy Power System

    by Xun Suo, Shuqiang Zhao, Yanfeng Ma, Ling Dong

    Vigorously developing new energy is an important measure to deal with the energy crisis and environmental degradation, but the volatility and randomness of its output have brought great challenges to the new energy consumption. In this paper, the maximum new energy consumption is taken as the objective function, and the power flow constraints, multi-energy source capacity constraints and electrical constraints are taken as the constraints. Based on the complex adaptive system theory, the minimum construction step size of new energy sources is taken as the agent for modeling, focusing on the coordination among multiple sources, adjusting the installed node position and capacities of various types of power sources to obtain the optimal layout of power sources for multi-energy power systems. Based on the actual meteorological and operational data of a regional power grid in Northwest China, the original power system is re-planned. The simulation results verify the effectiveness of the proposed planning method.


  • Temperature Rise of Metallized Film Capacitors Under AC and DC Superimposed Voltage

    by Zijian Wang, Yingjie Lu, Yanfeng Ma

    The metallized film capacitors in modular multilevel converter (MMC) submodules of unified power flow controller (UPFC) endure ac and dc superimposed voltage, which raises a new problem to the research of capacitor temperature rise. This article presents an experimental setup to perform the capacitor temperature rise experiment under ac and dc superimposed voltage. The effects of ac voltage, dc voltage component, and frequency on the temperature rise of metallized film capacitor are studied experimentally. The experimental results show that dc voltage has no effect on the temperature rise of the capacitor, and the temperature rise can be calculated using the ac voltage component and equivalent series resistance (ESR). According to the equivalent circuit model of the capacitor and experimental results, it can be considered that the equivalent resistance of conductor loss and the dielectric loss factor of the polypropylene film remain unchanged in the frequency range of 0-250 Hz. With the increase in frequency, the proportion of conductor loss power in capacitor increases significantly, and it should be considered in capacitor design. The research results can guide the design and selection of metallized film capacitors in MMC submodules of UPFC.