Atsuko Ohki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Atsuko Ohki has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Hirohisa Takeuchi
Department of Gastroenterological and General Surgery, Kyorin University Faculty of Medicine, Tokyo, Japan
3 shared publicationsNobutsugu Abe
Department of Gastroenterological and General Surgery, Kyorin University Faculty of Medicine, Tokyo, Japan
3 shared publicationsYoshikazu Hashimoto
Department of Gastroenterological and General Surgery, Kyorin University Faculty of Medicine, Tokyo, Japan
3 shared publicationsGen Nagao
Department of Gastroenterological and General Surgery, Kyorin University Faculty of Medicine, Mitaka, Japan
2 shared publications- Hirohisa Takeuchi
Department of Surgery, Kyorin University Faculty of Medicine, Tokyo, Japan
2 shared publications Masanao Tsurumi
Department of Gastroenterological and General Surgery, Kyorin University Faculty of Medicine, Tokyo, Japan
2 shared publications
Latest Publications
- Open Access
- 4 January 2024
- Published by Springer Nature in World Journal of Surgical Oncology
- Vol. 22 (1) , 1-8
Intragastric free cancer cells may be attached to automatic staplers during anastomosis in patients with gastric cancer
Automatic staplers are often used to reconstruct the digestive tract during surgeries for gastric cancer. Intragastric free cancer cells adhering to automatic staplers may come in contact with the laparoscopic port area and progress to port site recurrence. This study aimed to investigate the presence/absence of cancer cells adhering to automatic staplers during gastric cancer surgery using cytological examinations. We further determined the positive predictive clinicopathological factors and clinical implications of free cancer cells attached to automatic staplers. This study included 101 patients who underwent distal gastrectomy for gastric cancer. Automatic staplers used for anastomosis in gastric cancer surgeries were shaken in 150 ml of saline solution to collect the attached cells. Papanicolaou stains were performed. We tested the correlation between cancer-cell positivity and clinicopathological factors to identify risk factors arising from the presence of attached cancer cells to the staplers. Based on the cytology, cancer cells were detected in 7 of 101 (6.9%) stapler washing fluid samples. Univariate analysis revealed that circular staplers, type 1 tumors, and positive lymph nodes were significantly associated with higher detection of free cancer cells adhering to staplers. No significant differences in other factors were detected. Of the seven cases with positive cytology, one developed anastomotic recurrence. Exfoliated cancer cells adhered to the automatic staplers used for anastomoses in 6.9% of the staplers used for distal gastrectomies in patients with gastric cancer. Staplers used for gastric cancer surgeries should be handled carefully.
- 4 January 2024
- Published by Springer Nature in World Journal of Surgical Oncology
- Vol. 22 (1) , 1-8
Open AccessIntragastric free cancer cells may be attached to automatic staplers during anastomosis in patients with gastric cancer
Automatic staplers are often used to reconstruct the digestive tract during surgeries for gastric cancer. Intragastric free cancer cells adhering to automatic staplers may come in contact with the laparoscopic port area and progress to port site recurrence. This study aimed to investigate the presence/absence of cancer cells adhering to automatic staplers during gastric cancer surgery using cytological examinations. We further determined the positive predictive clinicopathological factors and clinical implications of free cancer cells attached to automatic staplers. This study included 101 patients who underwent distal gastrectomy for gastric cancer. Automatic staplers used for anastomosis in gastric cancer surgeries were shaken in 150 ml of saline solution to collect the attached cells. Papanicolaou stains were performed. We tested the correlation between cancer-cell positivity and clinicopathological factors to identify risk factors arising from the presence of attached cancer cells to the staplers. Based on the cytology, cancer cells were detected in 7 of 101 (6.9%) stapler washing fluid samples. Univariate analysis revealed that circular staplers, type 1 tumors, and positive lymph nodes were significantly associated with higher detection of free cancer cells adhering to staplers. No significant differences in other factors were detected. Of the seven cases with positive cytology, one developed anastomotic recurrence. Exfoliated cancer cells adhered to the automatic staplers used for anastomoses in 6.9% of the staplers used for distal gastrectomies in patients with gastric cancer. Staplers used for gastric cancer surgeries should be handled carefully.
- 3 February 2022
- Published by Springer Nature in Clinical Journal of Gastroenterology
- Vol. 15 (1) , 90-94
Early-stage gastric cancer with solitary brain metastasis four years after curative surgery: a case report and literature review
Brain metastasis post-curative gastrectomy for early-stage gastric cancer is extremely rare. We present herein, a case of solitary brain metastasis that developed 4 years post-curative surgery for early-stage gastric cancer. A 60-year-old man had early-stage gastric cancer 4 years prior to presentation and underwent laparoscopy-assisted distal gastrectomy with lymph node dissection. The pathological TNM classification was T1b (submucosal) N0M0. He underwent scheduled examinations and had no recurrence. 4 years postoperatively, he presented to the emergency department with sudden onset of nausea, vomiting, and inability to speak clearly. Brain computed tomography revealed a 17-mm nodule in the right cerebral hemisphere and midline shift. The tumor could not be radically resected for anatomical reasons, and incisional biopsy was performed for histological examination. Histological examination confirmed the diagnosis of a poorly differentiated adenocarcinoma from the previous gastric cancer. Gamma knife radiosurgery and chemotherapy were scheduled. 28 months after brain metastasis, multiple liver and lung metastases appeared. The patient died 30 months after developing brain metastasis. Brain metastasis may occur during long-term follow-up even after curative resection of early-stage gastric cancer. In patients with a history of gastric cancer and neurological symptoms, brain metastasis should be considered.
- 3 February 2022
- Published by Springer Nature in Clinical Journal of Gastroenterology
- Vol. 15 (1) , 90-94
Early-stage gastric cancer with solitary brain metastasis four years after curative surgery: a case report and literature review
Brain metastasis post-curative gastrectomy for early-stage gastric cancer is extremely rare. We present herein, a case of solitary brain metastasis that developed 4 years post-curative surgery for early-stage gastric cancer. A 60-year-old man had early-stage gastric cancer 4 years prior to presentation and underwent laparoscopy-assisted distal gastrectomy with lymph node dissection. The pathological TNM classification was T1b (submucosal) N0M0. He underwent scheduled examinations and had no recurrence. 4 years postoperatively, he presented to the emergency department with sudden onset of nausea, vomiting, and inability to speak clearly. Brain computed tomography revealed a 17-mm nodule in the right cerebral hemisphere and midline shift. The tumor could not be radically resected for anatomical reasons, and incisional biopsy was performed for histological examination. Histological examination confirmed the diagnosis of a poorly differentiated adenocarcinoma from the previous gastric cancer. Gamma knife radiosurgery and chemotherapy were scheduled. 28 months after brain metastasis, multiple liver and lung metastases appeared. The patient died 30 months after developing brain metastasis. Brain metastasis may occur during long-term follow-up even after curative resection of early-stage gastric cancer. In patients with a history of gastric cancer and neurological symptoms, brain metastasis should be considered.
- 1 March 2020
- Published by Wiley in Pediatrics International
- Vol. 62 (3) , 401-402
Extraction of buried and covered foreign body in esophagus using endoscopic submucosal dissection devices
- 1 March 2020
- Published by Wiley in Pediatrics International
- Vol. 62 (3) , 401-402
Extraction of buried and covered foreign body in esophagus using endoscopic submucosal dissection devices
- 25 April 2018
- Published by Springer Nature in Gastric Cancer
- Vol. 21 (6) , 998-1003
Gastric washing by distilled water can reduce free gastric cancer cells exfoliated into the stomach lumen
Intragastric free cancer cells in patients with gastric cancer have rarely been studied. The purpose of this study was to investigate the detection rate of intragastric free cancer cells in gastric washes using two types of solutions during endoscopic examination. We further clarified risk factors affecting the presence of exfoliated free cancer cells.
- 25 April 2018
- Published by Springer Nature in Gastric Cancer
- Vol. 21 (6) , 998-1003
Gastric washing by distilled water can reduce free gastric cancer cells exfoliated into the stomach lumen
Intragastric free cancer cells in patients with gastric cancer have rarely been studied. The purpose of this study was to investigate the detection rate of intragastric free cancer cells in gastric washes using two types of solutions during endoscopic examination. We further clarified risk factors affecting the presence of exfoliated free cancer cells.
- 17 September 2011
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 19 (4) , 426-430
Single‐incision multiport laparoendoscopic surgery using a newly developed short‐type flexible endoscope: a combined procedure of flexible endoscopic and laparoscopic surgery
Background and objective: We hypothesized that using a flexible endoscope as a working scope in laparoscopic surgery through a single incision might provide many benefits. To this end, a short‐type flexible endoscope with a working length of 600 mm was newly developed. In this animal experimental study, we aimed to evaluate the technical feasibility of our new approach, single‐incision multiport laparoendoscopic (SIMPLE) cholecystectomy, using this endoscope.Methods: Eight pigs were subjected to SIMPLE cholecystectomy using the short‐type flexible endoscope. The endoscope was inserted through a 12‐mm trocar in an SILS™ Port followed by the insertion of two additional 5‐mm trocars in the SILS™ Port. Encirculation and ligation of the pedicle of the cystic artery and duct were carried out using laparoscopic instruments through the 5‐mm trocars, while the dissection of the gallbladder from the intrahepatic fossa was predominantly performed using a cutting device through the endoscope.Results: A complete gallbladder excision, with complete encirculation and ligation of the pedicle, was completed in all cases. The mean operating time was 58 min (range 34—78 min). The endoscope provided a good view of the operating field, and it allowed some degree of freedom to the working laparoscopic instruments without compromising the field of view. Dissection of the gallbladder using the cutting device through the endoscope was much easier than that using the laparoscopic device, because the articulating instruments together with the endoscope enabled operation with triangulation. Furthermore, the water‐jet and suctioning functions and the self‐cleaning lens capability of the endoscope served the surgery well.Conclusions: SIMPLE cholecystectomy using the newly developed short‐type flexible endoscope is a technically feasible procedure. Using this flexible endoscope for various tasks, such as resection, suctioning, and smoke evacuation, can make the surgical procedures easier.
- 17 September 2011
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 19 (4) , 426-430
Single‐incision multiport laparoendoscopic surgery using a newly developed short‐type flexible endoscope: a combined procedure of flexible endoscopic and laparoscopic surgery
Background and objective: We hypothesized that using a flexible endoscope as a working scope in laparoscopic surgery through a single incision might provide many benefits. To this end, a short‐type flexible endoscope with a working length of 600 mm was newly developed. In this animal experimental study, we aimed to evaluate the technical feasibility of our new approach, single‐incision multiport laparoendoscopic (SIMPLE) cholecystectomy, using this endoscope.Methods: Eight pigs were subjected to SIMPLE cholecystectomy using the short‐type flexible endoscope. The endoscope was inserted through a 12‐mm trocar in an SILS™ Port followed by the insertion of two additional 5‐mm trocars in the SILS™ Port. Encirculation and ligation of the pedicle of the cystic artery and duct were carried out using laparoscopic instruments through the 5‐mm trocars, while the dissection of the gallbladder from the intrahepatic fossa was predominantly performed using a cutting device through the endoscope.Results: A complete gallbladder excision, with complete encirculation and ligation of the pedicle, was completed in all cases. The mean operating time was 58 min (range 34—78 min). The endoscope provided a good view of the operating field, and it allowed some degree of freedom to the working laparoscopic instruments without compromising the field of view. Dissection of the gallbladder using the cutting device through the endoscope was much easier than that using the laparoscopic device, because the articulating instruments together with the endoscope enabled operation with triangulation. Furthermore, the water‐jet and suctioning functions and the self‐cleaning lens capability of the endoscope served the surgery well.Conclusions: SIMPLE cholecystectomy using the newly developed short‐type flexible endoscope is a technically feasible procedure. Using this flexible endoscope for various tasks, such as resection, suctioning, and smoke evacuation, can make the surgical procedures easier.