Chengjin Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Chengjin Du has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Weidong Wang
Harbin Institute of Technology
5 shared publications Dehao Wei
Tsinghua-Berkeley Shenzhen Institute (TBSI), Shenzhen, China
2 shared publicationsHan Wang
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, China
2 shared publications- Yulong Men
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, China
2 shared publications Chaoyi Yuan
1 shared publication- Dongdong Du
College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, China
1 shared publication
Latest Publications
- 17 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (23) , 38987-38995
Development of the X-Sketch: A Modular Skeleton Proprioception System for a Laparo-Endoscopic Single-Site Surgical Robot
The development of continuum robots with embedded sensing systems has been a research focus over the last decade. Specifically, for the robotic laparo-endoscopic single-site surgical (R-LESS) system, an economical solution that allows the integration of an electromagnetic-compatible shape-proprioception system is needed. In this article, we propose a modular sensing system named X-Sketch for the R-LESS system. The system comprises four fiber Bragg grating channels integrated with 3D-printed elastic joints that enable the detection of curvature variations. The modularity and customizability are achieved by the stacking design of the flexible joints and sensing units. The skeleton of the arm is constructed by an analytical kinematics process of the curvature information, during which a neural network is employed to perform the curvature regression. For the experiment, an R-LESS arm prototype integrated with the X-Sketch system is developed. Calibration and experimental evaluation are then conducted to assess the performance of the proposed sensing system. The results demonstrate the performance of the proposed system, achieving an average tip position error of 2.23±0.64mm, corresponding to <5% of the system’s length, suggesting the potential for X-Sketch application in R-LESS surgical operations.
- 17 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (23) , 38987-38995
Development of the X-Sketch: A Modular Skeleton Proprioception System for a Laparo-Endoscopic Single-Site Surgical Robot
The development of continuum robots with embedded sensing systems has been a research focus over the last decade. Specifically, for the robotic laparo-endoscopic single-site surgical (R-LESS) system, an economical solution that allows the integration of an electromagnetic-compatible shape-proprioception system is needed. In this article, we propose a modular sensing system named X-Sketch for the R-LESS system. The system comprises four fiber Bragg grating channels integrated with 3D-printed elastic joints that enable the detection of curvature variations. The modularity and customizability are achieved by the stacking design of the flexible joints and sensing units. The skeleton of the arm is constructed by an analytical kinematics process of the curvature information, during which a neural network is employed to perform the curvature regression. For the experiment, an R-LESS arm prototype integrated with the X-Sketch system is developed. Calibration and experimental evaluation are then conducted to assess the performance of the proposed sensing system. The results demonstrate the performance of the proposed system, achieving an average tip position error of 2.23±0.64mm, corresponding to <5% of the system’s length, suggesting the potential for X-Sketch application in R-LESS surgical operations.
- 30 August 2023
- Published by Elsevier in Journal of Food Engineering
- Vol. 360
A bioinspired setup to evaluate food graininess via tactile friction and vibration
- 30 August 2023
- Published by Elsevier in Journal of Food Engineering
- Vol. 360
A bioinspired setup to evaluate food graininess via tactile friction and vibration
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (7) , 10015-10023
FBG Sensors Monitoring Force and Deformation of the Traction Instrument in Pelvic Fracture Reduction Surgery
In robot-assisted pelvic fracture reduction surgery, precise control of the traction needle is essential for successful traction of the fractured bone to align with the anastomotic position. However, needle deformation during the procedure can compromise the navigation system’s accuracy, potentially causing over-traction, damage to adjacent tissues, and surgical failure. To address this issue, we propose a novel force sensing system that integrates Fiber Bragg Grating (FBG) sensors onto the traction needle, providing reliable mechanical feedback. The applied force on the needle is transduced through the wavelength shift of the FBGs, enabling the calculation of needle tip deformation using a mapping model correlating needle position offset and applied force. Experimental evaluation reveals the sensor’s high sensitivity in measuring lateral force (31.04 pm/N and 21.91 pm/N in the X and Y directions, respectively) and commendable tracking accuracy for both force and deformation (with errors of 3.74%FS full scale (FS) and 1.280 mm). The proposed sensing system’s efficacy is further demonstrated through robot-assisted pelvic reduction surgery on an artificial pelvis, confirming the sensor’s capability to accurately measure traction force and instrument deformation during the procedure.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (7) , 10015-10023
FBG Sensors Monitoring Force and Deformation of the Traction Instrument in Pelvic Fracture Reduction Surgery
In robot-assisted pelvic fracture reduction surgery, precise control of the traction needle is essential for successful traction of the fractured bone to align with the anastomotic position. However, needle deformation during the procedure can compromise the navigation system’s accuracy, potentially causing over-traction, damage to adjacent tissues, and surgical failure. To address this issue, we propose a novel force sensing system that integrates Fiber Bragg Grating (FBG) sensors onto the traction needle, providing reliable mechanical feedback. The applied force on the needle is transduced through the wavelength shift of the FBGs, enabling the calculation of needle tip deformation using a mapping model correlating needle position offset and applied force. Experimental evaluation reveals the sensor’s high sensitivity in measuring lateral force (31.04 pm/N and 21.91 pm/N in the X and Y directions, respectively) and commendable tracking accuracy for both force and deformation (with errors of 3.74%FS full scale (FS) and 1.280 mm). The proposed sensing system’s efficacy is further demonstrated through robot-assisted pelvic reduction surgery on an artificial pelvis, confirming the sensor’s capability to accurately measure traction force and instrument deformation during the procedure.
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (1) , 183-193
Development of the X-Perce—A Universal FBG-Based Force Sensing Kit for Laparoscopic Surgical Robot
For surgical robot, an independent contact sensing system can always provide intuitive operation reference in parallel to non-contact information. As one of them, force sensing system developed based on fiber Bragg grating sensor (FBGs) has been at the forefront of gaining force information from surgical device in the past decade. Application span from vitrectomy, cerebral surgery to cardiac ablation yet still rarely seen in laparoscopic surgery. In this paper, we present the development of the X-Perce—a force sensing kit that can be universally deployed on the laparoscopic surgical robot. By the design of a 3D-printed biocompatible joint combining with six FBGs layout, the proposed kit is able to perform tri-axial force sensing with temperature compensation and dual-thread mechanism. Modular design and standardized integration process are able to reduce the cost of manufacture, which allow the X-Perce to be consumable and commercial. Optimization based on mechanical modelling is implemented to enhance the system performance. Testing and evaluation is conducted to assess the resolution, static indexes and tracking performance of the prototype. Overall, we provide here a mechanical force sensing solution for the instrument that can be integrated on the Da-Vinci-like laparoscopic robotic system, along with a complete design paradigm for FBG sensing system alike.
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (1) , 183-193
Development of the X-Perce—A Universal FBG-Based Force Sensing Kit for Laparoscopic Surgical Robot
For surgical robot, an independent contact sensing system can always provide intuitive operation reference in parallel to non-contact information. As one of them, force sensing system developed based on fiber Bragg grating sensor (FBGs) has been at the forefront of gaining force information from surgical device in the past decade. Application span from vitrectomy, cerebral surgery to cardiac ablation yet still rarely seen in laparoscopic surgery. In this paper, we present the development of the X-Perce—a force sensing kit that can be universally deployed on the laparoscopic surgical robot. By the design of a 3D-printed biocompatible joint combining with six FBGs layout, the proposed kit is able to perform tri-axial force sensing with temperature compensation and dual-thread mechanism. Modular design and standardized integration process are able to reduce the cost of manufacture, which allow the X-Perce to be consumable and commercial. Optimization based on mechanical modelling is implemented to enhance the system performance. Testing and evaluation is conducted to assess the resolution, static indexes and tracking performance of the prototype. Overall, we provide here a mechanical force sensing solution for the instrument that can be integrated on the Da-Vinci-like laparoscopic robotic system, along with a complete design paradigm for FBG sensing system alike.
- 1 October 2020
- Published by Elsevier in Robotics and Autonomous Systems
- Vol. 132
A novel odor source localization system based on particle filtering and information entropy
- 1 October 2020
- Published by Elsevier in Robotics and Autonomous Systems
- Vol. 132
A novel odor source localization system based on particle filtering and information entropy
- 28 June 2019
- Published by Emerald Publishing in Industrial Robot: the international journal of robotics research and application
- Vol. 46 (5) , 599-607
A medical transportation robot for carrying and positioning patients between different devices
Purpose: This paper aims to present a prototype of medical transportation robot whose positioning accuracy can reach millimeter-level in terms of patient transportation. By using this kind of mobile robot, a fully automatic image diagnosis process among independent CT/PET devices and the image fusion can be achieved. Design/methodology/approach: Following a short introduction, a large-load 4WD-4WS (four-wheel driving and four-wheel steering) mobile robot for carrying patient among multiple medical imaging equipments is developed. At the same time, a specially designed bedplate with self-locking function is also introduced. For further improving the positioning accuracy, the authors proposed a calibration method based on Gaussian process regression (GPR) to process the measuring data of the sensors. The performance of this robot is verified by the calibration experiment and Image fusion experiment. Finally, concluding comments are drawn. Findings: By calibrating the robot’s positioning system through the proposed GPR method, one can obtain the accuracy of the robot’s offset distance and deflection angle, which are 0.50 mm and +0.21°, respectively. Independent repeated trials were then set up to verify this result. Subsequent phantom experiment shows the accuracy of image fusion can be accurate within 0.57 mm in the front-rear direction and 0.83 in the left-right direction, respectively, while the clinical experiment shows that the proposed robot can practically realize the transportation of patient and image fusion between multiple imaging diagnosis devices. Practical implications: The proposed robot offers an economical image fusion solution for medical institutions whose imaging diagnosis system basically comprises independent MRI, CT and PET devices. Also, a fully automatic diagnosis process can be achieved so that the patient’s suffering of getting in and out of the bed and the doctor’s radiation dose can be obviated. Social implications: The general bedplate presented in Section 2 that can be mounted on the CT and PET devices and the self-locking mechanism has realized the catching and releasing motion of the patient on different medical devices. They also provide a detailed method regarding patient handling and orientation maintenance, which was hardly mentioned in previous research. By establishing the positioning system between the robot and different medical equipment, a fully automatic diagnosis process can be achieved so that the patient’s suffering of getting in and out of the bed and the doctor’s radiation dose can be obviated. Originality/value: The GPR-based method proposed in this paper offers a novel method for enhancing the positioning accuracy of the industrial AGV while the transportation robot proposed in this paper also offers a solution for modern imaging fusion diagnosis, which are basically predicated on the conjoint analysis between different kinds of medical devices.
- 28 June 2019
- Published by Emerald Publishing in Industrial Robot: the international journal of robotics research and application
- Vol. 46 (5) , 599-607
A medical transportation robot for carrying and positioning patients between different devices
Purpose: This paper aims to present a prototype of medical transportation robot whose positioning accuracy can reach millimeter-level in terms of patient transportation. By using this kind of mobile robot, a fully automatic image diagnosis process among independent CT/PET devices and the image fusion can be achieved. Design/methodology/approach: Following a short introduction, a large-load 4WD-4WS (four-wheel driving and four-wheel steering) mobile robot for carrying patient among multiple medical imaging equipments is developed. At the same time, a specially designed bedplate with self-locking function is also introduced. For further improving the positioning accuracy, the authors proposed a calibration method based on Gaussian process regression (GPR) to process the measuring data of the sensors. The performance of this robot is verified by the calibration experiment and Image fusion experiment. Finally, concluding comments are drawn. Findings: By calibrating the robot’s positioning system through the proposed GPR method, one can obtain the accuracy of the robot’s offset distance and deflection angle, which are 0.50 mm and +0.21°, respectively. Independent repeated trials were then set up to verify this result. Subsequent phantom experiment shows the accuracy of image fusion can be accurate within 0.57 mm in the front-rear direction and 0.83 in the left-right direction, respectively, while the clinical experiment shows that the proposed robot can practically realize the transportation of patient and image fusion between multiple imaging diagnosis devices. Practical implications: The proposed robot offers an economical image fusion solution for medical institutions whose imaging diagnosis system basically comprises independent MRI, CT and PET devices. Also, a fully automatic diagnosis process can be achieved so that the patient’s suffering of getting in and out of the bed and the doctor’s radiation dose can be obviated. Social implications: The general bedplate presented in Section 2 that can be mounted on the CT and PET devices and the self-locking mechanism has realized the catching and releasing motion of the patient on different medical devices. They also provide a detailed method regarding patient handling and orientation maintenance, which was hardly mentioned in previous research. By establishing the positioning system between the robot and different medical equipment, a fully automatic diagnosis process can be achieved so that the patient’s suffering of getting in and out of the bed and the doctor’s radiation dose can be obviated. Originality/value: The GPR-based method proposed in this paper offers a novel method for enhancing the positioning accuracy of the industrial AGV while the transportation robot proposed in this paper also offers a solution for modern imaging fusion diagnosis, which are basically predicated on the conjoint analysis between different kinds of medical devices.
- Open Access
- 9 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 48655-48670
A PSO-Optimized Fuzzy Reinforcement Learning Method for Making the Minimally Invasive Surgical Arm Cleverer
For robotic-assisted surgery, the preoperative preparation procedure within which the surgical arms need to be adjusted manually to their expected configuration can pose interlocking problems in terms of accuracy, system robustness, and human-robot interaction experience. Previous work about variable impedance/admittance control methods did improve the smoothness of this procedure while individual characteristics of different operating personnel haven’t yet been adequately considered. To further improve this process on the basis of existing methods, a novel strategy based on fuzzy Sarsa( $\lambda $ )-learning algorithm is both proposed and incorporated into the virtual parameter adjustment strategy to achieve physical human–robot interaction (pHRI) so that the robot can acclimatize various handling characteristics of different operators through enough online learning. To also shorten the online training cycle, reduce the undesirable subjective factors and improve the overall training performance, a particle-swarm-optimization-based (PSO-based) algorithm is as well employed for optimizing the partition of state variable space and the distribution of discrete actions. Several groups of experiments have demonstrated the validity of this scheme and the effectiveness of the PSO optimization element.
- 9 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 48655-48670
Open AccessA PSO-Optimized Fuzzy Reinforcement Learning Method for Making the Minimally Invasive Surgical Arm Cleverer
For robotic-assisted surgery, the preoperative preparation procedure within which the surgical arms need to be adjusted manually to their expected configuration can pose interlocking problems in terms of accuracy, system robustness, and human-robot interaction experience. Previous work about variable impedance/admittance control methods did improve the smoothness of this procedure while individual characteristics of different operating personnel haven’t yet been adequately considered. To further improve this process on the basis of existing methods, a novel strategy based on fuzzy Sarsa( $\lambda $ )-learning algorithm is both proposed and incorporated into the virtual parameter adjustment strategy to achieve physical human–robot interaction (pHRI) so that the robot can acclimatize various handling characteristics of different operators through enough online learning. To also shorten the online training cycle, reduce the undesirable subjective factors and improve the overall training performance, a particle-swarm-optimization-based (PSO-based) algorithm is as well employed for optimizing the partition of state variable space and the distribution of discrete actions. Several groups of experiments have demonstrated the validity of this scheme and the effectiveness of the PSO optimization element.