Yong Chu
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yong Chu has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Jinsub Kim
KSTAR operation team, National Fusion Research Institute, 124272 Daejeon Korea (the Republic of)
4 shared publications - Kwang Pyo Kim
Korea Institute of Fusion Energy (KFE), Daejeon, South Korea
4 shared publications Hirofumi Yonekawa
National Fusion Research Institute, Daejeon, Korea
3 shared publications- Hirofumi Yonekawa
KSATR Research Center, Korea Institute of Fusion Energy (KFE), Daejeon, Republic of Korea
3 shared publications - Hyunjung Lee
SC System Research Group, Korea Institute of Fusion Energy, Daejeon, South Korea
3 shared publications Young-Ok Kim
National Fusion Research Institute, Daejeon, Korea
3 shared publications
Latest Publications
- 13 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-4
Cable Modeling and DC Resistance Analysis of Terminations for 16 T Superconductor Test Facility
For the next generation fusion reactor called K-DEMO, a project of constructing 16 T (Tesla) superconducting conductor test facility, named SUCCEX (SUper Conducting Conductor EXperiment), is currently underway. It would generate the maximum magnetic field of 16 T to develop and test the superconducting magnet for K-DEMO. The SUCCEX coil system consists of a split-pair solenoid magnet, and each magnet is divided into two concentric coils, called IC (Inner Coil) and OC (Outer Coil). The IC and the OC are connected by lap joint to supply current from a power supply to the superconducting magnet. A major challenge is finding a simple and low-resistive joint design. In this study, the design and DC resistance calculation of the joint were performed including a cabling simulation. Finite element analysis method was used for the calculation of contact area of the Nb 3 Sn strands and Cu sole, and the relationship between the calculated contact resistance and pressing depth of piston was derived. The optimal design of the joints was proposed, and the calculated DC resistance was 0.82 n-Ohm.
- 13 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-4
Cable Modeling and DC Resistance Analysis of Terminations for 16 T Superconductor Test Facility
For the next generation fusion reactor called K-DEMO, a project of constructing 16 T (Tesla) superconducting conductor test facility, named SUCCEX (SUper Conducting Conductor EXperiment), is currently underway. It would generate the maximum magnetic field of 16 T to develop and test the superconducting magnet for K-DEMO. The SUCCEX coil system consists of a split-pair solenoid magnet, and each magnet is divided into two concentric coils, called IC (Inner Coil) and OC (Outer Coil). The IC and the OC are connected by lap joint to supply current from a power supply to the superconducting magnet. A major challenge is finding a simple and low-resistive joint design. In this study, the design and DC resistance calculation of the joint were performed including a cabling simulation. Finite element analysis method was used for the calculation of contact area of the Nb 3 Sn strands and Cu sole, and the relationship between the calculated contact resistance and pressing depth of piston was derived. The optimal design of the joints was proposed, and the calculated DC resistance was 0.82 n-Ohm.
- 1 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Conceptual Design of Isolated Power for Quench Detection System With Highly Insulating Stability Under Super High Field Magnets Using Wireless Power Transfer Technology
The super high field magnets using superconducting wires have been promisingly applied for thermonuclear fusion power gen-eration such as Korea Superconducting Tokamak Advanced Re-search (KSTAR) and International Thermonuclear experi-mental reactor (ITER) systems. The quench detection system (QDS) is essential for high reliability in the super high field magnet facilities. Generally, the quench voltage detection system, which uses resistive voltages, has been adopted. Especially, such an ITER magnet, the maximum operation current and voltage of superconducting keeps over 60kA and 50 kV DC. The main functions of the electron quench detection device (EQDD) are to convert high voltage signals of magnet into voltage-drop, and then send into quench monitoring system through optic cable. Especially, the EQDD which needs to an isolated power system as it surrounded high voltage enclosure by super high field mag-net. Generally, in the case of medium power, the power trans-former has been adopted for QDS as an isolated power due to stable insulating and durable characteristics. However, unfortu-nately, the magnetic saturation of electric steel for power trans-former remained fragile as well as the volume is increased un-der super high field magnet. From this reason, authors suggest the wireless power system based on resonance coupling method as a reasonable option instead of power transformer since the system can transfer power through any non-metallic media be-tween resonance antenna (Tx) and receiver (Rx) coils. In this study, authors describe the possibility of conceptual design for quench detection system with high insulation under super high field magnet using wireless power transfer technology. As the EQDD including isolated wireless power should be electrically shielded, the shielding effects for Tx coil was investigated under different intervals of shielding barrier. As well as, to expand the delivery distance between Tx and Rx coils, the operation and thermal characteristics for transfer efficiency were investigated under 370 kHz and 750 kHz RF generators, respectively.
- 1 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Conceptual Design of Isolated Power for Quench Detection System With Highly Insulating Stability Under Super High Field Magnets Using Wireless Power Transfer Technology
The super high field magnets using superconducting wires have been promisingly applied for thermonuclear fusion power gen-eration such as Korea Superconducting Tokamak Advanced Re-search (KSTAR) and International Thermonuclear experi-mental reactor (ITER) systems. The quench detection system (QDS) is essential for high reliability in the super high field magnet facilities. Generally, the quench voltage detection system, which uses resistive voltages, has been adopted. Especially, such an ITER magnet, the maximum operation current and voltage of superconducting keeps over 60kA and 50 kV DC. The main functions of the electron quench detection device (EQDD) are to convert high voltage signals of magnet into voltage-drop, and then send into quench monitoring system through optic cable. Especially, the EQDD which needs to an isolated power system as it surrounded high voltage enclosure by super high field mag-net. Generally, in the case of medium power, the power trans-former has been adopted for QDS as an isolated power due to stable insulating and durable characteristics. However, unfortu-nately, the magnetic saturation of electric steel for power trans-former remained fragile as well as the volume is increased un-der super high field magnet. From this reason, authors suggest the wireless power system based on resonance coupling method as a reasonable option instead of power transformer since the system can transfer power through any non-metallic media be-tween resonance antenna (Tx) and receiver (Rx) coils. In this study, authors describe the possibility of conceptual design for quench detection system with high insulation under super high field magnet using wireless power transfer technology. As the EQDD including isolated wireless power should be electrically shielded, the shielding effects for Tx coil was investigated under different intervals of shielding barrier. As well as, to expand the delivery distance between Tx and Rx coils, the operation and thermal characteristics for transfer efficiency were investigated under 370 kHz and 750 kHz RF generators, respectively.
- 28 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-6
Quench Phenomena in a Conduction-Cooled Fast-Ramping High Temperature Superconducting Magnet
A conduction-cooled HTS magnet was tested to produce an AC magnetic field up to 4 T for an adiabatic demagnetization refrigerator (ADR). Quench detection was conducted by measuring the voltages in the conductor, and the protection system was constructed with an external dump resistor. The magnet, which is equipped with extensive copper thermal drains, was conduction-cooled by a two-stage Gifford-McMahon cryocooler to approximately 6 K. The magnet succeeded to stably generate an alternating magnetic field between 0 and 3.5 T at a ramp rate of 229 mT/s without any pre-quench signs; however, in the case of a maximum 4 T experiment, a quench occurred, and the magnet was permanently damaged. The quench location was identified as the place where the highest perpendicular field from the magnet was generated. It is speculated that the already-formed normal zone before quench grows very fast during the dump process, and the part of the magnetic energy is dissipated in this normal zone, causing the excessive temperature rise of the conductor. The detailed experimental results are presented and discussed.
- 28 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-6
Quench Phenomena in a Conduction-Cooled Fast-Ramping High Temperature Superconducting Magnet
A conduction-cooled HTS magnet was tested to produce an AC magnetic field up to 4 T for an adiabatic demagnetization refrigerator (ADR). Quench detection was conducted by measuring the voltages in the conductor, and the protection system was constructed with an external dump resistor. The magnet, which is equipped with extensive copper thermal drains, was conduction-cooled by a two-stage Gifford-McMahon cryocooler to approximately 6 K. The magnet succeeded to stably generate an alternating magnetic field between 0 and 3.5 T at a ramp rate of 229 mT/s without any pre-quench signs; however, in the case of a maximum 4 T experiment, a quench occurred, and the magnet was permanently damaged. The quench location was identified as the place where the highest perpendicular field from the magnet was generated. It is speculated that the already-formed normal zone before quench grows very fast during the dump process, and the part of the magnetic energy is dissipated in this normal zone, causing the excessive temperature rise of the conductor. The detailed experimental results are presented and discussed.
- 10 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
AC Loss Analysis on the KSTAR PF1L Coil Based on the Long-Term Commissioning Shot Data
The Korea Superconducting Tokamak Advanced Research (KSTAR) uses superconductors for all of its magnets. During plasma operation, various high AC losses, including hysteresis loss, coupling current loss, eddy current loss, and others, are generated in the Central Solenoid (CS) and Poloidal Field (PF) coils. Thus, it is important to analyze AC losses of a superconducting magnet for its reliable operation in two main perspectives: short term quench prevention and long term steady-operation. With 10 years of operation, KSTAR has provided many invaluable data in superconducting magnet operation regarding AC loss issues. This paper focuses on the AC loss of the KSATR CS coil based on the long-term operation data. The CS coil of the KSTAR consists of 4 sets of PF coils, PF1 to PF4. PF1 coil especially experiences the largest magnetic field and variations, and consequently the largest loss due to its central location in CS coil. The experimental results of the total loss measured for PF1 are introduced. Then, each AC loss is calculated numerically to relate to the total loss results. Finally, the results are interpreted qualitatively regarding the critical current density and effective coupling time constant to investigate the possible relation between the AC loss and the magnet's performance.
- 10 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
AC Loss Analysis on the KSTAR PF1L Coil Based on the Long-Term Commissioning Shot Data
The Korea Superconducting Tokamak Advanced Research (KSTAR) uses superconductors for all of its magnets. During plasma operation, various high AC losses, including hysteresis loss, coupling current loss, eddy current loss, and others, are generated in the Central Solenoid (CS) and Poloidal Field (PF) coils. Thus, it is important to analyze AC losses of a superconducting magnet for its reliable operation in two main perspectives: short term quench prevention and long term steady-operation. With 10 years of operation, KSTAR has provided many invaluable data in superconducting magnet operation regarding AC loss issues. This paper focuses on the AC loss of the KSATR CS coil based on the long-term operation data. The CS coil of the KSTAR consists of 4 sets of PF coils, PF1 to PF4. PF1 coil especially experiences the largest magnetic field and variations, and consequently the largest loss due to its central location in CS coil. The experimental results of the total loss measured for PF1 are introduced. Then, each AC loss is calculated numerically to relate to the total loss results. Finally, the results are interpreted qualitatively regarding the critical current density and effective coupling time constant to investigate the possible relation between the AC loss and the magnet's performance.
- 21 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Analysis of the Mechanical Behavior of the KSTAR CS Magnet During Long-Pulse Plasma Discharges
The KSTAR central solenoid (CS) magnet consists of four pairs of coils stacked vertically and eight preloading structures that compress the coils in the axial direction. The strain and dis-placement of the CS magnet are monitored in real time, limiting the minimum compression as an important parameter of the su-pervisory interlock system for the safe operation of KSTAR. An equivalent vertical force method for a simplified multi-spring system was developed to analyze the preload and displacement variations of the CS magnet. The equivalent vertical force is based on the plasma and poloidal field (PF) coils currents during plasma discharge. The estimated displacements by the developed method agreed fairly well with the measured displacements of the long-pulse plasma discharges in 2017 (#18437) and 2018 (#21735) campaigns. The analyzed displacement can be used to simply estimate the remaining preload of the CS coils. This ap-proach will contribute to the development of advanced operation scenarios for large plasma current and long-pulse discharges. By applying this algorithm to the plasma control system, the CS magnet can be controlled more safely during KSTAR operation.
- 21 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Analysis of the Mechanical Behavior of the KSTAR CS Magnet During Long-Pulse Plasma Discharges
The KSTAR central solenoid (CS) magnet consists of four pairs of coils stacked vertically and eight preloading structures that compress the coils in the axial direction. The strain and dis-placement of the CS magnet are monitored in real time, limiting the minimum compression as an important parameter of the su-pervisory interlock system for the safe operation of KSTAR. An equivalent vertical force method for a simplified multi-spring system was developed to analyze the preload and displacement variations of the CS magnet. The equivalent vertical force is based on the plasma and poloidal field (PF) coils currents during plasma discharge. The estimated displacements by the developed method agreed fairly well with the measured displacements of the long-pulse plasma discharges in 2017 (#18437) and 2018 (#21735) campaigns. The analyzed displacement can be used to simply estimate the remaining preload of the CS coils. This ap-proach will contribute to the development of advanced operation scenarios for large plasma current and long-pulse discharges. By applying this algorithm to the plasma control system, the CS magnet can be controlled more safely during KSTAR operation.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Conceptual Design of a 5 T 200 mm 1 T/s Ramping NbTi Synchrotron Magnet for Cancer Treatment
Recently, a collaborative research to develop an all-superconducting synchrotron system for cancer treatment was embarked by a team led by Electronics and Telecommunications Research Institute in Korea. The system requires a 5 T dipole magnet with a uniform field region in cylindrical shape of 130 mm in diameter and 3000 mm in length, and operates at a ramping rate of 1 T/s. As the first step of the project, this paper presents a conceptual design of the magnet that consists of six single-layer cosine windings made of the NbTi Rutherford cable. Key design results include: (1) spatial field uniformity, $\Delta B/B < 2\times 10^{-4}$ within a target space of $|r|< $ 65 mm; (2) total ac loss of the entire coils, 297 J per cycle for a normal operation of 1 T $\rightarrow$ 5 T $\rightarrow$ 1 T at the 1 T/s ramping rate; (3) ac-loss-oriented cryogenic load of 23 W; (4) peak temperature of 4.9 K within the magnet during the consecutive normal operation; (5) enthalpy margin of 2.1 mJ/cm $^3$ with the current sharing temperature of 5.65 K; and (6) adiabatic temperature rise of 87 K upon a quench.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Conceptual Design of a 5 T 200 mm 1 T/s Ramping NbTi Synchrotron Magnet for Cancer Treatment
Recently, a collaborative research to develop an all-superconducting synchrotron system for cancer treatment was embarked by a team led by Electronics and Telecommunications Research Institute in Korea. The system requires a 5 T dipole magnet with a uniform field region in cylindrical shape of 130 mm in diameter and 3000 mm in length, and operates at a ramping rate of 1 T/s. As the first step of the project, this paper presents a conceptual design of the magnet that consists of six single-layer cosine windings made of the NbTi Rutherford cable. Key design results include: (1) spatial field uniformity, $\Delta B/B < 2\times 10^{-4}$ within a target space of $|r|< $ 65 mm; (2) total ac loss of the entire coils, 297 J per cycle for a normal operation of 1 T $\rightarrow$ 5 T $\rightarrow$ 1 T at the 1 T/s ramping rate; (3) ac-loss-oriented cryogenic load of 23 W; (4) peak temperature of 4.9 K within the magnet during the consecutive normal operation; (5) enthalpy margin of 2.1 mJ/cm $^3$ with the current sharing temperature of 5.65 K; and (6) adiabatic temperature rise of 87 K upon a quench.
- 14 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Quench Detection of the KSTAR CS Coil by Considering Plasma Current Effect
The plasma-driven inductive voltages were not negligi-ble and should be taken into account for the reliable operation of the voltage-based quench detection of the KSTAR CS coil. For the ac-tive compensation of such plasma-induced voltage noise, plasma pa-rameters should be measured in real time and applied to the quench detection system. The selection of plasma parameters by considering their contribution to the noise is of primary importance. A code, which can estimate the induced coil voltage driven by plasma, is de-veloped by using a simplified plasma response modelling. The nu-merical analysis has showed that there was an apparent influence from the plasma, while the influence from eddy currents induced in passive structures was negligible. The change of plasma current is the primary noise source and the radial and vertical motions of plasma have an effect, although they were small. The performance of the quench detector was developed and tested during the 2017 KSTAR campaign. The noise rejection performance was discussed with various experimental results and numerical estimations.
- 14 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Quench Detection of the KSTAR CS Coil by Considering Plasma Current Effect
The plasma-driven inductive voltages were not negligi-ble and should be taken into account for the reliable operation of the voltage-based quench detection of the KSTAR CS coil. For the ac-tive compensation of such plasma-induced voltage noise, plasma pa-rameters should be measured in real time and applied to the quench detection system. The selection of plasma parameters by considering their contribution to the noise is of primary importance. A code, which can estimate the induced coil voltage driven by plasma, is de-veloped by using a simplified plasma response modelling. The nu-merical analysis has showed that there was an apparent influence from the plasma, while the influence from eddy currents induced in passive structures was negligible. The change of plasma current is the primary noise source and the radial and vertical motions of plasma have an effect, although they were small. The performance of the quench detector was developed and tested during the 2017 KSTAR campaign. The noise rejection performance was discussed with various experimental results and numerical estimations.
- 5 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-4
Analysis of Voltage Noises for the Reliability Improvement of the KSTAR CS Quench Detection
In the Korea Superconducting Tokamak Advanced Research (KSTAR), quench detection system using central difference averaging (CDA) and mutual inductance compensation (MIK) for central solenoid (CS) magnet has been studied. Similar to the cowound voltage taps, it is expected that this method can provide the good capability of rejecting inductive voltage noise. Accordingly, CDA and MIK method could be considered as a promising way. For this method to be an effective way, the inductive voltages should be accurately estimated, and then the measured CDA voltages are compared with the estimated ones. In previous studies, CS and poloidal field (PF) coils were modeled as the ideal solenoids to calculate mutual inductances between them. However, the nonlinearity of inductances due to Incoloy-908 jackets of PF1-PF5 coils that are ferromagnetic materials still needs to be compensated for more accurate estimation of inductive voltages. In this paper, the inductive voltages were estimated by considering the ferromagnetic effect of Incoloy-908 jackets to compensate the error voltages. Based on this study, the effect of Incoloy-908 on accuracy and reliability of CDA and MIK quench detection scheme was analyzed and discussed.
- 5 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-4
Analysis of Voltage Noises for the Reliability Improvement of the KSTAR CS Quench Detection
In the Korea Superconducting Tokamak Advanced Research (KSTAR), quench detection system using central difference averaging (CDA) and mutual inductance compensation (MIK) for central solenoid (CS) magnet has been studied. Similar to the cowound voltage taps, it is expected that this method can provide the good capability of rejecting inductive voltage noise. Accordingly, CDA and MIK method could be considered as a promising way. For this method to be an effective way, the inductive voltages should be accurately estimated, and then the measured CDA voltages are compared with the estimated ones. In previous studies, CS and poloidal field (PF) coils were modeled as the ideal solenoids to calculate mutual inductances between them. However, the nonlinearity of inductances due to Incoloy-908 jackets of PF1-PF5 coils that are ferromagnetic materials still needs to be compensated for more accurate estimation of inductive voltages. In this paper, the inductive voltages were estimated by considering the ferromagnetic effect of Incoloy-908 jackets to compensate the error voltages. Based on this study, the effect of Incoloy-908 on accuracy and reliability of CDA and MIK quench detection scheme was analyzed and discussed.
- 23 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
Analyzing a Cooling Experiment of a Prototype Thermosiphon System for a Single Crystal Silicon Ingot Growing Magnet
Thermosiphon system is a method of cooling large scale superconducting magnet systems; the system functions by circulating cryogen through a cooling channel. In this paper, a small scale prototype thermosiphon system is designed for a single crystal ingot growing magnet. The design is based on liquid and gaseous helium circulation. The cooling performance of the system is analyzed experimentally. The experiment is conducted with different heat loads to investigate the effects of different magnet heat loads such as AC losses. The prototype system showed satisfactory cooling performance when the heat load was under 0.75W. However, an unstable system pressure was reported when the heat load was over 0.75 W. Based on the result, a conceptual revised topology of the prototype system is suggested as a possible solution to the unstable pressure.
- 23 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
Analyzing a Cooling Experiment of a Prototype Thermosiphon System for a Single Crystal Silicon Ingot Growing Magnet
Thermosiphon system is a method of cooling large scale superconducting magnet systems; the system functions by circulating cryogen through a cooling channel. In this paper, a small scale prototype thermosiphon system is designed for a single crystal ingot growing magnet. The design is based on liquid and gaseous helium circulation. The cooling performance of the system is analyzed experimentally. The experiment is conducted with different heat loads to investigate the effects of different magnet heat loads such as AC losses. The prototype system showed satisfactory cooling performance when the heat load was under 0.75W. However, an unstable system pressure was reported when the heat load was over 0.75 W. Based on the result, a conceptual revised topology of the prototype system is suggested as a possible solution to the unstable pressure.
- Open Access
- 31 March 2016
- Published by The Korea Institute of Applied Superconductivity and Cryogenics in Progress in Superconductivity and Cryogenics
- Vol. 18 (1) , 55-58
Study on quench detection of the KSTAR CS coil with CDA+MIK compensation of inductive voltages
- 31 March 2016
- Published by The Korea Institute of Applied Superconductivity and Cryogenics in Progress in Superconductivity and Cryogenics
- Vol. 18 (1) , 55-58
Open AccessStudy on quench detection of the KSTAR CS coil with CDA+MIK compensation of inductive voltages