Mario Bragadireanu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mario Bragadireanu has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Clozza
Laboratori Nazionali di Frascati, Istituto Nazionale di Fisica Nucleare, Via E. Fermi 40, 00044 Frascati, Italy
8 shared publications - Alessandro Scordo
Laboratori Nazionali di Frascati INFN, Frascati, Italy
8 shared publications - Carlo Guaraldo
Laboratori Nazionali di Frascati, INFN, Via E. Fermi 54, 00044 Frascati, Italy
8 shared publications - Catalina Curceanu
Laboratori Nazionali di Frascati, INFN, Frascati, Italy
8 shared publications - Diana Laura Sirghi
Laboratori Nazionali di Frascati INFN Frascati Italy
8 shared publications - Johann Marton
Stefan-Meyer-Institut für Subatomare Physik, Dominikanerbastei 16, 1010 Wien, Austria
8 shared publications
Latest Publications
- Open Access
First Stability Characterization for a CZT Detection System in an e+e− Collider Environment
The SIDDHARTA-2 collaboration has developed a novel X-ray detection system based on cadmium-zinc-telluride (CZT, CdZnTe), marking the first application of this technology at the DANE electron-positron collider at INFN-LNF. This work aims to demonstrate the stability of the detectors’ performance in terms of linearity and resolution over short and long periods, thereby establishing their suitability for precise spectroscopic measurements within a collider environment. A reference calibration spectrum is presented in association with findings from assessments of linearity and resolution stability. Additionally, this study introduces a validated model of the response function of the detector. The relative deviations from the nominal values for the source transitions, obtained by fitting the entire spectrum with a background function and the previously introduced response function, are reported. Finally, a comparison of the calibration performance with and without beams circulating in the collider’s rings is presented. These promising results pave the way for applying CZT detectors in kaonic atom studies and, more generally, in particle and nuclear physics spectroscopy.Open AccessFirst Stability Characterization for a CZT Detection System in an e+e− Collider Environment
The SIDDHARTA-2 collaboration has developed a novel X-ray detection system based on cadmium-zinc-telluride (CZT, CdZnTe), marking the first application of this technology at the DANE electron-positron collider at INFN-LNF. This work aims to demonstrate the stability of the detectors’ performance in terms of linearity and resolution over short and long periods, thereby establishing their suitability for precise spectroscopic measurements within a collider environment. A reference calibration spectrum is presented in association with findings from assessments of linearity and resolution stability. Additionally, this study introduces a validated model of the response function of the detector. The relative deviations from the nominal values for the source transitions, obtained by fitting the entire spectrum with a background function and the previously introduced response function, are reported. Finally, a comparison of the calibration performance with and without beams circulating in the collider’s rings is presented. These promising results pave the way for applying CZT detectors in kaonic atom studies and, more generally, in particle and nuclear physics spectroscopy. - Open Access
- 11 April 2024
- Published by MDPI AG in Condensed Matter
- Vol. 9 (2) , 22
Optimization of a BEGe Detector Setup for Testing Quantum Foundations in the Underground LNGS Laboratory
In this work, we report on tests performed with an experimental apparatus prototype based on a broad-energy germanium detector aimed at investigating topical, foundational issues in quantum mechanics: i.e., possible violations of the spin-statistics connection and models of dynamical wave function collapse. Our recent phenomenological analyses demonstrated the importance of pushing the research of new physics signal, predicted in these fields, to an energy range below 10 keV. We describe the development of the dedicated data acquisition system and of the pulse shape discrimination algorithm, which have already allowed us to get a factor two improvement in the lower energy threshold. Future plans are discussed to further improve the lower energy threshold to the level of a few keV.
- 11 April 2024
- Published by MDPI AG in Condensed Matter
- Vol. 9 (2) , 22
Open AccessOptimization of a BEGe Detector Setup for Testing Quantum Foundations in the Underground LNGS Laboratory
In this work, we report on tests performed with an experimental apparatus prototype based on a broad-energy germanium detector aimed at investigating topical, foundational issues in quantum mechanics: i.e., possible violations of the spin-statistics connection and models of dynamical wave function collapse. Our recent phenomenological analyses demonstrated the importance of pushing the research of new physics signal, predicted in these fields, to an energy range below 10 keV. We describe the development of the dedicated data acquisition system and of the pulse shape discrimination algorithm, which have already allowed us to get a factor two improvement in the lower energy threshold. Future plans are discussed to further improve the lower energy threshold to the level of a few keV.
- Open Access
- 28 February 2024
- Published by MDPI AG in Condensed Matter
- Vol. 9 (1) , 16
Characterization of the SIDDHARTA-2 Setup via the Kaonic Helium Measurement
The aim of the SIDDHARTA-2 experiment is to perform the first measurement ever of the width and shift induced by the strong interaction to the energy transition of kaonic deuterium. This ambitious goal implies a challenging task due to the very low X-ray yield of kaonic deuterium, which is why an accurate and thorough characterization of the experimental apparatus is mandatory before starting the data-taking campaign. Helium-4 is an excellent candidate for this characterization since it exhibits a high yield in particular for the transition, roughly 100 times greater than that of the kaonic deuterium. The ultimate goal of the work reported in this paper is to study the performances of the full experimental setup in view of the kaonic deuterium measurement. This is carried out by measuring the values of the shift and the width for the energy transition of kaonic helium-4, induced by the strong interaction. The values obtained for these quantities, for a total integrated luminosity of ∼31/, are and . The results, compared to the value of the shift measured by the SIDDHARTA experiment , show a net enhancement of the resolution of the apparatus, providing strong evidence of the potential to perform the challenging measurement of the kaonic deuterium.- 28 February 2024
- Published by MDPI AG in Condensed Matter
- Vol. 9 (1) , 16
Open AccessCharacterization of the SIDDHARTA-2 Setup via the Kaonic Helium Measurement
The aim of the SIDDHARTA-2 experiment is to perform the first measurement ever of the width and shift induced by the strong interaction to the energy transition of kaonic deuterium. This ambitious goal implies a challenging task due to the very low X-ray yield of kaonic deuterium, which is why an accurate and thorough characterization of the experimental apparatus is mandatory before starting the data-taking campaign. Helium-4 is an excellent candidate for this characterization since it exhibits a high yield in particular for the transition, roughly 100 times greater than that of the kaonic deuterium. The ultimate goal of the work reported in this paper is to study the performances of the full experimental setup in view of the kaonic deuterium measurement. This is carried out by measuring the values of the shift and the width for the energy transition of kaonic helium-4, induced by the strong interaction. The values obtained for these quantities, for a total integrated luminosity of ∼31/, are and . The results, compared to the value of the shift measured by the SIDDHARTA experiment , show a net enhancement of the resolution of the apparatus, providing strong evidence of the potential to perform the challenging measurement of the kaonic deuterium. - Open Access
Potentialities of CdZnTe Quasi-Hemispherical Detectors for Hard X-ray Spectroscopy of Kaonic Atoms at the DAΦNE Collider
Kaonic atom X-ray spectroscopy is a consolidated technique for investigations on the physics of strong kaon–nucleus/nucleon interaction. Several experiments have been conducted regarding the measurement of soft X-ray emission (20 keV) from intermediate kaonic atoms (carbon, aluminum, and sulfur). In this context, we investigated cadmium–zinc–telluride (CdZnTe or CZT) detectors, which have recently demonstrated high-resolution capabilities for hard X-ray and gamma-ray detection. A demonstrator prototype based on a new cadmium–zinc–telluride quasi-hemispherical detector and custom digital pulse processing electronics was developed. The detector covered a detection area of 1 cm2 with a single readout channel and interesting room-temperature performance with energy resolution of 4.4% (2.6 keV), 3% (3.7 keV), and 1.4% (9.3 keV) FWHM at 59.5, 122.1, and 662 keV, respectively. The results from X-ray measurements at the DAΦNE collider at the INFN National Laboratories of Frascati (Italy) are also presented with particular attention to the effects and rejection of electromagnetic and hadronic background.
Open AccessPotentialities of CdZnTe Quasi-Hemispherical Detectors for Hard X-ray Spectroscopy of Kaonic Atoms at the DAΦNE Collider
Kaonic atom X-ray spectroscopy is a consolidated technique for investigations on the physics of strong kaon–nucleus/nucleon interaction. Several experiments have been conducted regarding the measurement of soft X-ray emission (20 keV) from intermediate kaonic atoms (carbon, aluminum, and sulfur). In this context, we investigated cadmium–zinc–telluride (CdZnTe or CZT) detectors, which have recently demonstrated high-resolution capabilities for hard X-ray and gamma-ray detection. A demonstrator prototype based on a new cadmium–zinc–telluride quasi-hemispherical detector and custom digital pulse processing electronics was developed. The detector covered a detection area of 1 cm2 with a single readout channel and interesting room-temperature performance with energy resolution of 4.4% (2.6 keV), 3% (3.7 keV), and 1.4% (9.3 keV) FWHM at 59.5, 122.1, and 662 keV, respectively. The results from X-ray measurements at the DAΦNE collider at the INFN National Laboratories of Frascati (Italy) are also presented with particular attention to the effects and rejection of electromagnetic and hadronic background.
- Open Access
A Novel Approach to Parameter Determination of the Continuous Spontaneous Localization Collapse Model
Models of dynamical wave function collapse consistently describe the breakdown of the quantum superposition with the growing mass of the system by introducing non-linear and stochastic modifications to the standard Schrödinger dynamics. Among them, Continuous Spontaneous Localization (CSL) was extensively investigated both theoretically and experimentally. Measurable consequences of the collapse phenomenon depend on different combinations of the phenomenological parameters of the model—the strength and the correlation length —and have led, so far, to the exclusion of regions of the admissible () parameters space. We developed a novel approach to disentangle the and probability density functions, which discloses a more profound statistical insight.Open AccessA Novel Approach to Parameter Determination of the Continuous Spontaneous Localization Collapse Model
Models of dynamical wave function collapse consistently describe the breakdown of the quantum superposition with the growing mass of the system by introducing non-linear and stochastic modifications to the standard Schrödinger dynamics. Among them, Continuous Spontaneous Localization (CSL) was extensively investigated both theoretically and experimentally. Measurable consequences of the collapse phenomenon depend on different combinations of the phenomenological parameters of the model—the strength and the correlation length —and have led, so far, to the exclusion of regions of the admissible () parameters space. We developed a novel approach to disentangle the and probability density functions, which discloses a more profound statistical insight. - Open Access
- 25 November 2021
- Published by MDPI AG in Condensed Matter
- Vol. 6 (4) , 47
Silicon Drift Detectors’ Spectroscopic Response during the SIDDHARTA-2 Kaonic Helium Run at the DAΦNE Collider
A large-area silicon drift detectors (SDDs) system has been developed by the SIDDHARTA-2 collaboration for high precision light kaonic atom X-ray spectroscopy at the DANE collider of Istituto Nazionale di Fisica Nucleare—Laboratori Nazionali di Frascati. The SDDs’ geometry and electric field configuration, combined with their read-out electronics, make these devices suitable for performing high precision light kaonic atom spectroscopy measurements in the background of the DANE collider. This work presents the spectroscopic response of the SDDs system during the first exotic atoms run of SIDDHARTA-2 with kaonic helium, a preliminary to the kaonic deuterium data taking campaign. The SIDDHARTA-2 spectroscopic system has good energy resolution and a 2 μs timing window which rejects the asynchronous events, scaling the background by a factor of . The results obtained for the first exotic atoms run of SIDDHARTA-2 prove this system to be ready to perform the challenging kaonic deuterium measurement.- 25 November 2021
- Published by MDPI AG in Condensed Matter
- Vol. 6 (4) , 47
Open AccessSilicon Drift Detectors’ Spectroscopic Response during the SIDDHARTA-2 Kaonic Helium Run at the DAΦNE Collider
A large-area silicon drift detectors (SDDs) system has been developed by the SIDDHARTA-2 collaboration for high precision light kaonic atom X-ray spectroscopy at the DANE collider of Istituto Nazionale di Fisica Nucleare—Laboratori Nazionali di Frascati. The SDDs’ geometry and electric field configuration, combined with their read-out electronics, make these devices suitable for performing high precision light kaonic atom spectroscopy measurements in the background of the DANE collider. This work presents the spectroscopic response of the SDDs system during the first exotic atoms run of SIDDHARTA-2 with kaonic helium, a preliminary to the kaonic deuterium data taking campaign. The SIDDHARTA-2 spectroscopic system has good energy resolution and a 2 μs timing window which rejects the asynchronous events, scaling the background by a factor of . The results obtained for the first exotic atoms run of SIDDHARTA-2 prove this system to be ready to perform the challenging kaonic deuterium measurement. - Open Access
Kaonic Atoms to Investigate Global Symmetry Breaking
Kaonic atoms measure the antikaon-nucleus interaction at almost zero relative energy, allowing one to determine basic low-energy quantum chromodynamics (QCD) quantities, namely, the antikaon-nucleon ( N) scattering lengths. The latter are important for extracting the sigma terms which are built on the symmetry breaking part of the Hamiltonian, thereby providing a measure of chiral and SU(3) symmetries breaking. After discussing the sigma terms and their relations to the kaonic atoms, we describe the most precise measurement in the literature of kaonic hydrogen, performed at LNF-INFN by the SIDDHARTA experiment. Kaonic deuterium is still to be measured, and two experiments are planned. The first, SIDDHARTA-2 at LNF-INFN was installed on DA NE in spring 2019 and will collect data in 2020. The second, E57 at J-PARC, will become operative in 2021.Open AccessKaonic Atoms to Investigate Global Symmetry Breaking
Kaonic atoms measure the antikaon-nucleus interaction at almost zero relative energy, allowing one to determine basic low-energy quantum chromodynamics (QCD) quantities, namely, the antikaon-nucleon ( N) scattering lengths. The latter are important for extracting the sigma terms which are built on the symmetry breaking part of the Hamiltonian, thereby providing a measure of chiral and SU(3) symmetries breaking. After discussing the sigma terms and their relations to the kaonic atoms, we describe the most precise measurement in the literature of kaonic hydrogen, performed at LNF-INFN by the SIDDHARTA experiment. Kaonic deuterium is still to be measured, and two experiments are planned. The first, SIDDHARTA-2 at LNF-INFN was installed on DA NE in spring 2019 and will collect data in 2020. The second, E57 at J-PARC, will become operative in 2021. - Open Access
- 25 April 2019
- Published by MDPI AG in Condensed Matter
- Vol. 4 (2) , 42
X-ray Detectors for Kaonic Atoms Research at DAΦNE
This article presents the kaonic atom studies performed at the INFN National Laboratory of Frascati (Laboratori Nazionali di Frascati dell’INFN, LNF-INFN) since the opening of this field of research at the DA NE collider in early 2000. Significant achievements have been obtained by the DA NE Exotic Atom Research (DEAR) and Silicon Drift Detector for Hadronic Atom Research by Timing Applications (SIDDHARTA) experiments on kaonic hydrogen, which have required the development of novel X-ray detectors. The 2019 installation of the new SIDDHARTA-2 experiment to measure kaonic deuterium for the first time has been made possible by further technological advances in X-ray detection.- 25 April 2019
- Published by MDPI AG in Condensed Matter
- Vol. 4 (2) , 42
Open AccessX-ray Detectors for Kaonic Atoms Research at DAΦNE
This article presents the kaonic atom studies performed at the INFN National Laboratory of Frascati (Laboratori Nazionali di Frascati dell’INFN, LNF-INFN) since the opening of this field of research at the DA NE collider in early 2000. Significant achievements have been obtained by the DA NE Exotic Atom Research (DEAR) and Silicon Drift Detector for Hadronic Atom Research by Timing Applications (SIDDHARTA) experiments on kaonic hydrogen, which have required the development of novel X-ray detectors. The 2019 installation of the new SIDDHARTA-2 experiment to measure kaonic deuterium for the first time has been made possible by further technological advances in X-ray detection.