WSWeiheng Shao

Weiheng Shao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Weiheng Shao has a total of 189 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Metal Surface Current Density Fast Imaging via a Hx and Hy Simultaneous Near‐Field Probing System

    by Yusong Xie, Jian Qiu, Yunlei Shi, E Shao, Xin Zhou, Peng Han, Hui Li, Weiheng Shao

    This paper presents a fast metal surface current density acquisition technology. Different from traditional current imaging algorithms using the Biot‐Savart law with two magnetic fields measured separately, the proposed technology employs a enhanced current density imaging method with horizontal dual magnetic fields and simultaneous probing system. The proposed technology is capable of quickly obtaining and simultaneously and at the same location, which can improve the accuracy of dual magnetic field collaborative measurement, avoiding errors caused by changing single‐component and probes. Furthermore, this technology enables non‐contact detection of current within a specific frequency band using a network analyzer. Simulation and experimental results demonstrate that the method can rapidly acquire the current distribution on the surface of the device under test, with imaging speed nearly doubled compared to single‐probe measurement, while providing reconstructed current results superior to those of Fourier methods.

  • An Active Tangential Electric Field Probe for Switching Noise Diagnosis in Power Modules

    by Zhiqiang Yi, Linyan Li, Shuaibing Guo, Zhanjun Huang, Litao Ruan, Hui Li, Zhizhe Wang, E. Shao, Yunlei Shi, Maning Zhang, et al.

    Wide-band-gap semiconductors have brought about a revolution in the speed of power electronic switching, but electromagnetic interference has become a new burden. In this paper, we present a tangential electric field probe dedicated to the diagnosis of power electron electromagnetic noise. The proposed probe adopts four-layer printed circuit board technology and can measure the Ex or Ey of the tangential electric field. The detection structure adopts enhanced dipole and differential amplifier with a 20 dB gain to improve the detection sensitivity. Through the measurement results, the proposed probe can operate from 100 kHz to 4.6 GHz, which is just right for power circuits. Its unwanted field suppression is above 10 dB, and maximum frequency response reach -25.8 dB at 0.65 GHz. The measurement results of a typical GaN power module demonstrate the effectiveness of the proposed probe.

  • A Fault Diagnosis Method Based on Adaptive Threshold Judgment in Zero-Crossing Interval for Aviation Three-Phase Inverter

    by Zhanjun Huang, Jun Xie, Maning Zhang, Kang Hu, An Zhang, Weiheng Shao, Yanning Xiong

    Most existing inverter fault diagnosis methods simplify actual fault conditions and operating scenarios for research expediency. However, their diagnostic reliability is compromised when confronted with such as non-simultaneous secondary switch faults or multiple complex operating conditions. To address these issues, this paper proposes a novel open-circuit fault diagnosis method. First, the three-phase current is measured, and a mean filtering is applied to enhance the waveform smoothness. Next, a zero-crossing-driven interval determination method is proposed for the current positive-half and negative-half. An adaptive threshold is then calculated in each interval, and the comparison between the current and this threshold effectively captures the loss of the waveform. Finally, a mapping from the fault signature vector to the fault mode is established to precisely localize the fault switch. Compared to existing advanced methods, the proposed approach can effectively handle the feature aberrance caused by system feedback. It also accurately identifies non-simultaneous secondary switch fault and demonstrates diagnostic consistency in various load scenarios. Experimental results, comparisons, and analyses confirm the superiority of the proposed method.


  • Open Access

    Time-Domain Current Waveform Reconstruction of a Printed Trace via a Locally Enhanced Active H-Field Probing System

    by Zhiqiang Yi, Shuaibing Guo, Xiao Luo, Hui Li, Litao Ruan, Xinxin Tian, Weiheng Shao

    Time-domain current signal reconstruction is crucial for conducted electromagnetic interference measurements and signal diagnostics. Meanwhile, active magnetic field (H-field) probes significantly improve time-domain measurement sensitivity. This paper evaluates the effectiveness of the time-domain current waveform reconstruction technology on a printed trace via a locally enhanced active H-field probing system, and assesses algorithm accuracy and robustness by simulating the frequency response curves with different shapes. Comparative results demonstrate that the broadband reconstruction technology outperforms conventional integration methods in waveform fidelity when using the enhanced active H-field probe. The simulation results show that the broadband time-domain reconstruction technology can adapt to complex fluctuations in frequency response curve and provide relatively high-precision time-domain reconstruction results.

  • Open Access

    Combined effect of total ionizing dose and electromagnetic pulse on bipolar junction transistor

    by Meiqing Zhong, Cui Meng, Yinong Liu, Chicheng Liu, Lanfeng Yuan, Xinfei Liu, Lin Wen, Qi Guo, Rui Ding, Weiheng Shao

    Electronic systems in complex radiation environments, such as space applications and nuclear power plants, face simultaneous threats from the cumulative damage of Total Ionizing Dose (TID) and the transient disturbances of Electromagnetic Pulse (EMP). The potential combined effect between these two phenomena poses a severe challenge to device reliability. This paper investigates the combined effect of TID and single-pulse EMP on Bipolar Junction Transistor (BJT) through a systematic approach involving 60Co γ irradiation experiments and electrical fast transient injection experiments, supported by physical mechanism analysis using TCAD simulations. Both experimental and simulation results demonstrate a significant polarity dependence in the combined effect: TID significantly shortens the transient response duration when a positive polarity pulse is injected into the base, or a negative polarity pulse is injected into the collector. This paper systematically analyzes the mechanism of the combined effect of TID and single-pulse EMP on BJTs, providing a crucial theoretical basis and design guidance for the radiation hardening design in extreme radiation environments.


  • Calibration Based on De-Embedding for an Asymmetric Differential Magnetic Field Probing System

    by Litao Ruan, Weiheng Shao, Xinxin Tian, Hui Li, Shan Xue, Xin Cheng, Jianfeng Li

    Calibration of differential magnetic field probes is essential to ensure accuracy in near-field measurements. However, in practical applications, the asymmetry problem and the embedded part of the calibrator will affect the accuracy of broadband calibration. To address these challenges, a combined calibration method, termed the non-rotating de-embedding calibration method (NRDCM), is proposed for an asymmetric differential magnetic field probing system in this paper. The asymmetry problem of the differential magnetic field probing system is corrected by the proposed method. Furthermore, the attenuation and reflection introduced by the calibrators are also mitigated by a de-embedding process within the proposed method. Measurement results of the standing wave behavior demonstrate that NRDCM exhibits minimal fluctuation across a frequency range from 100 kHz to 20 GHz, confirming its suitability for asymmetric calibration applications up to 20 GHz.


  • A Radio Frequency Current Reconstruction Method Based on Near-Field Scanning for Noncontact Detection of PCBs

    by Yusong Xie, Jiong Tang, Jian Qiu, Peng Han, Dongmei Liu, Rui Ding, Weiheng Shao, Yangyang Zhou

    In electromagnetic compatibility analysis and non-destructive fault diagnosis of circuits, accurately measuring the radio-frequency current distribution in printed circuit board (PCB) is of critical importance. However, for circuit modules without dedicated test points, non-destructive and direct measurement of in-situ current remains a formidable challenge. Currently, a common alternative approach involves measuring the magnetic field directly above the PCB with a magnetic field probe, and then reconstructing the current distribution on the PCB surface using the Biot-Savart law. Nevertheless, this inversion algorithm typically assumes quasi-static current conditions, and its inversion parameters are often empirically selected. These limitations significantly constrain its applicability in complex radio-frequency (RF) environments. To address this challenge, this work proposes an enhanced Magnetic Current Imaging method specifically designed for reconstructing the RF current distribution on PCBs surfaces. This method leverages the current-magnetic field relationship and employs a regularization technique to constrain current distribution. Additionally, it utilizes a mask-based approach and an extended measurement window to mitigate current artifacts. Finally, its feasibility and accuracy are comprehensively validated through simulations and near-field scanning experiments, demonstrating its robustness and effectiveness even under high-noise conditions.


  • Isolation Characterization for a Multicomponent Electromagnetic Near-Field Probing System

    by Weiheng Shao, Litao Ruan, Jinxin Zhang, Caixu Yu, Xinxin Tian

    Multicomponent electromagnetic probing system, which can detect multicomponents $E_{z}, H_{x}$ , and $H_{y}$ simultaneously, can achieve superior efficiency in nearfield measurement. However, as a typical multichannel measurement system, the isolation between any two measured signals in the multicomponent probing system is not clearly characterized. In this article, a comparative analysis on the isolation characterization methods for multiport multicomponent probing systems is conducted, employing both numerical simulations and experimental measurements. Meanwhile, a novel isolation characterization method is proposed based on the measurement of a two-port symmetric calibrator. Theoretically, by feeding the two-port symmetric calibrator with common mode and differential mode excitations, an ideal induction zone (IDZ), where unwanted field components are suppressed, is constructed for isolation characterization. Different isolation characterization methods are compared by using a typical multicomponent near-field probe, and measurement results demonstrate that the proposed common and differential modes excitation (CDME) method is more accurate, stable, and convenient.

  • A Middle Underfill L-Standard Design for Highly Impedance Continuity in Four-Port Probe De-Embedding Calibration

    by Zhanjun Huang, Hui Li, Litao Ruan, Xinxin Tian, Shan Xue, Jun Luo, Guoguang Lu, Zhizhe Wang, Weiheng Shao

    The calibration of the four-port three-component probe, measuring ${H}_{x}$ , ${H}_{y}$ , and ${E}_{z}$ , is interesting for near-field measurement. At high frequency, calibration errors caused by the frequency response are very distressing. These error reasons include the multiple refection caused by embedded part of the calibrator (first error term) and the single reflection caused by the probe approaching the calibrator (second error term). The first error term has been proven to be eliminated through de-embedding calibration method of two-port probe. However, the second error term cannot be removed by this method, which will cause the impedance discontinuity of calibration process. In this article, a middle underfill L-standard as a calibrator is proposed for a four-port three-component probe de-embedding calibration. The new L-standard design can increase the inductive reactance of transmission structure to resist the capacitive effect of the probe when approaching the calibrator. The results of simulation or measurement show that the new L-standard can improve the impedance continuity by nearly 75.6% with a suitable height. Compared with traditional embedding calibration method of four-port three-component probe, the frequency response after using the new calibrator can improve about $0.7\sim 2.2$ dB, and the ripples caused by embedded part can be eliminated.