SMSarah Murseli

Sarah Murseli

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sarah Murseli has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Carley A. Crann

    University of Ottawa - A.E. Lalonde AMS Laboratory

    1 shared publication
  • Christabel Jean

    Department of Earth and Environmental Sciences, and the A.E. Lalonde AMS Laboratory, University of Ottawa, 25 Templeton St, Ottawa, ON, K1N 6N5, Canada

    1 shared publication
  • Gilles St-Jean

    Department of Earth and Environmental Sciences, and the A.E. Lalonde AMS Laboratory, University of Ottawa, 25 Templeton St, Ottawa, ON, K1N 6N5, Canada

    1 shared publication
  • Ian D Clark

    Department of Earth and Environmental Sciences, and the A.E. Lalonde AMS Laboratory, University of Ottawa, 25 Templeton St, Ottawa, ON, K1N 6N5, Canada

    1 shared publication
  • Paul Middlestead

    Department of Earth and Environmental Sciences, and the G.G. Hatch Stable Isotope Laboratory, University of Ottawa, 25 Templeton St, Ottawa, ON, K1N 6N5, Canada

    1 shared publication
  • William E Kieser

    Department of Physics, and the A.E. Lalonde AMS Laboratory, University of Ottawa, 25 Templeton Ave, Ottawa, ON, Canada

    1 shared publication

Latest Publications

  • The Preparation of Water (DIC, DOC) and Gas (CO2, CH4) Samples for Radiocarbon Analysis at AEL-AMS, Ottawa, Canada

    by Sarah Murseli, Paul Middlestead, Gilles St-Jean, Xiaolei Zhao, Christabel Jean, Carley A Crann, William E Kieser, Ian D Clark

    Sample preparation techniques for radiocarbon analysis of dissolved inorganic carbon (DIC) and dissolved organic carbon (DOC) in freshwater, as well as CO2 and CH4 in gas mixtures are presented. Focused efforts have been on developing a robust and low-background wet oxidation extraction method for DOC in freshwater, following routine methods developed for stable carbon isotope analysis and adapted for radiocarbon (14C) analysis. DIC (by acidification) and DOC (by wet oxidation) are converted to CO2 in pre-baked septum-fitted borosilicate bottles, where the resulting CO2 is extracted from the dissolved and headspace portions on a low-flow He-carrier flow-through system interfaced to a vacuum extraction line. A peripheral CH4 extraction line interfaces to the flow line to separate CH4 from environmental samples following the methods of Pack et al. 2015. High sample throughput and low blanks are achievable with this method. DIC and DOC blanks are consistently 2 and CH4 blanks are typically <0.1 pMC.