Tobias Fusswinkel
Research Subjects
Research Interests
Tobias Fusswinkel has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Wagner
University of Helsinki
10 shared publications Thomas Wenzel
4 shared publicationsGregor Markl
3 shared publicationsMarkus Wälle
3 shared publications- Benjamin F. Walter
Eberhard Karls University Tübingen Petrology and Mineral Resources Schnarrenbergstrasse 94‐96 Tübingen 72074 Germany
2 shared publications - Christoph A. Heinrich
Institute of Geochemistry and Petrology, ETH Zürich, 8092 Zürich, Switzerland
2 shared publications
Latest Publications
- 20 June 2022
- Published by Walter de Gruyter GmbH
- p. 371-398
12 Analysis of rare earth elements in rock and mineral samples by ICP-MS and LA-ICP-MS
The group of the REE serves as valuable indicator of numerous geological processes such as magma formation or fluid-rock interaction. The decay systems of the radioactive REE isotopes 138La, 147Sm and 176Lu are used for geochronometric dating of a range of events, starting from first steps of planetary formation to younger stages of geodynamic development. Thus, the abundance of all REE occurring in a large range of concentrations as well as precise isotope ratios must be analysed in different geomaterials. The inductively coupled plasma (ICP) ion source and various types of mass spectrometers (MS) represent the basis to fulfil the analytical requirements of geoscientific studies. Today, ICP-quadrupole MS (QMS), ICP-sector field MS (SF-MS) with a single detector or multiple ion collection (MC-ICP-MS) are standard instruments for REE analyses in the geosciences. Due to a need for in situ analysis, laser ablation (LA) -ICP-MS has become an important trace element microprobe technique, which is widely applied for determination of REE concentrations and isotope compositions in geoscientific laboratories. The quality of concentration analysis or isotope ratio determination of the REE by ICP-MS and LA-ICP-MS is affected by many parameters. Most significant are interferences caused by polyatomic oxide and hydroxide ion species formed in the plasma as well as fractionation effects leading to non-stoichiometric behaviour during element determination or to biased isotope ratio measurements. Laser induced fractionation and isobaric interferences have to be considered as additional effects for LA-ICP-MS. As analyte elements and matrix are unseparated mineral standards matching the matrix of samples are a prerequisite for accurate and precise REE concentration and isotope ratio determination. Application of fs-lasers instead of the more common ns-lasers in LA-ICP-MS systems turns out to be a significant step to reduce laser induced fractionation and to overcome effects of sample matrices.
- 20 June 2022
- Published by Walter de Gruyter GmbH
- p. 371-398
12 Analysis of rare earth elements in rock and mineral samples by ICP-MS and LA-ICP-MS
The group of the REE serves as valuable indicator of numerous geological processes such as magma formation or fluid-rock interaction. The decay systems of the radioactive REE isotopes 138La, 147Sm and 176Lu are used for geochronometric dating of a range of events, starting from first steps of planetary formation to younger stages of geodynamic development. Thus, the abundance of all REE occurring in a large range of concentrations as well as precise isotope ratios must be analysed in different geomaterials. The inductively coupled plasma (ICP) ion source and various types of mass spectrometers (MS) represent the basis to fulfil the analytical requirements of geoscientific studies. Today, ICP-quadrupole MS (QMS), ICP-sector field MS (SF-MS) with a single detector or multiple ion collection (MC-ICP-MS) are standard instruments for REE analyses in the geosciences. Due to a need for in situ analysis, laser ablation (LA) -ICP-MS has become an important trace element microprobe technique, which is widely applied for determination of REE concentrations and isotope compositions in geoscientific laboratories. The quality of concentration analysis or isotope ratio determination of the REE by ICP-MS and LA-ICP-MS is affected by many parameters. Most significant are interferences caused by polyatomic oxide and hydroxide ion species formed in the plasma as well as fractionation effects leading to non-stoichiometric behaviour during element determination or to biased isotope ratio measurements. Laser induced fractionation and isobaric interferences have to be considered as additional effects for LA-ICP-MS. As analyte elements and matrix are unseparated mineral standards matching the matrix of samples are a prerequisite for accurate and precise REE concentration and isotope ratio determination. Application of fs-lasers instead of the more common ns-lasers in LA-ICP-MS systems turns out to be a significant step to reduce laser induced fractionation and to overcome effects of sample matrices.
- Open Access
- 9 June 2022
- Published by Geological Society of America
Supplemental Material: Halogen ratios in crustal fluids through time—Proxies for the emergence of aerobic life?
Results and analytical protocols.
- 9 June 2022
- Published by Geological Society of America
Open AccessSupplemental Material: Halogen ratios in crustal fluids through time—Proxies for the emergence of aerobic life?
Results and analytical protocols.
- Open Access
- 9 June 2022
- Published by Geological Society of America
Supplemental Material: Halogen ratios in crustal fluids through time—Proxies for the emergence of aerobic life?
Results and analytical protocols.
- 9 June 2022
- Published by Geological Society of America
Open AccessSupplemental Material: Halogen ratios in crustal fluids through time—Proxies for the emergence of aerobic life?
Results and analytical protocols.
- 1 August 2020
- Published by Elsevier in Chemical Geology
- Vol. 548
Fluorite as indicator mineral in iron oxide-copper-gold systems: explaining the IOCG deposit diversity
- 1 August 2020
- Published by Elsevier in Chemical Geology
- Vol. 548
Fluorite as indicator mineral in iron oxide-copper-gold systems: explaining the IOCG deposit diversity
- 8 March 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 33 (5) , 768-783
Combined LA-ICP-MS microanalysis of iodine, bromine and chlorine in fluid inclusions
Halogens are excellent tracers of hydrothermal fluid sources in sedimentary, magmatic, metamorphic and ore-forming environments. In situ LA-ICP-MS analysis of Cl and Br in single fluid inclusions has provided fundamentally new insight into the processes leading to the formation of economic mineral deposits. Enrichment and depletion of Br relative to the dominant halogen Cl may be caused by several processes besides seawater evaporation and halite dissolution, which cannot be unequivocally resolved on the basis of Br/Cl ratios alone. Triple-halogen analysis (Cl, Br and I) would provide the required additional constraint permitting discrimination between possible alternative processes. We present the first iodine concentration data of fluid inclusions determined by LA-ICP-MS microanalysis, using the natural scapolite reference material Sca17 for external standardization. The robustness of the method is verified by LA-ICP-MS analysis of synthetic fluid inclusions, which were prepared at 600 °C, and 100 or 200 MPa in cold-seal pressure vessels from four starting solutions containing Na, Rb, Cs, Cl, Br and I. LA-ICP-MS analysis yielded average I concentrations in excellent agreement with the starting solutions. Average concentrations in inclusions synthesized from the solution with 27 μg g−1 I were 27.3 ± 3.9 μg g−1 I (14.3% RSD), and 77.6 ± 6.4 μg g−1 I (8.3% RSD) for the solution with 78 μg g−1 I. Chlorine and Br reference concentrations were reproduced to better than 10% and 20% RSD, respectively. The method was subsequently applied to a pilot study of natural fluid inclusion samples from three geological settings (Alpine metamorphic quartz veins, post-Variscan quartz-Pb–Zn veins, and calcite veins with Mn oxide and hematite mineralization). The data demonstrate significant differences between the samples, which can be interpreted in terms of Br and I enrichment due to reactions with organic matter and fluid mixing processes between evaporite brines and halite dissolution brines. This highlights the potential of triple-halogen LA-ICP-MS analysis in fluid inclusions for tracing the source of crustal fluids in a wide range of geological environments.
- 8 March 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 33 (5) , 768-783
Combined LA-ICP-MS microanalysis of iodine, bromine and chlorine in fluid inclusions
Halogens are excellent tracers of hydrothermal fluid sources in sedimentary, magmatic, metamorphic and ore-forming environments. In situ LA-ICP-MS analysis of Cl and Br in single fluid inclusions has provided fundamentally new insight into the processes leading to the formation of economic mineral deposits. Enrichment and depletion of Br relative to the dominant halogen Cl may be caused by several processes besides seawater evaporation and halite dissolution, which cannot be unequivocally resolved on the basis of Br/Cl ratios alone. Triple-halogen analysis (Cl, Br and I) would provide the required additional constraint permitting discrimination between possible alternative processes. We present the first iodine concentration data of fluid inclusions determined by LA-ICP-MS microanalysis, using the natural scapolite reference material Sca17 for external standardization. The robustness of the method is verified by LA-ICP-MS analysis of synthetic fluid inclusions, which were prepared at 600 °C, and 100 or 200 MPa in cold-seal pressure vessels from four starting solutions containing Na, Rb, Cs, Cl, Br and I. LA-ICP-MS analysis yielded average I concentrations in excellent agreement with the starting solutions. Average concentrations in inclusions synthesized from the solution with 27 μg g−1 I were 27.3 ± 3.9 μg g−1 I (14.3% RSD), and 77.6 ± 6.4 μg g−1 I (8.3% RSD) for the solution with 78 μg g−1 I. Chlorine and Br reference concentrations were reproduced to better than 10% and 20% RSD, respectively. The method was subsequently applied to a pilot study of natural fluid inclusion samples from three geological settings (Alpine metamorphic quartz veins, post-Variscan quartz-Pb–Zn veins, and calcite veins with Mn oxide and hematite mineralization). The data demonstrate significant differences between the samples, which can be interpreted in terms of Br and I enrichment due to reactions with organic matter and fluid mixing processes between evaporite brines and halite dissolution brines. This highlights the potential of triple-halogen LA-ICP-MS analysis in fluid inclusions for tracing the source of crustal fluids in a wide range of geological environments.
- 1 March 2018
- Published by Elsevier in Journal of Geochemical Exploration
- Vol. 186, 158-186
Multi-reservoir fluid mixing processes in rift-related hydrothermal veins, Schwarzwald, SW-Germany
- 1 March 2018
- Published by Elsevier in Journal of Geochemical Exploration
- Vol. 186, 158-186
Multi-reservoir fluid mixing processes in rift-related hydrothermal veins, Schwarzwald, SW-Germany
- 1 December 2017
- Published by Elsevier in Ore Geology Reviews
- Vol. 91, 906-927
Major and trace element geochemistry of tourmalines from Archean orogenic gold deposits: Proxies for the origin of gold mineralizing fluids?
- 1 December 2017
- Published by Elsevier in Ore Geology Reviews
- Vol. 91, 906-927
Major and trace element geochemistry of tourmalines from Archean orogenic gold deposits: Proxies for the origin of gold mineralizing fluids?
- 1 September 2017
- Published by Elsevier in Chemical Geology
- Vol. 467, 134-142
High Ni and low Mn/Fe in olivine phenocrysts of the Karoo meimechites do not reflect pyroxenitic mantle sources
- 1 September 2017
- Published by Elsevier in Chemical Geology
- Vol. 467, 134-142
High Ni and low Mn/Fe in olivine phenocrysts of the Karoo meimechites do not reflect pyroxenitic mantle sources