Pascal Alexander Hager
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Pascal Alexander Hager has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Luca Benini
University of Bologna, Bologna, Italy
2 shared publications - Christian Baumgartner
Institute of Health Care Engineering with European Testing Center of Medical Devices, Graz University of Technology, Graz, Austria
1 shared publication - Christian Peham
Movement Science Group, Clinical Centre for Equine Health and Research, Clinical Department for Small Animals and Horses, University of Veterinary Medicine, 1210 Vienna, Austria
1 shared publication - Christoph Leitner
ETH Zurich
1 shared publication - Harald Penasso
Ludwig Boltzmann Institute for Traumatology, 1200 Vienna, Austria
1 shared publication - Markus Tilp
Institute of Human Movement Science, Sports and Health, University of Graz, Graz, Austria
1 shared publication
Latest Publications
- Open Access
Ultrasound as a Tool to Study Muscle–Tendon Functions during Locomotion: A Systematic Review of Applications
Movement science investigating muscle and tendon functions during locomotion utilizes commercial ultrasound imagers built for medical applications. These limit biomechanics research due to their form factor, range of view, and spatio-temporal resolution. This review systematically investigates the technical aspects of applying ultrasound as a research tool to investigate human and animal locomotion. It provides an overview on the ultrasound systems used and of their operating parameters. We present measured fascicle velocities and discuss the results with respect to operating frame rates during recording. Furthermore, we derive why muscle and tendon functions should be recorded with a frame rate of at least 150 Hz and a range of view of 250 mm. Moreover, we analyze why and how the development of better ultrasound observation devices at the hierarchical level of muscles and tendons can support biomechanics research. Additionally, we present recent technological advances and their possible application. We provide a list of recommendations for the development of a more advanced ultrasound sensor system class targeting biomechanical applications. Looking to the future, mobile, ultrafast ultrasound hardware technologies create immense opportunities to expand the existing knowledge of human and animal movement.
Open AccessUltrasound as a Tool to Study Muscle–Tendon Functions during Locomotion: A Systematic Review of Applications
Movement science investigating muscle and tendon functions during locomotion utilizes commercial ultrasound imagers built for medical applications. These limit biomechanics research due to their form factor, range of view, and spatio-temporal resolution. This review systematically investigates the technical aspects of applying ultrasound as a research tool to investigate human and animal locomotion. It provides an overview on the ultrasound systems used and of their operating parameters. We present measured fascicle velocities and discuss the results with respect to operating frame rates during recording. Furthermore, we derive why muscle and tendon functions should be recorded with a frame rate of at least 150 Hz and a range of view of 250 mm. Moreover, we analyze why and how the development of better ultrasound observation devices at the hierarchical level of muscles and tendons can support biomechanics research. Additionally, we present recent technological advances and their possible application. We provide a list of recommendations for the development of a more advanced ultrasound sensor system class targeting biomechanical applications. Looking to the future, mobile, ultrafast ultrasound hardware technologies create immense opportunities to expand the existing knowledge of human and animal movement.
- 7 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 66 (4) , 747-760
LightProbe: A Digital Ultrasound Probe for Software-Defined Ultrafast Imaging
Digital ultrasound probes integrate the analog front end in the housing of the probe handle and provide a digital interface instead of requiring an expensive coaxial cable harness to connect. Current digital probes target the portable market and perform the bulk of the processing (beamforming) on the probe, which enables the probe to be connected to commodity devices, such as tablets or smartphones, running an ultrasound app to display the image and control the probe. Thermal constraints limit the number of front-end channels as well as the complexity of the processing. This prevents current digital probes to support advanced modalities, such as vector flow or elastography, requiring high-frame-rate imaging. In this paper, we present LIGHT-PROBE, a digital ultrasound probe, which integrates a 64-channel 100-Vpp TX/RX front end, including analog-to-digital conversion (up to 32.5 MS/s at 12 bit), and is equipped with an optical high-speed link (26.4 Gb/s) providing sustainable raw samples access to all the channels, which allows the processing to be performed on the connected device without thermal power constraints. By connecting the probe to a graphics processing unit-equipped PC, we demonstrate the flexibility of software-defined B-mode imaging using conventional and ultrafast methods. We achieve plane-wave and synthetic aperture imaging with frame rates from 30 up to 500 Hz consuming between 5.6 and 10.7 W. By using a combination of power and thermal management techniques, we demonstrate that the probe can remain within operating temperature limits even without active cooling, while never having to turn the probe off for cooling, hence providing a consistent quality of service for the operator.
- 7 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 66 (4) , 747-760
LightProbe: A Digital Ultrasound Probe for Software-Defined Ultrafast Imaging
Digital ultrasound probes integrate the analog front end in the housing of the probe handle and provide a digital interface instead of requiring an expensive coaxial cable harness to connect. Current digital probes target the portable market and perform the bulk of the processing (beamforming) on the probe, which enables the probe to be connected to commodity devices, such as tablets or smartphones, running an ultrasound app to display the image and control the probe. Thermal constraints limit the number of front-end channels as well as the complexity of the processing. This prevents current digital probes to support advanced modalities, such as vector flow or elastography, requiring high-frame-rate imaging. In this paper, we present LIGHT-PROBE, a digital ultrasound probe, which integrates a 64-channel 100-Vpp TX/RX front end, including analog-to-digital conversion (up to 32.5 MS/s at 12 bit), and is equipped with an optical high-speed link (26.4 Gb/s) providing sustainable raw samples access to all the channels, which allows the processing to be performed on the connected device without thermal power constraints. By connecting the probe to a graphics processing unit-equipped PC, we demonstrate the flexibility of software-defined B-mode imaging using conventional and ultrafast methods. We achieve plane-wave and synthetic aperture imaging with frame rates from 30 up to 500 Hz consuming between 5.6 and 10.7 W. By using a combination of power and thermal management techniques, we demonstrate that the probe can remain within operating temperature limits even without active cooling, while never having to turn the probe off for cooling, hence providing a consistent quality of service for the operator.