Iván Sala-Mira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Iván Sala-Mira has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- José-Luis Díez
Instituto Universitario de Automática e Informática Industrial Universitat Politècnica de València Valencia Spain
8 shared publications - Jorge Bondia
Instituto Universitario de Automática e Informática Industrial Universitat Politècnica de València Valencia Spain
7 shared publications - Clara Furió-Novejarque
Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, Valencia, Spain
4 shared publications - Pedro García
Universitat Politècnica de València
3 shared publications Jorge Bondia
2 shared publications- Alejandro H. Gonzalez
Instituto de Desarrollo Tecnolgico para la Industria Qumica (INTEC), Universidad Nacional del Litoral, CONICET,Santa Fe,Argentina
1 shared publication
Latest Publications
- Open Access
- 24 October 2026
- Published by Elsevier in Control Engineering Practice
- Vol. 178
Control-oriented modeling of glucose insulin dynamics with dynamic insulin sensitivity
- 24 October 2026
- Published by Elsevier in Control Engineering Practice
- Vol. 178
Open AccessControl-oriented modeling of glucose insulin dynamics with dynamic insulin sensitivity
- Open Access
- 12 June 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 194, 110447
In silico evaluation of pramlintide dosing algorithms in artificial pancreas systems
- 12 June 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 194, 110447
Open AccessIn silico evaluation of pramlintide dosing algorithms in artificial pancreas systems
- Open Access
- 24 August 2024
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 44 (3) , 560-568
In silico validation of a customizable fully-autonomous artificial pancreas with coordinated insulin, glucagon and rescue carbohydrates
- 24 August 2024
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 44 (3) , 560-568
Open AccessIn silico validation of a customizable fully-autonomous artificial pancreas with coordinated insulin, glucagon and rescue carbohydrates
- 5 December 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 244, 107968
A model of subcutaneous pramlintide pharmacokinetics and its effect on gastric emptying: Proof-of-concept based on populational data
- 5 December 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 244, 107968
A model of subcutaneous pramlintide pharmacokinetics and its effect on gastric emptying: Proof-of-concept based on populational data
- 8 August 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 226, 107061
Internal model control based module for the elimination of meal and exercise announcements in hybrid artificial pancreas systems
- 8 August 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 226, 107061
Internal model control based module for the elimination of meal and exercise announcements in hybrid artificial pancreas systems
- 7 March 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 219, 106736
Super–twisting-based meal detector for type 1 diabetes management: Improvement and assessment in a real-life scenario
- 7 March 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 219, 106736
Super–twisting-based meal detector for type 1 diabetes management: Improvement and assessment in a real-life scenario
- Open Access
- 15 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 143549-143563
Effect of Model, Observer and Their Interaction on State and Disturbance Estimation in Artificial Pancreas: An In-Silico Study
The state and disturbance estimations are an indispensable part of the state-of-the-art model-based controllers as related to the artificial pancreas, supporting the decision-making and self-tuning of the algorithms. They are not just important when state-feedback kind of controller structure is applied, but also play a crucial role in the estimation of, for example, the amount of the acting drug (insulin) in blood or meal intake estimation which has determining role in the short and long term effectivity of the given therapy. This information is also important for physicians to support them in knowledge-based decision-making to be sure a given therapy or device works well. This article compares three observers – a linear-parameter-varying (LPV) dual Kalman filter (KF), a LPV joint KF, and a nonlinear sliding mode observer (NSMO) – designed with two individualized models – Hovorka and Identifiable Virtual Patient model (IVP). The article also statistically quantifies the effect of the observer algorithm and model structure on the accuracy of the estimation of plasma insulin, rate of glucose appearance, and glucose. Data for the analysis was generated by the UVa-Padova simulator. Results indicated that, for the rate of glucose appearance and the plasma insulin, the type of model and the observer structure explain less than 10% of the variability in the error, while the inter-patient variability contributes to the error more than 50%. This reveals a limiting factor in the estimation accuracy that might be improved by model parameter adaptation.
- 15 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 143549-143563
Open AccessEffect of Model, Observer and Their Interaction on State and Disturbance Estimation in Artificial Pancreas: An In-Silico Study
The state and disturbance estimations are an indispensable part of the state-of-the-art model-based controllers as related to the artificial pancreas, supporting the decision-making and self-tuning of the algorithms. They are not just important when state-feedback kind of controller structure is applied, but also play a crucial role in the estimation of, for example, the amount of the acting drug (insulin) in blood or meal intake estimation which has determining role in the short and long term effectivity of the given therapy. This information is also important for physicians to support them in knowledge-based decision-making to be sure a given therapy or device works well. This article compares three observers – a linear-parameter-varying (LPV) dual Kalman filter (KF), a LPV joint KF, and a nonlinear sliding mode observer (NSMO) – designed with two individualized models – Hovorka and Identifiable Virtual Patient model (IVP). The article also statistically quantifies the effect of the observer algorithm and model structure on the accuracy of the estimation of plasma insulin, rate of glucose appearance, and glucose. Data for the analysis was generated by the UVa-Padova simulator. Results indicated that, for the rate of glucose appearance and the plasma insulin, the type of model and the observer structure explain less than 10% of the variability in the error, while the inter-patient variability contributes to the error more than 50%. This reveals a limiting factor in the estimation accuracy that might be improved by model parameter adaptation.
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 16227-16232
Kalman filter and sliding mode observer in artificial pancreas: an in-silico comparison
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 16227-16232
Kalman filter and sliding mode observer in artificial pancreas: an in-silico comparison
- 1 June 2019
- Published by Elsevier in Journal of Process Control
- Vol. 78, 68-77
Sliding-mode disturbance observers for an artificial pancreas without meal announcement
- 1 June 2019
- Published by Elsevier in Journal of Process Control
- Vol. 78, 68-77
Sliding-mode disturbance observers for an artificial pancreas without meal announcement
- 1 July 2017
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 50 (1) , 7743-7748
Insulin limitation in the Artificial Pancreas by Sliding Mode Reference Conditioning and Insulin Feedback: an in silico comparison
- 1 July 2017
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 50 (1) , 7743-7748
Insulin limitation in the Artificial Pancreas by Sliding Mode Reference Conditioning and Insulin Feedback: an in silico comparison