LMLiuzheng Ma

Liuzheng Ma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Liuzheng Ma has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Multi-Channel Optoelectronic Measurement System for Soil Nutrients Analysis

    by Liuzheng Ma, Zhenfeng Li, Zephania Birech, Shixin Li, Yatao Yang, Wei Zhang, Jiandong Hu

    To solve the problems that occur when farmers overuse chemical fertilizers, it is necessary to develop rapid and efficient portable measurement systems for the detection and quantification of nitrogen (N), phosphorus (P), and potassium (K) in soil. Challenges arise from the use of currently available portable instruments which only have a few channels, namely measurement and the reference channels. We report on a home-built, multichannel, optoelectronic measurement system with automatically switching light sources for the detection of N, P, K content in soil samples. This optoelectronic measurement system consists of joint LED light sources with peak emission wavelengths of 405 nm, 660 nm, and 515 nm, a photodiode array, a circuit board with a microcontroller unit (MCU), and a liquid-crystal display (LCD) touch screen. The straightforward principle for rapid detection of the extractable nutrients (N, P, K) was well-established, and characterization of the designed measurement system was done. Using this multi-channel measurement system, available nutrients extracted from six soil samples could be measured simultaneously. The absorbance compensation, concentration calibration, and nutrition measurements were performed automatically to achieve high consistency across six channels. The experimental results showed that the cumulative relative standard deviations of 1.22%, 1.27%, and 1.00% were obtained from six channels with known concentrations of standard solutions, respectively. The coefficients of correlation for the detection of extracted nutrients of N, P, K content in soil samples using both the proposed method and conventional lab-based method were 0.9010, 0.9471, and 0.8923, respectively. Experimental results show that this optoelectronic measurement system can perform the measurement of N, P, K contents of six soil samples simultaneously and may be used as an actual tool in determining nutrients in soil samples with an improvement in detection efficiency.


  • Open Access

    Classification of Corn Stalk Lodging Resistance Using Equivalent Forces Combined with SVD Algorithm

    by Qingqian Guo, Ruipeng Chen, Liuzheng Ma, Haifeng Sun, Mengmeng Weng, Shixin Li, Jiandong Hu

    Corn stalk lodging, which involves the breakage of the stalk below the ear following either bad weather, insect infestation or stormy rain, usually leads to harvest loss, increased harvesting time and higher drying costs. The objective of this study was to develop a method that can classify corn stalk lodging resistance. This method, which employed the maximum equivalent force exerted on a corn stalk, corresponding stalk agronomic traits, and the singular value decomposition (SVD) algorithm, showed that the five corn varieties with different stalk lodging resistance from two planting densities of 60,000 plants/ha and 75,000 plants/ha can be effectively classified. A customized device was designed to measure the equivalent forces. Three factors, including the planting density, the stalk diameter, and the maximum equivalent force with comprehensive contributions of −0.4603, 0.4196 and 0.4068, which are related to principal components, play an important role in the classification of corn stalk lodging resistance. The results showed that the corn stalk lodging resistance decreased with increase in planting density; however, with the increase in stalk diameter and maximum equivalent force, the lodging resistance significantly increased. Corn breeders can develop higher lodging resistance-based corn varieties by using this approach.


  • Open Access

    A Non-Destructive and Direction-Insensitive Method Using a Strain Sensor and Two Single Axis Angle Sensors for Evaluating Corn Stalk Lodging Resistance

    by Qingqian Guo, Ruipeng Chen, Xiaoquan Sun, Min Jiang, Haifeng Sun, Shun Wang, Liuzheng Ma, Yatao Yang, Jiandong Hu

    Corn stalk lodging is caused by different factors, including severe wind storms, stalk cannibalization, and stalk rots, and it leads to yield loss. Determining how to rapidly evaluate corn lodging resistance will assist scientists in the field of crop breeding to understand the contributing factors in managing the moisture, chemical fertilizer, and weather conditions for corn growing. This study proposes a non-destructive and direction-insensitive method, using a strain sensor and two single axis angle sensors to measure the corn stalk lodging resistance in the field. An equivalent force whose direction is perpendicular to the stalk is utilized to evaluate the corn lodging properties when a pull force is applied on the corn stalk. A novel measurement device is designed to obtain the equivalent force with the coefficient of variation (CV) of 4.85%. Five corn varieties with two different planting densities are arranged to conduct the experiment using the novel measurement device. The experimental results show that the maximum equivalent force could reach up to 44 N. A strong relationship with the square of the correlation coefficient of 0.88 was obtained between the maximum equivalent forces and the corn field’s stalk lodging rates. Moreover, the stalk lodging angles corresponding to the different pull forces over a measurement time of 20 s shift monotonically along the equivalent forces. Thus, the non-destructive and direction-insensitive method is an excellent tool for rapid analysis of stalk lodging resistance in corn, providing critical information on in-situ lodging dynamics.


  • Open Access

    The Development of a Portable SPR Bioanalyzer for Sensitive Detection of Escherichia coli O157:H7

    by Shun Wang, Jiufeng Xie, Min Jiang, Keke Chang, Ruipeng Chen, Liuzheng Ma, Juanhua Zhu, Qingqian Guo, Haifeng Sun, Jiandong Hu

    The purpose of this study was to develop a portable surface plasmon resonance (SPR) bioanalyzer for the sensitive detection of Escherichia coli O157:H7 in comparison with an enzyme-linked immunosorbent assay (ELISA). The experimental setup mainly consisted of an integrated biosensor and a homemade microfluidic cell with a three-way solenoid valve. In order to detect Escherichia coli O157:H7 using the SPR immunoassay, 3-mercaptopropionic acid (3-MPA) was chemisorbed onto a gold surface via covalent bond for the immobilization of biological species. 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) were used as crosslinker reagents to enable the reaction between 3-MPA and Escherichia coli O157:H7 antibodies by covalent –CO–NH– amide bonding. The experimental results were obtained from the Escherichia coli O157:H7 positive samples prepared by 10-, 20-, 40-, 80-, and 160-fold dilution respectively, which show that a good linear relationship with the correlation coefficient R of 0.982 existed between the response units from the portable SPR bioanalyzer and the concentration of Escherichia coli O157:H7 positive samples. Moreover, the theoretical detection limit of 1.87 × 103 cfu/mL was calculated from the positive control samples. Compared with the Escherichia coli O157:H7 ELISA kit, the sensitivity of this portable SPR bioanalyzer is four orders of magnitude higher than the ELISA kit. The results demonstrate that the portable SPR bioanalyzer could provide an alternative method for the quantitative and sensitive determination of Escherichia coli O157:H7 in field.


  • Open Access

    A Low Cost Compact Measurement System Constructed Using a Smart Electrochemical Sensor for the Real-Time Discrimination of Fruit Ripening

    by Liuzheng Ma, Ling Wang, Ruipeng Chen, Keke Chang, Shun Wang, Xinran Hu, Xiaohui Sun, Zhaohui Lu, Haifeng Sun, Qingqian Guo, et al.

    Ethylene as an indicator for evaluating fruit ripening can be measured by very sensitive electrochemical gas sensors based on a high-resolution current produced by a bias potential applied to the electrodes. For this purpose, a measurement system for monitoring ethylene gas concentrations to evaluate fruit ripening by using the electrochemical ethylene sensor was successfully developed. Before the electrochemical ethylene sensor was used to measure the ethylene gas concentrations released from fruits, a calibration curve was established by the standard ethylene gases at concentrations of 2.99 ppm, 4.99 ppm, 8.01 ppm and 10 ppm, respectively, with a flow rate of 0.4 L·min−1. From the calibration curve, the linear relationship between the responses and concentrations of ethylene gas was obtained in the range of 0–10 ppm with the correlation coefficient R2 of 0.9976. The micropump and a novel signal conditioning circuit were implemented in this measurement, resulting in a rapid response in detecting ethylene concentrations down to 0.1 ppm in air and in under 50 s. In this experiment, three kinds of fruits—apples, pears and kiwifruits—were studied at a low concentration (under 0.8 ppm) of trace ethylene content in the air exhaled by fruits. The experimental results showed that a low cost, compact measurement system constructed by using an electrochemical ethylene sensor has a high sensitivity of 0.3907 V·ppm−1 with a theoretical detection limit of 0.413 ppm, and is non-invasive and highly portable.


  • Open Access

    Considerations on Circuit Design and Data Acquisition of a Portable Surface Plasmon Resonance Biosensing System

    by Keke Chang, Ruipeng Chen, Shun Wang, Jianwei Li, Xinran Hu, Hao Liang, Baiqiong Cao, Xiaohui Sun, Liuzheng Ma, Juanhua Zhu, et al.

    The aim of this study was to develop a circuit for an inexpensive portable biosensing system based on surface plasmon resonance spectroscopy. This portable biosensing system designed for field use is characterized by a special structure which consists of a microfluidic cell incorporating a right angle prism functionalized with a biomolecular identification membrane, a laser line generator and a data acquisition circuit board. The data structure, data memory capacity and a line charge-coupled device (CCD) array with a driving circuit for collecting the photoelectric signals are intensively focused on and the high performance analog-to-digital (A/D) converter is comprehensively evaluated. The interface circuit and the photoelectric signal amplifier circuit are first studied to obtain the weak signals from the line CCD array in this experiment. Quantitative measurements for validating the sensitivity of the biosensing system were implemented using ethanol solutions of various concentrations indicated by volume fractions of 5%, 8%, 15%, 20%, 25%, and 30%, respectively, without a biomembrane immobilized on the surface of the SPR sensor. The experiments demonstrated that it is possible to detect a change in the refractive index of an ethanol solution with a sensitivity of 4.99838 × 105 ΔRU/RI in terms of the changes in delta response unit with refractive index using this SPR biosensing system, whereby the theoretical limit of detection of 3.3537 × 10−5 refractive index unit (RIU) and a high linearity at the correlation coefficient of 0.98065. The results obtained from a series of tests confirmed the practicality of this cost-effective portable SPR biosensing system.