LDLokesh Kumar Dewangan

Lokesh Kumar Dewangan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lokesh Kumar Dewangan has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Interaction Metric Based Exhaustive Modal Analysis of Large-Scale Power Systems with Hybrid EMT-Phasor Modeling

    by Aditya Pandey, Lokesh Kumar Dewangan, Kouki Mohamed

    Modern power systems are increasingly dominated by renewable energy sources (RES) interfaced through power electronic-based Power Park Modules (PPMs). Unlike synchronous generators, PPMs possess fast-switching dynamics and low mechanical inertia, introducing high-frequency oscillations absent in conventional grids. When located near transmission lines, these dynamics can strongly influence system behavior through complex converter–network interactions, affecting both local and global stability. Accurate representation of such interactions requires a hybrid modeling framework combining electromagnetic transient (EMT) models for detailed converter and line dynamics with phasor-domain models for the broader grid. However, integrating EMT subsystems greatly increases model dimensionality, making conventional modal analysis computationally demanding. To address this challenge, this paper proposes a scalable modal analysis methodology for hybrid EMT–phasor systems based on Selective Modal Analysis (SMA). The method efficiently identifies dominant converter–network interaction modes with reduced computational effort. The proposed approach is validated on a modified IEEE 39-bus system incorporating PPM-based renewable generation, demonstrating its accuracy and effectiveness for stability assessment in large-scale converter-dominated grids.

  • Open Access

    Interaction Assessment of Converter Interfaced Power Systems Using Proximal Eigenvalue Displacement Approach

    by Lokesh Kumar Dewangan, Francesco Giacomo Puricelli, Jef Beerten

    With the growing integration of converter-interfaced generating units in power systems, interactions between converters and grids have been observed across both low and highfrequency ranges, resulting from the diverse dynamics of these converters. Moreover, incorporating the complex dynamic model of converters, which involves a large number of state variables, increases the computational burden when using conventional methods to identify unstable and interaction modes. These modes are also influenced by the parameters of both converters and networks, necessitating numerous time-consuming re-computations of all eigenvalues for parametric variation analysis in large power systems. To address these challenges, this paper proposes a method that utilizes closely located open-loop modes and their displacement from open-loop to closed-loop modes to selectively identify interaction modes within power systems. The proposed method leverages the open-loop subsystem eigenvalues and the interconnections between state variables of different subsystems to determine the closed-loop eigenvalue using a second-order eigenvalue approximation, thereby avoiding the need for the calculation of all eigenvalues of the entire system. The interaction information is then used to obtain a reduced-order eigenvector approximation to improve the computation time as compared to the full-order system. The identified interaction modes and corresponding computation time using the proposed method are compared with the traditional modal participation method. The proposed method provides an efficient approach to identifying interactions between converters and the power system.

  • Robust Decoupled Outer-Control Design for Single VSC and HVDC Grid With Controller Weak AC System Interconnection

    by Lokesh Dewangan, Himanshu J. Bahirat

    With the increase in number of VSC based HVDC systems, it is inevitable that there would be interconnections with weak ac grids. The paper presents the analytical basis for identifying coupling in the power loops which is dependent on grid inductance and operating point by utilizing the impedance based modeling technique. The formulation is used to define an inverse-based decoupling outer-loop controller for VSC-HVDC system. The concept is extended to HVDC grids and it is shown that the gains obtained using simple inverse may lead to instability. Robust controller tuning with pole-placement and minimization of $H_\infty$ norm is presented for HVDC grids, which form a restricted feedback system. The results show that the proposed method of decoupling results in effective decoupling of the power loops over a large range of grid inductance values as compared to that with traditional vector control. The system stability is also maintained over a large range of grid inductance values and PLL gains when a sudden variation of parameters is considered. The stability margins can be enhanced by pole-placement. The observations from the small-signal models are confirmed using detailed time-domain simulations. The proposal is expected to be useful in controller design for single VSC as well as HVDC grids, especially, during planing stage.


  • Controller Interaction and Stability Margins in Mixed SCR MMC-Based HVDC Grid

    by Lokesh Kumar Dewangan, Himanshu J. Bahirat

    Using HVDC grids for interconnection of grids across countries posses questions regarding interactions and stability. Important aspects that may be considered are the different SCR values of the corresponding ac grids and outages. The analysis of such mixed SCR will be time-consuming since; detailed models and multiple simulations of the entire system will be required in order to develop a complete understanding of the modes of interactions and existing stability margins. The paper presents an analysis technique that uses the mode identification and participation factor augmented with eigen-sensitivity to analyze modes of interactions and stability margins of the HVDC grids when system parameters and controller gains are varied. The method does not require detailed switched models to be developed. The paper also proposes an adaptive control technique which results in a reduction of interactions and prevents instability when system operating conditions are changed. The results obtained using the proposed analysis technique are verified with a detailed time-domain simulation of the HVDC grid. The interaction modes and participation of states are dependent on the converter operation modes, loading characteristics, SCR values, PLL gains and loading conditions.


  • Open Access

    Analysis and Identification of Controller Interaction and Limitation in VSC-HVDC Grid

    by Lokesh Dewangan, Himanshu J. Bahirat

    With the advancement of the idea of the HVDC grid, it becomes imperative to study the interaction of controller and identification of modes of oscillations. The paper presents the complete model of HVDC grid with detailed modeling of controllers, phase lock loops (PLLs), dc grid and the ac systems. An analytical method combining participation factors and Eigen-sensitivity is proposed to determine the relative stability of the HVDC grid with respect to parameter variations. The paper also proposes the identification of inter-area and controller interaction modes on the basis of the nearest distance between the eigenvalues using the derived sensitivity indices. The critical parameters are varied in a mixed short circuit ratio (SCR) HVDC grid and predictions from the analysis method are confirmed with time-domain simulation in PSCAD simulator