N. S. Vorobiev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
N. S. Vorobiev has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
A. I. Zarovskii
Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow, Russia
3 shared publicationsA. V. Smirnov
Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow, Russia
3 shared publications- A. E. Zubko
Prokhorov General Physics Institute of the Russian Academy of Sciences
2 shared publications - Alexander Alexandrovitch Samokhin
Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow, Russia
2 shared publications E. V. Shashkov
Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow, Russia
2 shared publications- Evgeny V. Shashkov
Research Center for Laser Materials and Technologies, Prokhorov General Physics Institute of the Russian Academy of Sciences, Vavilova 38, 119991 Moscow, Russia
2 shared publications
Latest Publications
- 1 April 2025
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 68 (2) , 300-304
A Modified Time-Analyzing PIF-01 Electron-Image Tube
One of the possible modifications of a time-analyzing PIF-01 electron-image tube is described. It is shown how, without changing the dimensions of the device and the requirements for its electronics, it is possible to improve the time resolution of the converter. Mathematical modeling of the main technical parameters of the modified electron-image tube is performed, and the experimental results confirming the performed calculations are presented.
- 1 April 2025
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 68 (2) , 300-304
A Modified Time-Analyzing PIF-01 Electron-Image Tube
One of the possible modifications of a time-analyzing PIF-01 electron-image tube is described. It is shown how, without changing the dimensions of the device and the requirements for its electronics, it is possible to improve the time resolution of the converter. Mathematical modeling of the main technical parameters of the modified electron-image tube is performed, and the experimental results confirming the performed calculations are presented.
- 1 April 2023
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 66 (2) , 279-284
Focus Distortion in an Image-Converter Camera at High Scanning Speeds
Measurements of the temporal and spatial resolution of a PS-1/S1 image-converter camera, depending on the scanning speed, were performed. The camera has a PIF-01 electron-optical converter with deflecting plates of the capacitor-type scan. It is shown that obtaining the minimum half-width of the space–time response function in two mutually perpendicular directions (time and space) can be achieved by selecting an optimal voltage at the focusing electrode. The difference between the optimal static and dynamic voltages of focusing in space and time was determined experimentally, which was 450 V for a scanning speed of 1.56 × 1010 cm/s. Computer modeling of the processes that affect the optimal resolution was performed.
- 1 April 2023
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 66 (2) , 279-284
Focus Distortion in an Image-Converter Camera at High Scanning Speeds
Measurements of the temporal and spatial resolution of a PS-1/S1 image-converter camera, depending on the scanning speed, were performed. The camera has a PIF-01 electron-optical converter with deflecting plates of the capacitor-type scan. It is shown that obtaining the minimum half-width of the space–time response function in two mutually perpendicular directions (time and space) can be achieved by selecting an optimal voltage at the focusing electrode. The difference between the optimal static and dynamic voltages of focusing in space and time was determined experimentally, which was 450 V for a scanning speed of 1.56 × 1010 cm/s. Computer modeling of the processes that affect the optimal resolution was performed.
- 1 March 2021
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 64 (2) , 264-269
A Medium-Range-Energy X-Ray Source Based on an Image Converter Tube
A point source of X-ray radiation with an energy range of up to 40 keV has been developed on the basis of a specially designed image converter tube. The source is capable of operating in pulsed and continuous modes. The main purpose of this is to use the source for testing X-ray streak cameras. The device can also be used in X-ray microscopy and spectroscopy as a reference radiation source, in biomedical research, and in other fields.
- 1 March 2021
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 64 (2) , 264-269
A Medium-Range-Energy X-Ray Source Based on an Image Converter Tube
A point source of X-ray radiation with an energy range of up to 40 keV has been developed on the basis of a specially designed image converter tube. The source is capable of operating in pulsed and continuous modes. The main purpose of this is to use the source for testing X-ray streak cameras. The device can also be used in X-ray microscopy and spectroscopy as a reference radiation source, in biomedical research, and in other fields.
- 1 January 2021
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 64 (1) , 161-164
Measuring the Delay Time of Starting a Streak Camera
A method for measuring the response time (dead time) of a streak camera (SC) for several sweep durations is presented. As a rule, the response time of an SC is measured only for the shortest sweep, which makes it difficult to synchronize the trigger pulse of an SC with a studied process when working on other sweeps. The use of a laser diode with a front of at most 1 ns as a light-pulse marker significantly reduced the uncertainty of the moment when the pulse appears on the camera. In addition, the proposed method allows one to take all possible response delays into account, thus increasing the accuracy of the measurements, as well as to measure the duration of SC sweeps.
- 1 January 2021
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 64 (1) , 161-164
Measuring the Delay Time of Starting a Streak Camera
A method for measuring the response time (dead time) of a streak camera (SC) for several sweep durations is presented. As a rule, the response time of an SC is measured only for the shortest sweep, which makes it difficult to synchronize the trigger pulse of an SC with a studied process when working on other sweeps. The use of a laser diode with a front of at most 1 ns as a light-pulse marker significantly reduced the uncertainty of the moment when the pulse appears on the camera. In addition, the proposed method allows one to take all possible response delays into account, thus increasing the accuracy of the measurements, as well as to measure the duration of SC sweeps.
- 15 June 2020
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 63 (3) , 367-369
An Image Converter Camera for Studying Processes in the Nano- and Microsecond Ranges
A chronographic image converter camera has been designed on the basis of a PIF-01 image converter tube to obtain spatial and temporal information in a study of light processes in the nano- and microsecond ranges. The duration of scans on a 25-mm-diameter screen of the camera can be varied from 0.5 to 10 µs with a limiting time resolution of 2 ns or better. Possible applications of the developed camera for spectral and time measurements of processes in real experiments on the study of electric explosion of tungsten wires are described.
- 15 June 2020
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 63 (3) , 367-369
An Image Converter Camera for Studying Processes in the Nano- and Microsecond Ranges
A chronographic image converter camera has been designed on the basis of a PIF-01 image converter tube to obtain spatial and temporal information in a study of light processes in the nano- and microsecond ranges. The duration of scans on a 25-mm-diameter screen of the camera can be varied from 0.5 to 10 µs with a limiting time resolution of 2 ns or better. Possible applications of the developed camera for spectral and time measurements of processes in real experiments on the study of electric explosion of tungsten wires are described.
- 1 January 2020
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 63 (1) , 87-91
A Picosecond Image-Converter Dissector with a Crossed Sweep
A dual-slit dissector operating in the crossed-sweep mode with a picosecond time resolution has been created on the basis of the PIF-01 image converter tube. The dissector is applicable to synchrotron radiation sources and electron-positron colliders when it is necessary to simultaneously record longitudinal profiles of multi-bunch beams that fill two to several hundred adjacent separatrices of an accelerator ring. Two trains of light pulses shifted in time with respect to each other have been recorded with a time resolution of 6.0 ± 0.5 ps during the dynamic tests of the developed dissector with a laser system.
- 1 January 2020
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 63 (1) , 87-91
A Picosecond Image-Converter Dissector with a Crossed Sweep
A dual-slit dissector operating in the crossed-sweep mode with a picosecond time resolution has been created on the basis of the PIF-01 image converter tube. The dissector is applicable to synchrotron radiation sources and electron-positron colliders when it is necessary to simultaneously record longitudinal profiles of multi-bunch beams that fill two to several hundred adjacent separatrices of an accelerator ring. Two trains of light pulses shifted in time with respect to each other have been recorded with a time resolution of 6.0 ± 0.5 ps during the dynamic tests of the developed dissector with a laser system.
- 1 October 2019
- Published by Allerton Press in Physics of Wave Phenomena
- Vol. 27 (4) , 268-270
Nanosecond Calibration of a Piezo Transducer by Comparing Thermoacoustic and Vaporization Pressure Signals at Pulsed Laser Irradiation of a Metal Target
A possibility of calibrating a piezo transducer by comparing thermoacoustic and vaporization pressure signals generated in a metal (liquid mercury) irradiated with nanosecond laser pulses is...
- 1 October 2019
- Published by Allerton Press in Physics of Wave Phenomena
- Vol. 27 (4) , 268-270
Nanosecond Calibration of a Piezo Transducer by Comparing Thermoacoustic and Vaporization Pressure Signals at Pulsed Laser Irradiation of a Metal Target
A possibility of calibrating a piezo transducer by comparing thermoacoustic and vaporization pressure signals generated in a metal (liquid mercury) irradiated with nanosecond laser pulses is...
- 1 January 2019
- Published by Allerton Press in Physics of Wave Phenomena
- Vol. 27 (1) , 42-50
Acoustic Detection of Submicron Depth of Ablation Crater Formed on the Metal Surface under Nanosecond Laser Irradiation
The recently published experimental data on the acoustic monitoring of the impact of a train of picosecond laser pulses with a total duration of about 500 ns and energy density up to 2 J cm−2on a...
- 1 January 2019
- Published by Allerton Press in Physics of Wave Phenomena
- Vol. 27 (1) , 42-50
Acoustic Detection of Submicron Depth of Ablation Crater Formed on the Metal Surface under Nanosecond Laser Irradiation
The recently published experimental data on the acoustic monitoring of the impact of a train of picosecond laser pulses with a total duration of about 500 ns and energy density up to 2 J cm−2on a...
- 26 November 2018
- Published by IOP Publishing in Quantum Electronics
- Vol. 48 (11) , 1067-1072
Method for measuring main characteristics of electron-optical cameras
- 26 November 2018
- Published by IOP Publishing in Quantum Electronics
- Vol. 48 (11) , 1067-1072
Method for measuring main characteristics of electron-optical cameras