Maciej Kozak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maciej Kozak has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Radosław Gordon
Department of Electrical Engineering and Power Electronics, Faculty of Mechatronics and Electrical Engineering, Maritime University of Szczecin, Willowa 2, 71-650 Szczecin, Poland
3 shared publications - Arkadiusz Puszkarek
Faculty of Mechatronics and Electrical Engineering, Maritime University of Szczecin, 70-500 Szczecin, Poland
2 shared publications - Arkadiusz Tomczak
Department of Geodesy and Offshore Survey, Maritime University of Szczecin, 70-500 Szczecin, Poland
2 shared publications - Artur Bejger
Faculty of Marine Engineering, Maritime University of Szczecin, 71-650 Szczecin, Poland
2 shared publications - Kacper Olszański
Faculty of Mechatronics and Electrotechnics, Maritime University of Szczecin, 71-650 Szczecin, Poland
2 shared publications Krzysztof Zawirski
Poznań University of Technology, Poland
2 shared publications
Latest Publications
- Open Access
Implementation of a Sensorless Control System with a Flying-Start Feature for an Asynchronous Machine as a Ship Shaft Generator
Squirrel-cage induction generators often perform better without a mechanical speed sensor. Eliminating an encoder or resolver removes one of the most fragile and failure-prone components, while modern control algorithms can estimate speed with sufficient accuracy. Shaft-mounted sensors are vulnerable to heat, vibration, dust, moisture, and electrical noise; they require precise mounting and additional cabling and typically fail long before the machine itself. In many industrial and marine applications, unplanned shutdowns are more often caused by damaged sensors or cables than by the generator. Unlike sensorless speed-detection methods developed for motoring operation, the proposed approach targets the generator mode, where both phase currents and the DC-link voltage are measured. It uses two indicators: the magnitude and sign of the active current, and the instantaneous rise in DC-link voltage when the converter output frequency matches the machine’s shaft speed. Because active current remains negative over a wide frequency range during start-up, its sign change alone cannot uniquely identify the synchronization point. In generator operation, however, the DC-link capacitor voltage provides an additional criterion: the speed at which power reverses sign, indicated by a change in the sign of the DC-voltage derivative. As the inverter frequency approaches the machine rotational frequency from below, the DC voltage increases, reaches a maximum at maximum slip, and then decreases once the inverter frequency exceeds the machine speed. The article demonstrates how these signals can be used in practice to identify the rotational speed of a squirrel-cage generator.
Open AccessImplementation of a Sensorless Control System with a Flying-Start Feature for an Asynchronous Machine as a Ship Shaft Generator
Squirrel-cage induction generators often perform better without a mechanical speed sensor. Eliminating an encoder or resolver removes one of the most fragile and failure-prone components, while modern control algorithms can estimate speed with sufficient accuracy. Shaft-mounted sensors are vulnerable to heat, vibration, dust, moisture, and electrical noise; they require precise mounting and additional cabling and typically fail long before the machine itself. In many industrial and marine applications, unplanned shutdowns are more often caused by damaged sensors or cables than by the generator. Unlike sensorless speed-detection methods developed for motoring operation, the proposed approach targets the generator mode, where both phase currents and the DC-link voltage are measured. It uses two indicators: the magnitude and sign of the active current, and the instantaneous rise in DC-link voltage when the converter output frequency matches the machine’s shaft speed. Because active current remains negative over a wide frequency range during start-up, its sign change alone cannot uniquely identify the synchronization point. In generator operation, however, the DC-link capacitor voltage provides an additional criterion: the speed at which power reverses sign, indicated by a change in the sign of the DC-voltage derivative. As the inverter frequency approaches the machine rotational frequency from below, the DC voltage increases, reaches a maximum at maximum slip, and then decreases once the inverter frequency exceeds the machine speed. The article demonstrates how these signals can be used in practice to identify the rotational speed of a squirrel-cage generator.
- Open Access
- 11 December 2025
- Published by MDPI AG in Preprints.org
Implementation of a Sensorless Control System with a Flying-Start Feature for an Asynchronous Machine as a Ship’s Shaft Generator
Asynchronous motor drives are often better without a rotational speed sensor because removing the encoder or resolver gets rid of one of the weakest and most troublesome elements of the whole drive system, while modern control algorithms can usually estimate speed with sufficient accuracy for most applications. A shaft encoder or resolver is a delicate device mounted on the motor shaft, exposed to heat, vibration, dust, moisture and electrical noise. It needs precise mechanical mounting, alignment, extra cabling and connectors, and it ages or fails much faster than the motor itself. In many industrial and marine installations, unplanned stoppages are caused more by damaged encoders or their cables than by real motor failures. Another issue connected with sensorless operation is a flying start (also called flying restart, spin-catch or catch-on-the-fly) which is a special function of an inverter drive that allows it to safely take control of an induction machine that is already rotating, instead of assuming the motor is at standstill. With flying start mode enabled, the drive first looks for the actual speed and direction of the motor before it builds up torque. In practice, it reconnects to the motor with a special search routine: it applies a small voltage pattern, measures the resulting currents and the back EMF, and from these signals estimates the rotating magnetic field and thus the motor’s speed and direction. Once it has locked onto the rotor flux, it adjusts its output frequency and phase so that the stator field “catches” the spinning rotor smoothly. After that, it ramps the speed to the reference value just like in normal operation. The asynchronous generator needs an upgrade in comparison to drive mode of operation which means that startup conditions differ than this used in the motoring mode. This article presents original method of sensorless rotational speed determination and excitement process with use of machine state observer.
- 11 December 2025
- Published by MDPI AG in Preprints.org
Open AccessImplementation of a Sensorless Control System with a Flying-Start Feature for an Asynchronous Machine as a Ship’s Shaft Generator
Asynchronous motor drives are often better without a rotational speed sensor because removing the encoder or resolver gets rid of one of the weakest and most troublesome elements of the whole drive system, while modern control algorithms can usually estimate speed with sufficient accuracy for most applications. A shaft encoder or resolver is a delicate device mounted on the motor shaft, exposed to heat, vibration, dust, moisture and electrical noise. It needs precise mechanical mounting, alignment, extra cabling and connectors, and it ages or fails much faster than the motor itself. In many industrial and marine installations, unplanned stoppages are caused more by damaged encoders or their cables than by real motor failures. Another issue connected with sensorless operation is a flying start (also called flying restart, spin-catch or catch-on-the-fly) which is a special function of an inverter drive that allows it to safely take control of an induction machine that is already rotating, instead of assuming the motor is at standstill. With flying start mode enabled, the drive first looks for the actual speed and direction of the motor before it builds up torque. In practice, it reconnects to the motor with a special search routine: it applies a small voltage pattern, measures the resulting currents and the back EMF, and from these signals estimates the rotating magnetic field and thus the motor’s speed and direction. Once it has locked onto the rotor flux, it adjusts its output frequency and phase so that the stator field “catches” the spinning rotor smoothly. After that, it ramps the speed to the reference value just like in normal operation. The asynchronous generator needs an upgrade in comparison to drive mode of operation which means that startup conditions differ than this used in the motoring mode. This article presents original method of sensorless rotational speed determination and excitement process with use of machine state observer.
- Open Access
Application of Squirrel Cage Generator Control System Utilizing Direct Torque Control Method as the Shaft Generator in a Seagoing Ship
The squirrel cage induction generator or SCIG (Squirrel Cage Induction Generator) belongs to the family of induction machines, which are currently used as the most common electrical machines. The use of power electronic converter systems along with advanced control vector algorithms allows for the implementation of the effective operation of squirrel cage generators in various conditions. Up to now, there are a few practical realizations of squirrel cage generators, which are installed on board the vessels; mostly, these generators act as shaft generators, and it originates from the rules that require self-excitement of main electrical generators, acting as an immediate ready-to-use voltage source. In this article, we present a solution that utilizes an SCIG that operates with varying rotational speed as a shaft generator but can also act as an emergency propeller drive in case of main combustion engine failure. The main achievement of the presented work was the creation of a control table prepared for real-time software of the machine-side inverter. The data for the table were collected during the experimental research, and such a setup allowed us to use a DTC-controlled SCIG as a generator that rotated with variable speed and under changing load.
Open AccessApplication of Squirrel Cage Generator Control System Utilizing Direct Torque Control Method as the Shaft Generator in a Seagoing Ship
The squirrel cage induction generator or SCIG (Squirrel Cage Induction Generator) belongs to the family of induction machines, which are currently used as the most common electrical machines. The use of power electronic converter systems along with advanced control vector algorithms allows for the implementation of the effective operation of squirrel cage generators in various conditions. Up to now, there are a few practical realizations of squirrel cage generators, which are installed on board the vessels; mostly, these generators act as shaft generators, and it originates from the rules that require self-excitement of main electrical generators, acting as an immediate ready-to-use voltage source. In this article, we present a solution that utilizes an SCIG that operates with varying rotational speed as a shaft generator but can also act as an emergency propeller drive in case of main combustion engine failure. The main achievement of the presented work was the creation of a control table prepared for real-time software of the machine-side inverter. The data for the table were collected during the experimental research, and such a setup allowed us to use a DTC-controlled SCIG as a generator that rotated with variable speed and under changing load.
- Open Access
Main Ships Propulsion Boiler Control and Hardware-in-Loop Model Implementation
This article presents the issues related to the operation and modelling of a ship’s main propulsion steam boiler. Such objects are used widely in seagoing ships, especially very large crude oil carriers, as a main propulsion turbine feed. The advantages, along with the simple construction, thus greatly improve reliability making oil feed boilers an excellent source of power for the chosen types of large ships. It is worth mentioning that a vast part of the research work was performed in previous years regarding automatic control of boiler automation, but, since then, this technology has not been the focus of the researchers. Due to the fact that there is little information available on algorithms for controlling ship boilers, in the presented article, the authors created a unique solution for the control system of a propulsion boiler. The proposed control algorithm takes into account the operating parameters of the ship and allows for quick implementation in a simulation system working in a hardware loop, which can be used for quick testing of solutions for boiler systems fed with alternative fuels. In the future, fossil fuels will become less important than they are now, but the control techniques of boilers will eventually change due to different fuel parameters and, therefore, the development of such boilers is necessary. This article presents the results of research collected in real ship boilers during their operation and, based on the results, a digital model of such an object along with the necessary controls was created. This model was implemented into Hardware-In-Loop, which is the initial step for preparing the full model (including sensors, etc.) of a steam-heated boiler. The theoretical background, along with the chosen simulation and experimental results of control implemented into HIL, are presented to validate assumptions.
Open AccessMain Ships Propulsion Boiler Control and Hardware-in-Loop Model Implementation
This article presents the issues related to the operation and modelling of a ship’s main propulsion steam boiler. Such objects are used widely in seagoing ships, especially very large crude oil carriers, as a main propulsion turbine feed. The advantages, along with the simple construction, thus greatly improve reliability making oil feed boilers an excellent source of power for the chosen types of large ships. It is worth mentioning that a vast part of the research work was performed in previous years regarding automatic control of boiler automation, but, since then, this technology has not been the focus of the researchers. Due to the fact that there is little information available on algorithms for controlling ship boilers, in the presented article, the authors created a unique solution for the control system of a propulsion boiler. The proposed control algorithm takes into account the operating parameters of the ship and allows for quick implementation in a simulation system working in a hardware loop, which can be used for quick testing of solutions for boiler systems fed with alternative fuels. In the future, fossil fuels will become less important than they are now, but the control techniques of boilers will eventually change due to different fuel parameters and, therefore, the development of such boilers is necessary. This article presents the results of research collected in real ship boilers during their operation and, based on the results, a digital model of such an object along with the necessary controls was created. This model was implemented into Hardware-In-Loop, which is the initial step for preparing the full model (including sensors, etc.) of a steam-heated boiler. The theoretical background, along with the chosen simulation and experimental results of control implemented into HIL, are presented to validate assumptions.
- Open Access
- 7 August 2024
- Published by MDPI AG in Preprints.org
Main Ships Propulsion Boiler Control and Hardware-in-Loop Model Implementation
The article presents the issues related to the operation and modelling of the ship main propulsion steam boiler. Such objects are used widely in seagoing ships especially the very large crude oil carriers as a main propulsion turbine feed. The advantages of such along with simple construction thus great reliability make oil feed boilers an excellent source of power for chosen type of the large ships. It must be pointed out that a lot of research work was done in the previous years regarding automatic control of boiler automation but since then this technology was not in the focus of the researchers. In the future the fossil fuels will become less important than they are now, but the control techniques of boilers would eventually change due to different fuel parameters therefore, development of such is necessary. The article presents the results of research collected in real ship boilers during their operation and then, based on the results, a digital model of such an object was created. This model was implemented into Hardware-In-Loop which is the initial step for preparing the full model (including sensors etc.) of a steam heated boiler. Theoretical background along with chosen simulation and experimental results of control implemented into HIL were presented to validate assumptions...
- 7 August 2024
- Published by MDPI AG in Preprints.org
Open AccessMain Ships Propulsion Boiler Control and Hardware-in-Loop Model Implementation
The article presents the issues related to the operation and modelling of the ship main propulsion steam boiler. Such objects are used widely in seagoing ships especially the very large crude oil carriers as a main propulsion turbine feed. The advantages of such along with simple construction thus great reliability make oil feed boilers an excellent source of power for chosen type of the large ships. It must be pointed out that a lot of research work was done in the previous years regarding automatic control of boiler automation but since then this technology was not in the focus of the researchers. In the future the fossil fuels will become less important than they are now, but the control techniques of boilers would eventually change due to different fuel parameters therefore, development of such is necessary. The article presents the results of research collected in real ship boilers during their operation and then, based on the results, a digital model of such an object was created. This model was implemented into Hardware-In-Loop which is the initial step for preparing the full model (including sensors etc.) of a steam heated boiler. Theoretical background along with chosen simulation and experimental results of control implemented into HIL were presented to validate assumptions...
- Open Access
- 4 April 2024
- Published by MDPI AG in Electronics
- Vol. 13 (7) , 1365
Control Method of Load Sharing between AC Machine and Energy Storage Bank in the DC Grid
The article presents the issues related to load-power sharing in direct-current grid and a novel control method has advantages over known solutions. Unlike many similar-sounding papers, this article shows an attempt at creating fully controllable non-isolated system that allows for load-power sharing between a permanent magnet alternator equipped with machine-side converter (MSC) and a dual active bridge (DAB) tied to batteries or supercapacitor. The current-based load-power sharing is an essential feature of parallel-connected direct-current generators, and all types of voltage sources, in this way are contributing power to the system. To keep the optimal efficiency of the alternator, the rotational speed changes rely on proper mapping of the driving combustion engine. System components include a self-excited synchronous generator (SESG), operating at variable shaft speed, as well as batteries and supercapacitors that provide electricity for sudden electrical-load changes on the distribution grid. The core of the presented system is in a power-distribution method that consists of a programmed-controller structure allowing precise current distribution. A novelty of the proposed method is the use of a cascaded system of current and DC voltage regulators that allows for precise power-distribution control. In contrast with previously presented solutions, the proposed system allows for fast and accurate control of currents, loading parallel-connected DC voltage sources for wide-range generator speed changes. In the presented solution, both converters have been equipped with Schottky diodes, preventing the flow of equalizing currents between closed transistors in the parallel mode of operation. An experimental test-stand of the described system is presented with its theoretical basis and experimental results.
- 4 April 2024
- Published by MDPI AG in Electronics
- Vol. 13 (7) , 1365
Open AccessControl Method of Load Sharing between AC Machine and Energy Storage Bank in the DC Grid
The article presents the issues related to load-power sharing in direct-current grid and a novel control method has advantages over known solutions. Unlike many similar-sounding papers, this article shows an attempt at creating fully controllable non-isolated system that allows for load-power sharing between a permanent magnet alternator equipped with machine-side converter (MSC) and a dual active bridge (DAB) tied to batteries or supercapacitor. The current-based load-power sharing is an essential feature of parallel-connected direct-current generators, and all types of voltage sources, in this way are contributing power to the system. To keep the optimal efficiency of the alternator, the rotational speed changes rely on proper mapping of the driving combustion engine. System components include a self-excited synchronous generator (SESG), operating at variable shaft speed, as well as batteries and supercapacitors that provide electricity for sudden electrical-load changes on the distribution grid. The core of the presented system is in a power-distribution method that consists of a programmed-controller structure allowing precise current distribution. A novelty of the proposed method is the use of a cascaded system of current and DC voltage regulators that allows for precise power-distribution control. In contrast with previously presented solutions, the proposed system allows for fast and accurate control of currents, loading parallel-connected DC voltage sources for wide-range generator speed changes. In the presented solution, both converters have been equipped with Schottky diodes, preventing the flow of equalizing currents between closed transistors in the parallel mode of operation. An experimental test-stand of the described system is presented with its theoretical basis and experimental results.
- Open Access
- 1 February 2024
- Published by MDPI AG in Preprints.org
Control Method of Load Sharing between AC Machine and Energy Storage Bank in the DC Grid
The article presents the issues related to load sharing in direct current grid and a novel control method which has advantages over known solutions. Unlikely of many similar sounding papers this article shows attempt of creation fully controllable non-isolated system which allows load sharing between permanent magnet alternator equipped with machine side converter (MSC) and dual active bridge (DAB) tied to batteries or supercapacitor. The power sharing is essential feature of parallel connected direct current generators and all types of voltage sources in this way are contributing power to the system. Such system should have possibility of the rapid voltage build up in the case of sudden electrical load changes. To keep the optimal efficiency of the alternator the rotational speed changes according to proper mapping of driving combustion engine. When rotational speed is too low then sudden electrical load can cause significant voltage drop and time needed for voltage build up will vary according to RPM increase. In such situations the undervoltage system can trip the breaker and finally there may be a blackout. To avoid such problem the DC systems which consist of batteries and supercapacitor were introduced. System components include a self-excited synchronous generator (SESG) operating at variable shaft speed as well as batteries and supercapacitors that provide electricity for sudden electrical load changes on the distribution grid. The core of presented system is in power distribution method which consists of programmed controllers structure allowing precise currents distribution. A novelty in the proposed method is the use of a cascaded system of current and DC voltage regulators which allows power distribution precise control. In contrary to previously presented solutions, the proposed system allows fast and accurate control of currents loading parallel connected DC voltage sources for wide range generator speed changes. In presented solution both converters have been equipped with Schottky diodes preventing flow of equalizing currents between closed transistors in the parallel mode of operation. An experimental test-stand of the described system is presented with its theoretical basis and experimental results.
- 1 February 2024
- Published by MDPI AG in Preprints.org
Open AccessControl Method of Load Sharing between AC Machine and Energy Storage Bank in the DC Grid
The article presents the issues related to load sharing in direct current grid and a novel control method which has advantages over known solutions. Unlikely of many similar sounding papers this article shows attempt of creation fully controllable non-isolated system which allows load sharing between permanent magnet alternator equipped with machine side converter (MSC) and dual active bridge (DAB) tied to batteries or supercapacitor. The power sharing is essential feature of parallel connected direct current generators and all types of voltage sources in this way are contributing power to the system. Such system should have possibility of the rapid voltage build up in the case of sudden electrical load changes. To keep the optimal efficiency of the alternator the rotational speed changes according to proper mapping of driving combustion engine. When rotational speed is too low then sudden electrical load can cause significant voltage drop and time needed for voltage build up will vary according to RPM increase. In such situations the undervoltage system can trip the breaker and finally there may be a blackout. To avoid such problem the DC systems which consist of batteries and supercapacitor were introduced. System components include a self-excited synchronous generator (SESG) operating at variable shaft speed as well as batteries and supercapacitors that provide electricity for sudden electrical load changes on the distribution grid. The core of presented system is in power distribution method which consists of programmed controllers structure allowing precise currents distribution. A novelty in the proposed method is the use of a cascaded system of current and DC voltage regulators which allows power distribution precise control. In contrary to previously presented solutions, the proposed system allows fast and accurate control of currents loading parallel connected DC voltage sources for wide range generator speed changes. In presented solution both converters have been equipped with Schottky diodes preventing flow of equalizing currents between closed transistors in the parallel mode of operation. An experimental test-stand of the described system is presented with its theoretical basis and experimental results.
- Open Access
A Novel Method for Diagnosing Power Electronics Devices Using Elastic Wave Emission
This work is an introduction of acoustic emission (AE) signals used in order to detect the malfunction of selected semiconductor elements. The authors proposed the use of internally generated signals (elastic waves) of acoustic emission leading to the detection of the pre-fail state of switching IGBT transistors. The analysis of the AE signals allows the creation of a reference pattern of properly working transistors and at the same time the identification of abnormal signals, which are generated by a defective element. Unlike many papers, this article shows experimental results demonstrating a comparison of undamaged, properly working and defective IGBT transistors which can be used, for example, as a reference for diagnostic tools. Analysis of the signal in the frequency domain obtained from the faulty transistor (overheated or with damaged casing) shows the presence of additional frequencies which can indicate the imminent occurrence of critical damage.
Open AccessA Novel Method for Diagnosing Power Electronics Devices Using Elastic Wave Emission
This work is an introduction of acoustic emission (AE) signals used in order to detect the malfunction of selected semiconductor elements. The authors proposed the use of internally generated signals (elastic waves) of acoustic emission leading to the detection of the pre-fail state of switching IGBT transistors. The analysis of the AE signals allows the creation of a reference pattern of properly working transistors and at the same time the identification of abnormal signals, which are generated by a defective element. Unlike many papers, this article shows experimental results demonstrating a comparison of undamaged, properly working and defective IGBT transistors which can be used, for example, as a reference for diagnostic tools. Analysis of the signal in the frequency domain obtained from the faulty transistor (overheated or with damaged casing) shows the presence of additional frequencies which can indicate the imminent occurrence of critical damage.
- Open Access
Effective Parameters of a Compression-Ignition Engine Powered by a Mixture Consisting of Ethyl-Tetra-Butyl Ether and Diesel Fuel
The present article presents the results of analytical research on the possibility of using a mixture consisting of diesel oil and ethyl-tertiary-butyl ether in different percentages of EETB to power compression-ignition engines. The calculations were carried out for a four-stroke diesel engine intended for use as a power generator, among other things. In order to illustrate and verify the correctness of the calculations, a mathematical model was built that confirmed the correctness of the calculations. The calculations focused on a thorough analysis of the elemental composition (content of individual elements) of the fuel and, in particular, the carbon content in the fuel. A calculation algorithm was applied for mixing diesel fuel with ethyl-tertiary butyl ether in a share of EETB 5% + 95% ON, 10% EETB + 90% ON, 20% EETB ++80% ON, 30% EETB + 70% ON, 40% EETB + 60% ON. In this study, it determined the parameters of the working medium, the parameters of the environment and residual gases, and the processes (charge filling, compression, combustion, expansion) and effective parameters of the engine. The calculations used in this study led to heat balance, and a summary of the obtained results and their comparison with diesel oil are also described in this study. The results show the feasibility of using a mixture of ethyl-tertiary-butyl ether as a fuel in diesel engines. The results are very similar to those for 100% diesel. The results of our calculations confirming the possibility of using ether for fuel and thus maintaining similar engine operating parameters.
Open AccessEffective Parameters of a Compression-Ignition Engine Powered by a Mixture Consisting of Ethyl-Tetra-Butyl Ether and Diesel Fuel
The present article presents the results of analytical research on the possibility of using a mixture consisting of diesel oil and ethyl-tertiary-butyl ether in different percentages of EETB to power compression-ignition engines. The calculations were carried out for a four-stroke diesel engine intended for use as a power generator, among other things. In order to illustrate and verify the correctness of the calculations, a mathematical model was built that confirmed the correctness of the calculations. The calculations focused on a thorough analysis of the elemental composition (content of individual elements) of the fuel and, in particular, the carbon content in the fuel. A calculation algorithm was applied for mixing diesel fuel with ethyl-tertiary butyl ether in a share of EETB 5% + 95% ON, 10% EETB + 90% ON, 20% EETB ++80% ON, 30% EETB + 70% ON, 40% EETB + 60% ON. In this study, it determined the parameters of the working medium, the parameters of the environment and residual gases, and the processes (charge filling, compression, combustion, expansion) and effective parameters of the engine. The calculations used in this study led to heat balance, and a summary of the obtained results and their comparison with diesel oil are also described in this study. The results show the feasibility of using a mixture of ethyl-tertiary-butyl ether as a fuel in diesel engines. The results are very similar to those for 100% diesel. The results of our calculations confirming the possibility of using ether for fuel and thus maintaining similar engine operating parameters.
- Open Access
Measurement Methods in the Operation of Ships and Offshore Facilities
The development of modern measurement methods for ship systems has occurred due to economic changes and increasingly stringent environmental requirements
Open AccessMeasurement Methods in the Operation of Ships and Offshore Facilities
The development of modern measurement methods for ship systems has occurred due to economic changes and increasingly stringent environmental requirements