GIGianluca Iori

Gianluca Iori

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gianluca Iori has a total of 167 co-authors. Here are the top co-authors by number of shared publications:

  • Kay Raum

    Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Center for Biomedicine, Berlin, Germany

    9 shared publications
  • Frans Heyer

    Department of Internal Medicine, NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University Medical Center, Maastricht, the Netherlands; Department of Internal Medicine, VieCuri Medical Center, Venlo, the Netherlands

    4 shared publications
  • Melanie Gräsel

    Sektion Biomedizinische Bildgebung, Klinik für Radiologie und Neuroradiologie, Christian-Albrechts-Universität zu Kiel, Kiel, Germany

    4 shared publications
  • Andreas Reisinger

    Division Biomechanics, Karl Landsteiner University of Health Sciences, Krems, Austria

    3 shared publications
  • Caroline Wyers

    Department of Internal Medicine, NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University Medical Center, Maastricht, the Netherlands; Department of Internal Medicine, VieCuri Medical Center, Venlo, the Netherlands

    3 shared publications
  • Dieter Pahr

    Division Biomechanics, Karl Landsteiner University of Health Sciences, Krems, Austria; Institute for Lightweight Design and Structural Biomechanics, TU Wien, Vienna, Austria

    3 shared publications

Latest Publications

  • Open Access

    High-density void-free gold sub-micrometer gratings for X-ray grating interferometry

    by Liyang Chen, Qihui Yu, Ji Hye Kang, Alexandre Pereira, Gianluca Iori, Mattia Guscetti, Daniel Josell, Konstantins Jefimovs, Marco Stampanoni, Lucia Romano

    This work details the combination of displacement Talbot lithography, deep reactive dry etching of silicon, and bottom-up gold electrochemical deposition to produce void-free gold microgratings with 700 nm wide Au lines of 27 μm depth, corresponding to an aspect ratio (depth/width) of 38 with vertical sidewall. Systematic optimization of the grating design and manufacturing processes yielded high-quality sub-micrometer gold gratings with precisely controlled structural profiles, minimal deviation of the duty cycle as a function of depth and absence of voids in the Au filling. A symmetric X-ray grating interferometer at 20 keV design energy with 1.2 μm pitch gratings showcases the application.

  • Open Access

    Open and reproducible research in musculoskeletal imaging: Why it matters and how to implement it with the guidelines of the ORMIR community

    by Serena Bonaretti, Mojtaba Barzegari, Melissa Bevers, Steven Boyd, Andrew J Burghardt, Donnie Cameron, Francesco Chiumento, Gianluigi Crimi, Gerard Degenhart, Pholpat Durongbhan, et al.

    The Open and Reproducible Musculoskeletal Imaging Research (ORMIR) community is a scientific community dedicated to promoting openness and reproducibility in musculoskeletal imaging, image processing, and computational modelling. In this perspective paper, we outline the motivations for conducting transparent research and provide practical guidelines to implement it. We start with defining open and reproducible research and describing the benefits and challenges of working transparently. Next, we redefine the outputs of a computational research study as—ideally—a combination of data, code, and a publication, recommend a folder and file structure that reflects these three study outcomes, and describe how to maintain and update such a structure during the study and at study publication. Finally, we emphasize that working in an open and reproducible manner is a learning process and the best way to acquire the necessary competencies is simply to start. Lay summary: The ORMIR community promotes openness and reproducibility in musculoskeletal imaging research. In this perspective paper, we explain why transparency matters and recommend how to conduct a computational study in an open and reproducible manner focusing on its three outputs: data, code, and publication. Finally, we highlight that the best way to learn these practices is simply to start.


  • Open Access

    High-resolution tomographic analysis of microstructure and porosity in mock-ups of ancient-inspired mosaics

    by Neva M.E. Stucchi, Gianluca Iori, Philipp Hans, Andrea Vavasori, Giulia Franceschin, Arianna Traviglia

  • Open Access

    Predicting physiological hip joint loads with inverse bone remodeling using clinically available QCT images

    by Sebastian Bachmann, Gianluca Iori, Kay Raum, Dieter H. Pahr, Alexander Synek


  • Open Access

    Synchrotron computed tomography of 5000 years old faience beads from Southeastern Anatolia (Türkiye)

    by Gonca Dardeniz, Gülistan Büyükgedik, Onur Kaya, Suat Özkorucuklu, Fareeha Hameed, Gianluca Iori

  • Open Access

    Non-destructive examination of ancient vitreous materials from Southwest Asia: Synchrotron computed tomography at the BEATS beamline of SESAME

    by Gianluca Iori, Philipp Hans, Neva Maria Elisabetta Stucchi, Latif Ullah Khan, Abdellatif Saadaldin, Elena Possenti, Giulia Franceschin, Samah Al Khasoneh, Gian Luca Bonora, Gonca Dardeniz


  • Open Access

    BEATS: BEAmline for synchrotron X-ray microTomography at SESAME

    by Gianluca Iori, Mustafa Alzu'Bi, Anas Abbadi, Yazeed Al Momani, Abdel Rahman Hasoneh, Pierre Van Vaerenbergh, Ivan Cudin, Jordi Marcos, Abdalla Ahmad, Anas Mohammad, et al.

    The ID10 beamline of the SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) synchrotron light source in Jordan was inaugurated in June 2023 and is now open to scientific users. The beamline, which was designed and installed within the European Horizon 2020 project BEAmline for Tomography at SESAME (BEATS), provides full-field X-ray radiography and microtomography imaging with monochromatic or polychromatic X-rays up to photon energies of 100 keV. The photon source generated by a 2.9 T wavelength shifter with variable gap, and a double-multilayer monochromator system allow versatile application for experiments requiring either an X-ray beam with high intensity and flux, and/or a partially spatial coherent beam for phase-contrast applications. Sample manipulation and X-ray detection systems are designed to allow scanning samples with different size, weight and material, providing image voxel sizes from 13 µm down to 0.33 µm. A state-of-the-art computing infrastructure for data collection, three-dimensional (3D) image reconstruction and data analysis allows the visualization and exploration of results online within a few seconds from the completion of a scan. Insights from 3D X-ray imaging are key to the investigation of specimens from archaeology and cultural heritage, biology and health sciences, materials science and engineering, earth, environmental sciences and more. Microtomography scans and preliminary results obtained at the beamline demonstrate that the new beamline ID10-BEATS expands significantly the range of scientific applications that can be targeted at SESAME.


  • Open Access

    Alrecon: computed tomography reconstruction web application based on Solara

    by Gianluca Iori, Philipp Hans, Ibrahim Foudeh, Mustafa Alzu’BI, Malik Al Mohammad, Salman Matalgah

    Synchrotron X-ray computed tomography is a non-destructive 3D imaging technique that offers the possibility to study the internal microstructure of samples with high spatial and temporal resolution. Given its unmatched image quality and acquisition speed, and the possibility to preserve the specimens, there is an increasing demand for this technique, from scientific users from innumerable disciplines. Computed tomography reconstruction is the computational process by which experimental radiographs are converted to a meaningful 3-dimensional image after the scan. The procedure involves pre-processing steps for image background and artifact correction on raw data, a reconstruction step approximating the inverse Radon-transform, and writing of the reconstructed volume image to disk. Several open-source Python packages exist to help scientists in the process of tomography reconstruction, by offering efficient implementations of reconstruction algorithms exploiting central or graphics processing unit (CPU and GPU, respectively), and by automating significant portions of the data processing pipeline. A further increase in productivity is attained by scheduling and parallelizing demanding reconstructions on high performance computing (HPC) clusters. Nevertheless, visual inspection and interactive selection of optimal reconstruction parameters remain crucial steps that are often performed in close interaction with the end-user of the data. As a result, the reconstruction task involves more than one software. Graphical user interfaces are provided to the user for fast inspection and optimization of reconstructions, while HPC resources are often accessed through scripts and command line interface. We propose Alrecon, a pure Python web application for tomographic reconstruction built using Solara. Alrecon offers users an intuitive and reactive environment for exploring data and customizing reconstruction pipelines. By leveraging upon popular 3D image visualization tools, and by providing a user-friendly interface for reconstruction scheduling on HPC resources, Alrecon guarantees productivity and efficient use of resources for any type of beamline user.


  • Open Access

    Alrecon: computed tomography reconstruction web application based on Solara

    by Gianluca Iori, Ibrahim Foudeh, Mustafa Alzu’BI, Malik Al Mohammad, Salman Matalgah

    Synchrotron X-ray computed tomography is a non-destructive 3D imaging technique that offers the possibility to study the internal microstructure of samples with high spatial and temporal resolution. Given its unmatched image quality and acquisition speed, and the possibility to preserve the specimens, there is an increasing demand for this technique, from scientific users from innumerable disciplines. Computed tomography reconstruction is the computational process by which experimental radiographs are converted to a meaningful 3-dimensional image after the scan. The procedure involves pre-processing steps for image background and artifact correction on raw data, a reconstruction step approximating the inverse Radon-transform, and writing of the reconstructed volume image to disk. Several open-source Python packages exist to help scientists in the process of tomography reconstruction, by offering efficient implementations of reconstruction algorithms exploiting central or graphics processing unit (CPU and GPU, respectively), and by automating significant portions of the data processing pipeline. A further increase in productivity is attained by scheduling and parallelizing demanding reconstructions on high performance computing (HPC) clusters. Nevertheless, visual inspection and interactive selection of optimal reconstruction parameters remain crucial steps that are often performed in close interaction with the end-user of the data. As a result, the reconstruction task involves more than one software. Graphical user interfaces are provided to the user for fast inspection and optimization of reconstructions, while HPC resources are often accessed through scripts and command line interface. We propose Alrecon, a pure Python web application for tomographic reconstruction built using Solara. Alrecon offers users an intuitive and reactive environment for exploring data and customizing reconstruction pipelines. By leveraging upon popular 3D image visualization tools, and by providing a user-friendly interface for reconstruction scheduling on HPC resources, Alrecon guarantees productivity and efficient use of resources for any type of beamline user.