Hang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hang Li has a total of 115 co-authors. Here are the top co-authors by number of shared publications:
- Haiyang Li
State Key Laboratory of Medical Proteomics, Dalian Institute of Chemical Physics
7 shared publications Huaiwen Cang
State Key Laboratory of Medical Proteomics, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, People's Republic of China; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian Key Laboratory for Online Analytical Instrumentation, Dalian, 116023, People's Republic of China
5 shared publications- Lei Hua
Dalian Institute of Chemical Physics, Chinese Academy of Sciences
3 shared publications Zhihao Zhang
Chinese Academy of Sciences
3 shared publications- Chuang Chen
State Key Laboratory of Medical Proteomics, Dalian Institute of Chemical Physics
2 shared publications - Dechao Geng
State Key Laboratory of Advanced Materials for Intelligent Sensing, Ministry of Science and Technology & Key Laboratory of Organic Integrated Circuit, Ministry of Education & Tianjin Key Laboratory of Molecular Optoelectronic Sciences, Department of Chemistry, School of Science, Tianjin University, Tianjin 300072, China
2 shared publications
Latest Publications
- Open Access
- 5 October 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Fumarate hydratase deficiency triggers disulfidptosis under glucose deprivation
Disulfidptosis is cell death caused by abnormal disulfide bonds, previously observed in cells with high SLC7A11 expression under glucose starvation. Whether other conditions can induce disulfidptosis remains unclear. However, we demonstrate that fumarate hydratase (FH)-deficient cells undergo disulfidptosis under glucose starvation. FH deficiency drives abnormal disulfide accumulation, promotes actin contraction, and consequently leads to cytoskeleton-plasma membrane dissociation. Under glucose starvation conditions, impaired oxidative tricarboxylic acid (TCA) cycle function in FH-deficient cells compromises NAD(P)H (the reduced forms of nicotinamide adenine dinucleotide and its phosphate) homeostasis, leading to redox system collapse. We find that targeting mitochondrial complex I enhances the reductive TCA cycle activity driving NADPH consumption while simultaneously suppressing the oxidative TCA cycle, thereby inducing disulfidptosis in the presence of glucose. Our findings establish a mechanistic link between FH deficiency and disulfidptosis, and define a therapeutically actionable vulnerability in FH-deficient tumors.
- 5 October 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessFumarate hydratase deficiency triggers disulfidptosis under glucose deprivation
Disulfidptosis is cell death caused by abnormal disulfide bonds, previously observed in cells with high SLC7A11 expression under glucose starvation. Whether other conditions can induce disulfidptosis remains unclear. However, we demonstrate that fumarate hydratase (FH)-deficient cells undergo disulfidptosis under glucose starvation. FH deficiency drives abnormal disulfide accumulation, promotes actin contraction, and consequently leads to cytoskeleton-plasma membrane dissociation. Under glucose starvation conditions, impaired oxidative tricarboxylic acid (TCA) cycle function in FH-deficient cells compromises NAD(P)H (the reduced forms of nicotinamide adenine dinucleotide and its phosphate) homeostasis, leading to redox system collapse. We find that targeting mitochondrial complex I enhances the reductive TCA cycle activity driving NADPH consumption while simultaneously suppressing the oxidative TCA cycle, thereby inducing disulfidptosis in the presence of glucose. Our findings establish a mechanistic link between FH deficiency and disulfidptosis, and define a therapeutically actionable vulnerability in FH-deficient tumors.
- 15 July 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (29) , 21157-21164
Spatially Confined Photoinduced Penning Ionization for Highly Sensitive Mass Spectrometry
In vacuum ultraviolet (VUV) lamp-based photoionization mass spectrometry (PI-MS), the axially mounted configuration exhibits higher sensitivity due to a longer light absorption path. However, VUV light irradiation of the metal surfaces within the transmission chamber induces photoelectron emission; excessive background gas ions are generated via photoelectron ionization under the radio frequency (RF) electric field, which affects the quantitative performance and repeatability of PI-MS, especially for deuterium lamps with a higher photon flux. In this study, a size- and position-adjustable baffle electrode was integrated into the ionization chamber to reduce the light leakage into the transmission chamber. For a 3 mm-diameter baffle positioned 5.4 mm from the skimmer, the intensity of background gas ions generated in the transmission chamber decreased to 1/506, while the intensity of the trichloroethylene ion was maintained at half that without the baffle. The intensities of chlorinated hydrocarbon ions were enhanced by 9-fold compared with the SPI mode when an RF voltage was further applied to the baffle electrode, under which the dominant ionization process was Penning ionization (PenI). Surprisingly, the intensities of chlorinated hydrocarbon ions did not decrease but increased by up to 126% compared to those without the baffle. Simulation of the electric field distribution and electron kinetic energy highlights that the precise overlap of the ion generation region and efficient transmission region plays a pivotal role in the regulation of spatially confined PenI toward sensitivity improvement. This approach has achieved limits of detection down to sub-pptv, even for molecules with ionization energies higher than the photon energy.
- 15 July 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (29) , 21157-21164
Spatially Confined Photoinduced Penning Ionization for Highly Sensitive Mass Spectrometry
In vacuum ultraviolet (VUV) lamp-based photoionization mass spectrometry (PI-MS), the axially mounted configuration exhibits higher sensitivity due to a longer light absorption path. However, VUV light irradiation of the metal surfaces within the transmission chamber induces photoelectron emission; excessive background gas ions are generated via photoelectron ionization under the radio frequency (RF) electric field, which affects the quantitative performance and repeatability of PI-MS, especially for deuterium lamps with a higher photon flux. In this study, a size- and position-adjustable baffle electrode was integrated into the ionization chamber to reduce the light leakage into the transmission chamber. For a 3 mm-diameter baffle positioned 5.4 mm from the skimmer, the intensity of background gas ions generated in the transmission chamber decreased to 1/506, while the intensity of the trichloroethylene ion was maintained at half that without the baffle. The intensities of chlorinated hydrocarbon ions were enhanced by 9-fold compared with the SPI mode when an RF voltage was further applied to the baffle electrode, under which the dominant ionization process was Penning ionization (PenI). Surprisingly, the intensities of chlorinated hydrocarbon ions did not decrease but increased by up to 126% compared to those without the baffle. Simulation of the electric field distribution and electron kinetic energy highlights that the precise overlap of the ion generation region and efficient transmission region plays a pivotal role in the regulation of spatially confined PenI toward sensitivity improvement. This approach has achieved limits of detection down to sub-pptv, even for molecules with ionization energies higher than the photon energy.
- 1 April 2026
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 148 (15) , 15873-15882
Resolving Solution-Synthesized Graphyne-Graphdiyne Macromolecules at the Angstrom Level
Syntheses of low-dimensional macromolecules with increasing size and complexity in solution pose substantial challenges in terms of their precise structural characterization. Electrospray ionization coupled with scanning tunneling microscopy (ESI-STM) has emerged as a promising tool for the characterization of these nonsublimable macromolecules in real space. However, the weak ionization of such macromolecules and the three-dimensional configuration of the attached solubilizing groups severely impede high-resolution STM imaging. In this work, we synthesized a series of graphyne-graphdiyne concentric macrocycles with triphenylamine groups to enhance the ionization efficiency, which in turn ensures the sample cleanliness for STM characterization. To tackle imaging interference from solubilizing groups, single-molecule tip manipulation and large-scale bromine-assisted thermal treatment were developed for alkoxy and/or alkyl chain removal, enabling the acquisition of unprecedented bond-resolving structural images and angstrom-resolution frontier molecular orbital maps. Our methods resolve the long-standing dilemma between the solubility requirements of solution synthesis and the molecular planarization demands of high-resolution STM characterization, pushing the resolution limit of macromolecules to the angstrom level.
- 1 April 2026
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 148 (15) , 15873-15882
Resolving Solution-Synthesized Graphyne-Graphdiyne Macromolecules at the Angstrom Level
Syntheses of low-dimensional macromolecules with increasing size and complexity in solution pose substantial challenges in terms of their precise structural characterization. Electrospray ionization coupled with scanning tunneling microscopy (ESI-STM) has emerged as a promising tool for the characterization of these nonsublimable macromolecules in real space. However, the weak ionization of such macromolecules and the three-dimensional configuration of the attached solubilizing groups severely impede high-resolution STM imaging. In this work, we synthesized a series of graphyne-graphdiyne concentric macrocycles with triphenylamine groups to enhance the ionization efficiency, which in turn ensures the sample cleanliness for STM characterization. To tackle imaging interference from solubilizing groups, single-molecule tip manipulation and large-scale bromine-assisted thermal treatment were developed for alkoxy and/or alkyl chain removal, enabling the acquisition of unprecedented bond-resolving structural images and angstrom-resolution frontier molecular orbital maps. Our methods resolve the long-standing dilemma between the solubility requirements of solution synthesis and the molecular planarization demands of high-resolution STM characterization, pushing the resolution limit of macromolecules to the angstrom level.
- 28 March 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (13) , 6976-6983
Miniature Thermoelectric Cooler for Long-Term Stable Dehydration for On-Site Breath Analysis by Direct Inlet Photoionization Ion Mobility Spectrometry and Mass Spectrometry
Rapid and highly frequent measurements of exhaled breath hold significant value for disease diagnosis and exposure assessments. Direct inlet mass spectrometry and ion mobility spectrometry demonstrate great potential for on-site breath analysis, but their accuracy and sensitivity are notably affected by the high humidity in the breath samples. A miniature and continuous dehydration device based on dual-switching thermoelectric cold traps has been developed to efficiently reduce the humidity of breath gas from saturation to relative humidity of 4.3%, and a subcooling compensation method was adopted to eliminate the humidity fluctuations when switching the two cold traps to remove the condensed water in the trap, which could achieve a stable outlet humidity with RSD of 8.2% regardless of inlet humidity variations. The performance and profits of the miniature dehydration device for on-site analysis of breath samples have been tested by coupling with direct inlet photoionization ion mobility spectrometry and time-of-flight mass spectrometry. Trace breath acetone could be directly measured, and its concentration profiles over an 8 h period in fasting volunteers could be continuously monitored every 30 s. Furthermore, the m/z peaks from chlorinated hydrocarbons in exhaled breath samples were clearly identified after passing the dehydration device, which can be used for an occupational health assessment of the widely used halocarbon solvents.
- 28 March 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (13) , 6976-6983
Miniature Thermoelectric Cooler for Long-Term Stable Dehydration for On-Site Breath Analysis by Direct Inlet Photoionization Ion Mobility Spectrometry and Mass Spectrometry
Rapid and highly frequent measurements of exhaled breath hold significant value for disease diagnosis and exposure assessments. Direct inlet mass spectrometry and ion mobility spectrometry demonstrate great potential for on-site breath analysis, but their accuracy and sensitivity are notably affected by the high humidity in the breath samples. A miniature and continuous dehydration device based on dual-switching thermoelectric cold traps has been developed to efficiently reduce the humidity of breath gas from saturation to relative humidity of 4.3%, and a subcooling compensation method was adopted to eliminate the humidity fluctuations when switching the two cold traps to remove the condensed water in the trap, which could achieve a stable outlet humidity with RSD of 8.2% regardless of inlet humidity variations. The performance and profits of the miniature dehydration device for on-site analysis of breath samples have been tested by coupling with direct inlet photoionization ion mobility spectrometry and time-of-flight mass spectrometry. Trace breath acetone could be directly measured, and its concentration profiles over an 8 h period in fasting volunteers could be continuously monitored every 30 s. Furthermore, the m/z peaks from chlorinated hydrocarbons in exhaled breath samples were clearly identified after passing the dehydration device, which can be used for an occupational health assessment of the widely used halocarbon solvents.
- 26 February 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (9) , 4998-5007
Structural Annotation Method for Locating sn- and C═C Positions of Lipids Using Liquid Chromatography–Electron Impact Excitation of Ions from Organics (EIEIO)–Mass Spectrometry
Definitive structural elucidation of lipids is pivotal for unraveling the functions of lipids in biological systems. Despite advancements in mass spectrometry (MS) for lipid analysis, challenges in annotation scope and efficiency remain, especially in resolving isomers. Herein, we introduce an optimized method using liquid chromatography coupled with electron impact excitation of ions from organic tandem mass spectrometry (LC-EIEIO-MS/MS) for comprehensive analysis and structural annotation of lipids. This approach integrates a six-step analytical protocol for precise lipid annotation, including (1) extracting MS information, (2) classifying lipids, (3) aligning sum composition, (4) determining sn-positions, (5) locating C═C positions, and (6) ascertaining annotation levels. In analyzing 34 lipid standards spiked into serum, our method achieved 100% and 82.4% annotation accuracy at the sn- and C═C isomer levels, respectively, compared to 26.5% and 0% in the CID mode using MS-DIAL. A total of 1312 sn-positions and 1033 C═C locations of lipids were annotated in quality control plasma pooled from healthy individuals and patients with Alzheimer's disease. The isomers of lipids revealed more pronounced differences between the healthy and diseased groups compared to the sum compositions of the lipids. Overall, the LC-EIEIO-MS/MS approach provides a comprehensive profiling and efficient annotation method for lipidomics, promising to shed new light on lipid-related biological pathways and disease mechanisms.
- 26 February 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (9) , 4998-5007
Structural Annotation Method for Locating sn- and C═C Positions of Lipids Using Liquid Chromatography–Electron Impact Excitation of Ions from Organics (EIEIO)–Mass Spectrometry
Definitive structural elucidation of lipids is pivotal for unraveling the functions of lipids in biological systems. Despite advancements in mass spectrometry (MS) for lipid analysis, challenges in annotation scope and efficiency remain, especially in resolving isomers. Herein, we introduce an optimized method using liquid chromatography coupled with electron impact excitation of ions from organic tandem mass spectrometry (LC-EIEIO-MS/MS) for comprehensive analysis and structural annotation of lipids. This approach integrates a six-step analytical protocol for precise lipid annotation, including (1) extracting MS information, (2) classifying lipids, (3) aligning sum composition, (4) determining sn-positions, (5) locating C═C positions, and (6) ascertaining annotation levels. In analyzing 34 lipid standards spiked into serum, our method achieved 100% and 82.4% annotation accuracy at the sn- and C═C isomer levels, respectively, compared to 26.5% and 0% in the CID mode using MS-DIAL. A total of 1312 sn-positions and 1033 C═C locations of lipids were annotated in quality control plasma pooled from healthy individuals and patients with Alzheimer's disease. The isomers of lipids revealed more pronounced differences between the healthy and diseased groups compared to the sum compositions of the lipids. Overall, the LC-EIEIO-MS/MS approach provides a comprehensive profiling and efficient annotation method for lipidomics, promising to shed new light on lipid-related biological pathways and disease mechanisms.
- 8 July 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (31) , 5412-5418
Selective measurement of Cl2 and HCl based on dopant-assisted negative photoionization ion mobility spectrometry combined with semiconductor cooling
This study achieves selective detection of Cl2 and HCl by combining DANP-IMS with semiconductor cooling device, overcoming the traditional challenges of IMS in distinguishing between these two gases.
- 8 July 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (31) , 5412-5418
Selective measurement of Cl2 and HCl based on dopant-assisted negative photoionization ion mobility spectrometry combined with semiconductor cooling
This study achieves selective detection of Cl2 and HCl by combining DANP-IMS with semiconductor cooling device, overcoming the traditional challenges of IMS in distinguishing between these two gases.
- 16 November 2023
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 59 (99) , 14636-14648
Liquid metal catalyzed chemical vapor deposition towards morphology engineering of 2D epitaxial heterostructures
The past decades have witnessed significant advancements in the growth of two-dimensional (2D) materials, offering a wide range of potential applications in the fields of electronics, optoelectronics, energy storage, sensors, catalysis, and biomedical treatments. Epitaxial heterostructures based on 2D materials, including vertical heterostructures, lateral structures, and superlattices, have emerged as novel material systems to manipulate the intrinsic properties and unlock new functionalities. Therefore, the development of controllable preparation methods for tailored epitaxial heterostructures serves as a fundamental basis for extensive property investigation and further application exploration. However, this pursuit presents formidable challenges due to the incomplete understanding of growth mechanisms and limited designable strategies. Chemical vapor deposition (CVD) is deemed as a promising and versatile platform for the controlled synthesis of 2D materials, especially with regard to achieving lattice matching, a critical factor in epitaxial growth. Consequently, CVD holds potential to overcome these hurdles. In this Feature Article, we present our recent breakthroughs in the controllable preparation of 2D epitaxial heterostructures using CVD. Our focus revolves around the processes of morphology engineering, interface engineering, size and density engineering, and striking the delicate balance between growth and etching. Using molten metals or alloys as primary catalysts, we have achieved remarkable control over the fabrication of graphene/hexagonal boron nitride (hBN) super-ordered arrays, enabled multistage etching of graphene/hBN heterostructures, and successfully realized the construction of graphene/MXene heterostructures. Furthermore, our research endeavors encompass both bottom-up and top-down fabrication methods, offering a novel perspective on the synthesis of 2D epitaxial heterostructures. The resulting products hold immense potential for enhancing the efficiency of critical reactions such as oxygen reduction, CO2 reduction, and hydrogen evolution reactions. By presenting our methodologies for obtaining 2D epitaxial heterostructures through CVD, we aspire to inspire fellow researchers in this field to devise more feasible and controllable fabrication techniques while also fostering the exploration of diverse heterostructure configurations. Together, these advancements will undoubtedly pave the way for further breakthroughs in atomic manufacturing and novel applications.
- 16 November 2023
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 59 (99) , 14636-14648
Liquid metal catalyzed chemical vapor deposition towards morphology engineering of 2D epitaxial heterostructures
The past decades have witnessed significant advancements in the growth of two-dimensional (2D) materials, offering a wide range of potential applications in the fields of electronics, optoelectronics, energy storage, sensors, catalysis, and biomedical treatments. Epitaxial heterostructures based on 2D materials, including vertical heterostructures, lateral structures, and superlattices, have emerged as novel material systems to manipulate the intrinsic properties and unlock new functionalities. Therefore, the development of controllable preparation methods for tailored epitaxial heterostructures serves as a fundamental basis for extensive property investigation and further application exploration. However, this pursuit presents formidable challenges due to the incomplete understanding of growth mechanisms and limited designable strategies. Chemical vapor deposition (CVD) is deemed as a promising and versatile platform for the controlled synthesis of 2D materials, especially with regard to achieving lattice matching, a critical factor in epitaxial growth. Consequently, CVD holds potential to overcome these hurdles. In this Feature Article, we present our recent breakthroughs in the controllable preparation of 2D epitaxial heterostructures using CVD. Our focus revolves around the processes of morphology engineering, interface engineering, size and density engineering, and striking the delicate balance between growth and etching. Using molten metals or alloys as primary catalysts, we have achieved remarkable control over the fabrication of graphene/hexagonal boron nitride (hBN) super-ordered arrays, enabled multistage etching of graphene/hBN heterostructures, and successfully realized the construction of graphene/MXene heterostructures. Furthermore, our research endeavors encompass both bottom-up and top-down fabrication methods, offering a novel perspective on the synthesis of 2D epitaxial heterostructures. The resulting products hold immense potential for enhancing the efficiency of critical reactions such as oxygen reduction, CO2 reduction, and hydrogen evolution reactions. By presenting our methodologies for obtaining 2D epitaxial heterostructures through CVD, we aspire to inspire fellow researchers in this field to devise more feasible and controllable fabrication techniques while also fostering the exploration of diverse heterostructure configurations. Together, these advancements will undoubtedly pave the way for further breakthroughs in atomic manufacturing and novel applications.
- 25 October 2023
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 47 (45) , 20703-20707
Liquid Cu–Zn catalyzed growth of graphene single-crystals
The controllable synthesis of millimeter-sized single-crystal monolayer graphene on a liquid Cu–Zn alloy by suppressing nucleation is reported.
- 25 October 2023
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 47 (45) , 20703-20707
Liquid Cu–Zn catalyzed growth of graphene single-crystals
The controllable synthesis of millimeter-sized single-crystal monolayer graphene on a liquid Cu–Zn alloy by suppressing nucleation is reported.
- 2 August 2023
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 394, 134402
A miniaturized photodiode-based chemiluminescence sensor for measurement of fractional exhaled nitric oxide
- 2 August 2023
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 394, 134402
A miniaturized photodiode-based chemiluminescence sensor for measurement of fractional exhaled nitric oxide