Hee-Yeon Woo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hee-Yeon Woo has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Hyosoon Park
Department of Laboratory Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
12 shared publicationsMin-Jung Kwon
Department of Laboratory Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
5 shared publicationsKiwoong Ko
Department of Laboratory Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea
4 shared publications- Min-Jung Kwon
Department of Laboratory Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
4 shared publications - Shinae Yu
Department of Laboratory Medicine, Inje University Haeundae Paik Hospital, Inje University College of Medicine, Busan, Korea
3 shared publications Eun Hee Lee
Green Cross Reference Laboratory, Yongin, Kyunggi-do, Korea
2 shared publications
Latest Publications
- 1 April 2018
- Published by Elsevier in Environmental Toxicology and Pharmacology
- Vol. 59, 146-151
Urine Cotinine level with smoking history predicts a risk of coronary artery calcification
- 1 April 2018
- Published by Elsevier in Environmental Toxicology and Pharmacology
- Vol. 59, 146-151
Urine Cotinine level with smoking history predicts a risk of coronary artery calcification
- 1 January 2017
- Published by Elsevier in Gynecologic Oncology
- Vol. 144 (1) , 227
Corrigendum to ‘Diagnostic performance and establishment of reference limits of HE4 in Korean healthy women’ [Gynecol. Oncol. 143 (2016) 128–134]
- 1 January 2017
- Published by Elsevier in Gynecologic Oncology
- Vol. 144 (1) , 227
Corrigendum to ‘Diagnostic performance and establishment of reference limits of HE4 in Korean healthy women’ [Gynecol. Oncol. 143 (2016) 128–134]
- 1 October 2016
- Published by Elsevier in Gynecologic Oncology
- Vol. 143 (1) , 128-134
Diagnostic performance and establishment of reference limits of HE4 in Korean healthy women
- 1 October 2016
- Published by Elsevier in Gynecologic Oncology
- Vol. 143 (1) , 128-134
Diagnostic performance and establishment of reference limits of HE4 in Korean healthy women
- Open Access
- 1 September 2016
- Published by Annals of Laboratory Medicine in Annals of Laboratory Medicine
- Vol. 36 (5) , 427-432
Evaluation of Serum Cotinine Cut-Off to Distinguish Smokers From Nonsmokers in the Korean Population
Ko K, et al. Ann Lab Med. 2016 Sep;36(5):427-433. http://dx.doi.org/10.3343/alm.2016.36.5.427
- 1 September 2016
- Published by Annals of Laboratory Medicine in Annals of Laboratory Medicine
- Vol. 36 (5) , 427-432
Open AccessEvaluation of Serum Cotinine Cut-Off to Distinguish Smokers From Nonsmokers in the Korean Population
Ko K, et al. Ann Lab Med. 2016 Sep;36(5):427-433. http://dx.doi.org/10.3343/alm.2016.36.5.427
- 1 September 2016
- Vol. 46 (5) , 522-8
Comparison of Abbott RealTime High-Risk HPV and Hybrid Capture 2 Assays for Detection of HPV Infection.
Various assays for detecting high-risk human papillomavirus (HR HPV) have been introduced recently, including the Abbott RealTime High-Risk HPV assay. We sought to compare the performance of Abbott PCR to Hybrid Capture 2 for the detection of HR HPV. A total of 941 cervical swab specimens were obtained. We submitted all specimens for HR HPV detection with HC2 and Abbott PCR, and then additionally analyzed discordant and concordant positive results using restriction fragment mass polymorphism (RFMP) genotyping analysis. HC2 detected one of 13 HR HPV types in 12.3% (116/941) of cases, while Abbott PCR detected one of 14 detectable HR HPV types in 12.9% (121/941) of cases. The overall agreement rate was 97.3% with a kappa coefficient of 0.879. Discordant results between these two assays were observed in 25 cases. HC2 showed a sensitivity of 90.0% and specificity of 95.9%, while Abbott PCR showed a sensitivity of 98.0% and specificity of 96.8% when using RFMP results as the gold standard. For HPV 16/18 detection, Abbott PCR showed 95.8%/88.9% sensitivity and 99.2%/99.8% specificity, respectively. The overall coinfection rate between HPV 16, 18 and non-16/18 was 9.9% (12/121) in Abbott PCR analysis. Considering its high agreement rate with HC2, higher sensitivity/specificity compared to HC2, and ability to differentiate HPV 16/18 from other HPV types, Abbott PCR could be a reliable laboratory testing method for the screening of HPV infections.
- 1 September 2016
- Vol. 46 (5) , 522-8
Comparison of Abbott RealTime High-Risk HPV and Hybrid Capture 2 Assays for Detection of HPV Infection.
Various assays for detecting high-risk human papillomavirus (HR HPV) have been introduced recently, including the Abbott RealTime High-Risk HPV assay. We sought to compare the performance of Abbott PCR to Hybrid Capture 2 for the detection of HR HPV. A total of 941 cervical swab specimens were obtained. We submitted all specimens for HR HPV detection with HC2 and Abbott PCR, and then additionally analyzed discordant and concordant positive results using restriction fragment mass polymorphism (RFMP) genotyping analysis. HC2 detected one of 13 HR HPV types in 12.3% (116/941) of cases, while Abbott PCR detected one of 14 detectable HR HPV types in 12.9% (121/941) of cases. The overall agreement rate was 97.3% with a kappa coefficient of 0.879. Discordant results between these two assays were observed in 25 cases. HC2 showed a sensitivity of 90.0% and specificity of 95.9%, while Abbott PCR showed a sensitivity of 98.0% and specificity of 96.8% when using RFMP results as the gold standard. For HPV 16/18 detection, Abbott PCR showed 95.8%/88.9% sensitivity and 99.2%/99.8% specificity, respectively. The overall coinfection rate between HPV 16, 18 and non-16/18 was 9.9% (12/121) in Abbott PCR analysis. Considering its high agreement rate with HC2, higher sensitivity/specificity compared to HC2, and ability to differentiate HPV 16/18 from other HPV types, Abbott PCR could be a reliable laboratory testing method for the screening of HPV infections.
- 24 August 2015
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 30 (5) , 424-430
Performance Evaluation of Three URiSCAN Devices for Routine Urinalysis
Background: This study compares the diagnostic performance (in routine urinalysis) of three URiSCAN devices and three Roche analyzers to manual microscopy and quantitative assays.Methods: We analyzed eight dipstick tests using three URiSCAN devices. The results were compared to those of the tests performed using three Roche analyzers. The results of leukocyte and erythrocyte screens were compared to those obtained using manual microscopy. Protein, glucose, pH, and specific gravity (SG) assays performed on the URiSCAN devices were compared with the results of corresponding quantitative assays.Results: The rates of agreement within one grade difference were found to be more than 94.3%. When compared with manual microscopy, the Optima provided better diagnostic performance for the detection of leukocytes compared with the Urisys 1100. Compared to the Urisys 2400, the Super plus provided better diagnostic performance with regard to both leukocytes and erythrocytes. There was good correlation between the three URiSCAN devices and each quantitative assay, except for SG detection.Conclusion: There were well correlated results between those of the three URiSCAN devices and those obtained using the corresponding Roche analyzers, quantitative assays, and manual microscopy. URiSCAN series devices are therefore suitable for routine urinalysis in clinical laboratories.
- 24 August 2015
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 30 (5) , 424-430
Performance Evaluation of Three URiSCAN Devices for Routine Urinalysis
Background: This study compares the diagnostic performance (in routine urinalysis) of three URiSCAN devices and three Roche analyzers to manual microscopy and quantitative assays.Methods: We analyzed eight dipstick tests using three URiSCAN devices. The results were compared to those of the tests performed using three Roche analyzers. The results of leukocyte and erythrocyte screens were compared to those obtained using manual microscopy. Protein, glucose, pH, and specific gravity (SG) assays performed on the URiSCAN devices were compared with the results of corresponding quantitative assays.Results: The rates of agreement within one grade difference were found to be more than 94.3%. When compared with manual microscopy, the Optima provided better diagnostic performance for the detection of leukocytes compared with the Urisys 1100. Compared to the Urisys 2400, the Super plus provided better diagnostic performance with regard to both leukocytes and erythrocytes. There was good correlation between the three URiSCAN devices and each quantitative assay, except for SG detection.Conclusion: There were well correlated results between those of the three URiSCAN devices and those obtained using the corresponding Roche analyzers, quantitative assays, and manual microscopy. URiSCAN series devices are therefore suitable for routine urinalysis in clinical laboratories.
- Open Access
- 29 April 2015
- Published by Asian Pacific Organization for Cancer Prevention in Asian Pacific Journal of Cancer Prevention
- Vol. 16 (8) , 3167-3172
Investigation of Transition Types of HPV DNA Test Results over Time in Korean Women
Understanding the history of human papilloma virus (HPV) infection is important for interpretation of a positive HPV DNA screening test, future work-up and treatment. We investigated the transition of HPV DNA test results in Korean women, and analyzed the association of cytology result with transition type. We retrospectively reviewed annual HPV DNA test results for 5,274 subjects between January 2005 and December 2012. Each subject had a minimum of five annual tests over the eight-year period. Based on the pattern of results, the transition type for each subject was assigned to one of the following: negative, persistent, latent, transient, and unclassifiable. Associations of cytology results with the HPV DNA transition types, number of positive results, and the durations of positive results were also analyzed. The proportion of abnormal cytology findings decreased in the following order of transition patterns: persistent, latent, transient, and negative. Among transient patterns, a duration of three years or more significantly correlated with cytology results of non-high grade squamous intraepithelial lesion (HSIL; p<0.001). In the persistent group, duration of five years or more correlated with both non-HSIL and HSIL (p<0.001). Latent group showed no correlation with duration. Irrespective of patterns, having five or more positive results was significantly associated with HSIL (p<0.001). Our findings may contribute to better understanding of HPV infection, interpretation of HPV DNA screening results, and prediction of prognosis according to transition type.
- 29 April 2015
- Published by Asian Pacific Organization for Cancer Prevention in Asian Pacific Journal of Cancer Prevention
- Vol. 16 (8) , 3167-3172
Open AccessInvestigation of Transition Types of HPV DNA Test Results over Time in Korean Women
Understanding the history of human papilloma virus (HPV) infection is important for interpretation of a positive HPV DNA screening test, future work-up and treatment. We investigated the transition of HPV DNA test results in Korean women, and analyzed the association of cytology result with transition type. We retrospectively reviewed annual HPV DNA test results for 5,274 subjects between January 2005 and December 2012. Each subject had a minimum of five annual tests over the eight-year period. Based on the pattern of results, the transition type for each subject was assigned to one of the following: negative, persistent, latent, transient, and unclassifiable. Associations of cytology results with the HPV DNA transition types, number of positive results, and the durations of positive results were also analyzed. The proportion of abnormal cytology findings decreased in the following order of transition patterns: persistent, latent, transient, and negative. Among transient patterns, a duration of three years or more significantly correlated with cytology results of non-high grade squamous intraepithelial lesion (HSIL; p<0.001). In the persistent group, duration of five years or more correlated with both non-HSIL and HSIL (p<0.001). Latent group showed no correlation with duration. Irrespective of patterns, having five or more positive results was significantly associated with HSIL (p<0.001). Our findings may contribute to better understanding of HPV infection, interpretation of HPV DNA screening results, and prediction of prognosis according to transition type.
- 24 April 2015
- Published by Wiley in Journal of Medical Virology
- Vol. 87 (9) , 1587-1593
Comparison of clinical performances among Roche Cobas HPV, RFMP HPV PapilloTyper and Hybrid Capture 2 assays for detection of high-risk types of human papillomavirus
The cervical cancer screening guidelines suggest that early detection of HPV16 and HPV18 is helpful for identifying women with cervical intraepithelial neoplasia (CIN) grade two or higher. We comparatively evaluated three HPV DNA assays, Roche Cobas HPV, RFMP HPV PapilloTyper, and Hybrid Capture 2 (HC2). A total of 861 cervical swab samples from women over 30 years of age were classified into two groups, that is, high grade squamous intraepithelial lesion (HSIL) and non‐HSIL, according to cervical cytology results and analyzed by three assays. The results of direct sequencing or Linear array HPV genotyping test were considered true when the three assays presented discrepancies. The concordance rates between Roche Cobas HPV versus RFMP HPV PapilloTyper, RFMP HPV PapilloTyper versus HC2, and Roche Cobas versus HC2 were 94.5%, 94.3%, and 95.9%, respectively. For detection of HPV16 and HPV18, Roche Cobas HPV showed the concordance rates of 98.3% (κ = 0.73) and 99.4% (κ = 0.40) with the confirmation tests, respectively; and RFMP HPV PapilloTyper showed the concordance rates of 99.5% (κ = 0.92) and 100.0% (κ = 1.00), respectively. In conclusion, Roche Cobas HPV, RFMP HPV PapilloTyper, and HC2 showed high agreement rates. Roche Cobas HPV and RFMP HPV PapilloTyper are particularly useful, since both provide HPV specific genotypes, HPV16 and HPV18.
- 24 April 2015
- Published by Wiley in Journal of Medical Virology
- Vol. 87 (9) , 1587-1593
Comparison of clinical performances among Roche Cobas HPV, RFMP HPV PapilloTyper and Hybrid Capture 2 assays for detection of high-risk types of human papillomavirus
The cervical cancer screening guidelines suggest that early detection of HPV16 and HPV18 is helpful for identifying women with cervical intraepithelial neoplasia (CIN) grade two or higher. We comparatively evaluated three HPV DNA assays, Roche Cobas HPV, RFMP HPV PapilloTyper, and Hybrid Capture 2 (HC2). A total of 861 cervical swab samples from women over 30 years of age were classified into two groups, that is, high grade squamous intraepithelial lesion (HSIL) and non‐HSIL, according to cervical cytology results and analyzed by three assays. The results of direct sequencing or Linear array HPV genotyping test were considered true when the three assays presented discrepancies. The concordance rates between Roche Cobas HPV versus RFMP HPV PapilloTyper, RFMP HPV PapilloTyper versus HC2, and Roche Cobas versus HC2 were 94.5%, 94.3%, and 95.9%, respectively. For detection of HPV16 and HPV18, Roche Cobas HPV showed the concordance rates of 98.3% (κ = 0.73) and 99.4% (κ = 0.40) with the confirmation tests, respectively; and RFMP HPV PapilloTyper showed the concordance rates of 99.5% (κ = 0.92) and 100.0% (κ = 1.00), respectively. In conclusion, Roche Cobas HPV, RFMP HPV PapilloTyper, and HC2 showed high agreement rates. Roche Cobas HPV and RFMP HPV PapilloTyper are particularly useful, since both provide HPV specific genotypes, HPV16 and HPV18.
- 1 April 2014
- Published by Elsevier in Journal of Clinical Virology
- Vol. 59 (4) , 246-249
Comparison of the Anyplex II HPV28 assay with the Hybrid Capture 2 assay for the detection of HPV infection
- 1 April 2014
- Published by Elsevier in Journal of Clinical Virology
- Vol. 59 (4) , 246-249
Comparison of the Anyplex II HPV28 assay with the Hybrid Capture 2 assay for the detection of HPV infection
- 12 July 2013
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 27 (4) , 284-289
Measurement of Serum Total Vitamin D (25‐OH) Using Automated Immunoassay in Comparision With Liquid Chromatography Tandem‐Mass Spectrometry
Background: The associations of vitamin D deficiency with many nonskeletal diseases are still being discovered. We evaluated the use of an automated immunoassay to measure serum total vitamin D (25‐OH) and assessed vitamin D status in a Korean adult population.Methods: We compared the Elecsys Vitamin D (25‐OH) Total Assay (Roche Diagnostics) with liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) using 300 serum samples. Total imprecision was calculated using three levels of quality control materials and serum samples. We also investigated the vitamin D status using data for 70,762 cases who had a routine health check‐up in our hospitals.Results: The regression equation: Elecsys = 0.882 × LC‐MS/MS + 6.814 (r = 0.926). Total imprecision was within 10% for all quality control materials and serum samples. The prevalence of vitamin D deficiency using cut‐off values of P for linear‐by‐linear association was <0.001). Serum vitamin D levels were highest in September and lowest in February.Conclusion: The Elecsys Vitamin D (25‐OH) Total Assay was comparable to LC‐MS/MS and appropriate for routine clinical use. Vitamin D deficiency is common in Korean adults.
- 12 July 2013
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 27 (4) , 284-289
Measurement of Serum Total Vitamin D (25‐OH) Using Automated Immunoassay in Comparision With Liquid Chromatography Tandem‐Mass Spectrometry
Background: The associations of vitamin D deficiency with many nonskeletal diseases are still being discovered. We evaluated the use of an automated immunoassay to measure serum total vitamin D (25‐OH) and assessed vitamin D status in a Korean adult population.Methods: We compared the Elecsys Vitamin D (25‐OH) Total Assay (Roche Diagnostics) with liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) using 300 serum samples. Total imprecision was calculated using three levels of quality control materials and serum samples. We also investigated the vitamin D status using data for 70,762 cases who had a routine health check‐up in our hospitals.Results: The regression equation: Elecsys = 0.882 × LC‐MS/MS + 6.814 (r = 0.926). Total imprecision was within 10% for all quality control materials and serum samples. The prevalence of vitamin D deficiency using cut‐off values of P for linear‐by‐linear association was <0.001). Serum vitamin D levels were highest in September and lowest in February.Conclusion: The Elecsys Vitamin D (25‐OH) Total Assay was comparable to LC‐MS/MS and appropriate for routine clinical use. Vitamin D deficiency is common in Korean adults.