John D. Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
John D. Smith has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Gary Guerra
Exercise and Sport Science Department, St. Mary’s University, San Antonio, TX 78228, USA
3 shared publications Brian G. Burkholder
A Department of Counseling, Health & Kinesiology , Texas A&M University-San Antonio , San Antonio , TX, USA
1 shared publicationCynthia Schroeder
Lindenwood University
1 shared publication- Eun-Jung Yoon
Exercise and Sport Science Department, St. Mary’s University, San Antonio, TX 78228, USA
1 shared publication Rosalyn M. Smith
Texas A&M University-San Antonio
1 shared publication
Latest Publications
- Open Access
- 1 December 2023
- Published by MDPI AG in Biomechanics
- Vol. 3 (4) , 561-570
The Relationship between Balance Confidence and Center of Pressure in Lower-Limb Prosthesis Users
Background: Agreement between the activities-specific balance confidence scale (ABC) and center of pressure (CoP) in prosthesis users is still very much unknown. The purpose of this study was to investigate the agreement between ABC and CoP in lower-limb prosthesis users. Methods: Twenty-one individuals with lower-limb prostheses were recruited. Participants were provided with the ABC scale and performed static balance tasks during eyes opened (EO) and eyes closed (EC) conditions whilst standing on a force platform. Pearson product moment coefficients between CoP displacements and ABC scores were performed. Participants were also stratified by those who had better (≥80 on ABC scale) and less (t-test with Cohen’s d to estimate effect size with alpha set at 0.05 for these tests. Results: There was a significant inverse moderate relationship between eyes opened displacement (EOD) (18.3 ± 12.5 cm) and ABC (75.1 ± 18.3%), r = (19)−0.58, p = 0.006, as well as eyes closed displacement (ECD) (37.7 ± 22.1 cm) and ABC, r = (19)−0.56, p = 0.008. No significant difference in EOD (t(19) = 1.36, p = 0.189, d = 0.61) and ECD (t(19) = 1.47, p = 0.156, d = 0.66) was seen between those with greater and less balance confidence. Conclusions: Self-report and performance-based balance outcome measures are recommended when assessing lower-limb prostheses users.
- 1 December 2023
- Published by MDPI AG in Biomechanics
- Vol. 3 (4) , 561-570
Open AccessThe Relationship between Balance Confidence and Center of Pressure in Lower-Limb Prosthesis Users
Background: Agreement between the activities-specific balance confidence scale (ABC) and center of pressure (CoP) in prosthesis users is still very much unknown. The purpose of this study was to investigate the agreement between ABC and CoP in lower-limb prosthesis users. Methods: Twenty-one individuals with lower-limb prostheses were recruited. Participants were provided with the ABC scale and performed static balance tasks during eyes opened (EO) and eyes closed (EC) conditions whilst standing on a force platform. Pearson product moment coefficients between CoP displacements and ABC scores were performed. Participants were also stratified by those who had better (≥80 on ABC scale) and less (t-test with Cohen’s d to estimate effect size with alpha set at 0.05 for these tests. Results: There was a significant inverse moderate relationship between eyes opened displacement (EOD) (18.3 ± 12.5 cm) and ABC (75.1 ± 18.3%), r = (19)−0.58, p = 0.006, as well as eyes closed displacement (ECD) (37.7 ± 22.1 cm) and ABC, r = (19)−0.56, p = 0.008. No significant difference in EOD (t(19) = 1.36, p = 0.189, d = 0.61) and ECD (t(19) = 1.47, p = 0.156, d = 0.66) was seen between those with greater and less balance confidence. Conclusions: Self-report and performance-based balance outcome measures are recommended when assessing lower-limb prostheses users.
- Open Access
Correlates of Balance and Aerobic Indices in Lower-Limb Prostheses Users on Arm Crank Exercise
Background: The HUMAC Balance System (HBS) offers valid measurement of balance, and the arm crank exercise test (ACE) is a valid measure of physiological capacity. Neither have been used to evaluate associations between balance and physiological capacity in lower-limb amputees. Methods: Thirty-five participants with lower-limb amputations were recruited. Standing balance (center of pressure) was evaluated during eyes opened (EO) and eyes closed (EC) conditions using the HBS. Participants performed ACE graded exercise testing (GXT) to evaluate aerobic capacity. Spearman’s rho was used to identify relationships between variables. Cut-points for three groups were generated for time on ACE. Mann–Whitney U tests were used to explore significant differences in variables of balance and ACE between low and high performers. Results: Relationships between variables of eyes open displacement (EOD), eyes open velocity (EOV), eyes closed displacement (ECD), and eyes closed velocity (ECV) were significant (p < 0.05), and high performers with EO also performed best with EC. Longer exercise times were significantly associated with increased HRpeak, VO2peak, VEpeak, and RERpeak (p < 0.05). HRpeak (143.0 ± 30.6 b/min), VO2peak (22.7 ± 7.9 and 10.6 ± 4.7 mL/kg/min), VEpeak (80.2 ± 22.2 and 33.2 ± 12.7 L/min), and RERpeak (1.26 ± 0.08 and 1.13 ± 0.11) were significantly greater in high performers than low performers, respectively (p < 0.05). There was no significant association among VO2peak and any balance task variables; however, there were significant associations between some balance and physiological variables. Conclusions: Findings differentiated high and low performers; however, participants were still well below able-bodied norms of physical capacity. Training to mitigate deconditioning is suggested.
Open AccessCorrelates of Balance and Aerobic Indices in Lower-Limb Prostheses Users on Arm Crank Exercise
Background: The HUMAC Balance System (HBS) offers valid measurement of balance, and the arm crank exercise test (ACE) is a valid measure of physiological capacity. Neither have been used to evaluate associations between balance and physiological capacity in lower-limb amputees. Methods: Thirty-five participants with lower-limb amputations were recruited. Standing balance (center of pressure) was evaluated during eyes opened (EO) and eyes closed (EC) conditions using the HBS. Participants performed ACE graded exercise testing (GXT) to evaluate aerobic capacity. Spearman’s rho was used to identify relationships between variables. Cut-points for three groups were generated for time on ACE. Mann–Whitney U tests were used to explore significant differences in variables of balance and ACE between low and high performers. Results: Relationships between variables of eyes open displacement (EOD), eyes open velocity (EOV), eyes closed displacement (ECD), and eyes closed velocity (ECV) were significant (p < 0.05), and high performers with EO also performed best with EC. Longer exercise times were significantly associated with increased HRpeak, VO2peak, VEpeak, and RERpeak (p < 0.05). HRpeak (143.0 ± 30.6 b/min), VO2peak (22.7 ± 7.9 and 10.6 ± 4.7 mL/kg/min), VEpeak (80.2 ± 22.2 and 33.2 ± 12.7 L/min), and RERpeak (1.26 ± 0.08 and 1.13 ± 0.11) were significantly greater in high performers than low performers, respectively (p < 0.05). There was no significant association among VO2peak and any balance task variables; however, there were significant associations between some balance and physiological variables. Conclusions: Findings differentiated high and low performers; however, participants were still well below able-bodied norms of physical capacity. Training to mitigate deconditioning is suggested.
- 12 April 2019
- Published by Taylor & Francis in Disability and Rehabilitation
- Vol. 42 (22) , 3182-3188
The validity and accuracy of wrist-worn activity monitors in lower-limb prosthesis users
Purpose: To investigate the accuracy of consumer-grade wrist-worn activity monitors during over ground walking in persons using lower-limb prosthetics. Method: Thirty-two participants using lower-limb prosthetics (age = 49.7 ± 14.0 yrs, height = 176.1 ± 11.6 cm, weight = 87.8 ± 21.1 kg) were fitted with a Polar Loop, Fitbit Flex, MOVEBAND, Garmin Vivofit, and a Fitbit Charge on the right and left wrists as well as an Omron HJ-113 pedometer on the right and left hip, then walked 140 m at a self-selected pace on an indoor flat surface. Results: There were no significant differences between any of the respective right and left monitors, p > 0.05. When comparing step counts with actual step counts, Polar Loop (p = 0.001), Fitbit Flex (p = 0.001), and MOVEBAND (p = 0.001) were significantly lower than actual step counts. No significant differences existed between the remaining monitors and actual step counts (p > 0.05). Omron incurred the least error (0.6%), followed by Garmin Vivofit (1.3%) and Fitbit Charge (3.6%), with greatest error in the MOVEBAND (21.4%) and Polar Loop (13.1%). Bland–Altman plots suggest Garmin Vivofit to have the least error along with tightest agreement among the wrist-worn activity monitors Conclusion: When considering the use of consumer-grade wrist-worn activity monitors for assessing step counts in persons using lower-limb prostheses, the Garmin Vivofit seems to be the best option followed by Fitbit Charge.
- 12 April 2019
- Published by Taylor & Francis in Disability and Rehabilitation
- Vol. 42 (22) , 3182-3188
The validity and accuracy of wrist-worn activity monitors in lower-limb prosthesis users
Purpose: To investigate the accuracy of consumer-grade wrist-worn activity monitors during over ground walking in persons using lower-limb prosthetics. Method: Thirty-two participants using lower-limb prosthetics (age = 49.7 ± 14.0 yrs, height = 176.1 ± 11.6 cm, weight = 87.8 ± 21.1 kg) were fitted with a Polar Loop, Fitbit Flex, MOVEBAND, Garmin Vivofit, and a Fitbit Charge on the right and left wrists as well as an Omron HJ-113 pedometer on the right and left hip, then walked 140 m at a self-selected pace on an indoor flat surface. Results: There were no significant differences between any of the respective right and left monitors, p > 0.05. When comparing step counts with actual step counts, Polar Loop (p = 0.001), Fitbit Flex (p = 0.001), and MOVEBAND (p = 0.001) were significantly lower than actual step counts. No significant differences existed between the remaining monitors and actual step counts (p > 0.05). Omron incurred the least error (0.6%), followed by Garmin Vivofit (1.3%) and Fitbit Charge (3.6%), with greatest error in the MOVEBAND (21.4%) and Polar Loop (13.1%). Bland–Altman plots suggest Garmin Vivofit to have the least error along with tightest agreement among the wrist-worn activity monitors Conclusion: When considering the use of consumer-grade wrist-worn activity monitors for assessing step counts in persons using lower-limb prostheses, the Garmin Vivofit seems to be the best option followed by Fitbit Charge.
- 1 January 2019
- Published by Sagamore Publishing, LLC in The Physical Educator
- Vol. 76 (1) , 1-23
Pedometer Accuracy and Metabolic Cost in Elementary School Children While Walking, Skipping, Galloping, and Sliding
Pedometer Accuracy and Metabolic Cost in Elementary School Children While Walking, Skipping, Galloping, and Sliding
- 1 January 2019
- Published by Sagamore Publishing, LLC in The Physical Educator
- Vol. 76 (1) , 1-23
Pedometer Accuracy and Metabolic Cost in Elementary School Children While Walking, Skipping, Galloping, and Sliding
Pedometer Accuracy and Metabolic Cost in Elementary School Children While Walking, Skipping, Galloping, and Sliding