Johanna Gleichauf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Johanna Gleichauf has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Koelpin
Hamburg University of Technology
2 shared publications - Christine Niebler
Technische Hochschule Nürnberg
2 shared publications - Lukas Hennemann
Nuremberg Institute of Technology, 90489 Nuremberg, Germany
2 shared publications - Sven Herrmann
Nuremberg Institute of Technology, Department of Electrical Engineering, Precision Engineering and Information Technology, Nuremberg, Germany
2 shared publications Alexander Koelpin
Hamburg University of Technology, Institute of High-Frequency Technology, Hamburg, Germany
1 shared publicationChristian Pfitzner
Technische Hochschule Nuremberg
1 shared publication
Latest Publications
- Open Access
- 1 September 2024
- Published by Association for Computing Machinery (ACM)
- p. 651-654
Non-Contact In-Car Monitoring of Heart Rate: Evaluating the Eulerian Video Magnification Algorithm in a Driving Simulator Study
Monitoring drivers’ health is crucial for saving lives in emergencies and enabling in-car health applications. The state of the art in pulse monitoring is contact-based sensors which impair the driving experience and have to be applied manually before driving. This paper focuses on automated hyper parameter optimizing the Eulerian Video Magnification (EVM) algorithm, which detects heart rates through non-contact facial camera images, for use in driving scenarios. We conducted a user study where 21 participants performed a driving simulation while their heart rates were recorded by a wearable fitness tracker (serving as ground truth) and facial images with an RGB camera. Our findings indicate that, despite using the optuna library for hyper parameter tuning, the Eulerian Video Magnification algorithm is insufficient for accurate pulse detection in a driving simulator environment.
- 1 September 2024
- Published by Association for Computing Machinery (ACM)
- p. 651-654
Open AccessNon-Contact In-Car Monitoring of Heart Rate: Evaluating the Eulerian Video Magnification Algorithm in a Driving Simulator Study
Monitoring drivers’ health is crucial for saving lives in emergencies and enabling in-car health applications. The state of the art in pulse monitoring is contact-based sensors which impair the driving experience and have to be applied manually before driving. This paper focuses on automated hyper parameter optimizing the Eulerian Video Magnification (EVM) algorithm, which detects heart rates through non-contact facial camera images, for use in driving scenarios. We conducted a user study where 21 participants performed a driving simulation while their heart rates were recorded by a wearable fitness tracker (serving as ground truth) and facial images with an RGB camera. Our findings indicate that, despite using the optuna library for hyper parameter tuning, the Eulerian Video Magnification algorithm is insufficient for accurate pulse detection in a driving simulator environment.
- Open Access
- 23 January 2024
- Published by Springer Nature in Scientific Data
- Vol. 11 (1) , 1-8
A Time-of-Flight and Radar Dataset of a neonatal Thorax Simulator with synchronized Reference Sensor Signals for respiratory Rate Detection
In this paper we present an open-source Time-of-Flight and radar dataset of a neonatal thorax simulator for the development of respiratory rate detection algorithms. As it is very difficult to gain recordings of (preterm) neonates and there is hardly any open-source data available, we built our own neonatal thorax simulator which simulates the movement of the thorax due to respiration. We recorded Time-of-Flight (ToF) and radar data at different respiratory rates in a range of 5 to 80 breaths per minute (BPM) and with varying upstroke heights. As gold standard a laser micrometer was used. The open-source data can be used to test new algorithms for non-contact respiratory rate detection.
- 23 January 2024
- Published by Springer Nature in Scientific Data
- Vol. 11 (1) , 1-8
Open AccessA Time-of-Flight and Radar Dataset of a neonatal Thorax Simulator with synchronized Reference Sensor Signals for respiratory Rate Detection
In this paper we present an open-source Time-of-Flight and radar dataset of a neonatal thorax simulator for the development of respiratory rate detection algorithms. As it is very difficult to gain recordings of (preterm) neonates and there is hardly any open-source data available, we built our own neonatal thorax simulator which simulates the movement of the thorax due to respiration. We recorded Time-of-Flight (ToF) and radar data at different respiratory rates in a range of 5 to 80 breaths per minute (BPM) and with varying upstroke heights. As gold standard a laser micrometer was used. The open-source data can be used to test new algorithms for non-contact respiratory rate detection.
- Open Access
Sensor Fusion for the Robust Detection of Facial Regions of Neonates Using Neural Networks
The monitoring of vital signs and increasing patient comfort are cornerstones of modern neonatal intensive care. Commonly used monitoring methods are based on skin contact which can cause irritations and discomfort in preterm neonates. Therefore, non-contact approaches are the subject of current research aiming to resolve this dichotomy. Robust neonatal face detection is essential for the reliable detection of heart rate, respiratory rate and body temperature. While solutions for adult face detection are established, the unique neonatal proportions require a tailored approach. Additionally, sufficient open-source data of neonates on the NICU is lacking. We set out to train neural networks with the thermal-RGB-fusion data of neonates. We propose a novel indirect fusion approach including the sensor fusion of a thermal and RGB camera based on a 3D time-of-flight (ToF) camera. Unlike other approaches, this method is tailored for close distances encountered in neonatal incubators. Two neural networks were used with the fusion data and compared to RGB and thermal networks. For the class “head” we reached average precision values of 0.9958 (RetinaNet) and 0.9455 (YOLOv3) for the fusion data. Compared with the literature, similar precision was achieved, but we are the first to train a neural network with fusion data of neonates. The advantage of this approach is in calculating the detection area directly from the fusion image for the RGB and thermal modality. This increases data efficiency by 66%. Our results will facilitate the future development of non-contact monitoring to further improve the standard of care for preterm neonates.
Open AccessSensor Fusion for the Robust Detection of Facial Regions of Neonates Using Neural Networks
The monitoring of vital signs and increasing patient comfort are cornerstones of modern neonatal intensive care. Commonly used monitoring methods are based on skin contact which can cause irritations and discomfort in preterm neonates. Therefore, non-contact approaches are the subject of current research aiming to resolve this dichotomy. Robust neonatal face detection is essential for the reliable detection of heart rate, respiratory rate and body temperature. While solutions for adult face detection are established, the unique neonatal proportions require a tailored approach. Additionally, sufficient open-source data of neonates on the NICU is lacking. We set out to train neural networks with the thermal-RGB-fusion data of neonates. We propose a novel indirect fusion approach including the sensor fusion of a thermal and RGB camera based on a 3D time-of-flight (ToF) camera. Unlike other approaches, this method is tailored for close distances encountered in neonatal incubators. Two neural networks were used with the fusion data and compared to RGB and thermal networks. For the class “head” we reached average precision values of 0.9958 (RetinaNet) and 0.9455 (YOLOv3) for the fusion data. Compared with the literature, similar precision was achieved, but we are the first to train a neural network with fusion data of neonates. The advantage of this approach is in calculating the detection area directly from the fusion image for the RGB and thermal modality. This increases data efficiency by 66%. Our results will facilitate the future development of non-contact monitoring to further improve the standard of care for preterm neonates.
- Open Access
Automated Non-Contact Respiratory Rate Monitoring of Neonates Based on Synchronous Evaluation of a 3D Time-of-Flight Camera and a Microwave Interferometric Radar Sensor
This paper introduces an automatic non-contact monitoring method based on the synchronous evaluation of a 3D time-of-flight (ToF) camera and a microwave interferometric radar sensor for measuring the respiratory rate of neonates. The current monitoring on the Neonatal Intensive Care Unit (NICU) has several issues which can cause pressure marks, skin irritations and eczema. To minimize these risks, a non-contact system made up of a 3D time-of-flight camera and a microwave interferometric radar sensor is presented. The 3D time-of-flight camera delivers 3D point clouds which can be used to calculate the change in distance of the moving chest and from it the respiratory rate. The disadvantage of the ToF camera is that the heartbeat cannot be determined. The microwave interferometric radar sensor determines the change in displacement caused by the respiration and is even capable of measuring the small superimposed movements due to the heartbeat. The radar sensor is very sensitive towards movement artifacts due to, e.g., the baby moving its arms. To allow a robust vital parameter detection the data of both sensors was evaluated synchronously. In this publication, we focus on the first step: determining the respiratory rate. After all processing steps, the respiratory rate determined by the radar sensor was compared to the value received from the 3D time-of-flight camera. The method was validated against our gold standard: a self-developed neonatal simulation system which can simulate different breathing patterns. In this paper, we show that we are the first to determine the respiratory rate by evaluating the data of an interferometric microwave radar sensor and a ToF camera synchronously. Our system delivers very precise breaths per minute (BPM) values within the norm range of 20–60 BPM with a maximum difference of 3 BPM (for the ToF camera itself at 30 BPM in normal mode). Especially in lower respiratory rate regions, i.e., 5 and 10 BPM, the synchronous evaluation is required to compensate the drawbacks of the ToF camera. In the norm range, the ToF camera performs slightly better than the radar sensor.
Open AccessAutomated Non-Contact Respiratory Rate Monitoring of Neonates Based on Synchronous Evaluation of a 3D Time-of-Flight Camera and a Microwave Interferometric Radar Sensor
This paper introduces an automatic non-contact monitoring method based on the synchronous evaluation of a 3D time-of-flight (ToF) camera and a microwave interferometric radar sensor for measuring the respiratory rate of neonates. The current monitoring on the Neonatal Intensive Care Unit (NICU) has several issues which can cause pressure marks, skin irritations and eczema. To minimize these risks, a non-contact system made up of a 3D time-of-flight camera and a microwave interferometric radar sensor is presented. The 3D time-of-flight camera delivers 3D point clouds which can be used to calculate the change in distance of the moving chest and from it the respiratory rate. The disadvantage of the ToF camera is that the heartbeat cannot be determined. The microwave interferometric radar sensor determines the change in displacement caused by the respiration and is even capable of measuring the small superimposed movements due to the heartbeat. The radar sensor is very sensitive towards movement artifacts due to, e.g., the baby moving its arms. To allow a robust vital parameter detection the data of both sensors was evaluated synchronously. In this publication, we focus on the first step: determining the respiratory rate. After all processing steps, the respiratory rate determined by the radar sensor was compared to the value received from the 3D time-of-flight camera. The method was validated against our gold standard: a self-developed neonatal simulation system which can simulate different breathing patterns. In this paper, we show that we are the first to determine the respiratory rate by evaluating the data of an interferometric microwave radar sensor and a ToF camera synchronously. Our system delivers very precise breaths per minute (BPM) values within the norm range of 20–60 BPM with a maximum difference of 3 BPM (for the ToF camera itself at 30 BPM in normal mode). Especially in lower respiratory rate regions, i.e., 5 and 10 BPM, the synchronous evaluation is required to compensate the drawbacks of the ToF camera. In the norm range, the ToF camera performs slightly better than the radar sensor.
- 18 April 2019
- Published by Springer Nature
- p. 603-624
Sensor Fusion Approach for an Autonomous Shunting Locomotive
- 18 April 2019
- Published by Springer Nature
- p. 603-624
Sensor Fusion Approach for an Autonomous Shunting Locomotive