Yoke Rung Wong
Research Subjects
Yoke Rung Wong has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Duncan Angus McGrouther
Biomechanics Laboratory, Singapore General Hospital, Singapore
1 shared publication- Duncan Angus McGrouther
Department of Hand and Reconstructive Microsurgery, Singapore General Hospital, Singapore
1 shared publication Hwa Liang Leo
Department of Biomedical Engineering, National University of Singapore, Singapore
1 shared publicationJoachim Ee En Ong
Department of Mechanical Engineering, National University of Singapore, Singapore
1 shared publicationMin Kai Chang
Duke-NUS Medical School, Singapore, 8 College Road, Singapore 169867, Singapore
1 shared publicationShi Lei Teng
Biomechanics Laboratory, Singapore General Hospital, Singapore
1 shared publication
Latest Publications
- Open Access
- 1 March 2023
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 109 (3) , 481-490
Biomechanics of surgical knot security: a systematic review
Background: This review aims to identify publications on quantitative biomechanical testing of surgical knot security and the physical factors that determine knot security and failure. Materials and Methods: An electronic literature search was performed in accordance with PRISMA guidelines in January 2022 utilizing the PubMed and Google Scholar databases to look for objective biomechanical studies on knot security in surgery using the primary terms ‘knot security’ and ‘biomechanical testing’. Results: Thirty-six articles were included. Twenty-four configurations of surface, laparoscopic, and arthroscopic knots were studied. Biomechanical tensile testing was used to evaluate knot security in vitro. Load to failure (N) and elongation at knot failure (mm) were quantified by static and cyclic testing to evaluate the knot holding capacity and failure mechanism of slippage or rupture. Conclusion: This review reassures that the knot configuration, suture materials, suture sizes, and number of throws are key factors in determining the knot’s security. Knot configuration has to be simple for laparoscopic and arthroscopic knots due to the confined space of the operating site. With the advent of stronger suture materials for high-tension surgical reconstructive procedures, there is an unmet need to understand the physical behavior of the knot and the factors that determine its resistance to slippage or rupture. Level of Evidence: Level IV.
- 1 March 2023
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 109 (3) , 481-490
Open AccessBiomechanics of surgical knot security: a systematic review
Background: This review aims to identify publications on quantitative biomechanical testing of surgical knot security and the physical factors that determine knot security and failure. Materials and Methods: An electronic literature search was performed in accordance with PRISMA guidelines in January 2022 utilizing the PubMed and Google Scholar databases to look for objective biomechanical studies on knot security in surgery using the primary terms ‘knot security’ and ‘biomechanical testing’. Results: Thirty-six articles were included. Twenty-four configurations of surface, laparoscopic, and arthroscopic knots were studied. Biomechanical tensile testing was used to evaluate knot security in vitro. Load to failure (N) and elongation at knot failure (mm) were quantified by static and cyclic testing to evaluate the knot holding capacity and failure mechanism of slippage or rupture. Conclusion: This review reassures that the knot configuration, suture materials, suture sizes, and number of throws are key factors in determining the knot’s security. Knot configuration has to be simple for laparoscopic and arthroscopic knots due to the confined space of the operating site. With the advent of stronger suture materials for high-tension surgical reconstructive procedures, there is an unmet need to understand the physical behavior of the knot and the factors that determine its resistance to slippage or rupture. Level of Evidence: Level IV.
- 1 August 2022
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 26 (9) , 1077-1085
A fluid-structure interaction investigation of intra-articular pressure and ligament in wrist joint
Understanding the stresses on the scapholunate interosseous ligament (SLIL) and its interaction with synovial fluid pressure could be vital to improve wrist treatment for various wrist conditions such as arthritis, sprains and tendonitis. This study investigated the interaction between the intra-articular pressure, specifically the synovial fluid pressure change and the SLIL stresses in a computational model during wrist radioulnar deviation (RUD). Magnetic resonance imaging (MRI) scans were used to acquire the anatomical model of the carpal bones and ligament, while the kinematics of scaphoid and lunate were obtained through dynamic computerized tomography (CT) scans. A two-way fluid–structure interaction (FSI) was used to model the dynamics between the scaphoid and lunate, the SLIL, and the synovial fluid. The synovial fluid pressure change was found to be small (−4.86 to 3.23 Pa) and close to that simulated in a previous work without the SLIL (−1.68 to 2.64 Pa). Furthermore, peaks of maximum fluid pressure were found to trail the peaks of ligament stress. Therefore, it is suggested that the influence of synovial fluid pressure on the ligament in the SLIL model is negligible and simulations of the scapholunate joint could forego fluid-structure interactions. Future studies can instead explore other structures in the carpus that can possibly contribute to the ligament stresses. Clinically, treatments can be targeted at these areas to help prevent or slow the progression of ligament injuries into serious consequences like the degenerative joint disease.
- 1 August 2022
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 26 (9) , 1077-1085
A fluid-structure interaction investigation of intra-articular pressure and ligament in wrist joint
Understanding the stresses on the scapholunate interosseous ligament (SLIL) and its interaction with synovial fluid pressure could be vital to improve wrist treatment for various wrist conditions such as arthritis, sprains and tendonitis. This study investigated the interaction between the intra-articular pressure, specifically the synovial fluid pressure change and the SLIL stresses in a computational model during wrist radioulnar deviation (RUD). Magnetic resonance imaging (MRI) scans were used to acquire the anatomical model of the carpal bones and ligament, while the kinematics of scaphoid and lunate were obtained through dynamic computerized tomography (CT) scans. A two-way fluid–structure interaction (FSI) was used to model the dynamics between the scaphoid and lunate, the SLIL, and the synovial fluid. The synovial fluid pressure change was found to be small (−4.86 to 3.23 Pa) and close to that simulated in a previous work without the SLIL (−1.68 to 2.64 Pa). Furthermore, peaks of maximum fluid pressure were found to trail the peaks of ligament stress. Therefore, it is suggested that the influence of synovial fluid pressure on the ligament in the SLIL model is negligible and simulations of the scapholunate joint could forego fluid-structure interactions. Future studies can instead explore other structures in the carpus that can possibly contribute to the ligament stresses. Clinically, treatments can be targeted at these areas to help prevent or slow the progression of ligament injuries into serious consequences like the degenerative joint disease.
- 1 February 2019
- Published by Elsevier in Clinical Biomechanics
- Vol. 62, 42-49
A review of cyclic testing protocols for flexor tendon repairs
- 1 February 2019
- Published by Elsevier in Clinical Biomechanics
- Vol. 62, 42-49
A review of cyclic testing protocols for flexor tendon repairs