Hong Ji Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hong Ji Lee has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Kwang Suk Park
Department of Biomedical Engineering, College of Medicine, Seoul National University, Seoul, South Korea
4 shared publications - Beomseok Jeon
Department of Neurology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
2 shared publications - Han Byul Kim
The Interdisciplinary Program for Bioengineering, Seoul National University, Seoul 03080, Korea
2 shared publications - Hyeyoung Park
Department of Neurology and Movement Disorder Center, Seoul National University Hospital, Seoul 03080, Korea
2 shared publications - Hyoseon Jeon
The Interdisciplinary Program for Bioengineering, Seoul National University, Seoul 03080, Korea
2 shared publications - Sang Kyong Kim
The Interdisciplinary Program for Bioengineering, Seoul National University, Seoul 03080, Korea
2 shared publications
Latest Publications
- Open Access
Optimal Lead Position in Patch-Type Monitoring Sensors for Reconstructing 12-Lead ECG Signals with Universal Transformation Coefficient
The aim of this study was to reconstruct a 12-lead electrocardiograph (ECG) with a universal transformation coefficient and find the appropriate electrode position and shape for designing a patch-type ECG sensor. A 35-channel ECG monitoring system was developed, and 14 subjects were recruited for the experiment. A feedforward neural network with one hidden layer was applied to train the transformation coefficient. Three electrode shapes (5 cm × 5 cm square, 10 cm × 10 cm square, and right-angled triangle) were considered for the patch-type ECG sensor. The mean correlation coefficient (CC) and minimum CC methods were applied to evaluate the reconstruction performance. The average CCs between the standard 12-lead ECG and reconstructed 12-lead ECG were 0.860, 0.893, and 0.893 for a 5 cm × 5 cm square, 10 cm × 10 cm square, and right-angled triangle shape. The right-angled triangle showed the highest performance among the considered shapes. The results also suggested that the bottom of the central area of the chest was the most suitable position for attaching the patch-type ECG sensor.
Open AccessOptimal Lead Position in Patch-Type Monitoring Sensors for Reconstructing 12-Lead ECG Signals with Universal Transformation Coefficient
The aim of this study was to reconstruct a 12-lead electrocardiograph (ECG) with a universal transformation coefficient and find the appropriate electrode position and shape for designing a patch-type ECG sensor. A 35-channel ECG monitoring system was developed, and 14 subjects were recruited for the experiment. A feedforward neural network with one hidden layer was applied to train the transformation coefficient. Three electrode shapes (5 cm × 5 cm square, 10 cm × 10 cm square, and right-angled triangle) were considered for the patch-type ECG sensor. The mean correlation coefficient (CC) and minimum CC methods were applied to evaluate the reconstruction performance. The average CCs between the standard 12-lead ECG and reconstructed 12-lead ECG were 0.860, 0.893, and 0.893 for a 5 cm × 5 cm square, 10 cm × 10 cm square, and right-angled triangle shape. The right-angled triangle showed the highest performance among the considered shapes. The results also suggested that the bottom of the central area of the chest was the most suitable position for attaching the patch-type ECG sensor.
- Open Access
Automatic Classification of Tremor Severity in Parkinson’s Disease Using a Wearable Device
Although there is clinical demand for new technology that can accurately measure Parkinsonian tremors, automatic scoring of Parkinsonian tremors using machine-learning approaches has not yet been employed. This study aims to fill this gap by proposing machine-learning algorithms as a way to predict the Unified Parkinson’s Disease Rating Scale (UPDRS), which are similar to how neurologists rate scores in actual clinical practice. In this study, the tremor signals of 85 patients with Parkinson’s disease (PD) were measured using a wrist-watch-type wearable device consisting of an accelerometer and a gyroscope. The displacement and angle signals were calculated from the measured acceleration and angular velocity, and the acceleration, angular velocity, displacement, and angle signals were used for analysis. Nineteen features were extracted from each signal, and the pairwise correlation strategy was used to reduce the number of feature dimensions. With the selected features, a decision tree (DT), support vector machine (SVM), discriminant analysis (DA), random forest (RF), and k-nearest-neighbor (kNN) algorithm were explored for automatic scoring of the Parkinsonian tremor severity. The performance of the employed classifiers was analyzed using accuracy, recall, and precision, and compared to other findings in similar studies. Finally, the limitations and plans for further study are discussed.
Open AccessAutomatic Classification of Tremor Severity in Parkinson’s Disease Using a Wearable Device
Although there is clinical demand for new technology that can accurately measure Parkinsonian tremors, automatic scoring of Parkinsonian tremors using machine-learning approaches has not yet been employed. This study aims to fill this gap by proposing machine-learning algorithms as a way to predict the Unified Parkinson’s Disease Rating Scale (UPDRS), which are similar to how neurologists rate scores in actual clinical practice. In this study, the tremor signals of 85 patients with Parkinson’s disease (PD) were measured using a wrist-watch-type wearable device consisting of an accelerometer and a gyroscope. The displacement and angle signals were calculated from the measured acceleration and angular velocity, and the acceleration, angular velocity, displacement, and angle signals were used for analysis. Nineteen features were extracted from each signal, and the pairwise correlation strategy was used to reduce the number of feature dimensions. With the selected features, a decision tree (DT), support vector machine (SVM), discriminant analysis (DA), random forest (RF), and k-nearest-neighbor (kNN) algorithm were explored for automatic scoring of the Parkinsonian tremor severity. The performance of the employed classifiers was analyzed using accuracy, recall, and precision, and compared to other findings in similar studies. Finally, the limitations and plans for further study are discussed.
- 1 March 2016
- Published by Elsevier in Journal of the Neurological Sciences
- Vol. 362, 272-277
Tremor frequency characteristics in Parkinson's disease under resting-state and stress-state conditions
- 1 March 2016
- Published by Elsevier in Journal of the Neurological Sciences
- Vol. 362, 272-277
Tremor frequency characteristics in Parkinson's disease under resting-state and stress-state conditions
- Open Access
Heart Rate Variability Monitoring during Sleep Based on Capacitively Coupled Textile Electrodes on a Bed
In this study, we developed and tested a capacitively coupled electrocardiogram (ECG) measurement system using conductive textiles on a bed, for long-term healthcare monitoring. The system, which was designed to measure ECG in a bed with no constraints of sleep position and posture, included a foam layer to increase the contact region with the curvature of the body and a cover to ensure durability and easy installation. Nine healthy subjects participated in the experiment during polysomnography (PSG), and the heart rate (HR) coverage and heart rate variability (HRV) parameters were analyzed to evaluate the system. The experimental results showed that the mean of R-peak coverage was 98.0% (95.5%–99.7%), and the normalized errors of HRV time and spectral measures between the Ag/AgCl system and our system ranged from 0.15% to 4.20%. The root mean square errors for inter-beat (RR) intervals and HR were 1.36 ms and 0.09 bpm, respectively. We also showed the potential of our developed system for rapid eye movement (REM) sleep and wake detection as well as for recording of abnormal states.
Open AccessHeart Rate Variability Monitoring during Sleep Based on Capacitively Coupled Textile Electrodes on a Bed
In this study, we developed and tested a capacitively coupled electrocardiogram (ECG) measurement system using conductive textiles on a bed, for long-term healthcare monitoring. The system, which was designed to measure ECG in a bed with no constraints of sleep position and posture, included a foam layer to increase the contact region with the curvature of the body and a cover to ensure durability and easy installation. Nine healthy subjects participated in the experiment during polysomnography (PSG), and the heart rate (HR) coverage and heart rate variability (HRV) parameters were analyzed to evaluate the system. The experimental results showed that the mean of R-peak coverage was 98.0% (95.5%–99.7%), and the normalized errors of HRV time and spectral measures between the Ag/AgCl system and our system ranged from 0.15% to 4.20%. The root mean square errors for inter-beat (RR) intervals and HR were 1.36 ms and 0.09 bpm, respectively. We also showed the potential of our developed system for rapid eye movement (REM) sleep and wake detection as well as for recording of abnormal states.