Ahmed Galal Eldin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ahmed Galal Eldin has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Abd El-Galil E. Amr
Applied Organic Chemistry Department, National Research Center, Dokki, Giza 12622, Egypt
3 shared publications - Ayman Helmi Kamel
Department of Chemistry, College of Science, University of Bahrain
3 shared publications - Mohamed A. Al- Omar
Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
2 shared publications - Saad S. M. Hassan
Chemistry Department, Faculty of Science, Ain Shams University, Abbasia, Cairo 11566, Egypt
2 shared publications - Nagy M. Khalifa
Pharmaceutical Chemistry Department, Drug Exploration & Development Chair (DEDC), College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
1 shared publication - Saad S. M. Hassan
Department of Chemistry, Faculty of Science, Ain Shams University, Cairo, Egypt
1 shared publication
Latest Publications
- Open Access
Improved Solid-Contact Nitrate Ion Selective Electrodes Based on Multi-Walled Carbon Nanotubes (MWCNTs) as an Ion-to-Electron Transducer
Possible improvement of the performance characteristics, reliability and selectivity of solid-contact nitrate ion-selective electrodes (ISE) (SC/NO3−-ISE) is attained by the application of a nitron-nitrate (Nit+/NO3−) ion association complex and inserting multi-walled carbon nanotubes (MWCNTs) as an ion-to-electron transducer between the ion sensing membrane (ISM) and the electronic conductor glassy carbon (GC) substrate. The potentiometric performance of the proposed electrode revealed a Nernstian slope −55.1 ± 2.1 (r² = 0.997) mV/decade in the range from 8.0 × 10−8–1 × 10−2 M with a detection limit of 2.8 × 10−8 (1.7 ng/mL). Selectivity, repeatability and reproducibility of the proposed sensors were considerably improved as compared to the coated disc electrode (GC/NO3−-ISE) without insertion of a MWCNT layer. Short-term potential stability and capacitance of the proposed sensors were tested using a current-reversal chronopotentiometric technique. The potential drift in presence of a MWCNT layer decreased from 167 μVs−1 (i.e., in absence of MWCNTs) to 16.6 μVs−1. In addition, the capacitance was enhanced from 5.99 μF (in absence of MWCNTs) to 60.3 μF (in the presence of MWCNTs). The presented electrodes were successfully applied for nitrate determination in real samples with good accuracy.
Open AccessImproved Solid-Contact Nitrate Ion Selective Electrodes Based on Multi-Walled Carbon Nanotubes (MWCNTs) as an Ion-to-Electron Transducer
Possible improvement of the performance characteristics, reliability and selectivity of solid-contact nitrate ion-selective electrodes (ISE) (SC/NO3−-ISE) is attained by the application of a nitron-nitrate (Nit+/NO3−) ion association complex and inserting multi-walled carbon nanotubes (MWCNTs) as an ion-to-electron transducer between the ion sensing membrane (ISM) and the electronic conductor glassy carbon (GC) substrate. The potentiometric performance of the proposed electrode revealed a Nernstian slope −55.1 ± 2.1 (r² = 0.997) mV/decade in the range from 8.0 × 10−8–1 × 10−2 M with a detection limit of 2.8 × 10−8 (1.7 ng/mL). Selectivity, repeatability and reproducibility of the proposed sensors were considerably improved as compared to the coated disc electrode (GC/NO3−-ISE) without insertion of a MWCNT layer. Short-term potential stability and capacitance of the proposed sensors were tested using a current-reversal chronopotentiometric technique. The potential drift in presence of a MWCNT layer decreased from 167 μVs−1 (i.e., in absence of MWCNTs) to 16.6 μVs−1. In addition, the capacitance was enhanced from 5.99 μF (in absence of MWCNTs) to 60.3 μF (in the presence of MWCNTs). The presented electrodes were successfully applied for nitrate determination in real samples with good accuracy.
- Open Access
Single-Walled Carbon Nanotubes (SWCNTs) as Solid-Contact in All-Solid-State Perchlorate ISEs: Applications to Fireworks and Propellants Analysis
Herein, we present reliable, robust, stable, and cost-effective solid-contact ion-selective electrodes (ISEs) for perchlorate determination. Single-walled carbon nanotubes (SWCNTs) were used as solid-contact material and indium (III) 5, 10, 15, 20-(tetraphenyl) porphyrin chloride (InIII-porph) as an ion carrier. The sensor exhibited an improved sensitivity towards ClO4− ions with anionic slope of −56.0 ± 1.1 (R2 = 0.9998) mV/decade over a linear range 1.07 × 10−6 – 1.0 × 10−2 M and detection limit of 1.8 × 10−7 M. The short-term potential stability and the double-layer capacitance were measured by chronopotentiometric and electrochemical impedance spectroscopy (EIS) measurements, respectively. The sensor is used for ClO4− determination in fireworks and propellant powders. The results fairly agree with data obtained by ion chromatography.
Open AccessSingle-Walled Carbon Nanotubes (SWCNTs) as Solid-Contact in All-Solid-State Perchlorate ISEs: Applications to Fireworks and Propellants Analysis
Herein, we present reliable, robust, stable, and cost-effective solid-contact ion-selective electrodes (ISEs) for perchlorate determination. Single-walled carbon nanotubes (SWCNTs) were used as solid-contact material and indium (III) 5, 10, 15, 20-(tetraphenyl) porphyrin chloride (InIII-porph) as an ion carrier. The sensor exhibited an improved sensitivity towards ClO4− ions with anionic slope of −56.0 ± 1.1 (R2 = 0.9998) mV/decade over a linear range 1.07 × 10−6 – 1.0 × 10−2 M and detection limit of 1.8 × 10−7 M. The short-term potential stability and the double-layer capacitance were measured by chronopotentiometric and electrochemical impedance spectroscopy (EIS) measurements, respectively. The sensor is used for ClO4− determination in fireworks and propellant powders. The results fairly agree with data obtained by ion chromatography.
- Open Access
Screen-printed Microsensors Using Polyoctyl-thiophene (POT) Conducting Polymer As Solid Transducer for Ultratrace Determination of Azides
Two novel all-solid-state potentiometric sensors for the determination of azide ion are prepared and described here for the first time. The sensors are based on the use of iron II-phthalocyanine (Fe-PC) neutral carrier complex and nitron-azide ion-pair complex (Nit-N3−) as active recognition selective receptors, tetradodecylammonium tetrakis(4-chlorophenyl) borate (ETH 500) as lipophilic cationic additives and poly(octylthiophene) (POT) as the solid contact material on carbon screen-printed devices made from a ceramic substrate. The solid-contact material (POT) is placed on a carbon substrate (2 mm diameter) by drop-casting, followed, after drying, by coating with a plasticized PVC membrane containing the recognition sensing complexes. Over the pH range 6-9, the sensors display fast (< 10 s), linear potentiometric response for 1.0 × 10−2–1.0 × 10−7 M azide with low detection limit of 1.0 × 10−7 and 7.7 × 10−8 M (i.e., 6.2–4.8 ng/ml) for Fe-PC/POT/and Nit-N3−/POT based sensors, respectively. The high potential stability and sensitivity of the proposed sensors are confirmed by electrochemical impedance spectroscopy (EIS) and constant-current chronopotentiometry measurement techniques. Strong membrane adhesion and absence of delamination of the membrane, due to possible formation of a water film between the recognition membranes and the electron conductor are also verified. The proposed sensors are successfully applied for azide quantification in synthetic primer mixture samples. Advantages offered by these sensors are the robustness, ease of fabrication, simple operation, stable potential response, high selectivity, good sensitivity and low cost.
Open AccessScreen-printed Microsensors Using Polyoctyl-thiophene (POT) Conducting Polymer As Solid Transducer for Ultratrace Determination of Azides
Two novel all-solid-state potentiometric sensors for the determination of azide ion are prepared and described here for the first time. The sensors are based on the use of iron II-phthalocyanine (Fe-PC) neutral carrier complex and nitron-azide ion-pair complex (Nit-N3−) as active recognition selective receptors, tetradodecylammonium tetrakis(4-chlorophenyl) borate (ETH 500) as lipophilic cationic additives and poly(octylthiophene) (POT) as the solid contact material on carbon screen-printed devices made from a ceramic substrate. The solid-contact material (POT) is placed on a carbon substrate (2 mm diameter) by drop-casting, followed, after drying, by coating with a plasticized PVC membrane containing the recognition sensing complexes. Over the pH range 6-9, the sensors display fast (< 10 s), linear potentiometric response for 1.0 × 10−2–1.0 × 10−7 M azide with low detection limit of 1.0 × 10−7 and 7.7 × 10−8 M (i.e., 6.2–4.8 ng/ml) for Fe-PC/POT/and Nit-N3−/POT based sensors, respectively. The high potential stability and sensitivity of the proposed sensors are confirmed by electrochemical impedance spectroscopy (EIS) and constant-current chronopotentiometry measurement techniques. Strong membrane adhesion and absence of delamination of the membrane, due to possible formation of a water film between the recognition membranes and the electron conductor are also verified. The proposed sensors are successfully applied for azide quantification in synthetic primer mixture samples. Advantages offered by these sensors are the robustness, ease of fabrication, simple operation, stable potential response, high selectivity, good sensitivity and low cost.