Emanuele Tognoli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Emanuele Tognoli has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Silvio Defanti
Department of Engineering “Enzo Ferrari”, University of Modena and Reggio Emilia, Modena, Italy
6 shared publications - Andrea Gatto
Department of Engineering “Enzo Ferrari”, Università di Modena e Reggio Emilia, Via P. Vivarelli 10, 41125 Modena, Italy
5 shared publications - Lucia Denti
Department of Engineering “Enzo Ferrari”, Università di Modena e Reggio Emilia, Via P. Vivarelli 10, 41125 Modena, Italy
5 shared publications - Maria Laura Gatto
Department DIISM, Università Politecnica Delle Marche, Via Brecce Bianche 12, 60131, Ancona, Italy
5 shared publications - Paolo Mengucci
Department SIMAU & UdR INSTM, Università Politecnica Delle Marche, Via Brecce Bianche 12, 60131 Ancona, Italy
5 shared publications - Antonella Sola
Department of Sciences and Methods for Engineering, University of Modena and Reggio Emilia, Via Amendola 2, 42122 Reggio Emilia, Italy
3 shared publications
Latest Publications
- Open Access
Biconometric Connections in Dental Implants: A Pilot Mechanical Study
Background: In dental implants, micro-gaps at the fixation–abutment interface can cause peri-implantitis and/or loosening or loss of the fixation screw; therefore, three-dimensional imaging is widely used to examine different types of connections. In the present study, we focus on the analysis on biconometric connections to detect and (possibly) measure the presence of micro-gaps in the as-positioned state and after repeated loading and unloading. Methods: Seven biconometric dental implants were characterized using micro-computed tomography (micro-CT). In two specimens (group 1), the cap was inserted, and only the apical portion was imaged, to evaluate the cap–abutment connection; in the remaining five specimens (group 2), the fixture–abutment connection was analyzed. Two implants in group 2 were also subjected to load tests to verify whether stresses could induce the formation of micro-gaps as a consequence of preload loss. Results: Micro-CT analysis showed the absence of micro-gaps greater than 10 µm in both cap–abutment and abutment–fixture connections. This was verified, in the fixture–abutment connection, even after mechanical loading and unloading. The results were reproducible in all the investigated samples in the different experimental conditions. Conclusions: In the human force range during chewing, the conical connection showed a high level of resistance to micro-gap formation at the implant–abutment interface. The absence of micro-gaps, as demonstrated here, provides encouraging preliminary data regarding the stability of the biconometric connections, which will be further verified in follow-up studies on a larger sample size.
Open AccessBiconometric Connections in Dental Implants: A Pilot Mechanical Study
Background: In dental implants, micro-gaps at the fixation–abutment interface can cause peri-implantitis and/or loosening or loss of the fixation screw; therefore, three-dimensional imaging is widely used to examine different types of connections. In the present study, we focus on the analysis on biconometric connections to detect and (possibly) measure the presence of micro-gaps in the as-positioned state and after repeated loading and unloading. Methods: Seven biconometric dental implants were characterized using micro-computed tomography (micro-CT). In two specimens (group 1), the cap was inserted, and only the apical portion was imaged, to evaluate the cap–abutment connection; in the remaining five specimens (group 2), the fixture–abutment connection was analyzed. Two implants in group 2 were also subjected to load tests to verify whether stresses could induce the formation of micro-gaps as a consequence of preload loss. Results: Micro-CT analysis showed the absence of micro-gaps greater than 10 µm in both cap–abutment and abutment–fixture connections. This was verified, in the fixture–abutment connection, even after mechanical loading and unloading. The results were reproducible in all the investigated samples in the different experimental conditions. Conclusions: In the human force range during chewing, the conical connection showed a high level of resistance to micro-gap formation at the implant–abutment interface. The absence of micro-gaps, as demonstrated here, provides encouraging preliminary data regarding the stability of the biconometric connections, which will be further verified in follow-up studies on a larger sample size.
- 17 July 2024
- Published by Springer Nature in Meccanica
- Vol. 60 (3) , 633-646
Dimensional and mechanical assessment of gyroid lattices produced in aluminum by laser powder bed fusion
- 17 July 2024
- Published by Springer Nature in Meccanica
- Vol. 60 (3) , 633-646
Dimensional and mechanical assessment of gyroid lattices produced in aluminum by laser powder bed fusion
- 4 April 2024
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 9 (6) , 2413-2426
High-temperature tensile behavior of AlSi7Mg parts built by LPBF under high-productivity conditions
- 4 April 2024
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 9 (6) , 2413-2426
High-temperature tensile behavior of AlSi7Mg parts built by LPBF under high-productivity conditions
- Open Access
- 15 January 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (1) , 80
Features of Vat-Photopolymerized Masters for Microfluidic Device Manufacturing
The growing interest in advancing microfluidic devices for manipulating fluids within micrometer-scale channels has prompted a shift in manufacturing practices, moving from single-component production to medium-size batches. This transition arises due to the impracticality of lab-scale manufacturing methods in accommodating the increased demand. This experimental study focuses on the design of master benchmarks 1–5, taking into consideration critical parameters such as rib width, height, and the relative width-to-height ratio. Notably, benchmarks 4 and 5 featured ribs that were strategically connected to the inlet, outlet, and reaction chamber of the master, enhancing their utility for subsequent replica production. Vat photopolymerization was employed for the fabrication of benchmarks 1–5, while replicas of benchmarks 4 and 5 were generated through polydimethylsiloxane casting. Dimensional investigations of the ribs and channels in both the master benchmarks and replicas were conducted using an optical technique validated through readability analysis based on the Michelson global contrast index. The primary goal was to evaluate the potential applicability of vat photopolymerization technology for efficiently producing microfluidic devices through a streamlined production process. Results indicate that the combination of vat photopolymerization followed by replication is well suited for achieving a minimum rib size of 25 µm in width and an aspect ratio of 1:12 for the master benchmark.
- 15 January 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (1) , 80
Open AccessFeatures of Vat-Photopolymerized Masters for Microfluidic Device Manufacturing
The growing interest in advancing microfluidic devices for manipulating fluids within micrometer-scale channels has prompted a shift in manufacturing practices, moving from single-component production to medium-size batches. This transition arises due to the impracticality of lab-scale manufacturing methods in accommodating the increased demand. This experimental study focuses on the design of master benchmarks 1–5, taking into consideration critical parameters such as rib width, height, and the relative width-to-height ratio. Notably, benchmarks 4 and 5 featured ribs that were strategically connected to the inlet, outlet, and reaction chamber of the master, enhancing their utility for subsequent replica production. Vat photopolymerization was employed for the fabrication of benchmarks 1–5, while replicas of benchmarks 4 and 5 were generated through polydimethylsiloxane casting. Dimensional investigations of the ribs and channels in both the master benchmarks and replicas were conducted using an optical technique validated through readability analysis based on the Michelson global contrast index. The primary goal was to evaluate the potential applicability of vat photopolymerization technology for efficiently producing microfluidic devices through a streamlined production process. Results indicate that the combination of vat photopolymerization followed by replication is well suited for achieving a minimum rib size of 25 µm in width and an aspect ratio of 1:12 for the master benchmark.
- 31 October 2023
- Published by Springer Nature
- p. 699-707
Dimensional and Mechanical Assessment of Gyroid Lattices Produced in Aluminum by Laser Powder Bed Fusion
- 31 October 2023
- Published by Springer Nature
- p. 699-707
Dimensional and Mechanical Assessment of Gyroid Lattices Produced in Aluminum by Laser Powder Bed Fusion
- Open Access
- 22 September 2023
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 14 (10) , 489
On the Biomechanical Performances of Duplex Stainless Steel Graded Scaffolds Produced by Laser Powder Bed Fusion for Tissue Engineering Applications
This experimental study aims to extend the know-how on biomechanical performances of duplex stainless steel (DSS) for tissue engineering applications to a graded lattice geometry scaffold based on the F53 DSS (UNS S32750 according to ASTM A182) produced by laser powder bed fusion (LPBF). The same dense-out graded geometry based on rhombic dodecahedral elementary unit cells investigated in previous work on 316L stainless steel (SS) was adopted here for the manufacturing of the F53 DSS scaffold (SF53). Microstructural characterization and mechanical and biological tests were carried out on the SF53 scaffold, using the in vitro behavior of the 316L stainless steel scaffold (S316L) as a control. Results show that microstructure developed as a consequence of different volume energy density (VED) values is mainly responsible for the different mechanical behaviors of SF53 and S316L, both fabricated using the same LPBF manufacturing system. Specifically, the ultimate compressive strength (σUC) and elastic moduli (E) of SF53 are three times and seven times higher than S316L, respectively. Moreover, preliminary biological tests evidenced better cell viability in SF53 than in S316L already after seven days of culture, suggesting SF53 with dense-out graded geometry as a viable alternative to 316L SS for bone tissue engineering applications.
- 22 September 2023
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 14 (10) , 489
Open AccessOn the Biomechanical Performances of Duplex Stainless Steel Graded Scaffolds Produced by Laser Powder Bed Fusion for Tissue Engineering Applications
This experimental study aims to extend the know-how on biomechanical performances of duplex stainless steel (DSS) for tissue engineering applications to a graded lattice geometry scaffold based on the F53 DSS (UNS S32750 according to ASTM A182) produced by laser powder bed fusion (LPBF). The same dense-out graded geometry based on rhombic dodecahedral elementary unit cells investigated in previous work on 316L stainless steel (SS) was adopted here for the manufacturing of the F53 DSS scaffold (SF53). Microstructural characterization and mechanical and biological tests were carried out on the SF53 scaffold, using the in vitro behavior of the 316L stainless steel scaffold (S316L) as a control. Results show that microstructure developed as a consequence of different volume energy density (VED) values is mainly responsible for the different mechanical behaviors of SF53 and S316L, both fabricated using the same LPBF manufacturing system. Specifically, the ultimate compressive strength (σUC) and elastic moduli (E) of SF53 are three times and seven times higher than S316L, respectively. Moreover, preliminary biological tests evidenced better cell viability in SF53 than in S316L already after seven days of culture, suggesting SF53 with dense-out graded geometry as a viable alternative to 316L SS for bone tissue engineering applications.
- Open Access
- 24 June 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 144, 105989
Improved biomechanical behavior of 316L graded scaffolds for bone tissue regeneration produced by laser powder bed fusion
- 24 June 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 144, 105989
Open AccessImproved biomechanical behavior of 316L graded scaffolds for bone tissue regeneration produced by laser powder bed fusion
- Open Access
Influence of Trabecular Geometry on Scaffold Mechanical Behavior and MG-63 Cell Viability
In a scaffold-based approach for bone tissue regeneration, the control over morphometry allows for balancing scaffold biomechanical performances. In this experimental work, trabecular geometry was obtained by a generative design process, and scaffolds were manufactured by vat photopolymerization with 60% (P60), 70% (P70) and 80% (P80) total porosity. The mechanical and biological performances of the produced scaffolds were investigated, and the results were correlated with morphometric parameters, aiming to investigate the influence of trabecular geometry on the elastic modulus, the ultimate compressive strength of scaffolds and MG-63 human osteosarcoma cell viability. The results showed that P60 trabecular geometry allows for matching the mechanical requirements of human mandibular trabecular bone. From the statistical analysis, a general trend can be inferred, suggesting strut thickness, the degree of anisotropy, connectivity density and specific surface as the main morphometric parameters influencing the biomechanical behavior of trabecular scaffolds, in the perspective of tissue engineering applications.
Open AccessInfluence of Trabecular Geometry on Scaffold Mechanical Behavior and MG-63 Cell Viability
In a scaffold-based approach for bone tissue regeneration, the control over morphometry allows for balancing scaffold biomechanical performances. In this experimental work, trabecular geometry was obtained by a generative design process, and scaffolds were manufactured by vat photopolymerization with 60% (P60), 70% (P70) and 80% (P80) total porosity. The mechanical and biological performances of the produced scaffolds were investigated, and the results were correlated with morphometric parameters, aiming to investigate the influence of trabecular geometry on the elastic modulus, the ultimate compressive strength of scaffolds and MG-63 human osteosarcoma cell viability. The results showed that P60 trabecular geometry allows for matching the mechanical requirements of human mandibular trabecular bone. From the statistical analysis, a general trend can be inferred, suggesting strut thickness, the degree of anisotropy, connectivity density and specific surface as the main morphometric parameters influencing the biomechanical behavior of trabecular scaffolds, in the perspective of tissue engineering applications.
- Open Access
- 23 January 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (2) , 150
Beads for Cell Immobilization: Comparison of Alternative Additive Manufacturing Techniques
The attachment or entrapment of microbial cells and enzymes are promising solutions for various industrial applications. When the traps are beads, they are dispersed in a fluidized bed in a vessel where a pump guarantees fresh liquid inflow and waste outflow without washing out the cells. Scientific papers report numerous types of cell entrapment, but most of their applications remain at the laboratory level. In the present research, rigid polymer beads were manufactured by two different additive manufacturing (AM) techniques in order to verify the economy, reusability, and stability of the traps, with a view toward a straightforward industrial application. The proposed solutions allowed for overcoming some of the drawbacks of traditional manufacturing solutions, such as the limited mechanical stability of gel traps, and they guaranteed the possibility of producing parts of constant quality with purposely designed exchange surfaces, which are unfeasible when using conventional processes. AM proved to be a viable manufacturing solution for beads with complex shapes of two different size ranges. A deep insight into the production and characteristics of beads manufactured by AM is provided. The paper provides biotechnologists with a manufacturing perspective, and the results can be directly applied to transit from the laboratory to the industrial scale.
- 23 January 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (2) , 150
Open AccessBeads for Cell Immobilization: Comparison of Alternative Additive Manufacturing Techniques
The attachment or entrapment of microbial cells and enzymes are promising solutions for various industrial applications. When the traps are beads, they are dispersed in a fluidized bed in a vessel where a pump guarantees fresh liquid inflow and waste outflow without washing out the cells. Scientific papers report numerous types of cell entrapment, but most of their applications remain at the laboratory level. In the present research, rigid polymer beads were manufactured by two different additive manufacturing (AM) techniques in order to verify the economy, reusability, and stability of the traps, with a view toward a straightforward industrial application. The proposed solutions allowed for overcoming some of the drawbacks of traditional manufacturing solutions, such as the limited mechanical stability of gel traps, and they guaranteed the possibility of producing parts of constant quality with purposely designed exchange surfaces, which are unfeasible when using conventional processes. AM proved to be a viable manufacturing solution for beads with complex shapes of two different size ranges. A deep insight into the production and characteristics of beads manufactured by AM is provided. The paper provides biotechnologists with a manufacturing perspective, and the results can be directly applied to transit from the laboratory to the industrial scale.
- Open Access
- 30 September 2022
- Published by MDPI AG in Journal of Manufacturing and Materials Processing
- Vol. 6 (5) , 112
Boosting Productivity of Laser Powder Bed Fusion for AlSi10Mg
The Laser Powder Bed Fusion (L-PBF) process is recognized for high-end industrial applications due to its ability to produce parts with high geometric complexity. If lightweighting is one of the main strengths of L-PBF, a weakness is still the trade-off between high mechanical properties and competitive productivity. This objective can be targeted through a fine tuning of the process parameters within the manufacturing window. The paper pursues the combined optimization of part quality and process productivity for AlSi10Mg by going beyond the commonly used approach based solely on volumetric energy density. The effects of hatch distance and scan speed on the two targets were analyzed in detail. The best results were achieved by the adoption of a high scan speed and a low hatch distance, with notably different outcomes for nearly the same energy density.
- 30 September 2022
- Published by MDPI AG in Journal of Manufacturing and Materials Processing
- Vol. 6 (5) , 112
Open AccessBoosting Productivity of Laser Powder Bed Fusion for AlSi10Mg
The Laser Powder Bed Fusion (L-PBF) process is recognized for high-end industrial applications due to its ability to produce parts with high geometric complexity. If lightweighting is one of the main strengths of L-PBF, a weakness is still the trade-off between high mechanical properties and competitive productivity. This objective can be targeted through a fine tuning of the process parameters within the manufacturing window. The paper pursues the combined optimization of part quality and process productivity for AlSi10Mg by going beyond the commonly used approach based solely on volumetric energy density. The effects of hatch distance and scan speed on the two targets were analyzed in detail. The best results were achieved by the adoption of a high scan speed and a low hatch distance, with notably different outcomes for nearly the same energy density.