Matthieu Ollivier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthieu Ollivier has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Christophe Jacquet
Institute of Movement and Locomotion, Department of Orthopedics and Traumatology, St Marguerite Hospital, Marseille, France
11 shared publicationsSebastien Parratte
International Knee & Joint Centre, Abu Dhabi, United Arab Emirates
8 shared publicationsAkash Sharma
Institute of Movement and Locomotion Department of Orthopedics and Traumatology St. Marguerite Hospital Marseille France
5 shared publicationsKristian Kley
London Osteotomy Centre Harley Street Specialist Hospital London United Kingdom
5 shared publicationsMatthieu Ehlinger
Service de Chirurgie Orthopédique et de Traumatologie du Membre Inférieur, Pôle Locomax, Hôpital de Hautepierre II, Hôpitaux Universitaires de Strasbourg, 1, avenue Molière, 67098 Strasbourg cedex, France
5 shared publicationsJean-Noël Argenson
CNRS, ISM UMR 7287, Aix-Marseille université, 13288 Marseille cedex 09, France; Department of orthopaedics and traumatology, institute of movement and locomotion, St. Marguerite hospital, 13009 Marseille, France
4 shared publications
Latest Publications
- 31 October 2025
- Published by Springer Nature in International Orthopaedics
- Vol. 49 (12) , 2837-2843
Results of trabecular metal acetabular reconstruction in two-stage revision of infected total hip arthroplasty with large bone defect
Introduction Two-stage revision of total hip arthroplasty (THA) remains the gold standard for periprosthetic joint infection (PJI). Trabecular Metal (TM) offers a valuable option for acetabular reconstruction, but evidence in septic revision THA (rTHA) is scarce. This study evaluated outcomes of TM implants in two-stage rTHA for infection, hypothesizing results comparable to existing literature, especially in cases with major bone loss. Materials and method We retrospectively analyzed 32 two-stage rTHA (32 patients) performed between January 2010 and July 2021, with a minimum two years follow-up. All patients received TM acetabular implants. Bone loss was classified according to Paprosky: 3 IIA, 8 IIB, 3 IIC, 12 IIIA, and 6 IIIB, with pelvic discontinuity in 13 cases. Results At mean follow-up of 30.2 ± 10.9 months (range, 24 to 69), infection eradication was achieved in 87,5%. Staphylococcus species accounted for 84,4% of cases. Seven complications occurred, including six reoperations: five revisions (two for recurrent infection, 3 for mechanical failure). The overall failure rate was 21,9%. At 24 months, the healing rate, including all causes of failure, was 78,1% and revision-free rate 84,4%. Conclusion TM implants in two-stage rTHA for septic failure achieved satisfactory mid-term results, even in advanced acetabular bone loss (44% Paprosky II, 56% Paprosky III). To our knowledge, this is the first study exclusively evaluating TM in this context, supporting its role in complex acetabular reconstruction during septic revisions. Level of evidence IV
- 31 October 2025
- Published by Springer Nature in International Orthopaedics
- Vol. 49 (12) , 2837-2843
Results of trabecular metal acetabular reconstruction in two-stage revision of infected total hip arthroplasty with large bone defect
Introduction Two-stage revision of total hip arthroplasty (THA) remains the gold standard for periprosthetic joint infection (PJI). Trabecular Metal (TM) offers a valuable option for acetabular reconstruction, but evidence in septic revision THA (rTHA) is scarce. This study evaluated outcomes of TM implants in two-stage rTHA for infection, hypothesizing results comparable to existing literature, especially in cases with major bone loss. Materials and method We retrospectively analyzed 32 two-stage rTHA (32 patients) performed between January 2010 and July 2021, with a minimum two years follow-up. All patients received TM acetabular implants. Bone loss was classified according to Paprosky: 3 IIA, 8 IIB, 3 IIC, 12 IIIA, and 6 IIIB, with pelvic discontinuity in 13 cases. Results At mean follow-up of 30.2 ± 10.9 months (range, 24 to 69), infection eradication was achieved in 87,5%. Staphylococcus species accounted for 84,4% of cases. Seven complications occurred, including six reoperations: five revisions (two for recurrent infection, 3 for mechanical failure). The overall failure rate was 21,9%. At 24 months, the healing rate, including all causes of failure, was 78,1% and revision-free rate 84,4%. Conclusion TM implants in two-stage rTHA for septic failure achieved satisfactory mid-term results, even in advanced acetabular bone loss (44% Paprosky II, 56% Paprosky III). To our knowledge, this is the first study exclusively evaluating TM in this context, supporting its role in complex acetabular reconstruction during septic revisions. Level of evidence IV
- 5 August 2024
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 25 (3) , 747-754
Freezing does not influence the microarchitectural parameters of the microstructure of the freshly harvested femoral head bone
The femoral head is one of the most commonly used bones for allografts and biomechanical studies. However, there are few reports on the trabecular bone microarchitectural parameters of freshly harvested trabecular bones. To our knowledge, this is the first study to characterize the microstructure of femoral heads tested immediately after surgery and compare it with the microstructure obtained with conventional freezing. This study aims to investigate whether freezing at −80 °C for 6 weeks affects the trabecular microstructure of freshly harvested bone tissue. This study was divided into two groups: one with freshly harvested human femoral heads and the other with the same human femoral heads frozen at −80 °C for 6 weeks. Each femoral head was scanned using an X-ray microcomputed tomography scanner (µCT) to obtain the microarchitectural parameters, including the bone volume fraction (BV/TV), the mean trabecular thickness (Tb.th), the trabecular separation (Tb.sp), the degree of anisotropy (DA), and the connectivity density (Conn.D). There was no statistically significant difference between the fresh and the frozen groups for any of the parameters measured. This study shows that freezing at −80 °C for 6 weeks does not alter bone microstructure compared with freshly harvested femoral heads tested immediately after surgery.
- 5 August 2024
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 25 (3) , 747-754
Freezing does not influence the microarchitectural parameters of the microstructure of the freshly harvested femoral head bone
The femoral head is one of the most commonly used bones for allografts and biomechanical studies. However, there are few reports on the trabecular bone microarchitectural parameters of freshly harvested trabecular bones. To our knowledge, this is the first study to characterize the microstructure of femoral heads tested immediately after surgery and compare it with the microstructure obtained with conventional freezing. This study aims to investigate whether freezing at −80 °C for 6 weeks affects the trabecular microstructure of freshly harvested bone tissue. This study was divided into two groups: one with freshly harvested human femoral heads and the other with the same human femoral heads frozen at −80 °C for 6 weeks. Each femoral head was scanned using an X-ray microcomputed tomography scanner (µCT) to obtain the microarchitectural parameters, including the bone volume fraction (BV/TV), the mean trabecular thickness (Tb.th), the trabecular separation (Tb.sp), the degree of anisotropy (DA), and the connectivity density (Conn.D). There was no statistically significant difference between the fresh and the frozen groups for any of the parameters measured. This study shows that freezing at −80 °C for 6 weeks does not alter bone microstructure compared with freshly harvested femoral heads tested immediately after surgery.
- 3 January 2023
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 481 (6) , 1129-1139
Does Matching Femoral Size and Shape Improve Bone Fit and Patient-reported Outcomes in TKA? A Matched Controlled Study
Background: Some researchers have suggested that achieving good component coverage over the host bone during TKA (while avoiding implant overhang) may help achieve durable implant fixation and may be associated with better outcomes scores. However, the evidence about this is limited and contradictory. Contemporary morphometric TKA includes a wide array of components with various shapes and sizes, based on large anatomic databases and specific software that simulates bone cuts. Morphometric tibial components have shown improved bone coverage and better clinical outcomes than standardized implants, but the role of morphometric femoral components in bone coverage has not been studied precisely. Questions/purposes: In a retrospective, controlled study that used patient matching, we asked: (1) Does the use of a contemporary morphometric component with more available sizes provide better femoral component fit and bone coverage than an earlier design with fewer sizes? (2) Are component fit and the presence of component overhang or underhang associated with different Knee Society Score (KSS) or Knee Injury and Osteoarthritis Outcome Score (KOOS) for Joint Replacement? Methods: From 2012 to 2013, we performed 403 TKAs according to the following criteria: TKA performed for primary tricompartmental arthritis of the knee; varus, valgus, and flexion deformity less than 15°; and age between 18 and 85 years on the day of surgery. Among these 403 TKAs, 237 were performed using a morphometric implant and 166 with the earlier nonmorphometric implant. At 2 years of follow-up, 3% of patients in the morphometric group and 5% in the nonmorphometric group were lost to follow-up. Based on age, BMI, gender, and preoperative KSS and KOOS, two groups of 30 patients were matched in a 1:1 ratio from this longitudinally maintained database. Clinical outcomes were measured preoperatively and at a minimum follow-up of 2 years in both groups, using the KSS and KOOS. We evaluated postoperative CT images for each patient to analyze femoral implant rotation, bone coverage, and overhang and underhang status. Results: The overhang status was similar between the two groups (23% had an overhang component in the morphometric knee group and 27% had an overhang component in the nonmorphometric knee group), and overhang was most frequently found in the lateral distal zone and medial anterior chamfer. Better cortical bone coverage was found in the morphometric knee group, with a thinner bone margin between the component edge and cortical border (morphometric group: 3 mm versus nonmorphometric knee group: 5 mm; p = 0.01). In general, there were few between-group differences in terms of patient-reported outcomes; of the seven metrics we analyzed, only the KSS favored the morphometric knee implant by a margin larger than the minimum clinically important difference (KSS mean difference: 21 points for the morphometric knee group; p < 0.05). Overhang of the femoral component of > 2 mm was associated with poorer KOOS, but not KSS, whereas a thinner bone margin had a beneficial impact on pain and global clinical scores (KOOS and KSS: p < 0.05). Conclusion: The use of a morphometric femoral component design showed slightly improved bone fit and pain score according to the KSS at midterm follow-up compared with earlier implants with fewer sizes. Overhang > 2 mm was associated with worse KOOS. The tendency toward better outcomes in morphometric implants warrants longer-term evaluation before any definite conclusions about the association between bone fit and clinical results can be drawn. Level of Evidence Level III, therapeutic study.
- 3 January 2023
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 481 (6) , 1129-1139
Does Matching Femoral Size and Shape Improve Bone Fit and Patient-reported Outcomes in TKA? A Matched Controlled Study
Background: Some researchers have suggested that achieving good component coverage over the host bone during TKA (while avoiding implant overhang) may help achieve durable implant fixation and may be associated with better outcomes scores. However, the evidence about this is limited and contradictory. Contemporary morphometric TKA includes a wide array of components with various shapes and sizes, based on large anatomic databases and specific software that simulates bone cuts. Morphometric tibial components have shown improved bone coverage and better clinical outcomes than standardized implants, but the role of morphometric femoral components in bone coverage has not been studied precisely. Questions/purposes: In a retrospective, controlled study that used patient matching, we asked: (1) Does the use of a contemporary morphometric component with more available sizes provide better femoral component fit and bone coverage than an earlier design with fewer sizes? (2) Are component fit and the presence of component overhang or underhang associated with different Knee Society Score (KSS) or Knee Injury and Osteoarthritis Outcome Score (KOOS) for Joint Replacement? Methods: From 2012 to 2013, we performed 403 TKAs according to the following criteria: TKA performed for primary tricompartmental arthritis of the knee; varus, valgus, and flexion deformity less than 15°; and age between 18 and 85 years on the day of surgery. Among these 403 TKAs, 237 were performed using a morphometric implant and 166 with the earlier nonmorphometric implant. At 2 years of follow-up, 3% of patients in the morphometric group and 5% in the nonmorphometric group were lost to follow-up. Based on age, BMI, gender, and preoperative KSS and KOOS, two groups of 30 patients were matched in a 1:1 ratio from this longitudinally maintained database. Clinical outcomes were measured preoperatively and at a minimum follow-up of 2 years in both groups, using the KSS and KOOS. We evaluated postoperative CT images for each patient to analyze femoral implant rotation, bone coverage, and overhang and underhang status. Results: The overhang status was similar between the two groups (23% had an overhang component in the morphometric knee group and 27% had an overhang component in the nonmorphometric knee group), and overhang was most frequently found in the lateral distal zone and medial anterior chamfer. Better cortical bone coverage was found in the morphometric knee group, with a thinner bone margin between the component edge and cortical border (morphometric group: 3 mm versus nonmorphometric knee group: 5 mm; p = 0.01). In general, there were few between-group differences in terms of patient-reported outcomes; of the seven metrics we analyzed, only the KSS favored the morphometric knee implant by a margin larger than the minimum clinically important difference (KSS mean difference: 21 points for the morphometric knee group; p < 0.05). Overhang of the femoral component of > 2 mm was associated with poorer KOOS, but not KSS, whereas a thinner bone margin had a beneficial impact on pain and global clinical scores (KOOS and KSS: p < 0.05). Conclusion: The use of a morphometric femoral component design showed slightly improved bone fit and pain score according to the KSS at midterm follow-up compared with earlier implants with fewer sizes. Overhang > 2 mm was associated with worse KOOS. The tendency toward better outcomes in morphometric implants warrants longer-term evaluation before any definite conclusions about the association between bone fit and clinical results can be drawn. Level of Evidence Level III, therapeutic study.
- Open Access
- 21 September 2022
- Published by Wiley in Arthroscopy Techniques
- Vol. 11 (9) , E1605-E1612
Anterior Closing‐Wedge High Tibial Osteotomy Using Patient‐Specific Cutting Guide in Chronic Anterior Cruciate Ligament–Deficient Knees
An increased posterior tibial slope has been identified as an independent risk factor for anterior cruciate ligament (ACL) graft rupture, with a critical threshold of 12°. Surgical slope correction by anterior closing wedge (ACW)‐high tibial osteotomy (HTO) can reduce ACL force and anterior tibial translation with good clinical outcomes when combined with revision ACL reconstruction. Performing ACW‐HTO preserving the tibial tubercule can be challenging for inexperienced surgeons. Patient‐specific cutting guides have been shown to be effective in facilitating the surgeon's learning curve in medial opening wedge‐HTO by reducing operative time and the use of fluoroscopy as well as decreasing anxiety. The present technique describes a retro‐tibial tubercule ACW‐HTO using a patient‐specific cutting guide. Technique Video: video See video under supplementary data.
- 21 September 2022
- Published by Wiley in Arthroscopy Techniques
- Vol. 11 (9) , E1605-E1612
Open AccessAnterior Closing‐Wedge High Tibial Osteotomy Using Patient‐Specific Cutting Guide in Chronic Anterior Cruciate Ligament–Deficient Knees
An increased posterior tibial slope has been identified as an independent risk factor for anterior cruciate ligament (ACL) graft rupture, with a critical threshold of 12°. Surgical slope correction by anterior closing wedge (ACW)‐high tibial osteotomy (HTO) can reduce ACL force and anterior tibial translation with good clinical outcomes when combined with revision ACL reconstruction. Performing ACW‐HTO preserving the tibial tubercule can be challenging for inexperienced surgeons. Patient‐specific cutting guides have been shown to be effective in facilitating the surgeon's learning curve in medial opening wedge‐HTO by reducing operative time and the use of fluoroscopy as well as decreasing anxiety. The present technique describes a retro‐tibial tubercule ACW‐HTO using a patient‐specific cutting guide. Technique Video: video See video under supplementary data.
- Open Access
- 1 May 2021
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 9 (5)
Incidence and Risk Factors for Residual High-Grade Pivot Shift After ACL Reconstruction With or Without a Lateral Extra-articular Tenodesis
Residual rotatory knee laxity at midterm follow-up after isolated anterior cruciate ligament reconstruction (ACLR) versus ACLR with lateral extra-articular tenodesis (LET) remains an issue. To evaluate the outcomes of ACLR with or without additional LET at a minimum 2-year follow-up in patients with preoperative high-grade pivot shift (PS). Our hypothesis was that the addition of LET would decrease the risk of secondary meniscal injury and the presence of residual high-grade PS at follow-up. Cohort study; Level of evidence, 3. A retrospective analysis performed at 3 sports medicine centers identified 266 study patients; all had a high-grade PS (grade 2 or 3) preoperatively and underwent isolated ACLR with or without LET. Four different ACLR techniques were used: single-strand quadrupled semitendinosus (ST4) ACLR without LET (ST4 group; n = 55), ST4 with anatomic LET (ST4+LET group; n = 77), bone–patellar tendon and modified Lemaire LET (BTB+LET group; n = 43), and quadriceps tendon and modified Lemaire LET (QT+LET group; n = 91). At follow-up, we evaluated for the presence of high-grade (grade ≥2) PS. Preoperative meniscal tears and their treatment were recorded. Overall, 185 (69.5%) patients had at least 1 meniscal tear at index surgery. The mean follow-up period was 44.3 months; 47 (17.7%) patients had a new meniscal tear and 64 (24%) patients had a high-grade PS at follow-up. Compared with meniscal repair, significant predictors for high-grade PS at follow-up were meniscectomy (odds ratio [OR] = 2.65 [95% CI, 1.19-5.63]; P = .02) and nonrepair of preoperative meniscal tear (OR = 3.26 [95% CI, 1.27-9.43]; P = .007). The appearance of a new symptomatic meniscal tear was the strongest significant predictor of high-grade PS at follow-up (OR = 4.31 [95% CI, 2.31-8.06]; P < .001). No significant correlation was observed between the addition of LET and the presence of high-grade PS at follow-up. In the current study, 1 in 4 patients with high-grade PS before ACLR with or without LET was at risk of residual rotatory knee laxity at mean 44-month follow-up, regardless of the technique used. Repairing a pre-existing meniscal lesion was more effective than performing LET to decrease the presence of a high-grade PS at follow-up.
- 1 May 2021
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 9 (5)
Open AccessIncidence and Risk Factors for Residual High-Grade Pivot Shift After ACL Reconstruction With or Without a Lateral Extra-articular Tenodesis
Residual rotatory knee laxity at midterm follow-up after isolated anterior cruciate ligament reconstruction (ACLR) versus ACLR with lateral extra-articular tenodesis (LET) remains an issue. To evaluate the outcomes of ACLR with or without additional LET at a minimum 2-year follow-up in patients with preoperative high-grade pivot shift (PS). Our hypothesis was that the addition of LET would decrease the risk of secondary meniscal injury and the presence of residual high-grade PS at follow-up. Cohort study; Level of evidence, 3. A retrospective analysis performed at 3 sports medicine centers identified 266 study patients; all had a high-grade PS (grade 2 or 3) preoperatively and underwent isolated ACLR with or without LET. Four different ACLR techniques were used: single-strand quadrupled semitendinosus (ST4) ACLR without LET (ST4 group; n = 55), ST4 with anatomic LET (ST4+LET group; n = 77), bone–patellar tendon and modified Lemaire LET (BTB+LET group; n = 43), and quadriceps tendon and modified Lemaire LET (QT+LET group; n = 91). At follow-up, we evaluated for the presence of high-grade (grade ≥2) PS. Preoperative meniscal tears and their treatment were recorded. Overall, 185 (69.5%) patients had at least 1 meniscal tear at index surgery. The mean follow-up period was 44.3 months; 47 (17.7%) patients had a new meniscal tear and 64 (24%) patients had a high-grade PS at follow-up. Compared with meniscal repair, significant predictors for high-grade PS at follow-up were meniscectomy (odds ratio [OR] = 2.65 [95% CI, 1.19-5.63]; P = .02) and nonrepair of preoperative meniscal tear (OR = 3.26 [95% CI, 1.27-9.43]; P = .007). The appearance of a new symptomatic meniscal tear was the strongest significant predictor of high-grade PS at follow-up (OR = 4.31 [95% CI, 2.31-8.06]; P < .001). No significant correlation was observed between the addition of LET and the presence of high-grade PS at follow-up. In the current study, 1 in 4 patients with high-grade PS before ACLR with or without LET was at risk of residual rotatory knee laxity at mean 44-month follow-up, regardless of the technique used. Repairing a pre-existing meniscal lesion was more effective than performing LET to decrease the presence of a high-grade PS at follow-up.
- Open Access
- 30 January 2021
- Published by Wiley in Arthroscopy Techniques
- Vol. 10 (2) , e419-e422
Soft‐Tissue Management and Neurovascular Protection During Opening‐Wedge High Tibial Osteotomy
Medial opening‐wedge high tibial osteotomy (OW‐HTO) is an excellent surgical option for patients with varus knee osteoarthritis. Medial collateral ligament (MCL) release and posterior neurovascular structure protection during OW‐HTO are steps that often induce stress and nervousness during surgery, especially for surgeons in the earlier stages of their learning curve. While is it well‐known that the MCL should be released during OW‐HTO, the standard retraction techniques pose challenges in visualization and instrument placement in the surgical field. We present our technique, which illustrates an alternative method to manage the MCL and safely protect the neurovascular structures using a second and more posterior surgical window during OW‐HTO. Technique Video: video See video under supplementary data.
- 30 January 2021
- Published by Wiley in Arthroscopy Techniques
- Vol. 10 (2) , e419-e422
Open AccessSoft‐Tissue Management and Neurovascular Protection During Opening‐Wedge High Tibial Osteotomy
Medial opening‐wedge high tibial osteotomy (OW‐HTO) is an excellent surgical option for patients with varus knee osteoarthritis. Medial collateral ligament (MCL) release and posterior neurovascular structure protection during OW‐HTO are steps that often induce stress and nervousness during surgery, especially for surgeons in the earlier stages of their learning curve. While is it well‐known that the MCL should be released during OW‐HTO, the standard retraction techniques pose challenges in visualization and instrument placement in the surgical field. We present our technique, which illustrates an alternative method to manage the MCL and safely protect the neurovascular structures using a second and more posterior surgical window during OW‐HTO. Technique Video: video See video under supplementary data.
- Open Access
- 30 January 2021
- Published by Wiley in Arthroscopy Techniques
- Vol. 10 (2) , e431-e435
Minimally Invasive High Tibial Osteotomy Using a Patient‐Specific Cutting Guide
Medial opening wedge high tibial osteotomy (OW‐HTO) is an excellent surgical option for patients with varus knee osteoarthritis. This article presents a technique of performing a minimally invasive OW‐HTO using a patient‐specific cutting guide (PSCG). Preoperative 3‐dimensional planning with computed tomography imaging is essential. The correction parameters, the final plate position, as well as the 3‐dimensional position of the hinge as well as wedge are verified preoperatively before the PSCG is produced. After exposure with an oblique incision over the posteromedial tibia, the hamstring tendons are released for later re‐attachment and the medial collateral ligament is released slightly. The PSCG is then used to perform the OW‐HTO with protection of the posterior neurovascular structures by a retractor placed posterior to the medial collateral ligament. The final fixation of the osteotomy is achieved with a low‐profile locking plate and a femoral head allograft wedge. Technique Video: video See video under supplementary data.
- 30 January 2021
- Published by Wiley in Arthroscopy Techniques
- Vol. 10 (2) , e431-e435
Open AccessMinimally Invasive High Tibial Osteotomy Using a Patient‐Specific Cutting Guide
Medial opening wedge high tibial osteotomy (OW‐HTO) is an excellent surgical option for patients with varus knee osteoarthritis. This article presents a technique of performing a minimally invasive OW‐HTO using a patient‐specific cutting guide (PSCG). Preoperative 3‐dimensional planning with computed tomography imaging is essential. The correction parameters, the final plate position, as well as the 3‐dimensional position of the hinge as well as wedge are verified preoperatively before the PSCG is produced. After exposure with an oblique incision over the posteromedial tibia, the hamstring tendons are released for later re‐attachment and the medial collateral ligament is released slightly. The PSCG is then used to perform the OW‐HTO with protection of the posterior neurovascular structures by a retractor placed posterior to the medial collateral ligament. The final fixation of the osteotomy is achieved with a low‐profile locking plate and a femoral head allograft wedge. Technique Video: video See video under supplementary data.
- Open Access
- 2 August 2020
- Published by Wiley in Arthroscopy Techniques
- Vol. 9 (8) , E1101-E1108
Posteromedial Opening‐Wedge Tibial Osteotomy for Metaphyseal Varus and Abnormal Posterior Slope Correction in Failed Anterior Cruciate Ligament Reconstructions Using a Custom Cutting Guide
Anterior cruciate ligament reconstruction after graft failure may need associated bone correction to ensure stability of the knee. This article presents a technique of posteromedial opening‐wedge osteotomy using a custom cutting guide to correct increased tibial slope and metaphyseal varus deformity after recurrent graft failure. An autograft quadriceps tendon graft was selected for the revision anterior cruciate ligament graft. After exposure with an anteromedial incision a patient specific cutting guide was used to make the high tibial osteotomy. The final fixation of the posteromedial opening was achieved using a low‐profile locking plate and a femoral head allograft bone wedge. The tibial tunnel was planned and included in the patient‐specific cutting guide. The femoral tunnel was placed using an outside to in manner. Bioabsorbable screws were used as fixation devices. Technique Video: video See video under supplementary data.
- 2 August 2020
- Published by Wiley in Arthroscopy Techniques
- Vol. 9 (8) , E1101-E1108
Open AccessPosteromedial Opening‐Wedge Tibial Osteotomy for Metaphyseal Varus and Abnormal Posterior Slope Correction in Failed Anterior Cruciate Ligament Reconstructions Using a Custom Cutting Guide
Anterior cruciate ligament reconstruction after graft failure may need associated bone correction to ensure stability of the knee. This article presents a technique of posteromedial opening‐wedge osteotomy using a custom cutting guide to correct increased tibial slope and metaphyseal varus deformity after recurrent graft failure. An autograft quadriceps tendon graft was selected for the revision anterior cruciate ligament graft. After exposure with an anteromedial incision a patient specific cutting guide was used to make the high tibial osteotomy. The final fixation of the posteromedial opening was achieved using a low‐profile locking plate and a femoral head allograft bone wedge. The tibial tunnel was planned and included in the patient‐specific cutting guide. The femoral tunnel was placed using an outside to in manner. Bioabsorbable screws were used as fixation devices. Technique Video: video See video under supplementary data.
- 27 April 2020
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 29 (3) , 820-826
Evaluation of the “Minimal Clinically Important Difference” (MCID) of the KOOS, KSS and SF‐12 scores after open‐wedge high tibial osteotomy
Purpose: Defining a Minimal Clinically Important Difference (MCID) value for Patient‐Reported Outcome Measures (PROMs) is crucial for determining the effectiveness of a procedure and calculating the sample size for trial planning. The purpose of this study was to determine the MCID of several PROMs (Knee injury and Osteoarthritis Outcome Score (KOOS), Knee Society Score (KSS) and the SF‐12) in patients who underwent medial opening‐wedge High‐Tibial Osteotomy (owHTO) with Patient‐Specific Cutting Guides (PSCGs), using anchor‐based methods.Methods: Patients undergoing isolated medial owHTO with PSCGs between January 2013 and January 2017 were enrolled in this single‐center, prospective, observational study. Three outcome scores were collected pre‐operatively and at the 2 years follow‐up evaluation: KOOS, KSS and SF‐12. The MCIDs were calculated using anchor‐based method: at 2 years postoperatively: “Compared with before surgery, how would you rate operated joint now?” The responses were recorded using a five‐point scale. Patients who answered “about the same” or “somewhat worse” were classified into the no change group, while those who answered “somewhat better” were classified into the minimal change group. A receiver operating characteristic (ROC) curve was used to define the cutoff point that best discriminated between the minimal change and no change groups for each PROMsResults: 196 patients were included, 75 (somewhat better) and 24 patients (about the same and somewhat worse) were, respectively, assigned to the “no change” and “minimal change” groups. There was no significant difference between the two groups in terms of baseline characteristics and postoperative complications. At 24 months follow‐up all the PROMs (KOOS, KSS and SF‐12) were significantly better for the “minimal change” group compared to the “no change” group. MCID was 15.4 for KOOS pain, 15.1 for KOOS symptoms, 17 for KOOS ADL, 11.2 for KOOS sports/recreation, 16.5 for KOOS QQL, 3 for KSS symptoms, 5.6 for KSS activity, 7.2 for SF‐12 physical component and 6.3 for PCS mental component.Conclusion: This study determined the MCIDs of common used PROMs in patients undergoing owHTO.Level of evidence: Prospective Cohort Study, Level II
- 27 April 2020
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 29 (3) , 820-826
Evaluation of the “Minimal Clinically Important Difference” (MCID) of the KOOS, KSS and SF‐12 scores after open‐wedge high tibial osteotomy
Purpose: Defining a Minimal Clinically Important Difference (MCID) value for Patient‐Reported Outcome Measures (PROMs) is crucial for determining the effectiveness of a procedure and calculating the sample size for trial planning. The purpose of this study was to determine the MCID of several PROMs (Knee injury and Osteoarthritis Outcome Score (KOOS), Knee Society Score (KSS) and the SF‐12) in patients who underwent medial opening‐wedge High‐Tibial Osteotomy (owHTO) with Patient‐Specific Cutting Guides (PSCGs), using anchor‐based methods.Methods: Patients undergoing isolated medial owHTO with PSCGs between January 2013 and January 2017 were enrolled in this single‐center, prospective, observational study. Three outcome scores were collected pre‐operatively and at the 2 years follow‐up evaluation: KOOS, KSS and SF‐12. The MCIDs were calculated using anchor‐based method: at 2 years postoperatively: “Compared with before surgery, how would you rate operated joint now?” The responses were recorded using a five‐point scale. Patients who answered “about the same” or “somewhat worse” were classified into the no change group, while those who answered “somewhat better” were classified into the minimal change group. A receiver operating characteristic (ROC) curve was used to define the cutoff point that best discriminated between the minimal change and no change groups for each PROMsResults: 196 patients were included, 75 (somewhat better) and 24 patients (about the same and somewhat worse) were, respectively, assigned to the “no change” and “minimal change” groups. There was no significant difference between the two groups in terms of baseline characteristics and postoperative complications. At 24 months follow‐up all the PROMs (KOOS, KSS and SF‐12) were significantly better for the “minimal change” group compared to the “no change” group. MCID was 15.4 for KOOS pain, 15.1 for KOOS symptoms, 17 for KOOS ADL, 11.2 for KOOS sports/recreation, 16.5 for KOOS QQL, 3 for KSS symptoms, 5.6 for KSS activity, 7.2 for SF‐12 physical component and 6.3 for PCS mental component.Conclusion: This study determined the MCIDs of common used PROMs in patients undergoing owHTO.Level of evidence: Prospective Cohort Study, Level II
- 15 April 2020
- Published by Wiley in Arthroscopy
- Vol. 36 (8) , 2231-2236
Presoaking of Semitendinosus Graft With Vancomycin Does Not Alter Its Biomechanical Properties: A Biomechanical In Vitro–Controlled Study Using Graft From Living Donors
Purpose: To compare the biomechanical properties of human semitendinosus graft presoaked with or without vancomycin under a load to failure tensile test. Methods: Thirty semitendinosus grafts harvested during anterior cruciate ligament reconstruction were included. These were dissected equally into 2 halves and subsequently randomly allocated to a vancomycin group and to a control group. A digital caliper was used to precisely measure each samples thickness, length, and width. For the vancomycin group, samples were presoaked in a solution of 5 mg/mL vancomycin for a duration of 10 minutes and the control group samples were presoaked in a physiological serum equally for 10 minutes. Mechanical testing was performed on a universal testing machine (Instron 5566‐A) after a preconditioning of 10 cycles of 1 mm extension and a progression of 10 mm/min to failure for each sample. The stress–strain curve was obtained to determine the elastic modulus (Young’s modulus), the ultimate tensile stress, the ultimate tensile elongation (UTE) before failure and the elasticity limit. Results: For the control group, the average Young’s modulus value was 4.8 ± 0.8, the average UTS was 25.2 ± 5.2 MPa, the average percentage of UTE was 78 ± 17%, and the average elasticity limit value was 17.3 ± 5.3 MPa. For the vancomycin group, the average Young’s modulus value was 4.7 ± 0.9, the average ultimate tensile stress was 24.1 ± 6.1 MPa, the average percentage of UTE was 82 ± 14%, and the average elasticity limit value was 18.5 ± 5.9 MPa. No significant difference was observed between the 2 groups for all investigated parameters. Conclusions: Presoaking of human semitendinosus graft with vancomycin does not alter its biomechanical properties. Clinical relevance: This study demonstrates that vancomycin presoaking used to prevent post‐anterior cruciate ligament reconstruction septic arthritis does not affect immediate biomechanical properties of semitendinosus tendons.
- 15 April 2020
- Published by Wiley in Arthroscopy
- Vol. 36 (8) , 2231-2236
Presoaking of Semitendinosus Graft With Vancomycin Does Not Alter Its Biomechanical Properties: A Biomechanical In Vitro–Controlled Study Using Graft From Living Donors
Purpose: To compare the biomechanical properties of human semitendinosus graft presoaked with or without vancomycin under a load to failure tensile test. Methods: Thirty semitendinosus grafts harvested during anterior cruciate ligament reconstruction were included. These were dissected equally into 2 halves and subsequently randomly allocated to a vancomycin group and to a control group. A digital caliper was used to precisely measure each samples thickness, length, and width. For the vancomycin group, samples were presoaked in a solution of 5 mg/mL vancomycin for a duration of 10 minutes and the control group samples were presoaked in a physiological serum equally for 10 minutes. Mechanical testing was performed on a universal testing machine (Instron 5566‐A) after a preconditioning of 10 cycles of 1 mm extension and a progression of 10 mm/min to failure for each sample. The stress–strain curve was obtained to determine the elastic modulus (Young’s modulus), the ultimate tensile stress, the ultimate tensile elongation (UTE) before failure and the elasticity limit. Results: For the control group, the average Young’s modulus value was 4.8 ± 0.8, the average UTS was 25.2 ± 5.2 MPa, the average percentage of UTE was 78 ± 17%, and the average elasticity limit value was 17.3 ± 5.3 MPa. For the vancomycin group, the average Young’s modulus value was 4.7 ± 0.9, the average ultimate tensile stress was 24.1 ± 6.1 MPa, the average percentage of UTE was 82 ± 14%, and the average elasticity limit value was 18.5 ± 5.9 MPa. No significant difference was observed between the 2 groups for all investigated parameters. Conclusions: Presoaking of human semitendinosus graft with vancomycin does not alter its biomechanical properties. Clinical relevance: This study demonstrates that vancomycin presoaking used to prevent post‐anterior cruciate ligament reconstruction septic arthritis does not affect immediate biomechanical properties of semitendinosus tendons.