Kaddour Bouazza-Marouf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kaddour Bouazza-Marouf has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- David Kerr
Loughborough Univ. of Technology (United Kingdom)
2 shared publications - Sijung Hu
Carelight Ltd. UK (United Kingdom)
2 shared publications - Yasmin Elsahar
Wolfson School of Mechanical, Electrical, and Manufacturing Engineering, Loughborough University, Leicestershire, UK
2 shared publications Alan P Slade
University of Dundee
1 shared publication- Alexander Laurence Green
University of Oxford
1 shared publication Amr M M A Mohsen
Royal Hull Hospitals
1 shared publication
Latest Publications
- Open Access
- 8 February 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (2) , 025011
Analysis of the validity of the mathematical assumptions of electrical impedance tomography for human head tissues
Objective: To determine the validity of the key mathematical assumptions used in electrical impedance tomography for human head tissues. Approach:Conductivity and permittivity data collected from available literature for each tissue within the human head have been evaluated and critiqued. The most relevant dielectric tissue data for each tissue was then used to assess the validity of the mathematical assumptions of electrical impedance tomography in terms of their suitability for human head imaging in order to estimate related errors. Main Results:For induced currents with frequencies greater than 200 Hz the internal current source density is negligible. The assumption that magnetic effects are negligible is valid to an error of 1.7% for human head tissues for frequencies below 1 MHz. The capacitive effects are negligible for CSF, dura mater, blood, bone (cortical), and deep tissue skin for frequencies less than 3.2 MHz, 320 kHz, 25 kHz, 3.2 kHz, and 130 Hz respectively. However, the capacitive effects are not negligible for brain tissues, as the minimum error for brain tissues across the frequency range of 10 Hz to 100 GHz is 6.2% at 800 Hz, and the maximum error is 410% at 20 GHz. Significance:It is often assumed that the mathematical reduction of the base equations is valid for human head tissues over a broad frequency range; this study shows that these assumptions are not true for all tissues at all frequencies. False assumptions will result in greater errors and local distortions within tomographic images of the human head using electrical impedance tomography. This study provides the relationships between injected current frequency and the validity of the mathematical assumptions for each individual tissue, providing greater awareness of the magnitude of possible distortions.
- 8 February 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (2) , 025011
Open AccessAnalysis of the validity of the mathematical assumptions of electrical impedance tomography for human head tissues
Objective: To determine the validity of the key mathematical assumptions used in electrical impedance tomography for human head tissues. Approach:Conductivity and permittivity data collected from available literature for each tissue within the human head have been evaluated and critiqued. The most relevant dielectric tissue data for each tissue was then used to assess the validity of the mathematical assumptions of electrical impedance tomography in terms of their suitability for human head imaging in order to estimate related errors. Main Results:For induced currents with frequencies greater than 200 Hz the internal current source density is negligible. The assumption that magnetic effects are negligible is valid to an error of 1.7% for human head tissues for frequencies below 1 MHz. The capacitive effects are negligible for CSF, dura mater, blood, bone (cortical), and deep tissue skin for frequencies less than 3.2 MHz, 320 kHz, 25 kHz, 3.2 kHz, and 130 Hz respectively. However, the capacitive effects are not negligible for brain tissues, as the minimum error for brain tissues across the frequency range of 10 Hz to 100 GHz is 6.2% at 800 Hz, and the maximum error is 410% at 20 GHz. Significance:It is often assumed that the mathematical reduction of the base equations is valid for human head tissues over a broad frequency range; this study shows that these assumptions are not true for all tissues at all frequencies. False assumptions will result in greater errors and local distortions within tomographic images of the human head using electrical impedance tomography. This study provides the relationships between injected current frequency and the validity of the mathematical assumptions for each individual tissue, providing greater awareness of the magnitude of possible distortions.
- Top Cited PapersOpen Access
Augmentative and Alternative Communication (AAC) Advances: A Review of Configurations for Individuals with a Speech Disability
High-tech augmentative and alternative communication (AAC) methods are on a constant rise; however, the interaction between the user and the assistive technology is still challenged for an optimal user experience centered around the desired activity. This review presents a range of signal sensing and acquisition methods utilized in conjunction with the existing high-tech AAC platforms for individuals with a speech disability, including imaging methods, touch-enabled systems, mechanical and electro-mechanical access, breath-activated methods, and brain–computer interfaces (BCI). The listed AAC sensing modalities are compared in terms of ease of access, affordability, complexity, portability, and typical conversational speeds. A revelation of the associated AAC signal processing, encoding, and retrieval highlights the roles of machine learning (ML) and deep learning (DL) in the development of intelligent AAC solutions. The demands and the affordability of most systems hinder the scale of usage of high-tech AAC. Further research is indeed needed for the development of intelligent AAC applications reducing the associated costs and enhancing the portability of the solutions for a real user’s environment. The consolidation of natural language processing with current solutions also needs to be further explored for the amelioration of the conversational speeds. The recommendations for prospective advances in coming high-tech AAC are addressed in terms of developments to support mobile health communicative applications.
Top Cited PapersOpen AccessAugmentative and Alternative Communication (AAC) Advances: A Review of Configurations for Individuals with a Speech Disability
High-tech augmentative and alternative communication (AAC) methods are on a constant rise; however, the interaction between the user and the assistive technology is still challenged for an optimal user experience centered around the desired activity. This review presents a range of signal sensing and acquisition methods utilized in conjunction with the existing high-tech AAC platforms for individuals with a speech disability, including imaging methods, touch-enabled systems, mechanical and electro-mechanical access, breath-activated methods, and brain–computer interfaces (BCI). The listed AAC sensing modalities are compared in terms of ease of access, affordability, complexity, portability, and typical conversational speeds. A revelation of the associated AAC signal processing, encoding, and retrieval highlights the roles of machine learning (ML) and deep learning (DL) in the development of intelligent AAC solutions. The demands and the affordability of most systems hinder the scale of usage of high-tech AAC. Further research is indeed needed for the development of intelligent AAC applications reducing the associated costs and enhancing the portability of the solutions for a real user’s environment. The consolidation of natural language processing with current solutions also needs to be further explored for the amelioration of the conversational speeds. The recommendations for prospective advances in coming high-tech AAC are addressed in terms of developments to support mobile health communicative applications.
- Open Access
- 15 May 2018
- Published by MDPI AG in Biosensors
- Vol. 8 (2) , 48
Breathing Pattern Interpretation as an Alternative and Effective Voice Communication Solution
Augmentative and alternative communication (AAC) systems tend to rely on the interpretation of purposeful gestures for interaction. Existing AAC methods could be cumbersome and limit the solutions in terms of versatility. The study aims to interpret breathing patterns (BPs) to converse with the outside world by means of a unidirectional microphone and researches breathing-pattern interpretation (BPI) to encode messages in an interactive manner with minimal training. We present BP processing work with (1) output synthesized machine-spoken words (SMSW) along with single-channel Weiner filtering (WF) for signal de-noising, and (2) k-nearest neighbor (k-NN) classification of BPs associated with embedded dynamic time warping (DTW). An approved protocol to collect analogue modulated BP sets belonging to 4 distinct classes with 10 training BPs per class and 5 live BPs per class was implemented with 23 healthy subjects. An 86% accuracy of k-NN classification was obtained with decreasing error rates of 17%, 14%, and 11% for the live classifications of classes 2, 3, and 4, respectively. The results express a systematic reliability of 89% with increased familiarity. The outcomes from the current AAC setup recommend a durable engineering solution directly beneficial to the sufferers.
- 15 May 2018
- Published by MDPI AG in Biosensors
- Vol. 8 (2) , 48
Open AccessBreathing Pattern Interpretation as an Alternative and Effective Voice Communication Solution
Augmentative and alternative communication (AAC) systems tend to rely on the interpretation of purposeful gestures for interaction. Existing AAC methods could be cumbersome and limit the solutions in terms of versatility. The study aims to interpret breathing patterns (BPs) to converse with the outside world by means of a unidirectional microphone and researches breathing-pattern interpretation (BPI) to encode messages in an interactive manner with minimal training. We present BP processing work with (1) output synthesized machine-spoken words (SMSW) along with single-channel Weiner filtering (WF) for signal de-noising, and (2) k-nearest neighbor (k-NN) classification of BPs associated with embedded dynamic time warping (DTW). An approved protocol to collect analogue modulated BP sets belonging to 4 distinct classes with 10 training BPs per class and 5 live BPs per class was implemented with 23 healthy subjects. An 86% accuracy of k-NN classification was obtained with decreasing error rates of 17%, 14%, and 11% for the live classifications of classes 2, 3, and 4, respectively. The results express a systematic reliability of 89% with increased familiarity. The outcomes from the current AAC setup recommend a durable engineering solution directly beneficial to the sufferers.
- Open Access
- 1 February 2013
- Published by Institution of Engineering and Technology (IET) in IET Control Theory & Applications
- Vol. 7 (3) , 423-430
Performance estimation of two‐sliding mode controllers for chatter reduction in linear systems
Sliding mode control is a simple and powerful technique for the robust control of uncertain systems. However, despite theoretical promise, real systems using sliding mode controllers have a tendency to chatter at higher frequencies. Second order or two‐sliding mode controllers, can be used to suppress chatter while retaining the desirable properties of a classical sliding mode controller. These more complex controllers increase the number of parameters in the system. The affect of these new parameters on system performance is unclear, and this can make it difficult to tune the controllers to meet a desired performance criteria. This study addresses the problem of estimating the performance of a system controlled by two‐sliding mode controllers. Describing functions are proposed to estimate chattering amplitude and settling time, and a new method is presented, based on invariant ellipsoid sets, to predict the maximum output bound of the system. The aim is assist in producing a systematic approach for practitioners wishing to directly apply sliding mode controllers with chatter suppressing properties to real applications.
- 1 February 2013
- Published by Institution of Engineering and Technology (IET) in IET Control Theory & Applications
- Vol. 7 (3) , 423-430
Open AccessPerformance estimation of two‐sliding mode controllers for chatter reduction in linear systems
Sliding mode control is a simple and powerful technique for the robust control of uncertain systems. However, despite theoretical promise, real systems using sliding mode controllers have a tendency to chatter at higher frequencies. Second order or two‐sliding mode controllers, can be used to suppress chatter while retaining the desirable properties of a classical sliding mode controller. These more complex controllers increase the number of parameters in the system. The affect of these new parameters on system performance is unclear, and this can make it difficult to tune the controllers to meet a desired performance criteria. This study addresses the problem of estimating the performance of a system controlled by two‐sliding mode controllers. Describing functions are proposed to estimate chattering amplitude and settling time, and a new method is presented, based on invariant ellipsoid sets, to predict the maximum output bound of the system. The aim is assist in producing a systematic approach for practitioners wishing to directly apply sliding mode controllers with chatter suppressing properties to real applications.
- 4 January 2008
- Published by Springer Nature
- p. 305-312
Robotic System for Femoral & Tibial Osteotomies Assistance
- 4 January 2008
- Published by Springer Nature
- p. 305-312
Robotic System for Femoral & Tibial Osteotomies Assistance