José Ángel Fernández-Rubiera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
José Ángel Fernández-Rubiera has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Arsenio Barbón
Department of Electrical Engineering, University of Oviedo, 33003 Oviedo, Spain
4 shared publications - Luis Bayon
University of Oviedo
3 shared publications - Alberto Martin Pernia
Department of Electrical Engineering, University of Oviedo, 33204 Gijón, Spain
1 shared publication - Covadonga Bayón-Cueli
Polytechnic School of Engineering of Gijón, University of Oviedo, 33203 Gijón, Spain
1 shared publication - Fernando Nuno
Department of Electric, Electronic, Computer and Systems Engineering, University of Oviedo, 33203 Gijón, Spain
1 shared publication - Jaime Martínez-Suárez
Ingeniería de Procesos, Energía y Calidad SL (INGEPEC), 33401 Avilés, Spain
1 shared publication
Latest Publications
- Open Access
- 21 April 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (8) , 4571
Experimental and Theoretical Evaluation of Incident Solar Irradiance on Photovoltaic Power Plants Under Real Operating Conditions: Fixed Tilt Angle System vs. Horizontal Single-Axis Tracker
The aim of this paper was to delve deeper into the nuances of incident solar irradiance on the photovoltaic field of a fixed tilt angle system versus a horizontal single-axis tracker. The fixed tilt angle system was used as a baseline for comparison. Three assessment indicators were analysed (annual energy gain (), monthly energy gain (), daily energy gain ()). The procedure used comprised the following steps: (i) choice of solar irradiance estimation model; (ii) theoretical study; (iii) study under real operating conditions—for this purpose, an experimental setup was used; and (iv) comparison of these studies. The experimental setup was installed at the Department of Electrical Engineering of the University of Oviedo (Gijón, Spain) (latitude N, longitude W, elevation 28 (m) above sea level). Gijón is characterised by a temperate oceanic climate typical of Spain’s Atlantic coast, with cool summers and wet and mostly mild winters. The code assigned to Gijón under the Köppen climate classification is . The horizontal single-axis trackers that comprise photovoltaic power plants have three operating modes (Scenario 1). Some studies consider a unique mode of operation from sunrise to sunset (Scenario 2). The following conclusions can be drawn from the results obtained: (i) although the results obtained in the theoretical study and in the study under real operating conditions were different, a trend can be seen in the results; for example, the obtained was approximately and in the theoretical study and in the real study, respectively, in Scenario 1 and approximately and , respectively, in Scenario 2; Scenario 2 obtained higher results than Scenario 1 in all the assessment indicators; but it must be considered that Scenario 1 is the real mode of operation; (ii) from March to September, the horizontal single-axis tracker generates more electrical energy; as this period contains the months of greatest solar irradiance, the horizontal single-axis tracker performs better annually; considering the theoretical study and Scenario 1, the highest value of was in June () and the lowest was in December (); when the study was considered under real operating conditions, the highest result was in July () and the lowest was in December (); (iii) on the days between 70 and 277 in Scenario 1, the horizontal single-axis tracker generated more electrical energy; on the other days the opposite occurred; taking into account the theoretical study, the highest and lowest values were and , respectively; when the study was considered under real operating conditions, the highest and lowest values were and , respectively.- 21 April 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (8) , 4571
Open AccessExperimental and Theoretical Evaluation of Incident Solar Irradiance on Photovoltaic Power Plants Under Real Operating Conditions: Fixed Tilt Angle System vs. Horizontal Single-Axis Tracker
The aim of this paper was to delve deeper into the nuances of incident solar irradiance on the photovoltaic field of a fixed tilt angle system versus a horizontal single-axis tracker. The fixed tilt angle system was used as a baseline for comparison. Three assessment indicators were analysed (annual energy gain (), monthly energy gain (), daily energy gain ()). The procedure used comprised the following steps: (i) choice of solar irradiance estimation model; (ii) theoretical study; (iii) study under real operating conditions—for this purpose, an experimental setup was used; and (iv) comparison of these studies. The experimental setup was installed at the Department of Electrical Engineering of the University of Oviedo (Gijón, Spain) (latitude N, longitude W, elevation 28 (m) above sea level). Gijón is characterised by a temperate oceanic climate typical of Spain’s Atlantic coast, with cool summers and wet and mostly mild winters. The code assigned to Gijón under the Köppen climate classification is . The horizontal single-axis trackers that comprise photovoltaic power plants have three operating modes (Scenario 1). Some studies consider a unique mode of operation from sunrise to sunset (Scenario 2). The following conclusions can be drawn from the results obtained: (i) although the results obtained in the theoretical study and in the study under real operating conditions were different, a trend can be seen in the results; for example, the obtained was approximately and in the theoretical study and in the real study, respectively, in Scenario 1 and approximately and , respectively, in Scenario 2; Scenario 2 obtained higher results than Scenario 1 in all the assessment indicators; but it must be considered that Scenario 1 is the real mode of operation; (ii) from March to September, the horizontal single-axis tracker generates more electrical energy; as this period contains the months of greatest solar irradiance, the horizontal single-axis tracker performs better annually; considering the theoretical study and Scenario 1, the highest value of was in June () and the lowest was in December (); when the study was considered under real operating conditions, the highest result was in July () and the lowest was in December (); (iii) on the days between 70 and 277 in Scenario 1, the horizontal single-axis tracker generated more electrical energy; on the other days the opposite occurred; taking into account the theoretical study, the highest and lowest values were and , respectively; when the study was considered under real operating conditions, the highest and lowest values were and , respectively. - Open Access
- 21 June 2023
- Published by MDPI AG in Electronics
- Vol. 12 (13) , 2770
Sawtooth V-Trough Cavity for Low-Concentration Photovoltaic Systems Based on Small-Scale Linear Fresnel Reflectors: Optimal Design, Verification, and Construction
Ensuring the uniformity of solar irradiance distribution on photovoltaic cells is a major challenge in low-concentrating photovoltaic systems based on a small-scale linear Fresnel reflector. A novel sawtooth V-cavity design method based on an optimization algorithm to achieve uniform irradiance distribution on photovoltaic cells is presented. The reliability of the design was verified using the Monte Carlo ray-tracing method and a laser experiment. A prototype was built using 3D printing technology with a biodegradable green polymer material known as polylactic acid. The new cavity was compared to the standard V-trough cavity, keeping the cavity aperture, reflective surface area, and photovoltaic cell width constant. In addition, the focal height, number of mirrors, mirror width, and mirror spacing were also kept constant; so, the cost of the two configurations was the same from the point of view of the primary reflector system. The new design ensured the uniform distribution of solar irradiation and significantly reduced the height of the cavity. The significant decrease in the height of the proposed cavity has the following advantages: (i) a decrease in the dimensions of the fixed structure of the small-scale linear Fresnel reflector, thus reducing its cost, (ii) a significant decrease in the surface area exposed to wind loads, thus reducing the cost of the fixed structure and secondary system structures, (iii) a reduction in the difficulty of the manufacture, maintenance, and transportation of the cavity’s reflecting walls, and (iv) an increase in the cooling surface area, which increases the electrical efficiency of the photovoltaic cells.
- 21 June 2023
- Published by MDPI AG in Electronics
- Vol. 12 (13) , 2770
Open AccessSawtooth V-Trough Cavity for Low-Concentration Photovoltaic Systems Based on Small-Scale Linear Fresnel Reflectors: Optimal Design, Verification, and Construction
Ensuring the uniformity of solar irradiance distribution on photovoltaic cells is a major challenge in low-concentrating photovoltaic systems based on a small-scale linear Fresnel reflector. A novel sawtooth V-cavity design method based on an optimization algorithm to achieve uniform irradiance distribution on photovoltaic cells is presented. The reliability of the design was verified using the Monte Carlo ray-tracing method and a laser experiment. A prototype was built using 3D printing technology with a biodegradable green polymer material known as polylactic acid. The new cavity was compared to the standard V-trough cavity, keeping the cavity aperture, reflective surface area, and photovoltaic cell width constant. In addition, the focal height, number of mirrors, mirror width, and mirror spacing were also kept constant; so, the cost of the two configurations was the same from the point of view of the primary reflector system. The new design ensured the uniform distribution of solar irradiation and significantly reduced the height of the cavity. The significant decrease in the height of the proposed cavity has the following advantages: (i) a decrease in the dimensions of the fixed structure of the small-scale linear Fresnel reflector, thus reducing its cost, (ii) a significant decrease in the surface area exposed to wind loads, thus reducing the cost of the fixed structure and secondary system structures, (iii) a reduction in the difficulty of the manufacture, maintenance, and transportation of the cavity’s reflecting walls, and (iv) an increase in the cooling surface area, which increases the electrical efficiency of the photovoltaic cells.
- Open Access
Theoretical Deduction of the Optimum Tilt Angles for Small-Scale Linear Fresnel Reflectors
A theoretical justification and computation of the optimum values of the two longitudinal tilt angles of a small-scale linear Fresnel reflector is provided. The optimum angle of the mobile structure is proved to be half the latitude of the geographic location, while the optimum angle of the secondary reflector system is proved to be equal to that latitude. Brute-force verification is carried out for five EU cities, each in one of the five European climate zones.
Open AccessTheoretical Deduction of the Optimum Tilt Angles for Small-Scale Linear Fresnel Reflectors
A theoretical justification and computation of the optimum values of the two longitudinal tilt angles of a small-scale linear Fresnel reflector is provided. The optimum angle of the mobile structure is proved to be half the latitude of the geographic location, while the optimum angle of the secondary reflector system is proved to be equal to that latitude. Brute-force verification is carried out for five EU cities, each in one of the five European climate zones.
- Open Access
Li-Po Battery Charger Based on the Constant Current/Voltage Parallel Resonant Converter Operating in ZVS
Battery requirements for electrical vehicles are continuously becoming more demanding in terms of energy density and reliability. Nowadays, batteries for drones must be able to supply 100 A for 15 min, not to mention the specifications required for batteries in electrical vehicles. These specifications result in more stringent specifications for battery chargers. They are required to be more efficient, flexible, and, as with any another power equipment, to have reduced size and weight. Since the parallel resonant converter can operate as a current source and as a voltage source, this paper presents a battery charger power stage for lithium ion polymer batteries, based on the above topology, operating in zero voltage switching mode, and implementing frequency and duty cycle control.
Open AccessLi-Po Battery Charger Based on the Constant Current/Voltage Parallel Resonant Converter Operating in ZVS
Battery requirements for electrical vehicles are continuously becoming more demanding in terms of energy density and reliability. Nowadays, batteries for drones must be able to supply 100 A for 15 min, not to mention the specifications required for batteries in electrical vehicles. These specifications result in more stringent specifications for battery chargers. They are required to be more efficient, flexible, and, as with any another power equipment, to have reduced size and weight. Since the parallel resonant converter can operate as a current source and as a voltage source, this paper presents a battery charger power stage for lithium ion polymer batteries, based on the above topology, operating in zero voltage switching mode, and implementing frequency and duty cycle control.