Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Adrien Carmona has a total of 169 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impact of Balloon‐Expandable Valve Asymmetry on Heart Failure Post Transcatheter Aortic Valve Replacement

    by Shinnosuke Kikuchi, Antonin Trimaille, Adrien Carmona, Amandine Granier, Marion Kibler, Dinh Phi Truong, Kensuke Matsushita, Benjamin Marchandot, Manh Cuong Vu, Franck Zheng, et al.

    Background: Fluoroscopic assessment enables immediate evaluation of transcatheter heart valve expansion during transcatheter aortic valve replacement (TAVR). Whether fluoroscopic asymmetric expansion of balloon‐expandable valves is associated with post‐TAVR heart failure (HF) remains uncertain. Methods: Among 607 consecutive patients undergoing balloon‐expandable valve‐TAVR in a prospective registry, 589 were analyzed. Valve asymmetry was quantified using a fluoroscopic asymmetry index (%), defined as [(longest/shortest balloon‐expandable valve height)−1]×100. The primary end point was 2‐year HF hospitalization. Results: During follow‐up, 99 patients (17%) experienced HF hospitalization. As a continuous variable, asymmetry index (%) was not independently associated with 2‐year HF (adjusted hazard ratio [HR] per 1% increase, 1.02 [95% CI, 0.98–1.06]). Restricted cubic spline analysis demonstrated no significant linear or nonlinear association (overall P =0.71; P for nonlinearity=0.89), although the risk curve suggested increased HF risk beyond moderate valve asymmetry. Exploratory threshold analysis identified an asymmetry index cutoff of 7.48%. Patients above this threshold had a higher incidence of HF hospitalization than those below it (23.6% versus 15.8%; log‐rank P =0.043), despite comparable rates of impaired valve performance at discharge. Valve asymmetry >7.48% remained independently associated with late HF occurring beyond 30 days after TAVR (adjusted HR, 1.69 [95% CI, 1.10–2.60]). Conclusions: Fluoroscopic assessment of balloon‐expandable valve expansion identified patients with marked valve asymmetry at increased risk of late HF after TAVR, despite preserved early valve performance. These findings support the potential value of intraprocedural valve geometry assessment for long‐term risk stratification and warrant further investigation.


  • Bioprosthetic Valve Failure After Transcatheter Aortic Valve Replacement

    by Antonin Trimaille, Pedro Cepas-Guillén, Marina Urena, Alberto Alperi, Gabriela Veiga-Fernandez, Luis Nombela-Franco, Victoria Vilalta, Maria del Trigo, Antonio J. Muñoz-García, Giovanni Esposito, et al.

    BACKGROUND: Data on the long-term incidence and clinical impact of bioprosthetic valve failure (BVF) after transcatheter aortic valve replacement remain limited. This study aimed to assess the incidence, predictors, and clinical impact of BVF following transcatheter aortic valve replacement. METHODS: We analyzed data from an international, multicenter registry including consecutive patients undergoing transcatheter aortic valve replacement at 13 centers. The primary outcome was BVF according to Valve Academic Research Consortium-3 criteria. The cumulative incidence of BVF was estimated using a competing-risk approach. The association between BVF and clinical outcomes was assessed using competing-risk models with BVF as a time-dependent covariate. RESULTS: Among 7501 patients, BVF occurred in 380 (5.1%) patients over a median follow-up of 4 (interquartile range, 2–5) years. The cumulative incidence of BVF increased over time, reaching 1.4% at 1 year, 4.6% at 5 years, and 8.3% at 10 years. Independent predictors of BVF included younger age, smoking, balloon-expandable valve, prosthesis size P P P =0.043), and heart failure hospitalization (adjusted hazard ratio, 1.43 [95% CI, 1.03–1.98]; P =0.032). Consistent findings were observed in different sensitivity analyses. CONCLUSIONS: BVF is a clinically relevant event associated with adverse long-term outcomes. These findings support the implementation of tailored surveillance and preventive strategies to mitigate BVF-related risk.

  • Top Cited Papers
    Open Access

    Detrimental Effect of Plasma From Patients With Severe Aortic Stenosis on Valvular Endothelial Cells: Role of Proinflammatory Cytokines and Factor Xa

    by Antonin Trimaille, Sandy Hmadeh, Shinnosuke Kikuchi, Ali Mroueh, Adrien Carmona, Benjamin Marchandot, Francis Beras, Dinh Phi Truong, Manh Cuong Vu, Amandine Granier, et al.

    Background: The role of plasma and its components in the progression of aortic stenosis (AS) remains insufficiently investigated. This study aimed to assess whether plasma from patients with AS induces oxidative stress and contributes to valvular endothelial cells (VECs) dysfunction. Methods: Human plasma samples were obtained from patients with severe AS (AS+, n=110), patients with cardiovascular risk factors without AS (n=30), and healthy individuals (n=15). Plasma levels of proinflammatory cytokines (IL [interleukin]‐1β, IL‐6, TNF [tumor necrosis factor]‐α, and factor Xa [FXa]) were measured. Porcine aortic VECs were then incubated with plasma (10%, 24 hours). Oxidative stress levels were assessed using dihydroethidium staining, NO formation with 4‐amino‐5‐methylamino‐2′,7′‐difluororescein diacetate, mRNA expression by quantitative reverse transcription‐polymerase chain reaction, and protein expression levels by Western blot analyses. Platelets and monocytes adhesion as well as thrombin generation were determined. Different pharmacological inhibitors were used to explore the underlying pathways. Results: Plasma from patients with AS+ exhibited elevated levels of IL‐1β, IL‐6, TNF‐α, and FXa activity. Incubation of VECs with AS+ plasma induced a pro‐oxidant response mediated by proinflammatory cytokines, the angiotensin system‐SGLT2 (sodium‐glucose transport protein 2) pathway, and FXa. AS+ plasma also triggered VEC dysfunction, inflammation, monocytes and platelets adhesion, and thrombin generation. These detrimental effects were mitigated by empagliflozin, losartan, neutralizing antibodies targeting proinflammatory cytokines, and dabigatran and rivaroxaban. Conclusions: Patients with AS displayed subclinical systemic inflammation and increased FXa activity. These processes contributed to aortic VEC dysfunction, inflammation, monocytes and platelets adhesion, and thrombin generation upon exposure to AS+ plasma.


  • Open Access

    Optimizing patient triage on the waiting list for transcatheter aortic valve replacement: the clinical utility of the cardiac damage staging system

    by Karen Boyer, Adrien Carmona, Francois Severac, Antonin Trimaille, Kévin Roulot, Shinnosuke Kikuchi, Marion Kibler, Patrick Ohlmann, Benjamin Marchandot, Olivier Morel

    Aims: Access to transcatheter aortic valve replacement (TAVR) is generally prioritized for symptomatic patients presenting with severe heart failure, syncope, angina, and decrease in left ventricular ejection fraction 60 mmHg [sHR, 2.37 (95% CI, 1.36–4.12); P = 0.002]. Généreux stages 3 and 4 showed a strong association with waiting-list mortality, more than doubling the risk of death [sHR, 2.12 (95% CI, 1.33–3.38); P = 0.002]. Conclusion: These findings suggest that TAVR candidates at Généreux stages 3 and 4 should receive higher priority on the waiting list.


  • Open Access

    Femoral Closure with Single ProGlide® in Transcatheter Aortic Valve Implantation: A Registry-Based Study

    by Kévin Roulot, Marion Kibler, Antonin Trimaille, Adrien Carmona, Amandine Granier, Philoktimon Plastaras, Jérome Rischner, Stéphane Greciano, Pierre Leddet, Fabien De Poli, et al.

    Background: Vascular closure of the femoral artery during transcatheter aortic valve implantation (TAVI) remains a critical step prone to complications, despite advancements in introducer technology. The traditional technique involves using two ProGlide® suture closure devices (2P), but alternative approaches, such as employing a single ProGlide® device (1P), have emerged. Aims: We sought to evaluate the efficacy and safety of the 1P strategy compared to the standard 2P closure technique during transfemoral TAVI procedures. Methods: A registry-based study was conducted at the University Hospitals of Strasbourg, France, from January 2020 to December 2023. Consecutive patients who underwent TAVI via the transfemoral approach were deemed eligible. Results: The study cohort consisted of 1303 patients, with a mean age of 81.7 years and 47% female. The 1P strategy was used in 733 cases (56.3%), while the 2P technique was employed in 570 patients (43.7%). Hemostasis was achieved in the catheterization laboratory without additional devices in 30.4% of the single-ProGlide® pre-closing cases. Vascular complication rates were similar in both groups, at 11.3% for the 1P technique and 11.4% for the 2P technique (p = 0.964). However, vascular closure device failure was significantly less frequent in the 1P group (1.6%) compared to the 2P group (5.3%). Conclusions: The 1P strategy for pre-closing during TAVI is as effective and safe as the conventional 2P approach. The 1P method offers potential advantages in terms of simplicity and cost-effectiveness.


  • Refining Bleeding Risk Stratification After TAVR

    by Shinnosuke Kikuchi, Antonin Trimaille, Adrien Carmona, Amandine Granier, Dinh Phi Truong, Kensuke Matsushita, Benjamin Marchandot, Manh Cuong Vu, Marion Kibler, Franck Zheng, et al.


  • Open Access

    Subclinical Leaflet Thrombosis and Subclinical Aortic Valve Complex Thrombosis in TAVR

    by Benjamin Marchandot, Antonin Trimaille, Shinnosuke Kikuchi, Dinh Phi Truong, Adrien Carmona, Olivier Morel


  • Top Cited Papers
    Open Access

    Transcatheter Aortic Valve Durability: Focus on Structural Valve Deterioration

    by Antonin Trimaille, Adrien Carmona, Sandy Hmadeh, Dinh Phi Truong, Benjamin Marchandot, Shinnosuke Kikuchi, Kensuke Matsushita, Patrick Ohlmann, Valérie Schini‐Kerth, Josep Rodés‐Cabau, et al.

    Transcatheter aortic valve replacement has emerged as a valuable alternative to surgical aortic valve replacement in patients with severe aortic stenosis. Given the expansion of transcatheter aortic valve replacement to lower‐risk and younger populations with longer life expectancy, the durability of transcatheter heart valves (THVs) has become an important issue that may impact cardiovascular outcomes. THVs share similarities with surgical valves but have unique features, including a trend to larger effective orifice area and less prosthesis–patient mismatch, interactions with the native valve, and crimping process, that may all potentially influence a THV's life span. Multiple mechanisms may lead to bioprosthetic valve dysfunction, including structural valve deterioration, thrombosis, endocarditis, and nonstructural valve deterioration. With an incidence of up to 12.3% 5 years after transcatheter aortic valve replacement, structural valve deterioration represents the ultimate consequence of fibrotic remodeling and calcification within the bioprosthesis, driven by thrombotic and inflammatory processes involving the native aortic valve and influenced by patient and procedural factors. Understanding these mechanisms is crucial for improving THV durability.


  • Open Access

    Is Real Estate the Main Driver of Additional Costs for Cardiology Consultations in France?

    by Benjamin Marchandot, Adrien Carmona, Olivier Morel

  • Open Access

    Protruding and Ulcerated Aortic Atheromas as Predictors of Periprocedural Ischemic Stroke Post-Transcatheter Aortic Valve Replacement

    by Shinnosuke Kikuchi, Antonin Trimaille, Adrien Carmona, Dinh Phi Truong, Kensuke Matsushita, Benjamin Marchandot, Amandine Granier, Antje Reydel, Manh Cuong Vu, Franck Zheng, et al.