HAHiroyuki Arakawa

Hiroyuki Arakawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hiroyuki Arakawa has a total of 172 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Spatial sharing in survey meter training utilizing mixed and augmented reality

    by H. Arakawa, T. Fujibuchi, K. Kaneko, Y. Okada

    Recent developments in immersive tools for radiation-related training have been notable. However, these training programmes have primarily been developed from a first-person perspective, often limiting the sharing of the training experience. This study developed a tool that facilitates real-time spatial sharing of training using mixed reality (MR) and augmented reality (AR). Our MR system, which wirelessly connected HoloLens 2 with a survey meter mock-up, enabled the visualisation of radiation and simulated a detector's response. It also shared training information every second via a WebSocket server. Concurrently, the AR system allowed observers, equipped with an AR tablet, to view the MR operator's status in real time based on this shared data. Post-training, the shared data were saved as text, enabling reflective learning through visualisation. We anticipate that this tool would significantly enhance the efficiency of survey meter training without radiation exposure.

  • Development of an AR application for radiation protection optimisation education of medical staff in x-ray fluoroscopy

    by T. Fujibuchi, H. Arakawa, T. Yoshinaga

    Medical staff handling radiological equipment may be exposed to occupational radiation when assisting patients or performing fluoroscopy-guided procedures in radiological examinations. In this study, we developed a radiation protection education application using augmented reality (AR) to display the scattered radiation volume data during supine x-ray examinations, including x-ray fluoroscopy. This application allows real-time estimation of the scattered radiation distribution in the room and the radiation exposure of medical staff. The ratio of calculated values to measured values for scattered radiation distribution fell within the range of 0.8 to 1.2 at 18 evaluation points. The scattered radiation distribution was displayed using AR on an iPhone or iPad. Additionally, the application provided real-time displays of the doses to the eyes, neck, chest, abdomen, and fingers of recognised medical staff through body tracking. This application is easy to use regardless of location and serves as an effective tool for radiation protection education for medical staff.

  • Decomposition of abrupt transport phenomena in Kelvin–Helmholtz turbulence by using multi-field singular value decomposition

    by T Kodahara, M Sasaki, Y Kawachi, T Kobayashi, Y Kosuga, H Arakawa, T Yamada

    A method of decomposition of abrupt transport phenomena in magnetized plasmas is demonstrated by using a data-driven science method. The set of turbulence data is produced for the Kelvin–Helmholtz turbulence in a cylindrical plasma by using a numerical nonlinear simulation, which is based on an extended Hasegawa–Wakatani model. The obtained turbulence state is accompanied by limit-cycle-like dynamics, and the abrupt particle transport phenomena is observed. We apply a singular value decomposition to the turbulence data with a clustering method, and the turbulence state is decomposed into background, zonal flows, and coherent and incoherent modes. The contribution of these decomposed modes to the particle transport is evaluated for all the combinations of the modes. It is found that the abrupt transport is mainly driven by the incoherent mode, and that it determines the spatio-temporal scale of the abrupt transport for the presented case.


  • Open Access

    Development of a Real-Time Radiation Exposure Estimation Method Using a Depth Camera for Radiation Protection Education

    by Toshioh Fujibuchi, Hiroyuki Arakawa, Choirul Anam

    X-ray fluoroscopy causes relatively high radiation exposure to physicians, radiation professionals, and patients. Understanding the behavior of scattered radiation is crucial for reducing occupational exposure. We developed a system for estimating radiation exposure during fluoroscopy by monitoring the position of the physician using a depth camera for radiation protection education. The dose distribution of scattered radiation in an X-ray room was simulated using Monte Carlo code. The data were displayed using augmented reality markers, and the dose at each joint point location was estimated using body tracking. Additional functions were created, such as displaying arbitrary two-dimensional cross-sections. The system performance ranged from 9.0 to 11.0 FPS with or without motion and a protective apron. The estimated doses were 0.93 to 1.21 times the measured doses for all joint points, except for the chest and pelvis. The estimated doses for the chest and pelvis were lower than the measured dose, with the minimum values being 0.72 and 0.60 times lower for the chest and pelvis, respectively. The system provides valuable insight into the estimation of radiation dose at joint points based on the physician’s position and movements, the physician’s optimal fluoroscopy location, and warning of dangerous exposure doses.


  • Open Access

    Evaluation of radiation protection effectivity in a cardiac angiography room using visualized scattered radiation distribution

    by Toshioh Fujibuchi, Misaki Nakashima, Hiroyuki Arakawa, Hitoshi Miyazaki, Choirul Anam

    In this study, we devised a radiation protection tool specifically designed for healthcare professionals and students engaged in cardiac catheterization to easily monitor and evaluate scattered radiation distribution across diverse C-arm angles and arbitrary physician associated staff positions—scrub nurse and technologist positions. In this study, scattered radiation distributions in an angiography room were calculated using the Monte Carlo simulation of particle and heavy ion transport code system (PHITS) code. Four visualizations were performed under different C-arm angles with and without radiation protection: (1) a dose profile, (2) a 2D cross-section, (3) a 3D scattered radiation distribution, and (4) a 4D scattered radiation distribution. The simulation results detailing the scattered radiation distribution in PHITS were exported in Visualization Toolkit format and visualized through the open-source visualization application ParaView for analysis. Visualization of the scattered dose showed that dose distribution depends on the C-arm angle and the x-ray machine output parameters (kV, mAs s−1, beam filtration) which depend upon beam angulation to the patient body. When irradiating in the posterior–anterior direction, the protective curtain decreased the dose by 62% at a point 80 cm from the floor, where the physician’s gonads are positioned. Placing the protection board close to the x-ray tube reduced the dose by 24% at a location 160 cm from the floor, where the lens of the eye is situated. Notably, positioning the protection board adjacent to the physician resulted in a 95.4% reduction in incident air kerma. These visualization displays can be combined to understand the spread and direction of the scattered radiation distribution and to determine where and how to operate and place radiation protection devices, accounting for the different beam angulations encountered in interventional cases. This study showed that scatter visualization could be a radiation protection teaching aid for students and medical staff in angiography rooms.


  • Open Access

    The Usefulness of a Virtual Environment-Based Patient Setup Training System for Radiation Therapy

    by Toshioh Fujibuchi, Kosuke Kaneko, Hiroyuki Arakawa, Yoshihiro Okada

    In radiation therapy, patient setup is important for improving treatment accuracy. The six-axis couch semi-automatically adjusts the patient’s position; however, adjusting the patient to twist is difficult. In this study, we developed and evaluated a virtual reality setup training tool for medical students to understand and improve their patient setup skills for radiation therapy. First, we set up a simulated patient in a virtual space to reproduce the radiation treatment room. A gyro sensor was attached to the patient phantom in real space, and the twist of the phantom was linked to the patient in the virtual space. Training was conducted for 24 students, and their operation records were analyzed and evaluated. The training’s efficacy was also evaluated through questionnaires provided at the end of the training. The total time required for patient setup tests before and after training decreased significantly from 331.9 s to 146.2 s. As a result of the questionnaire regarding the usability of training to the trainee, most were highly evaluated. We found that training significantly improved students’ understanding of the patient setup. With the proposed system, trainees can experience a simulated setup that can aid in deepening their understanding of radiation therapy treatments.


  • Open Access

    Radiation-training system with a custom survey-meter mock-up in a browser-based mixed reality environment

    by Hiroyuki Arakawa, Toshioh Fujibuchi, Kosuke Kaneko, Yoshihiro Okada, Toshiko Tomisawa


  • Open Access

    Investigation of patient release examination training in nuclear medicine using mixed reality

    by Hiroyuki Arakawa, Toshioh Fujibuchi, Yoshihiro Okada, Kosuke Kaneko, Toshiko Tomisawa

    In nuclear medicine, assessing residual radioactivity before patient release is essential. It is typically assessed by radiation detection with a survey meter. This protocol inadvertently exposes to radiation and requires proficiency in the use of the survey meter. This study developed a mixed reality system designed to provide exposure-free training during patient release examination. This system involves a virtual radiation source with visualized radiation emission on the corresponding part of the human mannequin. The time response characteristics of the survey meter to changes with the time constant in addition to the source distance were simulated in realtime.

  • A novel approach to predict acute radiation dermatitis in patients with head and neck cancer using a model based on Bayesian probability

    by Keisuke Hamada, Toshioh Fujibuchi, Hiroyuki Arakawa, Yuichi Yokoyama, Naoki Yoshida, Hiroki Ohura, Naonobu Kunitake, Muneyuki Masuda, Takeo Honda, Satoru Tokuda, et al.